LIVATY Lume Cosmetic wellness LED device

Product's Documents

Below are documents related to this product, you can read online or download:

User Manual

This is the main product document for model Lume.

The file format is pdf, 22 pages, you can download this manual here .

background
Lume & Care
Cosmetic wellness LED device with serums
TRANSLATION OF THE ORIGINAL USER MANUAL (GERMAN)
USER MANUAL
BEMER Int. AG | Austrasse 15 | LI-9495 Triesen | www.bemergroup.com
Tel.: +423 399 39 99 | Fax: +423 399 39 98
Document number: 765100 | Revision: 26.1 | Date: 01/2026
background
background
3
TABLE OF CONTENTS
General safety information
Hello!
Scope of delivery
Contraindications
Sensitivity self-test
Areas of application
Operating the LIVATY Lume
Recommended application
Helpful tips for best results
Charging
Cleaning instructions
Troubleshooting
Disposal
Regulatory information
Technical specications
Description of symbols
04
05
06
07
08
09
11
12
14
15
16
17
18
18
20
21
background
4
GENERAL SAFETY INFORMATION
LIVATY products are intended for cosmetic use only. They must be used in accordance
with this user manual.
Note: For detailed information on the individual serums, including ingredients and usage
instructions, please refer to the package inserts provided with each serum. This additional
information, which is not included in this user manual, must be followed carefully.
Safety Instructions
1
Do not look directly at the LED light source during use. Keep your eyes closed. For added comfort, wear the included
LIVATY Lume goggles.
2
Do not use the LIVATY Lume in combination with products such as ointments or medications unless they are specif-
ically approved for this purpose. If you are unsure, consult a healthcare professional.
3
Do not use on sunburned, hypersensitive, or inamed skin, or if you have a fever.
4
Implanted medical devices such as pacemakers and debrillators may be affected by strong magnets. If you or
anyone in your household has an implanted medical device or debrillator, do not place the LIVATY Lume near the
device. If in doubt, consult the manufacturer of the implanted device.
5
This device contains a rechargeable lithium-ion battery.
Never open or damage it, or expose it to re.
Keep the device away from direct sunlight and heat.
If you notice any unusual signs (e.g., overheating, smoke, or odor), switch off the device immediately and stop
using it.
Do not dispose of the battery in household waste. Please take the device to an appropriate collection point.
6
The LIVATY Lume can be disassembled for cleaning and rinsed under running water (IP65). Observe the markings
on the respective components and do not reach between the upper part of the LIVATY Lume device and the lower
housing shell.
7
Always use the USB-C power adapters recommended in the user manual.
8
Do not use chemical, alcohol-based, or aggressive cleaning agents.
9
Never leave the device unattended while it is switched on. The device must not be used by individuals with reduced
physical, sensory or mental capabilities, or by those lacking the necessary experience and knowledge, unless
supervised or properly instructed in its safe use. This device is not intended for use by children and must be kept out
of their reach.
10
Allow the LIVATY Lume to cool for at least 10 minutes between treatments if the ambient temperature exceeds 35°C
(95°F).
11
Do not drop the device or the Qi-Charger, as this may cause damage.
12
Do not attempt to disassemble, repair, or modify the device or the Qi-Charger yourself, and do not attempt to replace
the battery.
13
Keep the device and Qi-Charger away from heat sources and do not expose them to direct sunlight.
14
Do not expose this product or the Qi-Charger to rain or humid conditions.
15
Do not place metal objects between the device and the Qi-Charger during charging.
background
5
HELLO!
Thank you for choosing the LIVATY Lume & Care Set. This user manual
will walk you through each step, making it easy to enjoy all the features
of your LIVATY Lume with condence.
Please take a few moments to read this user manual carefully before
using your LIVATY Lume for the rst time. This will help ensure every-
thing runs smoothly, prevent any mishaps – and guarantee full warran-
ty coverage for your device.
This user manual apply to the following Lume & Care Sets. The includ-
ed serums may vary depending on the selected set.
