Goodman GRVT800805CX GRVT80 Gas Furnace 80% AFUE Variable-Speed Two-Stage Upflow/Horizontal

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Installation Instruction Other Documents
GRVT800805CX photo

Manual

This is the main product document for model GRVT800805CX.

The file format is pdf, 56 pages, you can download this manual here .

background
Service and Troubleshooting
Goodman® Brand GRVT80/GDVT80 & Amana® Brand ARVT80/ADVT80
80% Two Stage Gas Furnaces with Variable-Speed ECM Motor
RS6621305r1
October 2025
TABLE OF CONTENTS
IMPORTANT INFORMATION ............................................. 2
PRODUCT IDENTIFICATION ............................................ 4
SYSTEM OPERATION ....................................................... 6
SCHEDULED MAINTENANCE ........................................ 22
SERVICING ...................................................................... 25
CHECKING VOLTAGE ............................................... 26
CHECKING WIRING ................................................... 26
CHECKING THERMOSTAT, WIRING ........................ 26
CHECKING TRANSFORMER AND CONTROL
CIRCUIT ....................................................................... 26
CHECKING AIR CIRCULATION BLOWER MOTOR 27
CHECKING DUCT STATIC ......................................... 30
CHECKING TEMPERATURE RISE ........................... 31
CHECKING PRIMARY LIMIT CONTROL .................. 31
CHECKING AUXILIARY LIMIT CONTROL ................ 32
CHECKING FLAME ROLLOUT CONTROL .............. 33
INDUCED DRAFT BLOWER MOTOR ....................... 33
CHECKING GAS VALVE (REDUNDANT) ................. 33
CHECKING MAIN BURNERS .................................... 34
CHECKING ORIFICES ............................................... 34
CHECKING GAS PRESSURE ................................... 35
CHECKING HOT SURFACE IGNITOR ...................... 36
CHECKING FOR FLASHBACK .................................. 36
CHECKING PRESSURE SWITCH............................. 36
HIGH ALTITUDE APPLICATION ................................ 37
CHECKING FOR DELAYED IGNITION ..................... 37
CHECKING INTEGRATED IGNITION
CONTROL BOARDS ................................................... 37
CHECKING FLAME SENSOR .................................... 38
TROUBLESHOOTING CHART ........................................ 42
WIRING DIAGRAM .......................................................... 56
Pride and workmanship go into every product to provide
our customers with quality products. It is possible, however,
that during its lifetime a product may require service.
Products should be serviced only by a qualied service
technician who is familiar with the safety procedures
required in the repair and who is equipped with the proper
tools, parts, testing instruments and the appropriate service
manual. REVIEW ALL SERVICE INFORMATION IN THE
APPROPRIATE SERVICE MANUAL BEFORE
BEGINNING REPAIRS.
ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL,
ADJUST, SERVICE, MAINTENANCE OR REPAIR
(HEREINAFTER, “SERVICE”) THE EQUIPMENT SPECIFIED IN
THIS MANUAL SHOULD SERVICE THE EQUIPMENT.
THIS EQUIPMENT IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK
OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE
BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING
USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR
THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT
THEY DO NOT PLAY WITH THE EQUIPMENT.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR
ANY INJURY OR PROPERTY DAMAGE ARISING FROM
IMPROPER SUPERVISION, SERVICE OR SERVICE
PROCEDURES. IF YOU SERVICE THIS UNIT, YOU ASSUME
RESPONSIBILITY FOR ANY INJURY OR PROPERTY
DAMAGE WHICH MAY RESULT. IN ADDITION, IN
JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES
TO SERVICE THE EQUIPMENT SPECIFIED IN THIS
MANUAL, ONLY LICENSED PERSONNEL SHOULD SERVICE
THE EQUIPMENT. IMPROPER SUPERVISION, INSTALLATION,
ADJUSTMENT, SERVICING, MAINTENANCE OR REPAIR OF
THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR
ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR
THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT
PROPER SUPERVISION OR TRAINING MAY RESULT IN
PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.
WARNING
WARNING
DO NOT BYPASS SAFETY DEVICES
Copyright © 2025 Daikin Comfort Technologies Manufacturing, Inc.
19001 Kermier Rd. Waller, TX 77484
®
is a registered trademark of Maytag Corporation or its related companies and is used under license.
All rights reserved.
background
IMPORTANT INFORMATION
2
IMPORTANT NOTICES
RECOGNIZE SAFETY SYMBOLS, WORDS AND
LABELS
OUTSIDE THE U.S., call 1-713-861-2500.
(Not a technical assistance line for dealers.) Your telephone company will bill you for the call.
WARNING
This furnace may be paired with a cooling unit
that uses R-32 refrigerant. If the refrigeration
unit paired with this furnace does not use
R-32, The R-32 function in the furnace control
board needs to be turned off. Please see the
electrical and the R-32 sections for more
details.
