Mrcool DIYHH-18-HP-C-230D25-O DIY Hyper Heat 18,000 BTU, 1.5 Ton, 21.2 SEER2 Mini-Split Heat Pump Condenser - 230V w25 Ft. Line Set

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction Specification Other Documents
DIYHH-18-HP-C-230D25-O photo

Installation Manual

This is the main product document for model DIYHH-18-HP-C-230D25-O. Additionally, the document applies to other Mrcool models: 840255588096, DIYHH-18-HP-C-230D25-O, 12K

The file format is pdf, 44 pages, you can download this manual here .

background
MODELS:
Read this manual carefully before installation and keep it where
the operator can easily nd it for future reference.
Due to updates and constantly improving performance, the
information and instructions within this manual are subject to
change without notice.
Version Date: November 11, 2025
Please visit www.mrcool.com/documentation
to ensure you have the latest version of this manual.
This product utilizes R-454B refrigerant
DIY
®
Hyper Heat Series
Single-Zone
Mini-Split System
INSTALLATION & OWNER’S MANUAL
DIY-*-HP-WMAH-230D25-O
DIYCASSETTE*HP-230D25-O
DIYHH-*-HP-C-230D25-O
background
mrcool.com1
CONTENTS
SAFETY ..............................................................................................................................................2
UNIT OVERVIEW ...............................................................................................................................9
2.1 Packing List .........................................................................................................................9
2.2 Indoor Unit Display .........................................................................................................10
2.3 Additional Functions .......................................................................................................11
2.4 Setting Angle of Airow ...................................................................................................12
2.5 Manual Operation ............................................................................................................12
2.6 Packing & Unpacking the Unit ........................................................................................13
2.7 Operating Conditions ......................................................................................................13
INDOOR UNIT INSTALLATION ......................................................................................................14
3.1 Installation Overview ......................................................................................................14
3.2 Installation Location ........................................................................................................14
3.3 Drilling Wall Opening .......................................................................................................17
OUTDOOR UNIT INSTALLATION ..................................................................................................20
4.1 Location Selection ............................................................................................................20
4.2 Drain Joint Installation ....................................................................................................21
4.3 Anchor Outdoor Unit .......................................................................................................22
REFRIGERANT PIPING CONNECTION ..........................................................................................23
5.1 Prepare Exterior Wall Hole ............................................................................................23
5.2 Unwind Quick Connect Line Set .....................................................................................24
5.3 Connect Line Set to Indoor Unit .....................................................................................24
5.4 Connect Line Set to Outdoor Unit .................................................................................26
5.5 Opening Refrigerant Valves ............................................................................................27
5.6 Wrap Piping Connections ................................................................................................28
5.7 Connect Drain Pipe ..........................................................................................................29
ELECTRICAL CONNECTIONS .........................................................................................................30
6.1 Electrical Precautions ......................................................................................................30
6.2 Signal & Power Cable Connection ..................................................................................31
POST-INSTALLATION .....................................................................................................................33
7.1 Electrical & Gas Leak Checks ..........................................................................................33
7.2 Test Run ............................................................................................................................34
7.3 Care & Maintenance ........................................................................................................35
7.4 Troubleshooting ...............................................................................................................37
7.5 Error Display (Indoor Unit) ..............................................................................................39
7.6 Error Display (Outdoor Unit with Auxiliary Board) ......................................................40
7.7 Quick Maintenance by Error Code .................................................................................41
1
2
3
4
5
Contents
This marking indicates that this product should not be disposed with other household wastes
throughout North America. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for environmental safe recycling.
6
7
background
mrcool.com 2 2
Incorrect usage may cause serious damage or injury.
The symbols below are used throughout this manual to indicate instructions that should be
followed closely or actions that should be avoided to prevent death, injury, and/or property
damage.
Safety Precautions
CAUTION
Indicates the possibility of personal injury or loss of life.
Indicates the possibility of property damage or serious
consequences.
Read Before Using
WARNING
WARNING FOR PRODUCT INSTALLATION
INSTALLATION MUST BE PERFORMED BY AN AUTHORIZED DEALER OR SPECIALIST. DEFECTIVE
INSTALLATION CAN CAUSE WATER LEAKAGE, ELECTRICAL SHOCK, OR FIRE.
****ELECTRICAL WORK MUST BE COMPLETED BY A QUALIFIED ELECTRICAL TECHNICIAN****
DO NOT install the unit in a location that may be exposed to combustible gas leaks. If
combustiblegasaccumulatesaroundtheunit,itcouldcausere.
DO NOT turn on the power until the installation and all work has been completed.
1. Installation must be performed according to the installation instructions. Improper installation could cause
water leakage, electrical shock, or re.
2. Contact an authorized service technician for repair or maintenance of this unit.
3. This appliance must be installed in accordance with national wiring regulations.
4. Only use the included accessories, parts, and specied parts for installation. Using non-standard parts can
cause water leakage, electrical shock, re, and/or failure of the unit.
5. Install the unit in a rm location that can support the unit’s weight. If the location cannot support the unit’s
weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.
6. Install the drainage piping according to the instructions in this manual. Improper drainage could cause
water damage to your home and/or property.
7. When moving or relocating the air conditioner, consult experienced service technicians for disconnection
and re-installation of the unit.
8. For detailed information of how to install the indoor and outdoor units to their respective supports, please
refer to the indoor unit installation and outdoor unit installation sections of this manual.
9. USB device access, replacement, and maintenance operations must be carried out by professional sta.
WARNING FOR CLEANING & MAINTENANCE
1. DO NOT clean the unit with excessive amounts of water.
2. DO NOT clean the unit with combustible cleaning agents, as these could cause deformation and/or re.
3. Turn o the device and disconnect the power before cleaning. Failure to do this could result in electrical
shock.
SAFETY
1
TAKE NOTE OF FUSE SPECIFICATIONS
• The unit’s circuit board (PCB) is designed with a fuse to provide over-current protection.
• The specications of the fuse are printed on the circuit board, examples of such are T5A/250VAC and
T10A/250VAC.
Note: Only a blast-proof ceramic fuse can be used.
background
mrcool.com3
SAFETY
1
WARNING FOR PRODUCT USE
DO NOT insertngers,rods,orotherobjectsintotheairinletoroutlet.Thiscouldcauseinjury,
since the fan may be rotating at high speeds.
DO NOT useammablesprayssuchashairspray,lacquerorpaintneartheunit,asthiscould
causereand/oranexplosion.
DO NOT operate the unit in places near or around combustible gases. Emitted gas may collect
around the unit and cause an explosion.
DO NOT allow children to play with the appliance. Children must be supervised around
the unit at all times.
DO NOT operate the unit in a room where it could be exposed to excessive amounts of water,
such as a bathroom or laundry room. Exposure to excessive water amounts can cause the
electrical components to short circuit.
DO NOT exposeyourbodydirectlytodirectcoolairowfromtheunitforaprolongedperiod
of time.
1. If the unit operates abnormally (emits strange noises or a burning smell), immediately turn o the unit
and disconnect the power in order to avoid electric shock, re, and/or injury. Call your local dealer, or
MRCOOL® tech support at (270) 366-0457, for further assistance.
2. If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room
in order to avoid an oxygen deciency.
3. In certain functional environments (such as kitchens and server rooms etc.), the use of specially designed
air-conditioning units is highly recommended.
4. This appliance is not intended for use by persons(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
5. Turn o the unit and disconnect the power before performing any cleaning, installation, or repairing.
Failure to do so can cause electric shock.
ELECTRICAL WARNINGS
****ELECTRICAL WORK MUST BE COMPLETED BY A QUALIFIED ELECTRICAL TECHNICIAN****
DO NOT sharethepowersupplywithotherappliances.Animproperorinsucientpower
supplycouldcausereand/orelectricalshock.
1. Only use the specied wire. If the wire is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualied persons in order to avoid a hazard.
2. The product must be properly grounded during installation or electrical shock could occur.
3. Appropriate wiring standards, regulations, and the installation manual must be followed for all electrical
work.
4. If connecting power to xed wiring, an all-pole disconnection device must be incorporated in the xed
wiring in accordance with the wiring rules and must meet the following requirements: at least 3 mm of
clearances in all poles, a leakage current that may exceed 10 mA, and a residual current device (RCD)
having a rated residual operating current not exceeding 30 mA.
5. Connect cables tightly and clamp them securely to prevent external forces from damaging the terminal.
CAUTION
DO NOT allow the air conditioner to operate for extended periods of time with the doors or
windows open, or in very high humidity.
DO NOT operate the air conditioner with wet hands, as this could cause electric shock.
DO NOT use device for any other purpose than its intended use.
DO NOT climbontoorplaceobjectsontopoftheoutdoorunit.
1. Make sure that water condensation can drain smoothly and unhindered from the unit.
2. Turn o the unit and disconnect the power if the unit will not be used for an extended period of time.
3. Turn o and unplug the unit during storms.
background
mrcool.com 4
4
SAFETY
1
ELECTRICAL WARNINGS
6. Improper electrical connections could overheat, causing re and/or electrical shock.
7. All electrical connections must be made according to the Electrical Connection Diagram located on the
panels of the indoor and outdoor units.
8. All wiring must be properly arranged to ensure that the control board cover can close properly. If the
control board cover is not properly closed, it can lead to corrosion and cause the connection points on the
terminal to heat up, catch re, or cause electrical shock.
9. Disconnection must be incorporated in the xed wiring in accordance with the wiring rules.
FLAMMABLE REFRIGERANT WARNINGS
1. The installation of pipe-work should be kept to a minimum and should be protected from physical damage.
2. Refrigerant pipes should comply with national gas regulations.
3. All mechanical connections and ventilation openings should be kept clear of obstruction.
4. Utilize proper disposal processes based on national regulations.
5. Any person involved with working on or breaking into a refrigerant circuit should hold a current valid
certicate from an industry-accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry recognized assessment specication.
6. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of ammable refrigerants.
7. Do not use any means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer.
8. The appliance shall be stored in a room without continuously operating ignition sources (for example: open
ames, an operating gas appliance, or an operating electric heater).
9. Do not allow foreign matter (oil, water, etc.) to enter the piping, and securely seal the opening by pinching,
taping, etc.
10. Do not pierce or burn.
11. Refrigerants may not contain an odor.
12. Working procedures that aect safety should only be carried out by competent persons.
13. The unit should be stored in a well-ventilated area where the room size corresponds to the room area as
specic for operation, and should be stored so as to prevent potential mechanical damage from occurring.