LIVATY Lume & Care Set: 415100
LIVATY Lume & Care Set Eco Bundle Early Care: 415200
LIVATY Lume & Care Set Eco Bundle Recovery: 415300
LIVATY Lume & Care Set Eco Bundle Timeless Skin: 415400
We hope you enjoy discovering and using your LIVATY Lume!
background
6
SCOPE OF DELIVERY
LIVATY Lume
Early Care
Serum
LIVATY Lume
Clutch
Recovery
Serum
LIVATY Lume
Goggles
Timeless Skin
Serum
LIVATY Lume
Qi-Charger
Figure 1: The LIVATY Lume with accessories
Figure 2: The LIVATY serums
background
7
CONTRAINDICATIONS
Please do not use the device if you …
are taking prescription or over-the-counter medications known to increase
photosensitivity (e.g., certain antibiotics, acne treatments, or St. John’s
Wort)
have skin conditions that may be worsened by light and/or heat exposure
have suspicious or cancerous skin lesions
suffer from photosensitivity disorders or inherited eye conditions
are pregnant or breastfeeding
have injured or compromised skin, including open wounds, blisters, local
inammation, infections, bruising, or tumors
Do not use the device on moles, tattoos, or permanent makeup.
If you have recently undergone any aesthetic or medical skin treatments that
may have irritated the skin, we recommend pausing use for at least 72 hours.
When in doubt, consult a qualied professional.
If you experience any unusual reactions (e.g., pronounced redness, pain, or a
burning sensation), stop using the device immediately.
background
8
SENSITIVITY SELF-TEST
If you have very sensitive skin, we recommend testing the Lume & Care Set rst
on a small area, such as your arm.
If you notice any unusual reactions (e.g., pronounced redness, burning, or itch-
ing), stop using the device and, if necessary, consult a healthcare professional.
Switch on the LIVATY Lume (two short turns to the left or right).
Place the LIVATY Lume on your arm (see Figure 3) and carry out one complete
4-minute treatment. Then apply a small amount of serum to the treated area.
After use, check the treated area visually. If redness is present and persists for
more than two hours, this may be a sign of heightened photosensitivity. Please
consult a healthcare professional to assess your reaction.
Figure 3: Sensitivity self-test
background
9
AREAS OF APPLICATION
The RED Early Care Serum is intended for daily use on the face,
neck, and décolleté to help soften the appearance of ne lines
and early signs of aging. With regular use, it can leave the skin
feeling smooth and well cared for, while promoting a radiant,
even-toned complexion that looks visibly more balanced.
When used together with the LIVATY Lume light applicator and
the “RED” program, the serum can deliver its full cosmetic ben-
ets. The serum supports a rened complexion and a smooth,
rm, and well-nourished appearance – even without the use of
the LIVATY Lume applicator. Apply morning and evening after
cleansing.
The LIVATY RED – Early Care Serum also works as an effective
booster as part of your daily skincare routine. Afterward, simply
apply your usual skincare products and makeup as normal.
Early Care Serum
LIVATY Lume is a cosmetic wellness device that supports your daily skincare routine. It
features three different light programs, each tailored to the corresponding LIVATY serum,
to enhance their cosmetic benets and elevate your personal care experience. Used
regularly, the device may help promote a fresher complexion and a more even skin tone,
while also leaving your skin feeling pleasantly supple. For best results, use the device
together with the specially formulated LIVATY serums, available exclusively in the LIVATY
Lume & Care Set.
The LIVATY serums are formulated with carefully selected ingredients and are designed
to target specic skincare needs.
Note: The exact ingredients can be found on the package inserts included with each
serum.
background
10
The AMBER Timeless Skin Serum is formulated to provide daily
anti-aging care. Apply morning and evening to the face, neck, and
décolleté after cleansing.
When used together with the LIVATY Lume light applicator and
the “AMBER” program, the serum can deliver its full cosmetic
benets. With regular use – even without the LIVATY Lume light
applicator – the serum helps visibly reduce the appearance of
ne lines and wrinkles, leaving the skin feeling smooth and pro-
moting a fresher, more youthful-looking complexion.
The LIVATY AMBER Timeless Skin Serum can be used on its own
or as an extra layer beneath your regular day or night cream.
Makeup can be applied as normal after use.
Timeless Skin Serum
The BLUE Recovery Serum is formulated for daily use to support
a clear, smooth, and even-looking complexion. Apply morning
and evening to the face, neck, and décolleté after cleansing.
When used with the LIVATY Lume light applicator and the
“BLUE” program, the formula’s cosmetic benets can be further
enhanced. With regular use, the serum helps promote balanced,
well-cared-for skin, a more even tone, and a radiant, refreshed
look – even when used on its own without the LIVATY Lume light
applicator.
The LIVATY BLUE Recovery Serum also works as an effective
booster as part of your daily skincare routine. Afterward, you can
apply your usual skincare products and makeup as normal.
