SS-GACST-R32 www.goodmanmfg.com 11/24
Contents
Nomenclature ......................................... 2
Product Specicaons ............................3
Dimensions .............................................4
Airow Data ............................................5
Heat Kit Data ............................................ 5
Wiring Diagram .......................................6
Accessories .............................................7
* Complete warranty details available from your local dealer/contractor or at www.daikincomfort.com. To receive the
10-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online registraon
and some of the addional requirements are not required in Florida, California, or Québec. The duraon of warranty
coverage in Texas and Florida diers in some cases. Other limitaons and exclusions apply; refer to complete warranty
details for a full list of limitaons and exclusions.
ACST Series
Ceiling-Mount Air Handlers
1½ to 2½ Tons
■ Product Features
• All-Aluminum tube/aluminum n coil
• Direct-drive, resilient-mount, mul-speed motor
• Sequence-controlled and rust-resistant
nickel chromium heang elements
of 5, 6, 8 and 10 kW
• High-eciency evaporator coil
• Quiet operaon
• ACST Models: Equipped with a factory
installed and fully adjustable TXV for
improved performance
• Factory installed casing along with
mounng brackets for all tonnages
• Congurable front and boom return
for all tonnages
• Factory installed R-32 sensor designed
for the lifespan of the coil
• AHRI Cered; ETL Listed
• Primary/secondary drain connecon
in a high-temperature plasc drain pan
• Suitable for free-return installaon
(non-ducted return air)
• Galvanized-steel construcon
• Factory-installed pull-type disconnect
• Easy service access
• Opmized for the use with R-32 refrigerant
• Cabinet air leakage less than 2% at 1 inch H
2
O when
tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 1 inch H
2
O when
tested in accordance with ASHRAE standard 193

2 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 3
Nomenclature
A C S T 18 M U 1 3 0 5 A A
* *
1 2 3 4 5,6 7 8 9 10 11,12 13 14
Minor Revision
Brand
A
G - Goodman® Brand Air
Handler
A - Corporate Air Handler
Major Revision
A
Application
C - Ceiling Mounted
Electric Heat KW
M - Multi-Positional
W - Wall Mounted
F - Fit Compatible Multi-Position
Refrigerant
Motor
3 - R32
S - MS-ECM
V - VS-ECM Communicating
Electrical
Expansion Device
1 208/230 V, 1 Phase, 60 Hz
E - Electronic Expansion Valve
F - Flowrator
T - Thermal Expansion Valve
Cabinet
Nominal Capacity
N - Uncased
12 - 1.0 Ton 36 - 3.0 Tons
P - Painted
18 - 1.5 Tons 42 - 3.5 Tons U - Unpainted
24 - 2.0 Tons 48 - 4.0 Tons
30 - 2.5 Tons 60 - 5.0 Tons
Cabinet Width
AC* Series AM* Series AW* Series
M - 48.2” B - 17.5" S - 20.2”
L - 54.2” C -21.0" L - 36.05”
D - 24.5"

2 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 3
Product Specifications
ACST18
MU1305AA
ACST18
MU1308AA
AST24
LU13 05AA
ACST24
LU1306AA
ACST24
LU1308AA
ACST24
LU1310AA
ACST30
LU1305AA
ACST30
LU1306AA
ACST30
LU1308AA
ACST30
LU1310AA
Nominal Ratings
Cooling (BTU/h)
18,000 18,000 24,000 24,000 24,000 24,000 30,000 30,000 30,000 30,000
Blower
Diameter
6.3 6.3 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7
Width
8.06 8.06 8.06 8.06 8.06 8.06 8.06 8.06 8.06 8.06
Coil Drain Connect FPT
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Blower Motor
FLA
2 2 2 2 2 2 2 2 2 2
HP
1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Refrigerant Line
Connection Size
Liquid
⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon
¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage
208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity @ 230V
28.5 44.2 28.5 33.8 44.2 54.6 28.5 33.8 44.2 54.6
Min Circuit Ampacity @ 208V
25.1 38.6 25.1 29.6 38.6 47.6 25.1 29.6 38.6 47.6
Max. Overcurrent Device @ 230V
30 45 30 35 45 60 30 35 45 60
Max. Overcurrent Device @ 208V
30 40 30 30 40 50 30 30 40 50
Minimum Voltage VAC
197 197 197 197 197 197 197 197 197 197
Maximum Voltage VAC
253 253 253 253 253 253 253 253 253 253
Electric Heat
kW @ 230 Volts
5.0 8.0 5.0 6.0 8.0 10.0 5.0 6.0 8.0 10.0
BTU/h @ 230 Volts
15600.0 25000.0 15600.0 18800.0 25000.0 31300.0 15600.0 18800.0 25000.0 31300.0
Ship Weight (lbs)
85 85 97 97 97 97 97 97 97 97
Notes
• When the room thermostat calls for second stage heat, the rst stage (heat pump) operaon must be locked out. When matching the “AC” unit with a heat pump, order “HEAT
PUMP SHUT OFF KIT HPSK-01.”