14. Joints should be tested with detection equipment with a capability of 5 g/year of refrigerant or better, with
the equipment in standstill and under operation or under a pressure of at least these standstill or operation
conditions after installation. Detachable joints should NOT be used in the indoor side of the unit (brazed,
welded joint could be used).
15. A leak detection system is installed. The unit must be powered except for service. For units with a refrigerant
sensor, the indoor unit will display an error code and emit a buzzing sound, the compressor of the outdoor
unit will immediately stop, and the indoor fan will start running. The service life of the refrigerant sensor
is 15 years. When the refrigerant sensor malfunctions, the indoor unit will display the error code "FHCC".
The refrigerant sensor cannot be repaired and can only be replaced by the manufacturer. It should only be
replaced with the sensor specied by the manufacturer.
16. When a ammable refrigerant is used, the requirements for installation space of the appliance and/or
ventilation requirements are determined according to:
• The mass charge amount (M) used in the unit.
• The installation location.
• The type of ventilation of the location of the unit.
• Piping material, pipe routing, and installation must include protection from physical damage in
operation and service. This must be in compliance with local codes and standards, such as ASHRAE
15, IAPMO Uniform Mechanical Code, ICC International Mechanical Code, or CSA B52. All eld joints
must be accessible for inspection prior to being covered or enclosed.
• Protection devices, piping and ttings must be protected as much as possible against adverse
environmental eects. For example, against the danger of water collecting and freezing in relief pipes
or against accumulation of dirt or debris.
background
mrcool.com5
SAFETY
1
FLAMMABLE REFRIGERANT WARNINGS
• Piping in refrigeration systems must be designed and installed to minimize the likelihood of hydraulic
shock, resulting in damage from the system.
• Steel pipes and components must be protected against corrosion with a rust-proof coating before
applying insulation.
• Precautions must be taken against excessive vibration or movement of the unit.
• The minimum oor area of the room must be mentioned in the form of a table or a single gure
without reference to a formula.
17. After completion of eld piping for split systems, the eld pipework should be pressure tested with an inert
gas and then vacuum tested prior to refrigerant charging, according to the following requirements:
• The minimum test pressure for the low side of the system should be the low side design pressure and
the minimum test pressure for the high side of the system should be the high side design pressure,
unless the high side of the system cannot be isolated from the low side of the system in which case the
entire system should not be pressure tested to the low side design pressure.
• The test pressure after removal of pressure source shall be maintained for at least 1 hour with no
decrease of pressure indicated by the test gauge, with test gauge resolution not exceeding 5% of the
test pressure.
18. Prior to beginning work on systems containing ammable refrigerants, safety checks are necessary
to ensure that the risk of ignition is minimized. For repairs to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the system.
19. Work should be undertaken under a controlled procedure so as to minimize the risk of a ammable gas or
vapor being present while the work is being performed.
20. All maintenance sta and others working in the local area should be instructed on the nature of work being
carried out. Avoid work in conned spaces.
21. The area should be checked with an appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially ammable atmospheres. Ensure that the leak detection equipment being
used is suitable for use with ammable refrigerants, i.e. no sparking, adequately sealed, or intrinsically safe.
22. If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re
extinguishing equipment should be on site and readily available. Have a dry power or CO2 re extinguisher
adjacent to the charging area.
23. No person carrying out work in relation to a refrigerating system which involves exposing any pipe work
should use any sources of ignition in such a manner that it may lead to the risk of re or explosion. All
possible ignition sources, including cigarette smoking, should be kept suciently far away from the site
of installation, repairing, removing, and disposal, during which refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make
sure that there are no ammable hazards or ignition risks. "No Smoking" signs should be displayed.
24. Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or
conducting any hot work. A degree of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the
atmosphere.
23. Where electrical components are being changed, they shall be t for the purpose and to the correct
specication. At all times the manufacturer's maintenance ad service guidelines shall be followed. If in
doubt, consult the manufacturer's technical department for assistance. The following checks should be
applied to installations using ammable refrigerants:
• the actual refrigerant charge is in accordance with the room size within which the refrigerant containing
parts are installed;
• the ventilation machinery and outlets are operating adequately and are not obstructed;
• if an indirect refrigerating circuit is being used, the secondary circuits should be checked for the
presence of refrigerant;
• marking to the equipment continues to be visible and legible, marking and signs that are illegible
should be corrected;
• refrigerant pipe or components are installed in a position where they are unlikely to be exposed to
any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to or protected against corrosion.
background
mrcool.com 6
6
SAFETY
1
FLAMMABLE REFRIGERANT WARNINGS
24. Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it
is necessary to continue operation, an adequate temporary solution should be used.
25. Initial safety checks should include:
• that capacitors are discharged: this should be done in a safe manner to avoid the possibility of sparking;
• that there are no live electrical components and wiring are exposed while charging, recovering, or
purging the system;
• that there is continuity of earth bonding.
26. Sealed electrical components should be replaced if damaged.
27. Intrinsically safe components should be replaced if damaged.
28. Check that wiring will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or
any other adverse environmental eects. The check shall also take into account the eects of aging or
continual vibration from sources such as compressors or fans.
29. Under no circumstances should potential sources of ignition be used in the search for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked ame) should not be used. The
following leak detection methods are deemed acceptable for refrigerant systems. Electronic leak detectors
may be used to detect refrigerant leaks but, in the case of ammable refrigerants, the sensitivity may
not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-
free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant
used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and should
be calibrated to the refrigerant employed, and the appropriate percentage of gas (25% minimum) is
conrmed. Leak detection uids are also suitable for use with most refrigerants but the use of detergents
containing chlorine may react with the refrigerant and corrode the copper work. Examples of leak
detection uids are the bubble method, uorescent method agents, etc. If a leak is suspected, all naked
ames should be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of
the refrigerant should be recovered from the system, or isolated (by means of shut-o valves) in a part of
the system remote from the leak. See the following instructions of removal of refrigerant.
30. When breaking into the refrigerant circuit to make repairs, or for any other purpose, conventional
procedures should be used. However, for ammable refrigerants, it is even more vital to follow best
practice. The following procedure should be adhered to:
• safely remove refrigerant following local and national regulations;
• evacuate;
• purge the circuit with inert gas;
• evacuate;
• continuously ush or purge with inert gas when using ame to open circuit;
• open the circuit
31. The refrigerant charge should be recovered into the correct recovery cylinders if venting is not allowed by
local and national codes. For units containing ammable refrigerants, the system should be purged with
oxygen-free nitrogen to render the appliance safe for ammable refrigerants. This process might need to
be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing ammable refrigerants, refrigerant purging should be achieved by breaking the
vacuum in the system with oxygen-free nitrogen and continuing to ll the working pressure is achieved,
then venting to atmosphere, and nally pulling down to a vacuum. This process should be repeated until
no refrigerant is within the system. When the nal oxygen-free nitrogen charge is used, the system should
be vented down to atmospheric pressure to enable work to take place. The outlet for the vacuum pump
should not be close to any potential ignition sources, and ventilation should be available.
32. In addition to conventional charging procedures, the following requirements should be followed:
• Work should be undertaken with appropriate tools only (in case of uncertainty, please consult the
manufacturer of the tools for use with ammable refrigerants)
• Ensure that contamination of dierent refrigerants does not occur when using charging equipment.
Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
• Ensure that the refrigeration system is grounded prior to charging the system with refrigerant.
• Label the system when charging is complete (if not already).
background
mrcool.com7
SAFETY
1
FLAMMABLE REFRIGERANT WARNINGS
• Extreme care should be taken not to overll the refrigeration system.
• Prior to recharging the system, it should be pressure tested with oxygen-free nitrogen (OFN). The
system should be leak-tested on completion of charging but prior to commissioning. A follow-up leak
test shall be carried out prior to leaving the site.
33. Before carrying out this procedure, it is essential that the technician is completely familiar with the
equipment and all its detail. It is good recommended practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample should be taken in case analysis is
required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the
task is commenced.
a. Become familiar with the equipment and its operation.
b. Isolate the system electrically.
c. Before attempting the procedure ensure that:
• mechanical handling equipment is available, if required, for handling refrigerant cylinders;
• all personal protective equipment is available and being used correctly;
• the recovery process is supervised at all times by a competent person;
• recovery equipment and cylinders conform to the appropriate standards
Pump down refrigerant system, if possible.
e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of
the system.
f. Make sure that the cylinder is situated on the scales before recovery takes place.
g. Start the recovery machine and operate in accordance with instructions.
h. Do not overll cylinders (no more than 80% volume liquid charge).
i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
j. When the cylinders have been lled correctly and the process completed, make sure that the cylinders
and equipment are removed from the site promptly and all isolation valves on the equipment are closed o.
k. Recovered refrigerant should not be charged into another refrigeration system unless it has been
cleaned and checked.
34. Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The label
should be dated and signed. For appliances containing ammable refrigerants, ensure that there are labels
on the equipment stating the equipment contains ammable refrigerant.
35. When removing refrigerant from a system, either for servicing or decommissioning, it is good
recommended practice that all refrigerants are removed safely. When transferring refrigerant into
cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge is available. All cylinders to be used should
be designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the
recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-o
valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before
recovery occurs. The recovery equipment should be in good working order with a set of instructions
concerning the equipment that is at hand and should be suitable for the recovery of the ammable
refrigerant. If in doubt, the manufacturer should be consulted. In addition, a set of calibrated weighing
scales should be available and in good working order. Hoses should be complete with leak-free disconnect
couplings and in good condition. The recovered refrigerant should be processed according to local
legislation in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders.
36. If compressors or compressor oils are to be removed, ensure that they have been evacuated to an
acceptable level to make certain that ammable refrigerant does not remain within the lubricant. The
compressor body should not be heated by an open ame or other ignition sources to accelerate this
process. When oil is drained from a system, it should be carried out safely.
37. An unventilated area where the appliance using ammable refrigerants is installed should be constructed
so that should any refrigerant leak, it will not stagnate so as to create a re or explosion hazard. If
appliances connected via an air duct system to one or more rooms below the ventilation requirements,
that room should never contain potential ignition sources. A ame-producing device may be installed in the
space if the device is provided with an eective ame arrest. Auxiliary devices which may be a potential
background
mrcool.com 8
8
SAFETY
1
Symbols Displayed on Indoor & Outdoor Unit
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant
is leaked and exposed to an external ignition source, there is a risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with
reference to the installation manual.
CAUTION
CAUTION
This symbol shows that information is available such as the operating manual or
installation manual.
