U
n
c
l
e
P
a
r
r
o
t
C
E
ILING
F
AN
U
S
E
A
ND
C
A
R
E
G
U
I
D
E

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F3013110V
TECHNICAL INFORMATION
SKU
Nominal voltage
110V DC
15W
20W
Nominal output (motor) Light
F3013110V
( No light bulb attached )

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Thank you for purchasing this quality product. To ensure correct function and safety, please read and save all
instructions before using the product
.cleaning
THANK YOU FOR YOUR PURCHASE
SAFETY TIP
1.
To avoid possible electric shock, turn o
ff
F3013110V
the electricity at the main fuse box or circuit panel before you begin the fan installation or
before servicing the fan or installing accessories.
2. Read all instructions and safety information carefully before installing your fan and save these instructions.
3.
Make sure all electrical connections comply with local codes or ordinances and the National Electrical Code. If you are unfamiliar with
electric wiring, please use a quali
¿
ed and licensed electrician.
4.
Make sure you have a location selected for your fan that allow clear space for the blades to rotate, and at least seven (7) feet of clearance between the floor and
the fan blade tips. The fan should be mounted at least thirty (30) inches from walls or other upright structures.
5.
WARNING: The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 100 pounds. To
reduce the risk of ¿re, electric shock or personal injury, mount to the outlet box marked acceptable for fan supported and use mounting
screws provided with the outlet box. The box must be supported directly by the building structure.
6.
WARNING: To reduce the risk of
¿
re, electric shock or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting
screws provided with the outlet box most outlet boxes commonly used for the support of lighting ¿xtures are not acceptable for fan
support and may need to be replaced. Consult a quali¿ed electrician if in doubt.
7.
Electrical diagrams are for reference only. Light kits that are not packed with the fan must UL listed and marked suitable for use with the
model fan you are installing. Switches must be UL. general use switches. Refer to the instructions packaged with the light kits and
switches for proper assembly.
8.
After installation is complete, check that all connections are absolutely secure.
9.
After making electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires
should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
10.
WARNING: To reduce the risk of electrical shock and ¿re, do not use this fan with any solid-state fan speed control device, or rheostat.
11.
Do not separate the reverse switch until the fan has come to a complete stop.
12.
Do not insert anything into the fan blades while they are rotating.
13.
WARNING: To reduce the risk of personal injury, do not bend the blade brackets (also referred to as “ flanges”) during assembly or after
installation. Do not insert objects in the path of the blades.
14.
To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
15.
Do not use water or detergent when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations that may
occur. It must be understood that common sense and caution are necessary factors in the installation and operation of this fan.
NOTE: This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities are
di erent or are impaired, or lack of experience or knowledge, unless such persons are supervised or trained to operate the appliance
by a person responsible for their safety.
NOTE: Children should be supervised to ensure that they do not use appliances as a toy.

(2PCS)screwsMounting
washer (4PCS)
(4PCS)Screw
star washers(2
Spring Washer (2PCS)
PCS)
Wood
Pls check whether above accessories are copleted or not?Yes,and install.
Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
REMOTE CONTROL(1PCS)Plastic wire nut(8PCS)
Plastic wire nut (3PCS)
Decorative covers
6"ball/downrod assembly
F3013110V

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
washers
Outlet box
F3013110V

Installation & Operating Instructions for the
Finish
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F3013110V

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Use wire connecting nuts supplied with the fan
RECEIVER
(FIG.4)
CANOPY
ANTENNA PUT AT OUTSIDE
OF CANOPY BOX CAN GET
MORE OPERATION
DISTANCE
LIGHT MUST BE KEPT AT THE ON P0SITION
FAN MUST BE KEPT AT THE HIGH SPEED
FROM POWER SOURCE
AC 120 VOLT 60Hz 3.
5AMPS.
WHITE
INPUT
RED or BLACK
RECEIVER
OUTPUT
nuts connectingwireUse
remote thewithsupplied
WIRE NUT
controller.
RED
RED
BLACK
BLACK
WHITE
WHITE
F3013110V
WHITE
BLUE
WHITE
BLUE
ANTENNA