Recovery Serum
background
11
OPERATING THE LIVATY LUME
Control dial
(On/Light programs/Off)
Turn the control dial
once to the left or
right and hold briey
(approx. 2 seconds)
LIVATY Lume is
ready and dis-
plays the current
battery level
Turn the control
dial once to the
left or right
(max. 1 second)
LIVATY Lume
RED starts
Turn it again
once to the left
or right
(max. 1 second)
LIVATY Lume
BLUE starts
Turn it again
once to the left
or right
(max. 1 second)
LIVATY Lume
AMBER starts
Turn it again once to
the left or right and
hold briey
(approx. 2 seconds)
LIVATY Lume
displays the
current battery
level and then
enters standby
mode
+ 1x OFF
1x ON
+ 1x
Lume RED
+ 1x
Lume BLUE
+ 1x
Lume AMBER
1 2 3 4 5
background
12
RECOMMENDED APPLICATION
1
3
2
Cleanse your face to prepare
your skin for your LIVATY
moment.
Turn the dial again to select the light program that best suits your needs.
(see “Operating the LIVATY Lume”)
Lume AMBER
With warm, amber-
colored light
For silky smoothness
and natural luminosity
Lume RED
Visible red light and
gentle near-infrared
For enhanced vitality
and a fresh, radiant
glow
Lume BLUE
Enhanced with blue light
For soothed, balanced
skin and an even com-
plexion
Turn the control dial gently to the left or right
to switch on the LIVATY Lume – the center
light will illuminate and display the current
battery level. Your LIVATY Lume is now ready
for use.
1x ON
+ 1x
+ 1x
background
13
4
After selecting your light program, move the LIVATY Lume gently over
your face, keeping it in contact with the skin at all times. Spend about
one minute on each facial zone, moving the device slowly in circular
motions. After one minute, the device will vibrate softly – time to move
to the next zone. After four minutes, the LIVATY Lume will switch off
automatically.
Avoid looking directly into the LED light during
use and keep your eyes closed. For added
comfort, you can wear the included goggles.
Tip: If you would like to continue the treatment on your neck and décolleté,
simply restart the device.
optional
1 minute
4 minutes
OFF
1
2
3
4
background
14
5
Your skin is now perfectly prepared to absorb the serum. Choose the
serum that best suits your skin’s needs and apply one to three pumps
evenly to your face, neck, and décolleté.
For the rst visible
signs of skin aging
Restores balance to
stressed skin
For regenerated, young-
er-looking skin
Early Care
Serum after
Lume Red
Recovery
Serum after
Lume Blue
Timeless Skin
Serum after
Lume Amber
1 – 3x
Use your LIVATY Lume & Care Set twice
daily.
Only apply the Lume to clean, dry skin.
Do not use the Lume after applying
creams that contain sunscreen, as they
may reduce the effectiveness of the
light treatment.
For optimal results, always use the
LIVATY Lume in combination with the
LIVATY serums.
Clean your Lume after each use (see
cleaning instructions).
HELPFUL TIPS FOR BEST RESULTS
SCAN
FOR INFO
i
background
15
The LIVATY Lume contains a rechargeable battery designed to last for approximately one
week of use. Fully charge the LIVATY Lume before rst use.
Place the LIVATY Lume on the LIVATY Lume Qi-Charger.
Plug the USB-C charging cable from the Qi-Charger into a USB-C mains adapter (not
included), then plug the adapter into a power outlet. Use a USB-C charger with a
minimum output of 15 watts. Using a charger with a higher wattage will not harm the
device – it will only draw the amount of power it needs. Always use a charger from a
trusted manufacturer.
During charging, the center indicator pulses and the battery level is displayed.
Once the battery is fully charged, the center LED turns green and the battery level
indicator (the central ring of orange LEDs) lights up completely.
CHARGING
Figure 4: Charging the LIVATY Lume with the LIVATY Lume Qi-Charger
background
16
CLEANING INSTRUCTIONS
Twist the upper section of the LIVATY
Lume to separate it from the lower
housing shell. Overcome the magnetic
resistance and gently pull the two halves
apart. This allows you to easily access and
clean hard-to-reach areas.
After each use, wipe all exterior
surfaces of the LIVATY Lume with
a damp cloth or rinse the device
under running water to remove
any skin oil residue. Do not use
chemical or alcohol-based clean-
ing agents on the outer surfaces,
as harsh substances may discolor
the metal components.
For occasional disinfection, mild
cleaning agents or alcohol-free disinfectants (e.g., screen cleaning
wipes) can be used.