FLAMMABLE REFRIGERANT WARNINGS
potential ignition source should not be installed in the duct work. Examples of such are hot surfaces with
a temperature exceeding 1292°F (700°C) and electric switching devices. Only auxiliary devices (such as
a certied heater kit) approved by the manufacturer or declared suitable with the refrigerant should be
installed in connecting ductwork. False or drop ceilings may be used as a return air plenum if a refrigerant
detection system is provided in the appliance and any external connections are also provided with a sensor
immediately below the return air plenum duct joint. Refrigerant sensors for refrigerant detection systems
should only be replaced with sensors specied by the manufacturer. A leak detection system is installed.
The unit must be powered except for service.
38. Transport of equipment containing ammable refrigerants should comply with transportation regulations.
39. Marking of equipment using signs should comply with local regulations.
40. Disposal of equipment using ammable refrigerants should comply with national regulations.
41. Storage of equipment/appliances should be in accordance with the manufacturer's instructions.
42. Storage of packed (unsold) equipment should be constructed so that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations.
43. During the evacuation test, after achieving a vacuum level specied in the manual or less, the refrigeration
system shall be isolated from the vacuum pump and the pressure shall not rise above 1500 microns within
10 minutes. The vacuum pressure level should be specied in the manual, and should be the lessor of 500
microns of the value required for compliance with national and local codes and standards, which may vary
between residential, commercial, and industrial buildings.
• Field-made refrigerant joints indoors should be tightness-tested according to the following
requirements: the test method should have a sensitivity of 5 grams per year of refrigerant or better
under a pressure of at least 0.25 times the maximum allowable pressure. No leak should be detected.
• Any servicing should be performed only as recommended by MRCOOL®.
43. Any maintenance, service, or repair operations must be performed by qualied personnel. Every working
procedure that aects safety should only be carried out by competent persons that are both trained and
certied. The training of these procedures should be carried out by national training organizations or
manufacturers that are accredited to teach the relevant national competency standards that may be set in
legislation. All training should follow the ANNEX HH requirements of UL 60334-2-40 4th Edition.
Examples of such working procedures are:
• breaking into a refrigerant circuit
• opening of sealed components
• opening of ventilated enclosures
WARNING: PROPOSITION 65
This appliance contains berglass insulation. Respirable particles of berglass are known to the state of California to
cause cancer. Exhaust gas from this appliance contains chemicals, including carbon monoxide, known to the state
of California to cause birth defects or other reproductive harm.
background
mrcool.com9
2.1 Packing List
This system comes with the following accessories. Use all of the installation parts and accessories to
install the unit. Improper installation may result in water leakage, electrical shock and re, or cause the
equipment to fail. The items that are not included with the air conditioner must be purchased separately.
UNIT OVERVIEW
2
PART LOOKS LIKE QUANTITY
Manuals
2 (Installation
& Remote)
Mounting Plate
& Template
1
1- Metal Mounting
Plate
1 - Cardboard
Template
Remote Control 1
Drain Pipe 1
Anchor
5-8 each
(Packaged
Together)
Mounting Plate
Fixing Screw
Smart
Controller Kit
1
DIYPRO
®
Cable 1
Small Filter 2
Allen Wrench 1
Non-Adhesive
Tape
1
PART LOOKS LIKE QUANTITY
AAA Battery 2
Remote Control
Holder
1
Fixing Screw for
Remote Control
Holder
2
Insulation
Sleeve
2
Sound-
Absorbent Pads
2
Seal
1
Drain Joint
1
Plastic Wall
Sleeve & Cap
1
Quick
Connect® Line
Set
1
Neoprene
1
*For OUTTASIGHT® accessories and installation please
refer to the OUTTASIGHT® installation manual.
background
mrcool.com 10
10
2.2 Indoor Unit Display
UNIT OVERVIEW
2
Only use compatible modules certied for use with the model. Refer to the Electric Auxiliary Heat Model
specication for additional details to ensure proper selection and installation.
Display Code Display Code Meaning
• When Wireless Control feature is activated (For APP control units)
• Displays temperature, operation feature and Error codes:
(for 3 seconds)
• TIMER ON is set (if the unit is OFF, “ ” remains on when TIMER ON is set ).
• SWING, TURBO or SILENCE feature is turned on.
(for 3 seconds)
• TIMER OFF is set.
• SWING, TURBO or SILENCE feature is turned o.
• When defrosting.
• When Active Clean feature is turned on.
• When 46 F(8 C) heating feature is turned on.
background
mrcool.com11
Auto-Restart
In the event that there is a power loss, the unit will
automatically restart with the prior settings once
power has been restored.
Breeze Away
This feature avoids airow from blowing directly on
the body. The louver will set to a 35°angle. The fan will
adjust to continue to maintain a cool atmosphere in
the room.
Wireless Control(For App control units)
Allows you to control your air conditioner using your
mobile phone and a wireless connection.
Active Clean function
The Active Clean Technology washes away dust when
it adheres to the heat exchanger by automatically
freezing and then rapidly thawing the frost. This
operation is used to produce more condensed water
to improve the cleaning eect, and the cold air will
blow out. After cleaning, the internal wind wheel
then keeps operating with hot air to blow-dry the
evaporator, thus keeping the inside clean. When this
function is turned on, the indoor unit display window
appears “CL ”, after 20 to 45 minutes, the unit will turn
o automatically and cancel the Active Clean function.
Louver Angle Memory
When turning on your unit, the louver will
automatically resume its former angle.
Heat Exchanger Dust Removal Function
This feature helps keep the outdoor coil cleaner
and may extend the duration between regular
maintenance intervals depending on local conditions.
When the unit is turned o, a 10 second delay occurs
then the outdoor fan runs in reverse rotation for 70
seconds. This will blow o loose accumulated dust and
debris.
Refrigerant Leakage Detection
When the system detects a malfunction of the
refrigerant, the indoor unit will automatically display
the following error codes:
“EL0C (System lacks refrigerant )” ,
“EHC1 (Refrigerant sensor detects leakage)”,
“EHC2 (Working condition of the refrigerant sensor is
out of range and leakage is detected)”, “EHC3(Working
condition of the refrigerant sensor is out of range )”, or
“ECC1 (Other indoor unit refrigerant sensor detects
leakage (Multi-zone)”.
When “EHC1” or “EHC2” error occurs, the buzzer will
continue to beep for 5 to 6 minutes before stopping.
You can also press any button on the remote controller
to stop the buzzer.
Note: Error codes of “EHC1”, “EHC2”,“EHC3” and
“ECC1” are only applicable to the units with refrigerant
sensor.
Sleep Operation
The SLEEP function is used to maximize energy usage
while you sleep. When in COOL mode, press the SLEEP
button on remote control. The unit will increase the
temperature by 2°F (1°C) after 1 hour, and will increase
an additional 2°F (1°C) after another hour. When in
HEAT mode, the unit will decrease the temperature by
2°F (1°C) after 1 hour, and will decrease an additional
2°F (1°C) after another hour.
The sleep feature will stop after 8 hours and the
system will keep running with nal temperature
setting.
2.3 Additional Functions
Note: When the unit is powered on, a buzzing
sound will be heard to indicate that the unit has
been powered on normally. If there is no sound, it is
possible that there is a problem with the unit. If this
happens, power o and then on again. Also, check
the circuit. Check the indoor display and remote
control for your unit.
(See the Remote Controller Manual for more
features.)
UNIT OVERVIEW
2
background
mrcool.com 12
12
2.4SettingAngleofAirow
Note: While the unit is on, use the SWING/DIRECT
button (Located on the remote control) to set the
direction, or vertical angle, of airow. Please refer
to the Remote Control Manual for details. Do not
manually move the louver. To reset the louver, turn
o the unit and disconnect from power.
The horizontal angle of the airow can be set manually
or by remote control. To adjust manually, grip the
deector rod and set it to the preferred position. To
adjust my remote control, refer to the Remote Control
Manual for instructions.
DO NOT put your ngers in or near the blower and
suction side of the unit. The high-speed fan inside
the unit may cause injury.
CAUTION
When using COOL or DRY mode,
do not set louver at too vertical
of an angle for long periods of
time. This will cause the water
to condense, which will result in
water dropping below the unit.
When using COOL or HEAT
mode, setting the louver at too
small an angle can reduce the
performance of the unit due to
restricted air ow.
Set the vertical air ow louver to
it's maximum angle according
to the relative standards
requirement under heating
capacity test.
SettingHorizontalAngleofAirow
UNIT OVERVIEW
2
2.5 Manual Operation
To Operate the Unit Manually:
1. Open the front panel of the air handler. Note: If
there is a supporting rod located on the left or right
side, use that to secure to panel.
2. Locate the MANUAL CONTROL button on the right-
hand side of the unit.
3. Press the MANUAL CONTROL button one time to
activate FORCED AUTO mode.
4. Press the MANUAL CONTROL button again to
activate FORCED COOLING mode.
5. Press the MANUAL CONTROL button a third time to
turn the unit o.
6. Release the supporting rod (if included), then close
the front panel.
CAUTION
The manual button is intended for testing purposes
and emergency operation only. Please do not
use this function unless the remote control is
unavailable. To restore regular operation, use the
remote control to activate the unit. The unit must be
turned o before manual operation.
background
mrcool.com13
2.6 Packing & Unpacking the Unit
Unpacking the Indoor Unit
1. Cut the sealing tape on the carton on the left, one
cut in the middle, and one cut on the right.
2. Use a vice to take out the sealing nails on the top of
the carton.
3. Open the carton.
4. Take out the middle support plate if it is included.
5. Take out the accessory package, then take out the
connecting wire (if included).
6. Lift the machine out of the carton and lay it at.
7. Remove the packing foam, and untie the packaging
bag.
Unpacking the Outdoor Unit
1. Cut the packing belt.
2. Take the unit out of the carton.
3. Remove the foam from the unit.
4. Remove the packaging bag from the unit.
Packing the Indoor Unit
1. Place the indoor unit into the packing bag.
2. Attach the packing foam to the unit.
3. Place the unit into the carton, then add the
accessory package.
4. Close the carton can seal it with packing tape.
5. Use the packing belt, if necessary.
Packing the Outdoor Unit
1. Place the outdoor unit into the packing bag.
2. Inset the packing foam into the box.
3. Place the unit into the carton, then put the upper
packing foam on the unit.
4. Close the carton and seal it with packing tape.
5. Use the packing belt, if necessary.
UNIT OVERVIEW
2
Cool Mode Heat Mode
Room Temperature 60°F-90°F (16°C-32°C) 32°F-86°F (0°C-30°C)
Outdoor Temperature -22°F-122°F (-30°C-50°C) -22°F-75°F (-30°C-24°C)
2.7 Operating Conditions
When your unit is used outside of the following temperature ranges, certain safety protection features may
activate and cause the unit to disable.