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
Turn on the power and check the operation of the fan. The fan
remote controls the fan speed as follows:
1=low speed
2=medium low speed
3=medium speed
4=medium high speed
5= high speed
6= Extra high speed
(WINTER TIME)
(SUMMER TIME)
d
A.warm weather-(Forward).
This allows you to set your air conditioner on a higher setting without
a ecting your comfort.
B.Cool weather-(Reverse)
This allows Reverse you to set heating unit on a lower setting
without affecting your comfort.
The remote control (XX) controls the direction of the blades: forward or reverse.
F3013110V

2.INSTALLING RECEIVER IN CEILING FAN
A.Safety precautions:
WARNING: HIGH VOLTAGE! Disconnect power by
removing fuse or switching off circuit breaker.
Do not use with solid state fans.
Electrical wire must meet all local and national
electrical code requirements.
Supply for fan must be 120 volt, 60Hz. Maximum fan
motor amps: 1.0,Maximum light watts: 20
incandescent or ballast and LED.
Otherwise power can cause serious injury or death.
B.lnstalling receiver in fan:
a.Remove power from the circuit.
b.Remove ceiling fan canopy from the mounting
bracket.
c.Disconnect existing wiring between ceiling fan and
Supply in electrical junction box.
d. Make connections as follows, using the wire nuts
Wiring diagram
supplied:
Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
FAN MUST BE KEPT AT THE HIGH SPEED
23(5$7,21)255(027(
二.and receiver. Turn on the supply power within
5 seconds and press the
REMOTE CONTROL“FAN ON/OFF” button for 3
seconds, it can load normally after hearing a long
sound “bee”, which means learning successfully
and it can works normally.(PS: Learning mode is
not accepted after turn “ON” the supply power for
1.Learning code matching mode is used between
REMOTE CONTROL
5 seconds)
FROM POWER SOURCE
AC 110- 120 VOLT 60Hz
Use wire connecting nuts supplied with the fan
3.5AMPS.
NUTWIRE
Use wire connecting nuts
supplied with the remote
controller.
RECEIVER
CANOPY
(FIG.4)
ANTENNA PUT AT
OF CANOPY BOX
MORE OPERATION
OUTSIDE
CAN GET
DISTANCE
AC IN L
AC IN N
OUTPUT
INPUT
F3013110V
AC/LED WHITE
RED
BLACK
WHITE
一
ANTENNA
AC/LED BLUE+
一.OPERATINGTRANSMITTER:
A. lnstall CR2032-3Vx1volt battery(included).(To
prevent damage to transmitter, remove the battery
if not used for along time).
B.Store the transmitter away from excessive heat
or humidity.C. Operating the buttons on the
panel of the transmitter.

FULLREMOTEYOUR HASNOW CONTROL OF THE FAN LIGHTAND .
OPERATION DISTANCE 20 FEET
Optional Wall Mounting for Transmitter Holder
Place in accessible area of your home, and screw the
transmitter holder into wall using the two screws
provided,slide hand unit into holder
TRANSMITTER
.
4.TROUBLE SHOOTING GUIDE1.Fails to operate
a. Power to receiver ?
b.Receiver wired correctly ?
c.Fan manual speed control in highest position ?d.Light kit switch turned on ?
e.Good battery in the transmitter ?
2.Won' t operate at distance
MAX. Motor amps: 1.0
MAX.Light watts: 180-(incandescent, or ballast non-dimmer, or LED)
If transmitter operates fan/light kit when up close,but not at 20 feet away.
NOTICE!
Your ceiling fan and light kit assembly must meet the following requirements:
1.Do not use with solid state fans.
2.Electrical rating: 120v 60Hz 3.5A
WARNING
TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITHAWALL CONTROL/SWITCH.
If other fans or supply wires are different color, have this unit installed by qualified licensed electrician.
e.Push all connected wires up into junction box.
f. Lay the black antenna wire on top of the receiver, and put the receiver into the mounting bracket.
g.Reinstall the canopy on the mounting bracket.
FCC Statement:
1. This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2)This device must accept any interference received, including interference that may cause undesired operation.
2.Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
NOTE:This equipment has been tested and found to comply with the limits for a Class B digital, pursuant to Part 15 or
the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential
installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may casue harmful interference to radio communications,
However, there is no guarantee that interference will not occur in a particular installation.If the equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
--- Reorient or relocate the receiving antenna.
--- Increase the separation between the equipment and receiver.
--- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--- Consult the dealer or an experienced radio/ TV technician for help.
h.Restore power.
o prevent damage to transmitter, remove the battery if not used for along time).
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT
Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
BREAKER
3.OPERATINGTRANSMITTER:
A. lnstall CR2032-3Vx1volt battery(included).(T
B.Store the transmitter away from excessive heat or humidity.
C. Operating the buttons on the panel of the transmitter.
F3013110V
Li ON/OFFght
Light Dimmer+
FAN ON/OFF
Time 1 Hour
Time 2 Hour
Light Dimm
+6-s p e e d 1F a n
Foward/Reverse
er-
F a n s p e e d 1 - 6 -
Time 4 Hour
Time 8 Hour
3V

