Victory SV400J Modern Cylinder Round Island Range Hood

Product's Documents

Below are documents related to this product, you can read online or download:
SV400J photo

Installation Manual

This is the main product document for model SV400J. Additionally, the document applies to other Victory models: SV400J

The file format is pdf, 22 pages, you can download this manual here .

background
www.victoryrangehoods.com
Ceiling-Mount Range Hood
(ducted or ductless)
NOTICE: For residential use only.
Installer: Leave this guide with the homeowner.
Homeowner: Keep this guide for future reference.
Model Name:
SV400J
Rev.20221103b
INSTALLATION GUIDE
AND USERS MANUAL
background
VICTORY range hoods
| 400J
2
VICTORY range hoods
400J |
3
TABLE OF CONTENTS
Important Safety Notice............................................................................ 3
Electrical Requirements............................................................................ 5
Venting Requirements............................................................................... 6
Calculating Vent System Length.............................................................. 7
Specications............................................................................................ 7
Parts Supplied............................................................................................ 8
Dimensions................................................................................................. 10
Preparation................................................................................................. 11
Rough-In..................................................................................................... 12
Installation.................................................................................................. 14
Venting Methods........................................................................................ 16
Recirculation Option................................................................................. 17
Troubleshooting......................................................................................... 18
Required Tools........................................................................................... 8
Range Hood Operations............................................................................ 17
Maintenance............................................................................................... 19
Warranty...................................................................................................... 20
Disclaimer................................................................................................... 21
Contact Us................................................................................................. 21
Do’s and Don’ts for Duct Venting............................................................. 16
background
• The installation in this manual is intended for qualied installers, service technicians or
persons with similar qualied background. Installation and electrical wiring must be done by
qualied professionals and in accordance with all applicable codes and standards, including
re-rated construction.
• DO NOT attempt to install this appliance yourself. Injury could result from installing the unit
due to lack of appropriate electrical and technical background.
• Range hood may have very sharp edges; please wear protective gloves if it is necessary to
remove any parts for installing, cleaning or servicing.
• Activating any switch ON before completing installation may cause ignition or an explosion.
• Due to the size and weight of this range hood, two-person installation is recommended.
To reduce the risk of re, electric shock, or injury to persons:
• For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials
and vapors.
• The combustion air ow needed for safe operation of fuel-burning equipment may be a󰀨ected
by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire Protection Association (NFPA), and
the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
• Before servicing or cleaning unit, switch power OFF at service panel and lock service panel
to prevent power from being switched ON accidentally.
• Clean grease laden surfaces frequently. To reduce the risk of re and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust into spaces between walls, crawl
spaces, ceiling, attics and/or garages.
• Ducted fans MUST always be vented to the outdoors.
• Use only metal ductwork and this unit MUST be grounded.
• Su󰀩cient air is needed for proper combustion and exhausting of gases through the duct to
prevent back drafting.
• When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other
hidden utilities.
• All electrical wiring must be properly installed, insulated and grounded.
• Old duct work should be cleaned or replaced if necessary to avoid the possibility of a grease
re.
• Check all joints on duct work to insure proper connection and all joints should be properly
taped.
• Use this unit only in the manner intended by the manufacturer. If you have questions, contact
the vendor.
To reduce the risk of a stove top grease re:
• Keep all fans, spacers, lters, grease tunnels, oil containers and grease-laden surfaces
clean. Grease should not be allowed to accumulate on fan, ba󰀪e, spaces, lter, grease
tunnel and oil container.
• Always turn range hood ON when cooking at high heat or when cooking foods that produce
ames.
• Use high settings on cooking range only when necessary.
• Never leave surface units unattended at high settings. Boil overs cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or medium settings.
VICTORY range hoods
| 400J
2
VICTORY range hoods
400J |
3
IMPORTANT SAFETY NOTICE
Read all instructions before installing and operating this appliance
background
• Clean ventilating fan frequently.