For Outdoor Units with Auxiliary Electric Heater:
When the outside temperature is below 32°F (0°C), we strongly recommend keeping the unit plugged in at all
times to ensure smooth ongoing performance.
NOTE: Room relative humidity should be less than 80%. If the unit operates in excess of this gure, the surface
of the unit may accumulate condensation. Set the vertical air ow louver to its maximum angle (vertically to the
oor), and set the fan mode to HIGH.
To further optimize the performance of your unit, do the following:
• Keep doors and windows closed
• Limit energy usage by using the timer functions.
• Do not block air inlets or outlets.
• Regularly inspect and clean air lters.
background
mrcool.com 14
14
3.1 Installation Overview
Note: Illustrations in this manual are for explanatory purposes. The shape of your actual unit may be slightly
dierent.
1. Wall Mounting Plate
2. Front Panel
3. Louver
4. Air Filter
5. Drain Pipe
6. Connection Cable
7. Refrigerant Piping
8. Remote Control
9. Remote Control Holder
10. Outdoor Unit Power Cable
(purchase separately)
Tools NOT Included:
INDOOR UNIT INSTALLATION
3
NOTE: An air break may be required
according to local or national codes.
background
mrcool.com15
3.2 Installation Location
Note: Before you begin installation, refer to the label on the product box to make sure that the model number
of the indoor unit matches the model number of the outdoor unit.
The following standards will help you choose an appropriate location for the unit. Proper installation must meet
the following specications:
Do NOT install the unit in the following
locations:
ǿ Near any source of heat, steam, or
combustible gas.
ǿ Near ammable items such as curtains
or clothing.
ǿ Near any obstacle that might block air
circulation.
ǿ Near a doorway.
ǿ In a location that is subject to direct
sunlight.
Note for Product Installation:
When choosing a location, be aware that you should leave ample room for a wall hole (see steps for drilling a
wall hole for connecting piping) for the signal cable and refrigerant piping that connect the indoor and outdoor
units. The default position for all piping is the right side of the indoor unit (when facing the unit).
After the piping and signal wire are installed, use the provided neoprene to pack the space left in the hole, in
order to seal it and make it airtight. If preferred, spray foam can be used instead.
INDOOR UNIT INSTALLATION
3
; Firm & Solid - the location will
not vibrate & is strong enough
to support the weight of the unit.
; Noise from the unit
will not disturb
other people.
; A location at least 3.28ft
(1m) from all other
electrical devices (e.g., TV,
radio, computer)
; Good air
circulation &
ventilation.
; Convenient
Drainage
background
mrcool.com 16
16
For R454B Refrigerant Charge Amount and Minimum Room Area:
See below for unit refrigerant specications. The indoor and outdoor units are designed to be used together.
Double check for the correct specications for your purchased unit. The indoor unit should be installed at least
6.0ft/1.8m above the oor. The height of the room cannot be less than 7.3ft/2.2m. The minimum room area of
operation or storage should be according to the table below:
Amin [ft
2
/m
2
] hinst[ft/m]
mc or mREL
[oz/kg]
6.0~7.3/
1.8~2.2
7.6/2.3 7.9/2.4 8.6/2.6 9.2/2.8 9.9/3.0
<=62.6/1.776 12/1.10
63.4/1.8 60/5.53 57/5.29 55/5.07 51/4.68 47/4.35 44/4.06
70.5/2.0 67/6.15 64/5.88 61/5.64 56/5.2 52/4.83 49/4.51
77.5/2.2 73/6.76 70/6.47 67/6.2 62/5.72 58/5.31 54/4.96
84.6/2.4 80/7.38 76/7.06 73/6.76 68/6.24 63/5.8 59/5.41
91.7/2.6 86/7.99 83/7.64 79/7.32 73/6.76 68/6.28 64/5.86
98.7/2.8 93/8.6 89/8.23 85/7.89 79/7.28 73/6.76 68/6.31
105.8/3.0 100/9.22 95/8.82 91/8.45 84/7.8 78/7.24 73/6.76
112.8/3.2 106/9.83 102/9.41 97/9.01 90/8.32 84/7.73 78/7.21
119.9/3.4 113/10.45 108/9.99 104/9.58 96/8.84 89/8.21 83/7.66
126.9/3.6 120/11.06 114/10.58 110/10.14 101/9.36 94/8.69 88/8.11
134/3.8 126/11.68 121/11.17 116/10.7 107/9.88 99/9.17 93/8.56
141.1/4.0 133/12.29 127/11.76 122/11.27 112/10.4 104/9.66 97/9.01
148.1/4.2 139/12.9 133/12.34 128/11.83 118/10.92 110/10.14 102/9.46
155.1/4.4 146/13.52 140/12.93 134/12.39 124/11.44 115/10.62 107/9.91
162.2/4.6 153/14.13 146/13.52 140/12.96 129/11.96 120/11.11 112/10.37
169.2/4.8 159/14.75 152/14.11 146/13.52 135/12.48 125/11.59 117/10.82
176.3/5.0 166/15.36 159/14.69 152/14.69 140/13 130/12.07 122/11.27
Area Formula:
Amin is the required minimum room area in ft
2
/m
2
mc is the actual refrigerant charge in the system oz/kg
mREL is the refrigerant releasable charge in oz/kg
(Applicable to the unit with the refrigerant sensor only.)
hinst is the height of the bottom of the appliance
relative to the oor of the room after installation.
WARNING
The minimum room area or minimum room area of
conditioned space is based on releasable charge and
total system refrigerant charge.
When the unit detects a refrigerant leak, the minimum airow of the indoor unit is as follows:
INDOOR UNIT INSTALLATION
3
Model Indoor Unit Outdoor Unit Indoor Normal Air Volume
12K DIY-12-HP-WMAH-230D25-O DIYHH-12-HP-C-230D25-O 540m
3
/h 318CFM
12K DIYCASSETTE12HP-230D25-O DIYHH-12-HP-C-230D25-O 600m
3
/h 353CFM
18K DIY-18-HP-WMAH-230D25-O DIYHH-18-HP-C-230D25-O 800m
3
/h 470CFM
18K DIYCASSETTE18HP-230C25-O DIYHH-18-HP-C-230D25-O 680m
3
/h 400CFM
background
mrcool.com17
3.3 Drill Wall Opening
Attach Mounting Plate to Wall
Step 1:
Remove the screw that attaches the mounting plate to
the back of the indoor unit.
Step 2:
Secure the mounting plate to the wall with the screws
provided. Ensure the mounting plate is at against the
wall.
Step 3:
Determine the location of the wall hole based on the
position of the mounting plate. The dotted rectangular
box on the right gure shows the size of your product.
NOTE
A cardboard template of the mounting plate is
included to aid in installation. It can be placed
against the wall in place of the actual mounting
plate before drilling into the wall.
INDOOR UNIT INSTALLATION
3
12K Unit
18K Unit
background
mrcool.com 18
18
INDOOR UNIT INSTALLATION
3
Drill Wall Hole
Step 1:
Using a core drill with a 3.54in (90mm) diameter, drill
a hole in the wall at a slight downward angle, so that
the indoor end of the hole is higher than the outdoor
end of the hole, by approximately 0.2in to 0.275in
(5mm-7mm). This will ensure proper water drainage
from the indoor unit.
CAUTION
When drilling the wall hole, make sure to avoid
wires, plumbing, and other sensitive components.
Minimum Ceiling
Clearance
≥ 5.9 in (15cm)
Minimum Side
Clearance
≥ 4.72 in
(12cm)
Minimum Side
Clearance
≥ 4.72 in
(12cm)
Minimum Floor
Clearance
≥ 5.90 ft (1.8m)
Note for Concrete or Brick Walls:
If the wall is made of brick, concrete, or similar
material, drill 0.2in-diameter (5mm-diameter) holes in
the wall and insert the sleeve anchors provided. Then,
secure the mounting plate to the wall by tightening
the screws directly into the clip anchors.
NOTE: UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting plate
are smaller than the holes on the back of the unit. If
you nd that you don't have ample room to connect
embedded pipes to the indoor unit, the unit can be
adjusted left or right by approximately 1.18-1.96in
(30-50mm), depending on the model.
Step 2:
Insert the protective wall sleeve through the hole of
the inside wall, noting the amount it protrudes from
the exterior wall. Then, trim the excess with a utility
knife or saw to make it ush with the exterior wall.
This will protect the edges of the hole and help seal it
when you nish the installation process.
Prepare Indoor Unit Refrigerant Piping:
The piping of the indoor unit is attached to the back
of the unit towards the bottom. It will be covered with
insulation, and there will also be a drain pipe with
these. This piping will need to be bent and prepared
before it can be fed through the wall hole.
Note: Refrigerant piping should exit the indoor
unit from the right-hand side.
Step 1:
Based on the position of the wall hole, relative to the
mounting plate, determine the necessary angle the
piping will need to be bent to pass through the wall
hole when the unit is mounted to the bracket.
background
mrcool.com19
INDOOR UNIT INSTALLATION
3
Step 2:
Grip the refrigerant piping at the base of the bend.
Then, slowly, with even pressure, bend the piping
away from the back of the unit roughly 90 degrees.
The piping should be sticking straight out from
behind the unit once completed.
CAUTION
Be extremely careful not to dent or damage the
piping while bending it away from the unit, as this
could negatively aect the performance.
Step 3:
Now, you will need to lightly tape the refrigerant
piping and drain pipe together in a bundle, using
electrical tape, making sure that the drain pipe is
at the bottom. DO NOT tape the ends of the piping
(connectors). Refer to the image below for the correct
orientation of the piping when taping.
DRAIN HOSE MUST BE ON BOTTOM
The drain hose must be placed at the bottom of the
bundle. If it is not, it could cause the drain pan to
overow, which could lead to re or water damage.
Step 1:
Double-check that the ends of the refrigerant pipes
are sealed (screw on caps are still in place) to prevent
any dirt or foreign material from entering the pipes.
Mount the Indoor Unit:
In the following steps, the indoor unit will now be
mounted to the wall bracket and the piping and wires
will be fed through the wall hole.
Step 2:
Feed the DIYPRO
®
cable through the wall hole.
Step 3:
Carefully lift the indoor air handler, and slowly feed
the taped bundle of refrigerant pipes and drain hose
through the wall hole, as you position it to mount to
the wall bracket.
NOTE: Positioning the air handler onto the wall
bracket, while feeding the piping through the
wall hole, might be dicult for a single person
to manage. If so, it may be necessary to seek the
assistance of another person for this step.
Step 4:
Slightly lean the top of the air handler toward the
wall and hook the top of the indoor unit on the upper
hook of the wall mounting plate.