4 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 5
Dimensions
ACST18 ACST24 ACST30
A 48
1
⁄
5
54
1
⁄
5
54
1
⁄
5
B 45
7
⁄
16
51
7
⁄
16
51
7
⁄
16
C 36
1
⁄
5
42
1
⁄
5
42
1
⁄
5
D 6½ 6½ 6½

4 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 5
Airflow Data
Model
Motor
Speed
Airflow rate delivered against External Static Pressure, (CFM)
0.1” 0.2” 0.3” 0.4” 0.5”
ACST18MU13**AA
T1 631 583 538 506 452
T2 631 583 538 506 452
T3 694 645 601 557 516
T4 831 776 729 685 605
T5 831 776 729 685 605
ACST24LU13**AA
ACST30LU13**AA
T1 829 766 721 674 631
T2 829 766 721 674 631
T3 869 820 773 728 686
T4 934 883 840 793 743
T5 934 883 840 793 743
Note: Airow data indicated is at 230 V with no lter in place.
Heating Capacity/kW Correction Factor
Supply Voltage 240 230 220 210 208
Correction Factor 1.00 0.92 0.84 0.77 0.75
(Mulply the 240V heang capacity with correcon factors)

6 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 7
Wiring Diagram — ACST18/ 24/ 30
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
GND
BK BLACK
BL BLUE
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
WIRE CODE
HIGH VOLTAGE
LOW VOLTAGE
EARTH GROUND
FIELD WIRING
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL LOW VOLTAGE
CHASSIS GROUND
FACTORY WIRING
1
2
3
4
5
EM
PLF1
0140A01601-A
POWER AND CONTROLS WIRING DIAGRAM
AIR HANDLER
HTR 1
TL1
OR
C
GR
PU
BL
WH
BK
BKRD
RD
RD
PK
PU
L1
L2
DISC
FIELD CONNECTIONS
USE N.E.C CLASS 2 WIRE
UNUSED WIRES MUST HAVE THEIR ENDS TAPED OR
CAPPED
MOTOR CONNECTIONS
ONLY ONE WILL BE CONNECTED
COMPONENT LEGEND
C CONTACTOR
DISC DISCONNECT SWITCH
EM EVAPORATOR MOTOR
F FUSE
GND GROUND
HTR HEATER ELEMENT
PLF FEMALE PLUG
PLM MALE PLUG
RDS
REFRIGERANT
DETECTION SYSTEM
TL THERMAL LIMIT
TR TRANSFORMER
RD
BK
RD
1
2
3
4
WH
READ THE INSTRUCTIONS
BL
WH PKBLRD
BK RD
BL
CB
TR
COM
RD
GR
BL BK
RD
L1 T1
C
L2 T2
BK
HTR 2*
TL2
RD
RD
BK
RD
RD RD
F4
F
4
F
YL
YL
RDS
PLM
RDS
EEV_IN
EEV_OUT
CTM_OUT
R_OUT
C
C
R
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
NOT USED
1
C
5V 2
PORT
R32
SENSOR
TABLE-1
III
III
CLASS III CONSTRUCTION
REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE
OF INSULATION AS ORIGINAL (AT LEAST 105° C).
USE COPPER CONDUCTORS ONLY.
USE N.E.C. CLASS 2 WIRE FOR ALL LOW VOLTAGE
FIELD CONNECTIONS.
CONFIRM SPEED TAP SELECTED IS APPROPRIATE
FOR APPLICATION. IF SPEED
TAPS NEEDS TO BE
CHANGED, CONNECT APPROPRIATE WIRE FROM
MOTOR TO "Y" FROM THERMOSTAT/CONDENSER
(SEE TABLE-1).
ASTERISK (*) INDICATES THAT HEATING ELEMENT,
THERMAL LIMIT, RELAY AND INTERCONNECTING
WIRES AND JUMPERS OF HEAT #2 ARE DELETED WITH
SINGLE ELEMENT UNITS.
NOTES
1
2
3
4
208V-230V / 1PH / 60Hz
5
BTUh
18000
PINK
WIRE
24000
PINK
30000
YELLOW
ACST18
ACST24
ACST30
MODEL
GR
TR PRIMARY (HIGH VOLTAGE)
CONNECTIONS: RED WIRE CONNECTED
TO 240V TAP AT THE FACTORY AND
BLACK WIRE TO COM TERMINAL.
FOR 208V SUPPLY POWER, MOVE RED
WIRE FROM 240V TAP TO 208V TAP.
LOW VOLTAGE TRANSFORMER RATED
24VAC OUTPUT 40VA @ 1.667 AMP.
C
L
G
N
C
L
G
N
BL
BK
GR/YL
RD
III
EM
PLM2
EM
PLF2
EM
PLM1
1
2
3
4
5
EM
~
M
1
BL
BL
5

6 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com 7
Accessories
Model Description
HPSK-01 Heat Pump Shut-o Relay Kit
Louvered Ceiling Access Panels
CAP-2/ 2L ACST18
CAP-3/ 3L ACST24/30

8 www.goodmanmfg.com SS-GACST-R32
SS-GACST-R32 www.goodmanmfg.com PB
Our connuing commitment to quality products may mean a change in specicaons without noce.
©2024 • Houston, Texas • Printed in the USA
Notes