• Always use appropriate cookware and utensils size.
• Always use cookware appropriate for the size of the surface element.
To reduce the risk of injury to persons in the event of a stove top grease re:
• Smother ames with a close-tting lid, cookie sheet, or metal tray, then turn OFF the burner.
Be careful to PREVENT BURNS. Never pick up a pan that has ames—you may be burned.
Keep ammable and/or combustible material away from ames. If the ames DO NOT go out
immediately, EVACUATE and CALL the FIRE DEPARTMENT or dial your local emergency
service immediately.
• DO NOT use WATER, including wet dishcloths or towels — it will result in a violent steam
explosion
• Use an extinguisher ONLY if:
• You know you have a Class A, B, C extinguisher, and you already know how to operate it.
• The re is small and contained in the area where it has started.
• The re department is on the way.
• You can ght the re while having access to a safe exit.
To reduce the risk of injury to persons in the event of a gas leaks:
• Extinguish any open ame.
• DO NOT turn on the range hood fan or any type of ventilator.
• DO NOT turn on the lights or any type of appliance.
• Open all doors and windows to disperse the gas. If you still smell gas, call the gas company
and re department or dial your local emergency service immediately.
Your safety and the safety of others is very important. We have provided many important
safety messages in this manual and on your appliance. Always read and obey all safety
messages. All safety messages will tell you what the potential hazard is, tell you how to
reduce the chance of injury, and tell you what can happen if the instructions are not followed.
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you
and others. All safety messages will follow the safety alert symbol and the word “WARNING”.
The manufacturer and/or distributor/reseller declines all responsibility in the event of failure
to observe the instructions given here for installation, maintenance and suitable use of the
product.
The manufacturer and/or distributor/reseller further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
The manufacturer and/or distributor/reseller will not be held responsible for any damages to
personal property or real estate or any bodily injuries whether caused directly or indirectly by
the range hood.
VICTORY range hoods
| 400J
4
VICTORY range hoods
400J |
5
IMPORTANT SAFETY NOTICE
Read all instructions before installing and operating this appliance
background
IMPORTANT: Observe all governing codes and ordinances.
It is the customer’s responsibility:
• To contact a qualied electrician
• To assure that the electrical installation is adequate and in conformance with National
Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22. 1-94, Canadian
Electrical Code, Part 1 and C22. 2 No. 0-M91 - latest edition** and all local codes and
ordinances.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrician
determine that the ground path is adequate.
A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit.
DO NOT ground to a gas pipe.
Check with a qualied electrician if you are not sure that the range hood is properly grounded.
DO NOT have a fuse in the neutral or ground circuit.
IMPORTANT: Save this Installation Guide for electrical inspector’s use.
The range hood must be connected with copper wire/plug only.
The range hood should be connected directly to the fused disconnect (or circuit breaker) box
through exible armored or non-metallic sheathed copper cable. A U.L. - or C.S.A. - listed strain
relief must be provided at each end of the power supply cable.
Wire sizes (copper wire only) and connections must conform with the rating of the appliance
as specied on the model/serial rating label. Wire sizes must conform to the requirements
of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.
1-94, Canadian Electrical Code Part 1 and C22. 2 No. 0-M91 - latest edition** and all
local codes and ordinances. A U.L. - or C.S.A. - listed conduit connector must be provided
at each end of the power supply cable (at the range hood and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
VICTORY range hoods
| 400J
4
VICTORY range hoods
400J |
5
ELECTRICAL REQUIREMENTS
background
• Vent system must terminate to the outside (roof or side wall).
• DO NOT terminate the vent system in an attic or other enclosed area.
• DO NOT use 4” or 5” laundry-type wall caps. Use a 6” or larger Wall/Roof Cap.
• Use metal/aluminum vent only. We recommend using Rigid instead of Flex duct.
• Always keep the duct clean to ensure proper airow.
