Parrot Uncle F8009BK 72 Inch Aries Black Downrod Mount LED Windmill Ceiling Fan with Remote Control

Product's Documents

Below are documents related to this product, you can read online or download:
F8009BK photo

Installation Manual

This is the main product document for model F8009BK.

The file format is pdf, 16 pages, you can download this manual here .

background
F8009
www.parrotuncle.com
background
F8009
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Safety Information
1.To reduce the risk of an electrical blow, electricity on the
protective switch or the safety box went out before starting.
2.All wiring must correspond to the NASI/NFPA 70-1999
National Electric Code and local electrical regulations. The
electrical installation must be carried out by a qualified and
approved electrician.
3.The connection box and support construction must be
assembled safely and 35 pounds (15.9 kilos) must be able
to transport reliably. Use only output boxes listed with
labeling
"Accepted for fans with a weight of 35 lbs (15.9 kg) or less."
4.The fan must be installed with a minimum distance of 2.1 m
(7 feet) from the posterior edge of the wings to the floor.
5.Do not operate the reverse switch if the fan wings are
moving. You have to turn off the fan and stop the wings
before reverse the direction of the wing.
6.Do not place objects on the road to wings.
7.To avoid lesions or damage to the fan and other objects, be
careful if you work on the fan or clean it.
8.Electrical diagrams only serve as a reference. The lighting
rates that are not delivered with the fan must be listed and
marked with the valve model that will be installed for use.
The switches must be general use switches UL. Take into
account the instructions for the appropriate installation
included in the lighting rates and the switches.
9.After the electrical connections have been made, the size
staircase must be turned up and carefully push to the plug
box. The cables must be distributed in such a way that the
ground connected driver and the device head are next to
the socket.
All fixing screws must be verified before installation and, if
necessary, followed.
installation or after installation. Do not put any object on
the path of wings.
WARNING:Remove rubber motor attacks at the
bottom of the fan before mounting the wings or try
the engine.
WARNING:To avoid the risk of a fire or an electrical
blow, this fan should not be used with a semiconductor
speed controller.
WARNING:To avoid a possible electric shock, turn off
the current in the main security box before wiring. If
you feel that you do not have enough knowledge or
experience in electrical wiring, communicate with a
license electrician.
WARNING:Electrical diagrams only serve as a
reference. The optional use of a lighting rate must
be on the list and marked with this fan for use.
WARNING:To reduce the risk of fires, electrical
discharges, or injuries, assemble the device in a
socket that with the inscription is accepted for fans
with a weight of 35 lbs (15.9 kg) or less. It is marked
and use the screws supplied with the plug.
TECHNICAL INFORMATION
SKU
Nominal voltage
F8009
110V AC
35W
18W (included)
Nominal output (motor) Light
WARNING:To reduce the risk of injury, knife supports
(also known as flanges) cannot be folded during
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
.
1
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
1. To avoid possible eleciric shock, turn off the electicty at the main fuse box or circuit panel before you begin the fan instalalion or
before servicingthe fan or installing accessories.
2. Read all instructions and safety information carefully before installing your fan and save these instructions.
3. Make sure all electrical connections comply with local codes or ordinances and the National Electical Code. lf you are unfamilar with
electric wiring, please use a qualified and licensed electrician.
4. Make sure you have a location selected for your fan that alow clear space for the blades to rotate, and at least seven (7) feet of clearanced
between the floor and the fan blade tips, The fan should be mounted at least thirty (30) inches from walls or other upright structures.
5. WARNING: The oulet box and celing support joist used must be securely mounted, and capable of supporing at least 100 pounds, To
reduce the risk of fire, eleclric shock or personal injury, mount to the outlet box marked acceptable for fan supported and use mounting
screws provided with the outlet box. The box must be supported directly by the building structure.
6. WARNING: To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked "acceptable for fan support" and use mounting
screws provided with the outlet box most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan
support and may need to be replaced. Consult a qualified electrician if in doubt.
7. Electrical diagrams are for reference only, Light kits that are not packed with the fan must UL listed and marked suitable for use with the
model fan you are installing. Switches must be UL. general use switches, Refer to the instructions packaged with the light kits and
switches for proper assembly.
8. After installation is complete, check that all connections are absolutely secure
9. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires
should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
10. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device, or rheostat.
11. Do not separate the reverse switch until the fan has come to a complete stop.
12. Do not insert anything into the fan blades while they are rotating.
13. WARNING: To reduce the risk of personal injury, do not bend the blade brackets (also referred to as "flanges" )during assembly or after
installalion, Do not insert objects in the path of the blades.
14. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
15. Do not use water or detergent when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations
that may occur. it must be understood that common sense and caution are necessary factors in the installation and operation of this fan.
NOTE: This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities are
different or are impaired, or lack of experience or knowledge, unless such persons are supervised or trained to operate the aplance
by a person responsible for their safety.
NOTE: Children should be supervised to ensure that they do not use appliances as a toy.
SAFETY TIP
THANK YOU FOR YOUR PURCHASE
Thank you for purchasing this quality product, To ensure correct function and safety, please read and save all
