ICP 10-HALF NG 120V 1 PH AD-QS Rational SizeNatural Gas Combi Oven with Controls

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction Other Documents
  • Securityspec sheet - (English) Download
  • Rational icp 10 half e 208 240v 3 ph lm100despec sheet - (English) Download
  • R195 clxwaterfiltration - (English) Download
  • Wearableparts - (English) Download
  • Quickshipflyer - (English) Download
  • Careproducts - (English) Download
  • Pre salechecklist - (English) Download
  • Rational 1900 1158usspec sheet - (English) Download
  • Rational 8720 1560usspec sheet - (English) Download
ICP 10-HALF NG 120V 1 PH AD-QS photo

Certifiedinstallation

This is the main product document for model ICP 10-HALF NG 120V 1 PH AD-QS.

The file format is pdf, 5 pages, you can download this manual here .

background
Ensure optimal performance from your RATIONAL.
For mileage over 100 miles (200 miles round-trip) contact factory representative for Extended Travel Zone rates.
In the event that the installation visit or Pre-Installation Site Consultation visit is aborted due to the site not being ready,
the customer will be required to pay the RATIONAL Service Partner directly for any additional labor and travel charges for
subsequent visits.
Consultation, Installation or Commissioning can also be purchased directly from your RATIONAL Service Partner (RSP).
Certified Installation.
Installation Includes
Professionally reviewed and managed install process
Assembly of purchased equipment
Stacking of purchased equipment
Placement of unit
One travel trip within 100 miles (200 round trip)
Leveling of unit
Connection to existing utilities and network via LAN/WLAN within
5feet of unit
Commissioning: the operational function test at time of installation**
**Commissioning may be purchased without installation (see below)
Installation Does Not Include
Pre-Installation Site Consultation
Delivery to end user location: unit must be within 5 feet and
have a clear and unobstructed path to nal installed position
Special licensing security access delays or permits
Overtime travel or labor
Removal of packing material
Removal and scrapping of old equipment
LAN Cables or Optional RATIONAL Installation Kits
Pre-Installation Site Consultation
9999.2002 Pre-Installation Site Consultation can be purchased
with or without a RATIONAL Certified Installation.
A Certified RATIONAL technician provides an
installation consultation to ensure an efficient
installation. The service includes 100 miles (200 miles
round-trip) from the installer.
Visit (includes up to 4 cooking systems in one kitchen.)
Installation Article Numbers
9999.2200 Model XS
9999.2251 Combi-Duo XS per unit
9999.2201 iCombi/iHexagon Table-top electric
9999.2211 iCombi Table-top gas
9999.2252 Combi-Duo per unit
9999.2202 iCombi Floor electric
9999.2212 iCombi Floor gas
9999.2220 iVario Table-top standard
9999.2221 iVario Floor standard
9999.2230 iVario Table-top pressure
9999.2231 iVario Floor pressure
9999.2240 UltraVent
9999.2270 Integrated fat drain per unit
9999.2271 Water filtration per system
9999.2262 Universal stacking kit
9999.2003 Second Installation Trip (includes up to 4 cooking systems in one kitchen)
Commissioning; the operational function test when not completed by a trained technician
9999.2100 Commissioning iCombi electric
9999.2110 Commissioning iCombi gas
9999.2120 Commissioning iVario
Prices are based on business conducted during normal business hours.
background
Power Supply Electric iCombi except model XS
Electrical Junction Box Combi-Duo Electrical Junction Boxes Model XS
Single Unit
Independently Fused Power Supply Line
Combi-Duo Unit
Independently Fused Power Supply Line
NEMA 6-50R
1 Ph XS
NEMA 15-30R
3 Ph XS
Power Supply Gas iCombi
Receptacle for Single Unit Receptacles for Combi-Duo
NEMA 5-15P for 120V NEMA 6-15P* for 120V NEMA 5-15P for 120V NEMA 6-15P* for 208/240V for full-size
for half-size for full-size for half-size
Gas Models 6-half and 6-full size & 10-half size Gas Models 10-full size & 20-half size and 20-full size
3/4 inch female NPT thread, 1 ea 1 inch female NPT thread, 1 ea
Water Valve Floor Drain