For the most e󰀩cient & quiet operation:
• It is recommended that the range hood be vented with a 6” or bigger round metal/aluminum
vent work.
• The size of the vent should be uniform.
• Use no more than two 90° elbows.
• Make sure there is a minimum of 24” (61 cm) of straight vent between the elbows if more
than one elbow is used.
• DO NOT install two elbows together.
• The length of vent system and number of elbows should be kept to a minimum to provide
e󰀩cient performance.
• Use aluminum foil tape to seal all joints in the vent system.
• Use caulking to seal exterior wall or roof opening around the cap.
• Use 45 degree elbows instead of 90 degree elbows when possible.
IMPORTANT:
• A minimum of a 6” round duct (standard for this range hood) must be used to maintain
maximum airow e󰀩ciency.
• Always use rigid type metal/aluminum ducts if available to maximize airow when
connecting to provided duct.
• Please use Duct Run Calculation below to compute total available duct run when using
elbows, transitions and caps.
• ALWAYS, when possible, reduce the number or transitions and turns in the duct run. If a
long duct run is required, increase the duct size from 6” to 8”. If a reducer is used, install a
long reducer instead of a pancake reducer. Reducing the duct size will restrict airow and
decrease e󰀩ciency.
• If turns or transitions are required: Install as far away from opening and as far apart,
between 2, as possible.
Minimum Duct Size:
• Round - 6” minimum
VICTORY range hoods
| 400J
6
VICTORY range hoods
400J |
7
VENTING REQUIREMENTS
background
To calculate the length of the duct system you require, subtract the equivalent feet for each
“Vent piece” (Table Below) used in the system from the “Recommended maximum run” (Table
Below). The longest duct run that is acceptable (if completely straight) is 50 feet. The number
of vent pieces (elbow, transition, etc.) installed in your duct run will determine the maximum
length the duct run can be. Please refer to the example below:
Body Design Seamless Stainless Steel, Brushed Finish
Power Rating 120V/60Hz (USA & Canada standard)
General Input Power 122 W (120W + 2 x 1W)
Motor Input Power 120 W
Ampere 4 A
Levels Of Speed Control 3 Levels
Airow
1
(Q/M/H) 200 CFM / 400 CFM / 600 CFM
Noise Level
2
(Q/M/H) 1.0 Sone / 3.5 Sone / 5.5 Sone
Number Of Motors Single Motor
Motor Type Single Chamber Ultra Quiet
Fan Type Centrifugal Squirrel Cage
Control Type Electronic Control Panel
Filtration Type 1 Aluminum Mesh Grease Filter and 2 Charcoal Filters
Illumination 2 x LED 1W 12v
Venting Type Top Vent 6” Round, or optional Recirculated
Duct Run Calculation:
Recommended maximum run
6” round duct 50 ft
Vent piece deduction
Each 90º elbow used 9 ft
Each 45º elbow used 5 ft
Each Round - Rectangle transition used 7 ft
Side wall cap with damper 7 ft
Roof cap 7 ft
Duct Run Calcuation example:
One roof cap, two 90º elbows, and
one 45º elbow used:
7ft + 9ft + 9ft + 5ft = 30ft used.
The above vent pieces used are
equivalent to 30ft of a straight
duct run. Subtract 30ft from the
allowable 50ft. The remaining
distance of 20ft is the longest that
the straight ducting (in addition to
the vent pieces) can be.
1. In House Test Static Pressure “0”.
2. One sone is roughly equivalent to the sound of a refrigerator (1kHz) at 40 decibels.
3. Subject to change without notice, please contact your local reseller for details.
VICTORY range hoods
| 400J
6
VICTORY range hoods
400J |
7
CALCULATING VENT SYSTEM LENGTH
SPECIFICATIONS
background
Putty
Knife
Pencil
Tape
Measure
Level
Phillips
Screwdriver
Aluminum Tape
Power
Drill
Utility
Knife
Drywall
Knife
Conc
rete
Anchor
(x6)
Woodsc
rew
s
w
ith conc
rete
anchors
(x9)
M
4 - 4m
m
Flange H
ead
(x44)
Washer
M
4 - 4m
m
N
ut
(x38)
M
4 - 4m
m
Button H
ead
(x3)
NOTE:
Where necessary, additional screws will be needed for installation and added
support, but is not included. Please review contents before installation.