instructions before using the product
2
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
Please check whether above accessories are completed or not? Yes, and install.
Wood screw (4PCS)
Spring sasher (4PCS)
Star washer(4PCS)
Plastic wire nut (8PCS)
Mounting screw (2PCS)
Balanced parts package(1PCS)
Washer (4PCS)
3
Fan blades X9
Mounting bracket
Canopy
Canopy cover
Coupling cover
5"ball/downrod assembly
10"downrod (Standby)
Hanging Pin
"R"Locking Pin
Fan-motor assembly
Blades Arm x9
Light plate
LED light kit
Glass lamp shade
Blades Arm screws x19
Blades Screw X 28
Paper Gasket X28
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
Mount the mounting bracket to the
outletbox using two self tapping screws,
two star washers and two washers.
Phillips
screwdriver
Phillips
screwdriver
1
2
3
4
Outlet box
Mounting Bracket
Washers
Self tapping screw
Star washers
Remove the hanging pin and "R" locking
pin from the downrod.
Loosen the two screws at the top of the
fan-motor assembly.
Mounting Bracket
Shoulder
screw
Phillips
screwdriver
Pass the downrod assembly through the
canopy, canopy cover, coupling cover.
Run the wires of the fan-motor assembly
through the downrod assembly.
Thread the hanging pin through the
fan-motor assembly and insert the
"R" locking pin. Lock the two screws.
Remove the shoulder screws from
the mounting bracket.
4
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
5
OK
NO
Install the fan-motor assembly into the
mountingbracket, taking care to install
it in place.
Phillips
screwdriver
Securely attach and tighten the canopy
cover over the shoulder screw heads in
the mounting bracket utilising the key
slot twistlock feature.
Use the shoulder screw to lock the canopy
to the mounting bracket.
6
5
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
2.Remove and save the two canopy screws in the round holes.
This will enable you to remover the mounting bracket.
1.Remove the mounting bracket from the canopy by
loosening the two canopy screws located in the L shaped slots.
Mounting bracket
Receiver
NOTE Wires omitted for clarity
:
7
R
2.Push the canopy ring to the bottom of the canopy,
slide the inner holes aligned to the two prominent screws
on the mounting bracket again, and turn the canopy ring
clockwise until tight.
1.Carefully push the canopy to the bottom of the mounting
bracket, make two sliding holes aligned to the two prominent
screws on the mounting bracket, and the turn clockwise until
tight.
6
Use wire connecting nuts supplied with the fan
FROM POWER SOURCE
AC 110- 120 VOLT 60Hz
3.5AMPS.
OUTPUT
RECEIVER
WIRE NUT
Use wire connecting nuts
supplied with the remote
controller.
RED
RED
GREY
GREY
YELLOW
YELLOW
INPUT
WHITE
WHITE
BLACK
BLACK
GREEN
GREEN
GREEN
GREEN
Monnting bracket
BLUE
BLUE
WHITE
WHITE
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
8
Phillips
screwdriver
9
7
Install the fan blades on the blades
arm with three blade screws and
three paper gasket.
Repeat the previous step 8 times.
Install the blade arm on the motor
assembly with two blades arm
screws.
Repeat the previous step 8 times.
Phillips
screwdriver
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
Phillips
screwdriver
11
12
8
Phillips
screwdriver
Phillips
screwdriver
Remove three screw from motor assembly
Install the light plate to the motor assembly
with three screw
Remover three screw from light plate.
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
Phillips
screwdriver
11
12
9
Connect the LED light assembly wiring
terminals and the corresponding motor
assembly wiring terminals.
Install the LED light assembly to the light
plate with three screws.
Rotate the glass lamp shade clockwise to
tighten it.
12
Phillips
screwdriver
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
10
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
Size of product
11
Ø5.9 In
2.2 In
10.9 In
13.4 In
Ø8.1 In
Ø8.1 In
Ø72 In
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
12
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
light
light light
light
13
F8009
background
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
AFTER INSTALLATION
WOBBLE
The fan blades have been adjusted in the factory to minimize any wobble.
NOTE: CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY ARE
MOUNTED ON A . IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING, IT MOUNTING BRACKET
WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMETERS
IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM.
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE
MOUNTING BRACKET AND DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
1.Check that all blade and blade arm screws are secure.
2.Most fan wobbling problems are caused when blade levels are unequal. Check this level by selecting a
point on the ceiling above the tip of one of the blades. Measure this distance.Rotate the fan until the next blade
is positioned for measurement. Repeat for each blade. The distance deviation should be equal within / "( . cm).18 032
3.If the blade wobble is still noticeable, interchanging
two adjacent (side by side) blades can redistribute the
weight and possibly result in smoother operation.
WARNING: TO REDUCE THE RI
SK OF PERSONAL
INJURY, DO NOT BEND THE
BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR
CLEANING THE FAN. DO
NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
NOISE
Ckeck Bulb to make sure it is installed correctly.
This is normal. Please allow a 24 -
hour “breaking-in” period, most noises associated with a new fan disappear during the time.
CARE AND CLEANING
1.Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to
avoid scratching the paint finish. Please make sure to turn off electricity power before you clean your fan.
2.Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the
possibility of an electrical shock.
3.Motor has permanently lubricated ball bearing. Do not need to oil fan.
NOTE: MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT
ANY CLEANING OR REPAIRS.
LIGHT IS NOT WORKING
When it is quiet (especially at night) you may hear occasional small noises.
Remove non-working bulb and replace with a bulb that is known to be a good working bulb.
To reset the remote control:Turn off power to fan using the wall switch or circuit breaker,remover batteries from
remote,wait 10 seconds,replace batteries and turn power on.
14
F8009
background

Specifications

Indexed Terms: Remote Control, Ceiling Fan

Parrot Uncle F8009BK Questions and Answers

Questions and Answers

Related Products