Switch off the LIVATY Lume and disconnect it from the LIVATY Lume
Qi-Charger if it is currently charging.
These cleaning instructions apply only to the Lume and not to the
Qi-Charger (which must be cleaned using a dry cloth only).
Allow the device to dry completely before using it again.
1
2
3
4
background
17
TROUBLESHOOTING
Check that the device is fully charged.
The center LED light ring should remain steadily lit when the device is switched
on.
Make sure the LIVATY Lume Qi-Charger is rmly connected to the USB power supply
unit via the USB-C plug.
The center light should pulse and the battery level should be displayed.
Ensure the adapter is securely plugged into the wall outlet.
Try a different outlet to determine whether the original outlet may be faulty.
The system is designed to switch off automatically after four minutes.
It may shut off earlier after repeated use if the device exceeds its intended operating
temperature. In this case, allow it to cool down for a few minutes, then try again.
Infrared (IR) light is invisible to the human eye. These lights may appear to be off, but
they are functioning correctly. As long as the red, visible lights are illuminated, the
device is operating as intended.
The LIVATY Lume won’t turn on
The device is not charging
The device shuts off abruptly before the four-minute treatment
is complete
Some lights appear to be off
background
18
Do not dispose of in household waste!
This product and the included Qi-Charger must not be disposed of with regular
household waste. Please take the complete device and Qi-Charger to an autho-
rized collection point for electrical and electronic equipment or return them to
your retailer.
This device contains a built-in lithium-ion battery, which will be properly re-
moved and recycled at the collection site. Do not open, damage, or incinerate
the device or Qi-Charger!
EU Declaration of Conformity
This product complies with the requirements of the following European
Directives:
2014/35/EU Low Voltage Directive
2014/53/EU Radio Equipment Directive
2014/30/EU EMC Directive
2011/65/EU RoHS Directive
The full EU Declaration of Conformity is available at:
www.livaty.com/declaration-of-conformity
FCC Statement
Contains FCC ID: YCP-32WBA5MMG01
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference
that may cause undesired operation.
Changes or modications not expressly approved by the party responsible for
compliance could void the users authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules.
DISPOSAL
REGULATORY INFORMATION
background
19
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television recep-
tion, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
IC Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may
cause undesired operation of the device.
Radiation Exposure Statement
This equipment complies with FCC and IC radiation exposure limits set forth for
an uncontrolled environment. This equipment should be charged with a mini-
mum distance of 20 cm between the radiator and your body. This transmitter
must not be co-located or operated in conjunction with any other antenna or
transmitter.
background
20
TECHNICAL SPECIFICATIONS
Product designation LIVATY Lume
Product type Wellness LED device
Operating voltage (V) 5 V
Max. power (watts) 5 W
Dimensions in mm Ø: 94, H:33
Weight (g) 180g
Type Portable device
Surface material LED light surface: shatterproof and
scratch-resistant glass
Control dial: aluminum
Housing: PC/ABS, TPE
IP degree of protection IP65
EMC class (IEC 61000-3-2) Class A
Wavelengths and number of LEDs 465 nm +/- 5 Blue (15 LEDs)
590 nm +/- 5 Amber (15 LEDs)
645 nm +/- 5 Red (17 LEDs)
850 nm +/- 10 Infrared (17 LEDs)
Maximum light energy (joules/cm2) at the
skin surface per application
Lume RED: 5 J/cm2
Lume BLUE: 7 J/cm2
Lume AMBER: 6.5 J/cm2
Intended use Intended for home use
Pulse frequency 1.2kHz, 10µT
Operating environment Temperature: 0°C to 35°C
Humidity: 15% to 90%
Air pressure: 70 kPa to 110 kPa
Qi-Charger Dimensions in mm: 56 x 56 x 5.5
Material: PC and aluminum alloy
Frequency range: 110–205 kHz
background
21
DESCRIPTION OF SYMBOLS
No. Symbol Description
1
Manufacturer
2
IP65
The device is dustproof and protected against splashing
water.
3
EU conformity marking
4
Refer to the user manual
5
Indicates that the user must consult the user manual for
important safety information, including warnings and
precautions.
6
To avoid glare, do not look directly into the light source
during operation or use of the Lume. The Lume Com-
fort Start feature ensures that only the battery level is
displayed when the device is switched on, allowing you to
select the desired light program without having to look
directly into the light source.
7
This device must not be disposed of as household waste.
Please take it to an authorized collection point (see “Dis-
posal” on page 18).