VICTORY range hoods
| 400J
8
VICTORY range hoods
400J |
9
REQUIRED TOOLS
PARTS SUPPLIED
background
400J Unit (and chimney)
Mounting Bracket
(x1)
Frame Posts
(x6)
Frame Anchors
(x3)
VICTORY range hoods
| 400J
8
VICTORY range hoods
400J |
9
PARTS SUPPLIED (Continued)
background
BOTTOM VIEW
FRONT VIEW SIDE VIEW
TOP VIEW
6”- Ø
Transition
13 ¾”- Ø
11”
Adjustable
height from
30
½” to 40”
VICTORY range hoods
| 400J
10
VICTORY range hoods
400J |
11
DIMENSIONS
background
Advanced Preparations:
• Be familiar with the controls of the range hood by reading through Range Hood Operations.
• Place the range hood on a at, stable surface. Connect the range hood to a designated
standard outlet (please refer the product label for the suitable voltage of this unit) and turn
on the range hood. Verify all operations of the range hood by referring to Range Hood
Operations. Place all supplied parts and required hardware on a at, stable surface and
verify the existence of all supplied parts.
• Carefully remove the white or blue plastic protective coat from the range hood.
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.
• Decide the location of the venting pipe from the hood to the outside. Refer to Venting Methods.
• A straight, short vent run will allow the hood to perform more e󰀩ciently.
• Try to avoid as many transitions, elbows, and long run as possible. This may reduce the
performance of the hood.
• Using 45 degee elbows is better than using 90 degree elbows.
• IMPORTANT: Peel white plastic protective coat o󰀨 the hood, if any.
• Use aluminum tape to seal joints between pipe sections.
THE HOOD MUST BE TESTED BEFORE INSTALLATION.
PLEASE TEST THE RANGE HOOD FOR PROPER OPERATION BEFORE
BOXING IT, OR RECESSING IT INTO THE CEILING.
DO NOT CLOSE THE BOX AROUND THE HOOD UNTIL THE TEST HAS
BEEN PERFORMED.
Victory Range Hoods Inc. will not be responsible for additional labour costs related to
reinstallation of the hood due to transportation internal damage or wiring issues.
VICTORY range hoods
| 400J
10
VICTORY range hoods
400J |
11
PREPARATION
background
JoistJoistJoist
Ceiling
Will fit 8ft ceiling.
(Fit 10ft ceiling, contact Victory for
frame post and chimney extensions)
36”
(Typical)
24” minumum
30” maximum
400J Unit
centered
above stove
Combined length of
chimney and unit
can reach up to 40”
VICTORY range hoods
| 400J
12
VICTORY range hoods
400J |
13
ROUGH
-
IN
background
Woodscrews (x8)
JOIST
Additional
Support
Duct Venting
VICTORY range hoods
| 400J
12
VICTORY range hoods
400J |
13
ROUGH
-
IN (Continued)
background
Flex duct not included.
VICTORY range hoods
| 400J
14
VICTORY range hoods
400J |
15
INSTALLATION
background
Ensure a certied electrician
installs the wiring.
Check the fan motor and lights
are functioning prior to raising
and fastening the chimney.
Flex duct not included.
NOTE: Use a stable platform
to rest the range hood and/or
receive assistance to hold on
range hood.
CAUTION: Make certain the
range hood is secure before
releasing!