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F3013110V

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WA RNING: SHUT POWER OFF AT FUSE OR CIRCUIT B REAKER
7DEOHRI&RQWHQWV
)DQ
5HPRWHLVQRWZRUNLQJ
)DQLVQRLV\
)DQ:REEOHV
3OHDVHUHIHUWRWKHLQVWUXFWLRQVKHHWIRUGHWDLOHGGLUHFWLRQVDQGGHVFULSWLRQVR I
LQVWDOODWLRQVWHSV
DQGUHTXLU HPHQWV
)$1
5(027(,6127:25.,1*
ŶƐƵƌĞƚŚĞƌĞŵŽƚĞŝƐǁŝƚŚŝŶƚŚĞϮϬ
ĨŽŽƚƌĂŶŐĞŽĨƚŚĞƌĞĐĞŝǀĞƌ
dŽƌĞƐĞƚƚŚĞƌĞŵŽƚĞĐŽŶƚƌŽůϭͿdƵƌŶŽīƉŽǁĞƌƚŽĨĂŶ
ƵƐŝŶŐƚŚĞǁĂůůƐǁŝƚĐŚŽƌĐŝƌĐƵŝƚďƌĞĂŬĞƌϮͿZĞŵŽǀĞďĂtt
tt
tt
ĞƌŝĞƐĨƌŽŵƌĞŵŽƚ Ğ
ϯͿtĂŝƚϭϬƐĞĐŽŶĚƐϰͿZĞƉůĂĐĞďĂ ĞƌŝĞƐĂŶĚƚƵƌŶƉŽǁĞƌŽŶ
ŚĞĐŬďĂ ĞƌŝĞƐƚŽ
ŝŶƐƵƌĞƚŚĞLJĂƌĞŐŽŽĚĂŶĚŽƌŝĞŶƚĞĚĐŽƌƌĞĐƚůLJ
ŚĞĐŬƚŚĞŵĂŝŶ ĂŶĚďƌĂŶĐŚĐŝƌĐƵŝƚĨƵƐĞƐŽƌďƌĞĂŬĞƌƐ
/ĨƵƐŝŶŐĂsĂƌŝĂďůĞ^ƉĞĞĚtĂůů^ǁŝƚĐŚĞŶƐƵƌĞ
ŝƚŝƐƐƉĞĐŝĮĐĂůůLJĚĞƐŝŐŶĞĚĨŽƌƵƐĞǁŝƚŚĂĐĞŝůŝŶŐĨ ĂŶ
ŚĞĐŬƚŚĞůŝŶĞǁŝƌĞĐŽŶŶĞĐtiŽŶƐƚŽƚŚĞĨĂŶĂŶĚƚŚĞ
ƐǁŝƚĐŚǁŝƌĞĐŽŶŶĞĐtiŽŶƐŝŶƚŚĞƐǁŝƚĐŚŚŽƵƐŝŶŐ
ƉĞƌƚŚĞŝŶƐƚƌƵĐtiŽŶƐ
/ĨĨĂŶƐtiůůĚŽĞƐŶŽƚǁŽƌŬƉůĞĂƐĞĐŽŶƚĂĐƚƵƐƚŽŵĞƌ^ĞƌǀŝĐĞ ^ƵƉƉŽƌƚ@ ƉĂƌƌŽƚƵŶĐůĞĐŽŵ
7+()$1,612,6<
DĂŬĞƐƵƌĞĂůůŵŽƚŽƌŚŽƵƐŝŶŐƐĐƌĞǁƐĂƌĞŐŚƚĞŶĞĚ
DĂŬĞƐƵƌĞƚŚĞƐĐƌĞǁƐƚŚĂƚĂĂĐŚĨĂŶďůĂĚĞƚŽŵŽƚŽƌĂƌĞŐŚƚ
DĂŬĞƐƵƌĞƚŚĞǁŝƌĞŶƵƚĐŽŶŶĞĐƚŽƌƐĂƌĞŶŽƚƌĂůŝŶŐĂŐĂŝŶƐƚĞĂĐŚŽƚŚĞƌŽƌƚŚĞŝŶƚĞƌŝŽƌǁĂůůŽĨƚŚĞƐǁŝƚĐŚŚŽƵƐŝŶŐ
ůůŽǁϮϰͲŚŽƵƌďƌĞĂŬŝŶƉĞƌŝŽĚDŽƐƚŶŽŝƐĞƐĂƐƐŽĐŝĂƚĞĚǁŝƚŚƚŚĞŶĞǁĨĂŶŵĂLJĚŝƐĂƉƉĞĂƌĚƵƌŝŶŐƚŚŝƐ ŵĞ
/ĨƵƐŝŶŐĂĐĞŝůŝŶŐůŝŐŚƚŬŝƚŵĂŬĞƐƵƌĞƚŚĞŐůĂƐƐǁĂƌĞŝƐƐĞĐƵƌĞĚŐŚƚůLJ
DĂŬĞƐƵƌĞƚŚĞƌĞŝƐĂƐŚŽƌƚĚŝƐƚĂŶĐĞŐĂƉĨƌŽŵƚŚĞĐĞŝůŝŶŐƚŽƚŚĞƚŽƉŽĨƚŚĞĐĂŶŽƉLJdŚĞĐĂŶŽƉLJ
ƐŚŽƵůĚŶŽƚƚŽƵĐŚƚŚĞĐĞŝůŝŶŐ
DĂŬĞƐƵƌĞLJŽƵƌĐĞŝůŝŶŐďŽdžŝƐƐĞĐƵƌĞĂŶĚƚŚĂƚƚŚĞƌƵďďĞƌŝƐŽůĂƚŽƌƉĂĚƐĂƌĞƵƐĞĚďĞƚǁĞĞŶƚŚĞŵŽƵŶŶŐďƌĂĐŬĞƚĂŶĚŽƵƚůĞƚďŽdž
dZKh>^,KKd/E''h/
ti
t
ti
ti
t
ti
ti
F3013110V

Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WA RNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREA K ER
7+()$1:2%%/(6
sĞƌŝĨLJĂůůďůĂĚĞƐĂŶĚďůĂĚĞďƌĂĐŬĞƚƐĐƌĞǁƐĂƌĞƐĞĐƵƌĞ;ŵŽƐƚĨĂŶǁŽďďůĞƉƌŽďůĞŵƐĂƌĞĐĂƵƐĞĚďLJůŽŽƐĞƉĂƌƚƐͿKŶĐĞĨĂŶŝƐ ƉƌŽƉĞƌůLJ
ŝŶƐƚĂůůĞĚƌƵŶƚŚĞĐĞŝůŝŶŐĨĂŶĨŽƌϭϬŵŝŶƵƚĞƐƚŽůĞƚƚŚĞĨĂŶƐĞůĨͲĂĚũƵƐƚ
/ĨǁŽďďůĞŽĐĐƵƌƐĂtiĞƌƌƵŶŶŝŶŐƚŚĞĨĂŶĨŽƌϭϬŵŝŶƵƚĞƐǀĞƌŝĨLJďůĂĚĞůĞǀĞůƵƐŝŶŐƚŚĞĨŽůůŽǁŝŶŐƉƌŽĐĞƐƐ
ĂͿ
ƐĞůĞĐƚĂƉŽŝŶƚŽŶƚŚĞĐĞŝůŝŶŐĂďŽǀĞƚŚĞ tiƉŽĨŽŶĞŽĨƚŚĞďůĂĚĞƐdŚĞŶƐĞůĞĐƚƚŚĞĨĂŶďůĂĚĞĂŶĚŵĞĂƐƵƌĞĨƌŽŵƚŚĞĐĞŶƚ Ğƌ
ŽĨƚŚĞƐĞůĞĐƚĞĚďůĂĚĞƚŽƉŽŝŶƚŽŶƚŚĞĐĞŝůŝŶŐZŽƚĂƚĞƚŚĞĨĂŶƵŶtiůƚŚĞŶĞdžƚďůĂĚĞŝƐƉŽƐŝtiŽŶĞĚĂŶĚƌĞƉĞĂƚ ƚŚĞ
ŵĞĂƐƵƌĞŵĞŶƚƵƐŝŶŐƚŚĞƐĂŵĞƉŽŝŶƚĨƌŽŵƚŚĞĐĞŝůŝŶŐĨŽƌĞǀĞƌLJďůĂĚĞDĞĂƐƵƌĞŵĞŶƚƐ
ƐŚŽƵůĚďĞǁŝƚŚŝŶϭϴŝŶĐŚ
ďͿ/ĨĂůůĚĞǀŝĂtiŽŶĂƌĞůĞƐƐƚŚĂŶϭϴŝŶĐŚĂŶĚƚŚĞĨĂŶĐŽŶƚŶƵĞƐƚŽǁŽďďůĞƉůĞĂƐĞĐŽŶƚĂĐƚ ƵƐƚŽŵĞƌ^ĞƌǀŝĐĞ^ƵƉƉŽƌƚ@ ƉĂƌƌ
ŽƚƵŶĐůĞĐŽŵƚŽŽƌĚĞƌĂĐŽŵƉůŝŵĞŶƚĂƌLJůĂĚĞĂůĂŶĐŝŶŐ<ŝƚ
Ͳ/ĨĂůůĚĞǀŝĂtiŽŶƐĂƌĞůĞƐƐƚŚĂŶϭϴŝŶĐŚĂŶĚƚŚĞĨĂŶĐŽŶtiŶƵĞƐƚŽǁŽďďůĞƉůĞĂƐĞĐŽŶƚĂĐƚ ƵƐƚŽŵĞƌ^ĞƌǀŝĐĞ^ƵƉƉŽƌƚ@ ƉĂƌƌŽƚƵŶĐůĞ
ĐŽŵƚŽŽƌĚĞƌĂĐŽŵƉůŝŵĞŶƚĂƌLJůĂĚĞĂůĂŶĐŝŶŐ<ŝƚ
F3013110V