Step 5:
Check that the unit is hooked rmly on the mounting
plate by applying slight pressure to the left and right-
hand sides of the unit. The unit should not jiggle or
shift.
Step 6:
Using even pressure, push down on the bottom
half of the unit. Continue pushing down until the
unit snaps onto the hooks along the bottom of the
mounting plate.
Step 7:
Again, check that the unit is rmly mounted to the
wall bracket by applying slight pressure to the left
and right-hand sides of the unit.
background
mrcool.com 20
20
OUTDOOR UNIT INSTALLATION
4
4.1 Location Selection
NOTE: PRIOR TO INSTALLATION
Before installing the outdoor unit, you must choose an appropriate location. The following are standards that
will help you choose an appropriate location for the unit.
Proper Installation Locations Meet the Following Standards:
; Meets all spatial requirements shown in
Installation requirements above,.
; Protected from
prolonged periods of
direct sunlight or rain.
; Where snowfall is anticipated,
take appropriate measures to
prevent ice buildup & coil damage.
; Good air
circulation &
ventilation.
; Firm & solid-the
location can
support the unit
& will not vibrate.
; Noise from the
unit will not
disturb other
people.
NOTE: Install the unit by following local codes and regulations. These may dier slightly between dierent regions.
CAUTION: SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind:
Install the unit so that the air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in
front of the unit to protect it from extremely heavy winds.
Iftheunitisfrequentlyexposedtoheavyrainorsnow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air ow around the unit.
Iftheunitisfrequentlyexposedtosaltyair(seaside):
Use outdoor unit that is specially designed to resist corrosion.
DO NOT install the unit in the following locations:
ǿ Near an obstacle that will block air inlets & outlets.
ǿ Near a public street, crowded areas, or where noise
from the unit will disturb others.
ǿ In a location exposed to excessive amounts of salty air.
ǿ Near animals or plants that will be harmed by hot air
discharge.
ǿ Near any source of combustible gas.
ǿ In a location exposed to large amounts of dust.
background
mrcool.com21
OUTDOOR UNIT INSTALLATION
4
4.2 Drain Joint Installation
NOTE: PRIOR TO INSTALLATION
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. For the units
with base pan built-in with multiple holes for proper draining during defrost, the drain joint does not need to
be installed.
Step 1:
Find the base pan hole on the outdoor unit.
Step 2:
• Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
• Insert the drain joint into the hole in the base pan of the unit.
• Rotate the drain joint 90° until it clicks in place facing the front of the unit.
• Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during
heating mode.
NOTE: In cold climates, ensure that the drain hose is as vertical as possible to ensure swift water drainage. If
water drains too slowly, it can freeze in the hose and ood the unit.
background
mrcool.com 22
22
OUTDOOR UNIT INSTALLATION
4
4.3 Anchor Outdoor Unit
WARNING
When drilling into concrete, eye protection is recommended at all times.
• The outdoor unit can be anchored to the ground or to a wall-mounted bracket with bolts (M10). Prepare the
installation base on the unit according to the dimensions below.
• The following is a list of dierent outdoor unit sizes and the distance between their mounting feet. Prepare
the installation base of the unit according to the dimensions below.
Top View
Front View
If you will install the unit on the ground or on a
concrete platform, do the following:
1. Mark the positions for four expansion bolts based
on the dimensions chart.
2. Pre-drill holes for expansion bolts.
3. Place a nut on the end of each expansion bolt.
4. Hammer expansion bolts into the pre-drilled holes.
5. Remove the nuts from the expansion bolts, and
place the outdoor unit on the bolts.
6. Put a washer on each expansion bolt, then replace
the nuts.
7. Using a wrench, tighten each nut until snug.
If you will install the unit on a wall-mounted
bracket, do the following:
1. Mark the position of the bracket holes based on the
dimensions chart.
2. Pre-drill the holes for the expansion bolts.
3. Place a washer and nut on the end of each
expansion bolt.
4. Thread expansion bolts through holes in the
mounting brackets, put the mounting brackets in
position, and hammer expansion bolts into the
wall.
5. Check that the mounting brackets are level.
6. Carefully lift unit and place its mounting feet on the
brackets.
7. If allowed, install the unit with rubber gaskets to
reduce vibrations and noise.
CAUTION: SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
Make sure that the wall is made of solid brick, concrete, or of similarly strong material. The wall must be able to
support at least four times the unit's weight.
Outdoor Unit
Model
Outdoor Unit Dimensions
W x H x D
Mounting Dimensions
Distance A Distance B
DIYHH-12-HP-C-230D25-O 31.69in x 21.8in x 12.99in (805mm x 554mm x 330mm) 20.1in (511mm) 12.5in (317mm)
DIYHH-18-HP-C-230D25-O 35.0in x 26.5in x 13.5in (890mm x 673mm x 342mm) 26.1in (663mm) 13.9in (354mm)
background
mrcool.com23
REFRIGERANT PIPING CONNECTION
5
Step 1:
Before the refrigerant piping can be installed and
connected to the indoor and outdoor units, some
additional steps are required to prepare the exterior.
5.1 Prepare Exterior Wall Hole
Step 2:
Place your hand on the underside of the piping
coming through the exterior wall hole (from indoor
unit), close to the wall. With your other hand, using
even pressure, carefully bend the piping downward
toward the wall, being mindful not to damage or dent
the piping in the process.
CAUTION
Be extremely careful not to dent or damage the piping
while bending it down the exterior wall as this could
negatively aect the performance of the unit.
Step 3:
Pack the wall hole with the supplied neoprene (or
spray foam can also be used) to seal the hole, lling
any space that was not taken up by the refrigerant
piping and lines.
5.2 Unwind Quick Connect® Line Set
Step 1:
Use your hands to slowly unwind the copper piping
of one end of the Quick Connect® Line Set. The end
you unwind will connect to the indoor unit piping.
You should unwind the end until the connectors are
close to at on the ground (with little to no bend). If
this is not done, it could make the line set dicult to
maneuver when aligning the connectors with the air
handler piping. Only unwind as much as necessary
for your application, and allow any excess to remain
coiled.
MINIMUM BEND RADIUS:
When bending connective refrigerant piping, it needs
to have a minimum bend radius of 4 inches.
CAUTION
If the pipe is repeatedly bent or extended, it will
become hard and dicult to manipulate. Avoid
bending or extending the pipe more than 3 times, or
at an angle greater than 90°, as it could break.
background
mrcool.com 24
24
REFRIGERANT PIPING CONNECTION
5
5.3 Connect Line Set to Indoor Unit
NOTE: Depending on the capacity rating of your
unit, the wrench sizes needed will vary. Refer to the
table below (the unit uses metric sizes, the standard
sizes are approximations). Based on the availability
of wrenches in some of the sizes needed, the
recommended method is to use crescent wrenches
that can be adjusted to t the size that each step
requires.
Tools Needed:
• Open-Ended Wrench (1x of each)
12K & 18K 24K & 36K
• 3/4" (19mm)
• 7/8" (22mm)
• 15/16" (24mm)
• 1" (26mm)
• 3/4" (19mm)
• 15/16" (24mm)
• 1" (26mm)
• 1-1/8" (29mm)
• 1-1/4" (31mm)
Or 2x
Crescent
(Adjustable-
Type)
Wrenches
• 1x HVAC Torque Wrench (if available)
• 1x Allen Key (5mm)
• 1x Phillips-Head Screwdriver
• 1x leak-detection spray or a soapy water solution
(liquid detergent/mix applied by brush or spray bottle)
Refrigerant Pipe Connectors (both ends):
If the screw connections are tightened with too little
torque, they will leak. If they are tightened with too
much torque, the screw connections could suer
damage. Please refer to the torque requirements
section for more information. If you do not feel
condent connecting the line set connectors yourself,
it is imperative that you contact the MRCOOL®
customer service team or an HVAC professional.
IMPORTANT:
The line sets are designed to only be installed once.
The seal within the line set cannot be guaranteed if
they are installed more than once. This will void the
warranty. They also contain a compression tting
to seal and do not require a thread sealant (Teon
tape, etc.). Using a sealant may actually cause the
connection to leak over time.
Connecting the Quick Connect® Line Set to Indoor
Unit
1. Do not remove the plastic seals of the piping
coming from the indoor unit, or the appropriate
line set connector, until immediately before they
are to be connected. The plastic seals on each of
the connectors should be color-coded to match
the seals of the corresponding pipes they are to
be connected to.
2. Align the refrigerant pipes correctly, making sure
the dimensions of the connecting refrigerant pipe
match. Unscrew the seals and place the screw
connector of the line set just onto the threads of
the piping from the indoor unit and tighten the
rst few threads by hand.
Before you continue, it is essential that you read the
following instructions fully and carefully.
PLEASE FULLY READ BEFORE PROCEEDING TO THE
NEXT STEP.
• Follow the detailed instructions for connecting
the line set to the indoor unit and outdoor units.
• We can only provide a warranty if the line
set is installed correctly as described in the
instructions.
• To prevent leaks, ensure that the Quick Connect
®
connectors are free of dirt. Moisture or foreign
bodies will adversely aect the function of the
connectors and could lead to a risk of refrigerant
loss (not covered by the warranty).
• Only install the line set outdoors in dry weather.
• The line set must not be plastered over after
being installed.
• Always wear work gloves and googles and
use caution when handling refrigerant. Please
make sure that refrigerant is never allowed to
enter the environment. Improper handling of
refrigerant may be harmful to your health.
• The equipment must never be operated without
the line set connected, otherwise the equipment
will be damaged immediately.
• Quick Connect
®
line set connections must only
be tightened using the appropriate open-ended
or crescent (adjustable-type) wrenches.
• DO NOT remove the sealing caps and stoppers
from the line set or valves until immediately
before they are to be connected.
• DO NOT smoke during the installation.
background
mrcool.com25
REFRIGERANT PIPING CONNECTION
5
TORQUE REQUIREMENTS
1. Excessive force can break the connector or damage the refrigerant piping. You must not exceed the torque
requirements shown in the table below.
2. You can nd the outer pipe diameter stamped (in inches) on the valve set of the condenser. Refer to this when
nding and applying the torque values in the table below.
3. Please note that there may be dierences in torque wrenches (i.e. automotive torque wrench vs. an HVAC
torque wrench) and that a socket-style wrench cannot be used in this installation.
NOTE: Torque ratings in the table below are to be used if you have access to an HVAC torque wrench. These are
available for purchase from online retailers. However, it is possible to complete installation of refrigerant line
sets with conventional open-ended/crescent wrenches. It is imperative, however, that you not overtighten the
connector, and that once the lines have been fully connected, you follow the steps to check for leaks. If you do not
feel comfortable attempting this, please contact a qualied HVAC technician.