VICTORY range hoods
| 400J
14
VICTORY range hoods
400J |
15
INSTALLATION (Continued)
background
Motor
Backdraft
Damper
Backdraft Damper
Wrap insulation
required for
cold climates
6” Ø Duct
Wall Vent Cap
Roof Vent
(a)
(b)
(c)
• This range hood is factory set for venting through
the roof or wall.
• Duct work can terminate either through the
roof or wall. To vent through a wall, a 90°
elbow is needed.
IMPORTANT:
• NEVER exhaust air or terminate duct work into
spaces between walls, crawl spaces, ceiling,
attics or garages. All exhaust must be vented to
the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws
and tape all joints with certied Aluminum Tape.
• Use caulking to seal exterior wall or roof opening
around the cap.
• Colder climates require wrapping insulation
around the ducts and optional blowers.
• The system must have a Backdraft Damper.
* Due to di󰀨erent ceiling height congurations, recommended height may not be applicable.
a. Avoid the use of sharp elbows. Use 45 degrees instead, if possible.
b. DO NOT use REDUCERS. Keep the size of the duct the same, as per the manual. A reducer
will reduce the CFM of the hood and increase the noise.
c. DO NOT use plenum boxes. Boxes create turbulence and make the hood ine󰀩cient. Use a
smooth elbow to guide the air outdoors.
VICTORY range hoods
| 400J
16
VICTORY range hoods
400J |
17
VENTING METHODS
DO’S AND DON’TS FOR DUCT VENTING
background
MOTOR
Unlock
Lock
Optional Charcoal Filters
For ductless operation and to
recirculate the air and filtered
through replaceable charcoal
filters. These filters will need
to be ordered separately.
Standard
Filter
Low
Mid
High
Lights
Power
On / Off
Fan Blower
Speed
CONTROL PANEL
1. After connecting to power, indicator lights on each button will
illuminate, and ready for standby. The lights will turn o󰀨 when
there is no activity
1. Press the “Power” button to turn ON and OFF the range hood
unit.
2. Press any of the Fan Blower speeds to select which desired
speed: Low/Mid/High
3. Press “Light” button to turn ON and OFF the lights. The Light
button works independently from the “Power” button.
VICTORY range hoods
| 400J
16
VICTORY range hoods
400J |
17
RECIRCULATION (Ductless Operation)
RANGE HOOD OPERATIONS
background
1. If the range hood or lights do not operate
after installation:
• Check if the range hood has been plugged
in, make sure that all power has been
turned back ON, fused not blown and all
electrical wiring are properly connected.
• Swap out light assembly to working ones to
determine whether it is caused by defective
bulbs. Contact Victory Range Hoods for
assistance to replace bulb.
2. The range hood vibrates when the blower
is on:
• The range hood might not have been
secured properly on to the ceiling or wall.
• The impeller may be out of balance.
3. The blower or fan seems weak: • Duct is too small. Range hood WILL NOT
function e󰀩ciently with insu󰀩cient duct size.
For example: Connecting this hood to 4” or
5” duct will reduce the suction and create
extra noise and vibrations. Check if duct
is clogged or if damper unit is not installed
correctly or opening properly. A tight mesh
on a side wall cap unit might also cause
restriction to the air ow.
4. The lights work but the blower is not
spinning at all, is stuck or is rattling.
• The blower might be jammed or scraping
the bottom due to shipping damage. Please
contact us immediately.
5. The hood is not venting out properly: • Make sure the distance between the stove
top and the bottom of the hood is within*
24” and 30” in distance. *Due to dierent
ceiling height congurations, recommended
height may not be applicable.
• Reduce the number of elbows and length
of duct work. Check if all joints are properly
connected, sealed, and taped.
• Make sure the power is on high speed for
heavy cooking.
• The duct size must be 6”, or larger. Please
make sure there are NO reducers or
plenums in the duct work.
• Refer to DO’S and DON’TS for DUCT
VENTING page for illustrative examples.