3/4 inch male hose bib Y splitter for Combi-Duo* Floor Drain
(1 ea recommended) Can handle 2.1 to 5.3 gal/min
*included with RATIONAL installation kits or water filters
background
Installation Area
Gas units must be installed under a externally exhausted hood
in accordance with local regulations and standards
Electric units may require installation under a hood depending
on local regulations and standards
Deep fryers cannot be installed on the le side or at the rear of the units
Units must only be installed in frost-free rooms
Minimum clearance of 14" when there is a heat source on the le-hand
side of the unit in order to protect components; a 2" RATIONAL heat
shield accessory can be added if the distance is not achievable
Recommended distance of 20” on le-hand side of unit for carrying
out service work
Table models – if on mobile stand with exible connections that allow
unit to be moved forward while still connected to gas, electric, and
water; must maintain a minimum clearance of 2" to the le/right of
unit (for Model XS maintain a 1/2" clearance)
Floor models – must have minimum clearance of approximately
20” on the le-hand side of the unit
Electric iCombi
Installer will connect to an existing electrical junction box or disconnect; except Model XS
Each unit requires an independently fused power supply line. The Maximum Breaker Size listed below is at 125% overprotection is not required.
Devices will operate on circuit breakers at 110% overprotection.
Model XS is delivered with 5' power cable and angled plug: 1 Ph 208–240V 6–50P; 3 Ph 208–240V 15–30P
Power cable is not included with unit except XS (exible steel conduit and wiring is included with optional installation kit)
1 Ph is 3 wires (L1, L2, Ground); 3 Ph is 4 wires (L1, L2, L3, Ground)
Maximum Circuit Breaker (A) Wire Size (AWG)
Pro/Classic XS 6-half
size
6-full
size
10-half
size
10-full
size
20-half
size
20-full
size
Pro/Classic 6-half
size
6-full
size
10-half
size
10-full
size
20-half
size
20-full
size
1 Ph 208V /
1 Ph 240V
50/
50
70/
60
1 Ph 208V /
1 Ph 240V
#4
(140°F)
3 Ph 208V /
3 Ph 240V
30/
30
40/
35
80/
70
70/
60
150/
125
150/
125
250/
225
3 Ph 208V /
3 Ph 240V
#8
(140°F)
#3
(140°F)
#4
(140°F)
#2
(19F)
#1
(19F)
#4/0
(19F)
3 Ph 440V /
3 Ph 480V
20/
20
40/
35
35/
30
70/
60
70/
60
125/
125
3 Ph 440V /
3 Ph 480V
#12
(140°F)
#8
(140°F)
#8
(140°F)
#4
(140°F)
#4
(140°F)
#3
(19F)
Use copper wire only for power supply connections.
Gas iCombi
If local code does not require a GFCI receptacle or breaker than a plug can be eld wired to the supplied cord (NEMA 5-15 & NEMA 6-15 included
with optional installation kit).
To avoid nuisance tripping if a GFCI is required; then this device is approved for eld hard wiring to applicable Local and National Electrical Codes
and utility requirements.
Single Phase 6-half size 6-full size 10-half size 10-full size 20-half size 20-full size
1 Ph 120V × × × Comes with 6' Cord
1 Ph 208/240V Optional × Optional × Optional × Comes with 6' Cord
Gas Models 6-half and -full size & 10-half size
Gas shut-o valve with ¾” female NPT pipe thread connection required
Gas Models 10-full size & 20-half and -full size
Gas shut-o valve with 1” female NPT pipe thread connection required
Water
One (1) cold water shut-o valve with ¾” male garden hose thread connection per unit recommended (adapter to GHT included)
Drain
All units have a 2” OD hub connection and are supplied with a banded
seal coupling for 2” OD copper drain pipe; position of the oor drain
should not be under the unit
Model XS has a 1 1/2" OD hub connection
Preferred oor drain placement: all models - right/rear of unit
RATIONAL Certified Installation
includes final connection to
existing electrical, water, gas,
and drain connection types as
outlined below.
All connections must be within 5 feet of unit
placement or additional charges may be incurred
It is the responsibility of the customer to ensure that
all existing utility connections meet local codes and
are sized correctly
It is recommended that the customer purchase a
RATIONAL Installation Kit, which includes most items
required for a typical installation
Some installation locations will require additional
materials to be purchased by the customer