3. Using the image below as a guide, and the steps
outlined in this paragraph, you will now tighten the
nuts of the screw connectors of the line set to the
indoor unit. Using two appropriate-sized open-
ended wrenches (depending on the dimensions of
the connector) or adjustable crescent wrenches,
place one of the wrenches on the nut marked "1"
and the other wrench on the nut marked "2", as
shown in the image below. Now, turn the wrench
marked "2" in the direction of the rotational
arrows, as shown, while holding the other wrench
in place. Continue to tighten the connector until
snug.
NOTE: Work quickly and make sure the screw
connectors do not become crooked as you tighten
them.
*IfanHVACtorquewrenchisavailable:Once the
connector is snug, using the torque wrench, tighten
the connector to the specied torque rating, as listed
in the table to the right (based on pipe/coupling size).
*IfanHVACtorquewrenchisNOTavailable:Using
two wrenches you used to tighten the connector,
once the connector is snug, turn the wrench slightly
beyond that point to torque the connector, but do not
overtighten it.
4. Repeat the same process for the second line.
Stamp (on
connector)
Coupling Size
in (mm)
TighteningTorque
lb-ft (N-m)
FA06 3/8" (9.5mm)
18-20 lb/ft
(24.4-27.1 Nm)
FA09 1/2" (12.7mm)
30-35 lb/ft
(40.6-47.4 Nm)
FA12 3/4" (19.1mm)
45-50 lb/ft
(61.0-67.7 Nm)
FA16 1" (25.4mm)
60-65 lb/ft
(81.3-88.1 Nm)
CAUTION
For your safety, always wear goggles and work gloves
when connecting the pipes.
Capacity
(Btu/h)
Standard
Length
Max. Pipe Length Max Elevation
12k
24.6ft
(7.5m)
82ft (25m) 49.2ft (15m)
18K 98.4ft (30m) 65.6ft (20m)
Line Set Maximum Run Length
background
mrcool.com 26
26
REFRIGERANT PIPING CONNECTION
5
5.4 Connect Line Set to Outdoor Unit
1. First remove the water tray on
the outdoor unit as shown in
the illustration to the right.
2. Do not remove the plastic seals from the outdoor
unit piping connectors and corresponding
refrigerant pipes (line set to be attached) until
immediately before you connect them.
NOTE: Ensure the adapters attached to the
outdoor valves have been tightened properly
before attempting to connect the line set.
3. Align the refrigerant pipes so they line up with
the corresponding valves and have enough slack.
NOTE: The refrigerant pipes must be connected
to the valves with as little stress as possible.
Unscrew the plastic seals and place the screw
connector of the refrigerant line just onto the
threads of the outdoor unit, tightening the rst few
threads by hand.
4. Using the rst of the following images as a guide,
you will now tighten the line set to the outdoor
unit. Using two appropriate sized open-ended
wrenches (depending on the dimensions of the
connector), or adjustable crescent wrenches, place
one of the wrenches on the nut marked "1", and
the other wrench on the nut marked "2". Now,
turn the wrench on nut "2" in the direction of the
rotational arrow, while holding the other wrench
in place, as seen in the rst image. Continue to
tighten the connector until snug. NOTE: Work
quicklyandmakesurethescrewconnectorsdo
not become crooked as you tighten them.
*IfanHVACtorquewrenchisavailable: Once the
connector is snug, using the torque wrench, tighten
the connector to the specied torque rating, listed
in the table on the next page (based on the pipe/
coupling size).
*IfanHVACtorquewrenchisNOTavailable:Using
the two wrenches you used to tighten the connector,
once the connector is snug, turn the wrench slightly
beyond that point to torque the connector but do not
overtighten it.
IMPORTANT
Before you continue, it is essential that you read the
following instructions carefully.
5. Repeat the same process for the top screw
connector, using the second image below as a
guide. Then, repeat all of these steps for every line
set for all other air handlers to be connected.
IMPORTANT
The coupling of the outdoor unit uses tapping rings. If
you disconnect and reconnect the refrigerant pipes, it
could cause it to leak. This will also void the warranty.
NOTE: Keep excess refrigerant hose coiled. Wrap
with protective tape and store behind the condenser
in a horizontal position (at with the ground).
background
mrcool.com27
INDOOR UNIT INSTALLATION
3
TORQUE REQUIREMENTS
1. Excessive force can break the connector or damage the refrigerant piping.
You must not exceed the torque requirements shown in the table below.
2. You can nd the outer pipe diameter stamped (in inches) on the valve set of
the condenser. Refer to this when nding and applying the torque values in
the table below.
3. Please note that there may be dierences in torque wrenches (i.e.
automotive torque wrench vs. an HVAC torque wrench) and that a socket-
style wrench cannot be used in this installation.
NOTE: Torque ratings in the table below are to be used if you have access
to an HVAC torque wrench. These are available for purchase from online
retailers. However, it is possible to complete installation of refrigerant line sets
with conventional open-ended/crescent wrenches. It is imperative, however,
that you not overtighten the connector, and that once the lines have been
fully connected, you follow the steps to check for leaks. If you do not feel
comfortable attempting this, please contact a qualied HVAC technician.
Stamp
(on
connector)
Coupling
Size
in (mm)
Tightening
Torque
lb-ft (N-m)
FA06
3/8"
(9.5mm)
18-20 lb/ft
(24.4-27.1 Nm)
FA09
1/2"
(12.7mm)
30-35 lb/ft
(40.6-47.4 Nm)
FA12
3/4"
(19.1mm)
45-50 lb/ft
(61.0-67.7 Nm)
FA16
1"
(25.4mm)
60-65 lb/ft
(81.3-88.1 Nm)
5.5 Opening Refrigerant Valves
1. Using the images below as a guide, remove the
cover on the top valve, using a 19mm open-ended
wrench or a crescent (adjustable-type) wrench.
Then, insert a 5mm Allen key and open the valve
by turning it counter-clockwise as far as it will go.
DO NOT force it. The valve is now open. Screw the
cover back onto the top valve and tighten it well to
ensure that it is properly sealed.
2. Using the images below as a guide, repeat the
same process for the bottom valve. Remove the
cover on the bottom valve, using a 19mm open-
ended wrench or a crescent (adjustable-type)
wrench. Then, insert a 5mm Allen key and open
the valve by turning it counter-clockwise as far as it
will go. DO NOT force it. Screw the cover back onto
the bottom valve and tighten it well to ensure that
it is properly sealed.
CAUTION
If the King Valves are not fully opened, the system could malfunction and suer damage.
background
mrcool.com 28
28
INDOOR UNIT INSTALLATION
3
3. You will now need to check all of the piping connections (at indoor unit and outdoor unit) for leaks. You can
do this by using leak detection spray, or applying a soapy water solution (liquid detergent/water mixture) to
the connection via a spray bottle or brush. If any bubbles begin to form, that indicates there is a leak, and the
connection needs to be re-tightened. Tighten the connection and recheck it for leaks. Refer to the Electrical
and Gas Leak Checks section of this manual for more information.
IMPORTANT: You will be asked to check for leaks at the piping connections multiple times throughout the following
steps of the installation, because the pressures within the lines will change once the unit is turned on and this
could reveal leaks not present during the initial check. These are imperative to make sure your connections are not
allowing refrigerant to escape the system. When checking for leaks, if any bubbles form, it indicates the system has
a leak and the screw connector needs to be re-tightened.
5.6 Wrap Piping Connections
Step 1:
Use the sound-absorbent pads to prevent the quick-
connector parts from being exposed to the air. Wrap
the quick-connectors with the sound-absorbent pads
tightly.
Step 2:
Wrap the connectors with the black insulation
material. For the exposed portion on the top, use
the supplied white insulation material to wrap it up
completely.
background
mrcool.com29
Step 3:
Now, starting where the line set is not covered with
the factory plastic (close to the indoor air handler
connection, you will wrap the line set upward to the
wall hole, using the supplied non-adhesive U.V. tape.
This will cover the insulated line set connections,
cables, and drain hose. The drain pipe will need to be
at the bottom of the bundle. Do not wrap the end of
the drain hose.
INDOOR UNIT INSTALLATION
3
If you would like the exterior piping on the side of
your home to have a sleeker, more attractive look
and add extra protection in the process, you can
purchase a line set cover separately. This will encase
your refrigerant piping and lines, protecting them
from harsh weather conditions and sun exposure,
which will extend the life of your system. These
covers are available in various sizes to t your
particular application.
5.7 Connect Drain Pipe
In this step you will connect the drain hose extension
to the drain hose exiting from the indoor unit that is
within the piping bundle you wrapped in the previous
steps.
1. Securely connect the drain hose extension to the
drain piping from the indoor unit.
2. Use the rst example in the following images
to make sure your drain pipe is run in a similar
manner. The other examples represent things you
should avoid when installing your drain pipe.
3. Remove the air lter from the indoor unit and
pour a small amount of water across the coils to
test the drain pan. Ensure that the water exits the
bottom of the unit and ows through the drain
and drain pipe smoothly.
CAUTION
Make sure to arrange the drain hose correctly
according to the following images.
• DO NOT kink the drain hose.
• DO NOT create a water trap.
• DO NOT put the end of the drain hose in water
or a container that will collect water.
background
mrcool.com 30
30
ENSURE DRAIN HOLE IS PLUGGED
As shown in the gure above, there are two
drain holes on the indoor unit: one on the left,
and one on the right. The unit arrives with the
drain hose connected to the left hole and a
hollow center rubber plug in the right. Connect
the drain hose to the drain hole that best
works for your installation location. To prevent
unwanted leaks, be sure that the plug is installed
in the unused drain hole. The plug is depicted in
the right hole in the gure.
6.1 Electrical Precautions
WARNING
• Before performing any electrical work, read the following regulations and disconnect the main power to
the system.
• All wiring must be performed strictly in accordance with the wiring diagram located on the back of the
indoor unit's front panel.
1. All wiring must comply with local and national
electrical codes, regulations, and must be
installed by a licensed electrician.
SELECT THE CORRECT CABLE
• See the table below for gauge requirements.
NOTE: The table below is a standard chart, the
AWG ratings and wiring needs will change based
on wire length and temperature.
DO NOT MIX LIVE AND NULL WIRES.
This is dangerous, and can cause the unit to
malfunction.
2. All electrical connections must be made according
to the Electrical Connection Diagram located on
the panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power
supply, stop work immediately. Explain your
reasoning to the client, and refuse to install the
unit until the safety issue is properly resolved.