NOTE: For all other inquiries, please contact Victory Range Hoods.
VICTORY range hoods
| 400J
18
VICTORY range hoods
400J |
19
TROUBLESHOOTING
background
NOTE: For all other inquiries, please contact Victory Range Hoods.
SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!
For optimal operation, clean range hood and any lter/grease tunnel/oil container regularly.
Regular care will help preserve the appearance of the range hood.
Cleaning Exterior surfaces:
• Clean periodically with stainless steel cleaner and clean cotton cloth. Do not use corrosive or
abrasive detergent (e.g. Comet Power Scruv
®
, EZ-O󰀨
®
oven cleaner), or steel wool/scoring
pads, which will scratch and damage the stainless steel surface. For heavier oil use liquid
degrease such as “Forumla 409
®
” or “Fantastic
®
” brand cleaner.
• If the hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the
surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow
directions of the stainless steel cleaner. CAUTION: Do not leave on too long as this may
cause damage to the hood nish. Use a soft towel to wipe o󰀨 the cleaning solution, gently
rub o󰀨 any stubborn spots. Use a dry soft towel to dry the hood.
• After cleaning, you may use non abrasive stainless steel polish such as 3M
®
or ZEP
®
, to
polish and bu󰀨 out the stainless luster and grain. Always scrub lightly, a with clean cotton
cloth, and with the grain.
• DO NOT allow deposits to accumulate or remain on the hood.
• DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the
surface and cause rusting.
• DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain
in contact with stainless steel for extended periods. Many of these compounds contain
chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean
cloth.
Changing Charcoal Filters:
• Contact Victory Range Hoods to order new charcoal lters
• Filters should be changed every 3 to 6 months depending on frequency of use
• Make sure the range hood is unplugged or turn OFF breaker before removing lters
• After installing lters, turn ON breaker and range hood to test for operation.
Cleaning Aluminum Mesh Grease Filter:
• Filters should be cleaned after every 30 hours of use.
• Aluminum lters are NOT dishwasher safe. Spray “Formula 409
®
” or equivalent degreasing
detergent and leave to soak if very dirty. Dry the lters and re-install before using the hood.
Replacing Aluminum Mesh Grease Filters:
• Should lters wear out due to age and prolonged use, please contact Victory Range Hoods
to order replacement lters.
Replacing the light bulb:
• This range hood uses LED 1W 12v bulbs (please refer to the actual specication of the hood
purchased)
• Make sure the range hood is unplugged or turn OFF breaker.
• Contact Victory Range Hoods for assistance to replace bulb.
• Turn ON breaker and range hood to test for operation.
VICTORY range hoods
| 400J
18
VICTORY range hoods
400J |
19
MAINTENANCE
background
TO OBTAIN SERVICE UNDER WARRANTY:
You must present proof of original purchase date.
Please provide an original dated proof of purchase (sales receipt / invoice)
in order to obtain service under warranty.
The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details.
One Year Parts Warranty:
For one year from the date of original purchase, Victory Range Hoods will provide free of
charge, non-consumable replacement parts or components that failed due to manufacturing
defects. Subject to the conditions and limitations set forth below, Victory Range Hoods will
replace any part of its products that prove defective by reason of improper workmanship or
materials. Replacement parts or products will be provided by Victory Range Hoods on an
exchange basis, and will be either new or refurbished to be functionally equivalent to new.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary
home use.
This Warranty Will Be Voided When:
Product is damaged through negligence, improper installation, accident, abuse, misuse,
natural disaster, insu󰀩cient or excessive electrical supply, abnormal mechanical or
environmental conditions, or any unauthorized disassembly, repair, modication, or failure to
follow installation instructions. When product is used commercially or other than its intended
purpose. Damaged because of improper connection with equipment of other manufacturers.
Repaired or modied by anyone other than Victory Range Hoods. This limited warranty
also does not apply to any product on which the original identication information has been
altered, obliterated or removed, has not been handled or packaged correctly or has been
sold as second-hand.