RATIONAL Certified Installation Program.
Installation Requirements.
For complete installation requirements, please see the current version of the RATIONAL Installation Manual and/or contact
RATIONAL USA Technical Support at (866) 891-3528.
background
RATIONAL Certified Installation Program.
Installation Requirements iVario.
Installation Area
Units require installation under a commercial ventilation hood that
meets the thermal load and exhaust requirements per local code.
Floor condition.
The area needs to be level for L and XL units on casters.
Service Requirements
20" space to the rear of all units is recommended for servicing for 2-S
and 2-XS (additionally for L and XL models, 20" to the right side of
the unit). If that's not available, ensure provisions for moving the unit
or the adjacent appliance on the right side. Another option is having
quick connections for water, gas, drain, and lengthening the electrical
connections with exible cords/conduits.
Nearby heat sources. Is there a heat source to the le of the unit, such
as a griddle, fryer, etc.
A minimum clearance of 14" is required on le, right and rear sides to
the heat source.
If there are open ames (broiler, range, wok etc) 20" on le, right and
rear sides.
During deep fry mode, water faucets/sources must be a minimum
of 36" or a physical wall/barrier be installed. Likewise no deep fryers
should be placed immediately next to the iVario.
Drainage. A drain trough in front of the unit is not required, please
contact a factory representative with questions.
A oor sink in the rear/side of the unit is best.
Electric iVario
Voltage is three (3) phase 208V/240V or 440V/480V (L1, L2, L3, Ground).
2-XS and 2-S units are supplied with a rear mounted junction box. A connection from this box is required. L and XL units do no include a cord and
must be wired too are not supplied with a power cable.
Installation kits are available and include exible conduit and hard wiring supplies. Using a pin and sleeve connector for the iVario is acceptable.
Current – reference spec sheet for additional information.
Circuit breaker (A) Wire Size* (AWG)
Model iVario 2-XS iVario Pro 2-S iVario Pro L iVario Pro XL Model iVario 2-XS iVario Pro 2-S iVario Pro L iVario Pro XL
3 Ph 208V /
3 Ph 240V
60 / 45 70 70 125
3 Ph 208V /
3 Ph 240V
6 / 8 6 6 2
3 Ph 440V /
3 Ph 480V
25 35 45 70
3 Ph 440V /
3 Ph 480V
14 10 8 6
Use copper wire only for power supply connections. * The specified values apply for a maximum cable length of 6 ft (2 m). Adjust the values according to the
cable length used and the local conditions and regulations.
Water
One cold water shut-o valve with ¾” male garden hose thread connection per unit recommended. (adapter to GHT included)
Units are supplied with a water hose 5'
Connect to potable drinking water
Water pressure must be between 22 psi and 87 psi. Recommended pressure of 44 psi.
Drain
Appliances are not supplied with drain pipes. Optional installation kits are available. A drain must be connected and drain to a oor sink.
Drain pipes need to be 2" high-temperature resistant pipe with constant gradient of 3° minimum, and handle maximum drainage rates of:
2-XS & 2-S ~ 4.8 gal/min, L & XL – 10.6 gal/min
All units are supplied with a banded sealing coupling to connect with 2" drain.
Preferred drain/oor sink placement viewed from the front: All models: In the rear of unit to the center or outside leg.
Floor drains must maintain an air gap per local code.
A front oor trough is not required with the iVario due to the integrated, rear exiting drain line.
For complete installation requirements, please see the current version of the RATIONAL Installation Manual and/or contact
RATIONAL USA Technical Support at (866) 891-3528.
background
Electrical Junction Box Pin and Sleeve Connector
Single Unit Sizing dependent on unit model
Independently Fused Power Supply Line
Water Valve Floor Drain
3/4 inch male hose bib Floor Drain
Can handle 4.8 gal/min for 2-XS & 2-S;
10.6 gal/min for L & XL
21.728 · DP/Ad · V-09 · 03/2025 · en_US

Specifications

Indexed Terms: Combi Oven, Natural Gas

ICP ICP 10-HALF NG 120V 1 PH AD-QS Questions and Answers