Technical Support and E-Warranty Certificate www.vevor.com/support
AIR BLOWER
MODEL:DL-120-M1/BL-180/CL-370-M2/CL-750-M2/
DH-120-M/BH-180/CH-370-M/CH-750-M
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only represents an
estimate of savings you might benefit from buying certain tools with us compared to the major
top brands and does not necessarily mean to cover all categories of tools offered by us. You
are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.

- 1 -
MODEL: DL-120-M1/BL-180/CL-370-M2/CL-750-M2/
DH-120-M/BH-180/CH-370-M/CH-750-M
DL-120-M1 BL-180 CL-370-M2 CL-750-M2
DH-120-M BH-180 CH-370-M CH-750-M
Have product questions? Need technical support? Please feel free to
contact us:
Technical Support and E-Warranty Certificate
www.vevor.com/support
NEED HELP? CONTACT US!
This is the original instruction, please read all manual instructions
carefully before operating. VEVOR reserves a clear interpretation of our
user manual. The appearance of the product shall be subject to the
product you received. Please forgive us that we won't inform you again if
there are any technology or software updates on our product.
Boat Fender

- 2 -
OPERATION
The air movers are intended to move air and to dry floors, carpets,walls,
furniture, etc. Durable and easy to operate with an effective balance of
static pressure and airflow, the units are suitable for a variety of
applications.
1.The air movers are shipped ready to be put into service. Prior to plugging
the unit into the power source, inspect completely for any shipping
damage.
2. Plug the electrical cord into the power outlet.
3. Carefully place the unit on a stable, flat dry surface.
4. The air mover has two or four air flow positions, capable to aim airflow
across flat surfaces or angled upward.
5. Turn the switch to desired speed and make sure it is operating correctly.
6. All air movers in operation must be supervised at all times.
PARAMETER LIST
Vol/Frequency
115V~/60Hz
Model
DL-120-M1
BL-180
CL-370-M2
CL-750-M2
Power
1/6HP
1/4HP
1/2HP
1HP
Product
Size( L*W*H)
345*250*32
0mm
330*260*
335mm
490*400*48
0mm
510*400*48
0mm
Net Weight(kg)
3.4
4.2
10.6
13.3
Vol / Frequency
230V~/50Hz
Model
DH-120-M
BH-180
CH-370-M
CH-750-M
Power
120W
180W
500W
650W
Product
Size( L*W*H)
345*250*3
20mm
340*270*3
50mm
490*400*48
0mm
510*400*48
0mm
Net
Weight(kg)
3.4
4.0
10.3
13.3

- 3 -
SWITCH PLATE
• Speed Switch
a.There are 3 fan speeds from:1,2,3.Turn clockwise to set the desired fan
speed
b.Turn to any speed position to switch the air mover ON. Turn to “OFF”
position to switch the air mover OFF
• Timer Switch (This apply for some models mentioned in this manual)
a.The timer can be set from 0 to 180 minutes.Turn clockwise to set timer
for minutes count down to an automatic stop.
b.When the timer reaches “0” position,the air mover stops working. On “ON”
position,it will work constantly
STACK MULTIPLE UNITS
• Stack the air movers on the sides. Align the air inlets of both units
• Turn the second unit 30°
DAISY CHAIN SPECIFICATIONS (FOR SOME MODELS)
• Other appliances can be plugged in the additional electrical receptacles
and work whether the air mover is on or off. However, the total amperage
must be lower than the amperage instructed.Different models may have
varying instructions
• If the air mover or the plugged in appliance stops working, press the
RESET BUTTON to reset the circuit.

- 4 -
SECURITY & WARNINGS
1. To prevent electric shock, do not operate the unit in standing water.
Never plug in or unplug the unit with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or body.
3. To reduce the risk of fire or electric shock, do not use the unit with any
solid-state speed control device.
4. Use only with GFCI or RCCB protected receptacles. Please contact a
qualified electrician for verification and / or installation of a GFCI or RCCB
receptacle if necessary.
5. Do not operate any air mover with a damaged cord or plug. Discard the
unit or return it to an authorized service facility for examination and/or
repair.
6. Unplug the Air Mover from the power supply before servicing or
cleaning.
7. Do not run the power cord under carpeting. Do not cover the power cord
with throw rugs, runners, or similar coverings. Place the power cord away
from traffic area to prevent tripping.
8. Do not allow children to play with or around an Air Mover at any time.
9. Do not move or carry an Air Mover while unit is operating.
10. All Air Movers in operation must be supervised at all times.
11. If the supply cord is damaged, it must be replaced by the manufacturer,

- 5 -
its service agent or similarly qualified persons in order to avoid a hazard.
12. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
Maintenance Instructions
1. To keep the Air Mover clean, use a damp cloth to wipe the surface of the
housing.
2. Never clean the Air Mover with water.
3.When not in use, unplug and store the Air Mover in a dry indoor place out
of reach of children.
4. Always disconnect the Air Mover from its power source before
performing any maintenance or cleaning.
CORRECT DISPOSAL
This product is subject to the provision of european Directive

- 6 -
2012/19/EU. The symbol showing a wheelie bin crossed through indicates
that the product requires separate refuse collection in the European Union.
This applies to the product and all accessories marked with this symbol.
Products marked as such may not be discarded with normal domestic
waste, but must be taken to acollection point for recycling electrical and
electronic devices.
TROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our
Service Department
PROBLEM
POSSIBLE CAUSE
SOLUTION
Air Mover not
running
No power input
Plug in the air mover;check
circuit breaker
Switch not turned on
Turn on switch
Air mover fan wheel
jammed
Remove material jamming
fan wheel
Intake or exhaust
blocked
Turn unit off and allow to
cool,then remove blockage
Air mover
vibrates
excessively
Floor is not flat
Put on a flat floor
LIMITED WARRANTY
• Warranty covers the unit from defects in materials and craftsmanship.
The Warranty covers normal use for a term of one year from the original
date of purchase.
• Warranty does not cover signs of misuse including, but not limited to, a
unit that has been dropped, subjected to water damage, tampered with,
improper voltage use and unauthorized maintenance and repairs. The
POWER CORD are not covered by the warranty.