4. If connecting power to xed wiring, a surge
protector and main power switch should be
installed.
5. Only connect the unit to an individual branch
circuit outlet. Do not connect another appliance
to that outlet.
6. Make sure to properly ground the unit.
7. Every wire must be rmly connected. Loose wiring
can cause the terminal to overheat, resulting in
product malfunction and possible re.
8. Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
9. To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned o. After turning o the
power, always wait 10 minutes or more before
you touch the electrical components.
ELECTRICAL CONNECTIONS
6
Capacity
(Btu/h)
Power Supply
Amperage AWG
MCA MOP Min.
12K
208/230V~, 60Hz, 1
Phase
15 15 12
18K 19 25 12
* Wire size is a recomendation based on the MCA, always
follow local codes and inspector recomendations.
background
mrcool.com31
The signal cable enables communication between the indoor and outdoor units. You must rst choose the right
cable size before preparing it for connection.
NOTE: Choose the cable type according to local electrical codes and regulations. Please choose the right cable
size according to the Minimum Circuit Ampacity located on the nameplate of the unit.
ConnectionDiagram(208/230V)
1. Open the front panel of the indoor unit.
2. Using a screwdriver, open the wire box cover on the right side of the unit. This will reveal the terminal block.
3. Facing the back of the unit, remove the large plastic knock-out panel to create a slot through which the
conduit tube can be installed.
NOTE: For units with ve-core cable, remove the small, middle plastic knock-out panel to create a slot through
which the cable can exit. Use needle-nose pliers if the plastic panel is too dicult to remove by hand.
4. As shown in the illustration, insert the wires including the ground wire into the conduit and secure them with
a lock nut onto the conduit mounting plate.
5. Match wire colors with terminal numbers on the indoor and outdoor unit's terminal blocks and rmly screw
the wires to the corresponding terminals.
6. Connect the ground wires to the corresponding terminals.
7. Pull the wires and check that the wires are securely xed to the terminal block.
ELECTRICAL CONNECTIONS
6
6.2 Signal & Power Cable Connection
NOTE: The indoor unit arrives pre-wired from the factory. Use the following steps if wiring work is needed.
background
mrcool.com 32
32
ELECTRICAL CONNECTIONS
6
WARNING
Before operation of the unit:
• All wiring work must be performed strictly in accordance with the wiring diagram located inside the wire
cover of the outdoor unit.
• Before performing any electrical or wiring work, turn o the main power to the system.
1. Remove the screws from the electrical wiring
cover from the outdoor unit and remove it.
2. Remove the retaining nut from the DIYPRO
®
cable
that you fed through the wall hole earlier in the
installation.
3. Pull the end of the DIYPRO
®
cable through the
hole of the electrical cover (removed in step 1).
4. Now, secure the DIYPRO
®
cable to the electrical
cover by pushing the treaded end of the cable
into the hole and reinstalling the retaining nut
previously removed onto the end of the cable.
background
mrcool.com33
POST-INSTALLATION
7
7.1 Electrical & Gas Leak Checks
WARNING-RISK OF ELECTRIC SHOCK
All wiring must comply with local and national electrical codes and must be installed by a licensed electrician.
Electrical Safety Checks
After installation, conrm that all electrical wiring is installed in accordance with local and national regulations,
and according to the installation manual.
Gas Leak Checks
There are two dierent methods to check for gas leaks.
Soap & Water Method:
Using a soft brush, apply soapy water or liquid detergent to all pipe connection points on the indoor unit and
outdoor unit. The presence of bubbles indicates a leak.
Leak Detector Method:
If using a leak detector, refer to the device's operation manual for proper usage instructions.
AFTER PERFORMING GAS LEAK CHECKS:
After conrming that all of the pipe connection points do not leak, replace the valve cover on the outside unit.
5. Then, you will connect the wires to the terminal
block. Each wire should be numbered and
correspond with a connection port on the
terminal block. Match up each wire with the
correct port, and rmly screw the u-lug of each
wire to its corresponding terminal. Now, screw
the ground wire into the bottom screw of the
terminal block, as shown in the image below.
6. Finally, reinstall the electrical wiring cover and
secure it by reinstalling the screws you previously
removed.
background
mrcool.com 34
34
POST-INSTALLATION
7
BEFORE TEST RUN
Only perform the test run after you have completed
the following steps:
• Electrical Safety Checks - Conrm that the unit's
electrical system is safe and operating properly.
• Gas Leak Checks - Check all are nut connections
and conrm that the system is not leaking.
• Conrm that gas and liquid (high and low
pressure) valves are fully open.
7.2 Test Run
You should perform the test run for at least 30
minutes.
• Connect power to the unit.
• Press the ON/OFF button on the remote control to
turn it on.
• Press the MODE button to scroll through the
following functions, one at a time:
-Cool: Select lowest possible temperature
-Heat: Select highest possible temperature
• Let each function run for 5 minutes, and perform
the following checks:
Checks to Perform Pass/Fail
No electrical leakage
Unit is properly grounded
All electrical terminals are
properly covered
Indoor & outdoor units are
solidly installed
All pipe connection points
do not leak
Indoor (2): Outdoor (2):
Water drains properly from
drain hose
All piping is properly
insulated
Unit performs cool function
properly
Unit performs heat function
properly
Indoor unit louvers rotate
properly
Indoor unit responds to
remote control
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the refrigerant
circuit will increase. This may reveal leaks that were
not present during your initial leak check. Take
time during the Test Run to double-check that all
refrigerant pipe connection points do not have
leaks. Refer to the Gas Leak Checks section for
instructions.
After the test run is successfully completed, and you
conrm that all check points in the list have passed, do
the following:
• Using the remote control, return unit to normal
operating temperature.
• Using insulation tape, wrap the indoor refrigerant
pipe connections that you left uncovered during
the indoor unit installation process.
If Ambient Temperature is Below 60°F (16°C):
You can't use the remote control to turn on the
cool function when the ambient temperature is
below 60°F (16°C). In this instance, you can use the
MANUAL CONTROL button to test the cool function.
• Lift the front panel of the indoor unit, and raise it
until it clicks in place.
• The MANUAL CONTROL button is located on the
right-hand side of the unit. Press it 2 times to
select the COOL function.
• Perform the test run as normal.
background
mrcool.com35
7.3 Care & Maintenance
CAUTION
• Clean the lter on your unit every two weeks. Failing to do so can lead to reduced cooling eciency or damage
to your health.
• Always turn o the system and disconnect its power supply before cleaning or maintenance.
• Do not touch the lter within 10 minutes after turning o the unit.
• Only use a soft, dry cloth to wipe the unit clean. You can use a cloth soaked in warm water to wipe it clean if the
unit is especially dirty.
• Do not use chemicals or chemically treated cloths to clean the unit.
• Do not use benzene, paint thinner, polishing powder, or other solvents to clean the unit. They can cause the
plastic surface to crack or deform.
• Do not use water hotter than 104°F (40°C) to clean the front panel. This can cause the panel to deform or
become discolored.
Cleaning the Air Filter
Step 1:
Lift the front panel of the indoor unit. For the unit with
a supporting rod, use it to prop up the front panel.
Step 2:
Grip the tab on the end of the lter, lift it up, then pull
it towards you and pull the lter out.
1. Flip to back 2. Remove air
freshening lter
3. Clean with
hand-held vacuum
Step 3:
If your lter has a small air freshening lter, unclip it
from the larger lter. Clean this air freshening lter
with a hand-held vacuum.
Step 4:
Clean the large air lter with warm, soapy water. Be
sure to use a mild detergent. Rinse the lter with fresh
water, then shake o excess water. Dry it in a cool, dry
place, and refrain from exposing it to direct sunlight.
Step 5:
When dry, re-clip the air freshening lter to the larger
lter, then slide it back into the indoor unit. Finally,
close the front panel of the indoor unit.
POST-INSTALLATION
7
background
mrcool.com 36
36
CAUTION
• Before changing the lter or cleaning, turn o the unit and disconnect its power supply.
• When removing the lter, do not touch metal parts in the unit. The metal edges are sharp.
• Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
• Do not expose the lter to direct sunlight when drying. This can shrink the lter.
• Any maintenance and cleaning of the outdoor unit should be performed by an authorized dealer or a licensed
service provider.
• Any unit repairs should be performed by an authorized dealer or service provider.
Maintaining the Unit
Long Periods of Non-Use
If you plan not to use the unit for an extended period
of time, do the following:
Clean all lters.
Turn on fan function
until unit dries out
completely.
Turn o the unit &
disconnect the power.
Remove batteries
from remote control.
Pre-Season Inspection
After long periods of non-use, or before periods of
frequent use, do the following:
Clean all lters.
Check for damaged
wires.
Check for leaks.
Ensure nothing is blocking the air inlets & outlets.
Replace batteries.
POST-INSTALLATION
7
background
mrcool.com37
CAUTION
If any of the following conditions occur, turn o the unit immediately.
• The wire is damaged or abnormally warm.
• You smell a burning odor.
• The unit emits loud or abnormal sounds.
• A power fuse blows or the circuit breaker frequently trips.
• Water or other objects fall into or out of the unit.
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY.
7.4 Troubleshooting
The following problems are not a malfunction, and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn on when
pressingON/OFFbutton.
The unit has a 3-minute protection feature that prevents the unit from overloading.
The unit cannot be restarted within 3 minutes of being turned o.
TheunitchangesfromCOOL/
HEAT mode to FAN mode.
The unit may change its setting to prevent frost from forming on the unit. Once the
temperature increases, the unit will start operating in the previously selected mode
again.
The set temperature has been reached, at which point the unit turns o the
compressor. The unit will continue operating when the temperature uctuates again.
The indoor unit emits white
mist.
In humid regions, a large temperature dierence between the room's air and the
conditioned air can cause white mist.
Both the indoor and outdoor
units emit white mist.
When the unit restarts in heat mode after defrosting, white mist may be emitted due
to moisture generated from the defrosting process.
The indoor unit makes noises.
A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in heat mode due to expansion
and contraction of the unit's plastic parts.
Both the indoor unit and the
outdoor unit make noises.
Low hissing sound during operation: this is normal and is caused by refrigerant gas
owing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting:
This noise is normal and is caused by the refrigerant gas stopping or changing
direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises. The unit will make dierent sounds based on its current operating mode.
Dust is emitted from either the
indoor or outdoor unit.
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.
The unit emits a bad odor.
The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operation.
The unit's lters have become moldy and should be cleaned.
The fan of the outdoor unit
does not operate.
During operation, the fan speed is controlled to optimize product operation.