What is Not Covered:
Consumable parts such as light bulbs, metal and charcoal lters. The natural wear of nish,
and wear due to improper maintenance, use of corrosive and abrasive cleaning products,
pads, and oven cleaner products. Chips, dents or cracks due to abuse, misuse, freight
damage, or improper installation. Damage of product caused by accident, re, oods or
acts of God. The manufacturer and/or distributor/reseller is not liable for, and does not cover
under warranty, any loss of properties or any costs associated with removing, servicing,
installing, or determining the source of problems with this product.
This warranty is valid in Canada and the United States of America. It is non-transferable and
applies only to the original purchaser and does not extend to subsequent owners of this product.
Any applicable implied warranties, including the warranty of merchantability, are limited in
duration to a period of express warranty as provided herein beginning with the date of original
purchase and, no warranties, whether expressed or implied, shall apply to this product thereafter.
To obtain warranty service, you may contact Victory Range Hoods. Please conrm the terms
of Victory Range Hood’s policies prior to contacting us. Typically, you must include product
identication information, such as the model number/name with a detailed description of the
problem you are experiencing. You must also include proof of the date of original purchase as
evidence that the product is within the applicable warranty period, and that it is a genuine range
hood from Victory Range Hoods.
VICTORY range hoods
| 400J
20
VICTORY range hoods
400J |
21
WARRANTY
background
Carefully inspect all items for damages before accepting delivery. note any damages on the
freight bill or express receipt. request name and signature of the carrier’s agent and keep a
copy to support your claim. Upon acceptance of items, owner assumes responsibility for its
safe arrival. Report damages to the carrier and le a claim immediately. Failure to do so may
result in the denial of your claim. The carrier will furnish you with necessary forms for ling a
claim.
Damages on any returns or exchanges caused during transit are not covered under our war-
ranty (the customer must insure the return with the shipping company). If your range hood is
damaged in transit, please contact us within 14 days of receiving your new order to report the
damages. Victory Range Hoods will, to the best of its ability, le a damage claim and investi-
gate the matter.
Please inspect contents of package(s) carefully upon receiving! We must be notied of any
damages and/or missing parts within fourteen (14) days upon your receipt of the package(s).
Claims will not be accepted after fourteen (14) days. NOTE: Items are thoroughly tested and
carefully packed in our facility before shipping.
Products must be returned in good working condition with ALL original parts and documenta-
tion packed in all original cartons, llers and shipping cartons. A restocking fee of 10% will be
charged for all approved return(s). Exchanges or returns will not be accepted if the unit has
been installed, and may be rejected if parts are missing.
Make sure to inspect the hood for damages and defects before installation. Appearance aws
of the hood found after installation and not a󰀨ecting hood performance are not covered under
our warranty for returns or exchanges. Service visits are not covered under warranty and will
carry a service charge.
If you require assistance, please contact Victory Range Hoods. Please have your order number
and model of the range hood ready. You must have this information in order to receive a response
to your request.
If you need replacement parts, we recommend using only genuine parts. Our accessories
and parts are engineered and designed specically for VICTORY range hoods. Each part is
rigorously tested assuring the utmost in durability and reliability, providing a factory match,
factory-installed appearance and functionality tailored to each individual range hood model.
583 Nicola Avenue, Port Coquitam, BC, Canada
Toll Free: 1-800-394-4020
The information in this document is subject to change without notice, please contact Victory Range Hoods for updated details.
VICTORY range hoods
| 400J
20
VICTORY range hoods
400J |
21
DISCLAIMER
CONTACT US
background
583 Nicola Avenue | Port Coquitlam | BC | Canada | V3B 0M3
www.victoryrangehoods.com

Specifications

Indexed Terms: Island Range Hood, Cylinder

Victory SV400J Questions and Answers

Questions and Answers

Related Products