AFTER INSTALLATION
The fan blades have been adjusted in the factory to minimize any wobble
NOTE:CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY
ARE MOUNTED ON A RUBBER CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE
CEILING, IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMENTERS
IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM
WOBBLE”
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING
BRACKET AND DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
For your convenience, a Balancing Kit is included; please follow this procedure when balancing the fan:
1.Check that all blade and blade arm screws are secure.
2.Most fan wobbling problems are caused when blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of one of the
blades. Measure this distance.Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. The distance deviation should be equal within
1/8"(0.32cm).
3.Use the enclosed Blade Balancing Kit if the blade
wobble is still noticeable.
4.If the blade wobble is still noticeable, interchanging two
adjacent (side by side) blades can redistribute the weight and possibly result in smoother
operation. WARNING: TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE
BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR CLEANING THE FAN. DO
NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
NOISE
When it is quiet(especially at night) you may hear occasional small noises. This is normal. Please allow
a 24-hour “breaking-in” period, most noises associated with a new fan disappear during the time.
CARE AND CLEANING
1.Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to
avoid scratching the paint nish. Please make sure to turn o electricity power before you clean your fan
2.Do not use water when cleaning your ceiling fan. It could damage the motor or the blades
and create the possibility of an electrical shock.
3.Motor has permanently lubricated ball bearing. No need to oil
NOTE: MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU
ATTEMPT ANY CLEANING OR REPAIRS.
Installation & Operating Instructions for the
Parrotuncle Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
F3013110V
ff
fi