Operation is erratic,
unpredictable, or the unit is
unresponsive.
Interference from cell phone towers and remote boosters may cause the unit to
malfunction.
In this case, try the following:
• Disconnect the power, then reconnect.
• Press the ON/OFF button on the remote control to restart operation.
Note: If a problem persists, contact a local dealer or MRCOOL® customer service. Provide them with a detailed description of
the unit malfunction as well as your model number.
POST-INSTALLATION
7
background
mrcool.com 38
38
CAUTION
Before contacting a repair company, check the following points.
Problem Possible Causes Solution
Poor Cooling
Performance
Temperature setting may be higher
than ambient room temperature.
Lower the temperature setting.
The heat exchanger on the indoor or
outdoor unit is dirty.
Use the Clean function by remote control to clean the
aected heat exchanger.
Theairlterisdirty. Remove the lter and clean it according to instructions.
The air inlet or outlet of either unit is
blocked.
Turn the unit o, remove the obstruction and turn it back
on.
Doors and windows are open.
Make sure that all doors and windows are closed while
operating the unit.
Excessive heat is generated by
sunlight.
Close windows and curtains during periods of high heat
or bright sunshine.
Too many sources of heat in the room
(people, computers, electronics, etc.)
Reduce the amount of heat sources.
Low refrigerant due to leak or long-
term use.
Check for leaks, re-seal if necessary, and top o
refrigerant.
Silence function is activated (optional
function)
Silence function can lower product performance by
reducing operating frequency. Turn o Silence function.
The unit is not
working
Power failure Wait for the power to be restored.
Thepoweristurnedo. Turn on the power.
The fuse is burned out. Call a technician to replace the fuse.
Remote control batteries are dead. Replace batteries
The unit's 3-minute protection has
been activated.
Wait three minutes after restarting the unit.
Timer is activated. Turn timer o.
The unit starts and
stopsfrequently.
There's too much or too little
refrigerant in the system.
Call a technician to check for leaks and recharge the
system with refrigerant.
Incompressible gas or moisture has
entered the system.
Call a technician to evacuate and recharge the system
with refrigerant.
The compressor is broken. Call a technician to replace the compressor.
The voltage is too high or too low. Install a manostat to regulate the voltage.
Poor heating
performance
The outdoor temperature is
extremely low.
Use auxiliary heating device.
Cold air is entering through doors and
windows.
Make sure that all doors and windows are closed during
use.
Low refrigerant due to leak or long-
term use.
Call technician to check for leaks, re-seal if necessary, and
top o refrigerant.
Indicator lamps
continueashing
The unit may stop operation or continue to run safely. If the indicator lamps continue to ash or
error codes appear, wait for about 10 minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on. If the problem persists,
disconnect the power and contact MRCOOL®.
Error code appears
and begins with
the following
letters in the
display area:
E(x), P(x), F(x), EH(xx),
EL(xx), EC(xx), PH(xx),
PL(xx), PC(xx)
Note: If the problem persists after performing the checks and diagnostics above, turn o the unit immediately and contact
MRCOOL®.
POST-INSTALLATION
7
background
mrcool.com39
POST-INSTALLATION
7
7.5 Error Display (Indoor Unit)
When the indoor unit encounters a recognized error, an error code will be displayed; the error codes are
described in the tables below:
Display Error Information
DF
Defrost
Cl
Active Clean
FP
Heating in Room Temperature under 46.4°F (8°C)
FC
Forced Cooling
AP
AP Mode of Wi Connection
CP
Remote Switched O
EH 00
IDU EEPROM Malfunction
EH 0A
Indoor EEPROM Parameter Error
EL 01
IDU & ODU Communication Error
EH 02
Zero-Crossing Signal Detection Error
EH 03
IDU Fan Speed Out of Control
EC 51
ODU EEPROM Parameter Error
EC 52
ODU Coil Temperature Sensor (T3) Error
EC 53
ODU Ambient Temperature Sensor (T4) Error
EC 54
Comp. Discharge Temperature Sensor (TP) Error
EC 56
IDU Coil Outlet Temperature Sensor (T2B) Error (Multi-Zone)
EH 60
IDU Room Temperature Sensor (T1) Error
EH 61
IDU Pipe Temperature (T2) Sensor Error
EC 07
ODU Fan Speed Out of Control
EH 0B
IDU Main Control Board & Display Board Communication Error
FH CC
Refrigerant Sensor Error
EH C1
Refrigerant Sensor Detects Leakage
EH C2
Refrigerant Sensor is Out of Range & Leakage is Detected
EH C3
Refrigerant Sensor is Out of Range
EC C1
Other IDU Refrigerant Sensor Detects Leakage (Multi-Zone)
EL 0C
System Lacks Refrigerant
PC 00
ODU IPM Module Protection
PC 01
ODU Voltage Protection
PC 02
Compressor Top (or IPM) Temperature Protection
PC 04
Inverter Compressor Drive Error
PC 03
Pressure Protection (low or high pressure)
PC 0L
Low Ambient Temperature Protection
----
IDUs Mode Conict (Multi-Zone)
For other errors:
The display board may show a garbled code or a code
undened by the service manual. Ensure that this
code is not a temperature reading.
Troubleshooting:
Test the unit using the remote control. If the unit does
not respond to the remote, the indoor PCB requires
replacement. If the unit responds, the display board
requires replacement.
background
mrcool.com 40
40
POST-INSTALLATION
7
LEDFlashFrequency:
Display Error Information
DF
Defrost
FC
Forced cooling
EC 51
ODU EEPROM Parameter Error
EL 01
IDU & ODU Communication Error
PC 40
Communication Error between Outdoor Main Chip & Compressor-Driven Chip
PC 08
ODU Overcurrent Protection
PC 10
ODU Low AC Voltage Protection
PC 11
ODU Main Control Board DC Bus High Voltage Protection
PC 12
ODU Main Control Board DC Bus Low Voltage Protection/341 MCE Error
PC 00
ODU IPM Module Protection
PC 0F
PFC Module Protection
EC 71
Over Current Failure of ODU DC Fan Motor
EC 72
Lack Phase Failure of ODU DC Fan Motor
EC 07
ODU Fan Speed Out of Control
PC 43
ODU Compressor Lack Phase Protection
PC 44
ODU Zero Speed Protection
PC 45
ODU IR Chip Drive Failure
PC 46
Compressor Speed Out of Control
PC 49
Compressor Overcurrent Failure
PC 30
System High Pressure Protection
PC 31
System Low Pressure Protection
PC 0a
High Temperature Protection of Condenser
PC 06
Discharge Temperature Protection of Compressor
LC 06
High Temperature Protection of Inverter Module (IPM)
PC 02
Compressor Top (or IPM) Temperature Protection
PH 90
High Temperature Protection of Evaporator
PH 91
Low Temperature Protection of Evaporator
EC 52
ODU Coil Temperature Sensor (T3) Error
EC 53
ODU Ambient Temperature Sensor (T4) Error
EC 54
Comp. Discharge Temperature Sensor (TP) Error
EC 50
Open or Short Circuit of Outdoor Unit Temperature Sensor (T3, T4, TP)
PC 0l
Low Ambient Temperature Protection
7.6 Error Display (Outdoor Unit with Auxiliary Board)
background
mrcool.com41
POST-INSTALLATION
7
7.7 Quick Maintenance by Error Code
If you do not have the time to test which specic parts are faulty, you can change the required parts according to
the error code. You can nd the parts to replace by error code in the following table.
PartRequiring
Replacement
Error Code
EH 00/
EH 0A
EL 01 EH 02 Eh 03 EH 60 EH 61 EH 0B EL 0c ec 56 fh cc
Indoor PCB
√ √ √ √ √ √ √ √
X X
Outdoor PCB
X
√
X X X X X X
√
X
Display Board
X X X X X X
√
X X X
Indoor Fan Motor
X X X
√
X X X X X X
T1 Sensor
X X X X
√
X X X X X
T2 Sensor
X X X X X
√
X
√
X X
T2B Sensor
X X X X X X X X
√
X
Refrigerant Sensor
X X X X X X X X X
√
Reactor
X
√
X X X X X X X X
Compressor
X X X X X X X X X
√
Additional Refrigerant
X X X X X X X
√
X X
PartRequiring
Replacement
Error Code
EC 53 EC 52 EC 54 EC 51 EC 07 PC 00 PC 01 PC 02 PC 03 PC 04
Outdoor PCB
√ √ √ √ √ √ √ √ √ √
Indoor Fan Motor
X X X X X X X X X X
Outdoor Fan Motor
X X X X
√ √
X
√
X
√
T3 Sensor
X
√
X X X X X X X X
T4 Sensor
√
X X X X X X X X X
TP Sensor
X X
√
X X X X X X X
Reactor
X X X X X X
√
X X X
Compressor
X X X X X
√
X X X
√
IPM Module Board
X X X X X
√ √ √
X
√
High Pressure Protector
X X X X X X X
√
X X
Low Pressure Protector
X X X X X X X X
√
X
Additional Refrigerant
X X X X X X X X
√
X
background
mrcool.com 42
42
POST-INSTALLATION
7
PartRequiringReplacement
Error Code
PC 06 PC 08/44/49 PC 0a PC of PC 40
Outdoor PCB
√ √ √ √ √
Outdoor Fan Motor
X
√ √
X X
T3 Sensor
X X
√
X X
TP Sensor
√
X X X X
Pressure Sensor
X X X X X
Reactor
X
√
X
√
X
Compressor
X X X X X
IPM Module Board
X
√
X X
√
High Pressure Valve Assembly
√
X X X X
High Pressure Protector
X X X X X
Low Pressure Protector
X X X X X
Additional Refrigerant
√
X
√
X X
Electric Control Box
X X X X
√
PartRequiringReplacement
Error Code
PC 41 PC 43 PC 10/11/12 PC 30 PC 31
Outdoor PCB
√ √ √ √ √
Outdoor Fan Motor
X X X
√
X
T3 Sensor
X X X X X
TP Sensor
X X X X X
Pressure Sensor
X X X X X
Reactor
X X
√
X X
Compressor
X
√
X X X
IPM Module Board
X X
√
X X
High Pressure Valve Assembly
X X X X X
High Pressure Protector
X X X
√
X
Low Pressure Protector
X X X X
√
Additional Refrigerant
X X X X
√
background
DIY
®
Hyper Heat Series
Single-Zone
Mini-Split System
The design and specications of this product and/or manual are subject to change without prior notice.
Consult with the sales agency or manufacturer for details.

Specifications

Mrcool DIYHH-18-HP-C-230D25-O Questions and Answers

Questions and Answers

Related Products