Refrigerant systems other than R-410A or R-32
may require an additional mitigation control
board. refer to the installation manual of
the indoor evaporator coil to determine
installation requirements for that supplier’s
refrigerant detection system.
WARNING
This unit should not be connected to, or used
in conjuction with, any devices that are not
certified for use with this unit or have not
been tested and approved by the manufacturer.
Serious property damage or personal injury,
reduced unit performance, and/or hazardous
conditions may result from the use of devices
that have not been approved or certified by the
manufacturer.
WARNING
To prevent the risk of property damage,
personal injury, or death, do not store
combustible materials or use gasoline or other
flammable liquids or vapors in the vacinity of
this appliance.
WARNING
High voltage
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
CARBON MONOXIDE POISONING HAZARD
Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas
Carbon monoxide producing devices (such as automobiles, space
heater, gas water heater, etc.) should not be operated in enclosed
areas such as unventilated garages, utility rooms or parking areas
because of the danger of carbon monoxide (CO) poisoning resulting
from the exhaust emissions. If a furnace or air handler is installed in
an enclosed area such as a garage, utility room or parking area and a
carbon monoxide producing device is operated therein, there must be
adequate, direct outside ventilation.
This ventilation is necessary to avoid the danger of CO poisoning
which can occur if a carbon monoxide producing device continues
to operate in the enclosed area. Carbon monoxide emissions can be
(re)circulated throughout the structure if the furnace or air handler is
operating in any mode.
CO can cause serious illness including permanent brain damage or
death.
B10259-216
RIESGO DE INTOXICACIÓN POR MONÓXIDO DE CARBONO
Advertencia especial para la instalación de calentadores ó manejadoras
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
Los equipos ó aparatos que producen monóxido de carbono (tal
como automóvil, calentador de gas, calentador de agua por medio de
gas, etc) no deben ser operados en áreas cerradas debido al riesgo
de envenenamiento por monóxido de carbono (CO) que resulta de las
emisiones de gases de combustión. Si el equipo ó aparato se opera
en dichas áreas, debe existir una adecuada ventilación directa al
exterior.
Esta ventilación es necesaria para evitar el peligro de envenenamiento
por CO, que puede ocurrir si un dispositivo que produce monóxido de
carbono sique operando en el lugar cerrado.
Las emisiones de monóxido de carbono pueden circular a través del
aparato cuando se opera en cualquier modo.
El monóxido de carbono puede causar enfermedades severas como
daño cerebral permanente ó muerte.
B10259-216
RISQUE D’EMPOISONNEMENT AU MONOXYDE DE CARBONE
Avertissement special au sujet de l’installation d’appareils de chau󰀨age
ou de traitement d’air dans des endroits clos, tets les garages, les
locaux d’entretien et les stationnementss.
Evitez de mettre en marche les appareils produisant du monoxyde
de carbone (tels que les automobile, les appareils de chau󰀨age
autonome, etc.) dans des endroits non ventilés tels que les
d’empoisonnement au monoxyde de carbone. Si vous devez faire
fonctionner ces appareils dans un endroit clos, assures-vous qu’il y
ait une ventilation directe provenant de l’exterier.
Cette ventilation est nécessaire pour éviter le danger d’intoxication
au CO pouvant survenir si un appareil produisant du monoxyde de
carbone continue de fonctionner au sein de la zone connée.
Les émissions de monoxyde de carbone peuvent etre recircules dans
les endroits clos, si l’appareil de chau󰀨age ou de traitement d’air sont
en marche.
Le monoxyde de carbone peut causer des maladies graves telles que
des dommages permanents au cerveau et meme la mort.
B10259-216
background
IMPORTANT INFORMATION
3
A. This appliance does not have a pilot. It is equipped
with an ignition device which automatically lights the
burners. Do not try to light the burners by hand.
WHAT TO DO IF YOU SMELL GAS
-Do not try to light any appliance.
-Do not touch any electric switch;
do not use any telephone in your building.
-Immediately call your gas supplier from a neighbor's
phone. Follow the gas suppliers instructions.
1. STOP! Read the safety information
above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the appliance.
4. This appliance is equipped with an
automatic ignition system which automatically
lights the burners. Do n
ot try to light the burners
by hand.
5. Remove control access panel.
6. Move the gas control switch or knob to "OFF".
B. BEFORE OPERATING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas
is heavier than air and will settle on the floor.
FOR YOUR SAFETY READ BEFORE OPERATING
FOR YOUR SAFETY:
1. Set the thermostat to its lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Remove control access panel.
4. Move the gas control switch or knob to "OFF". Do not force.
5. Replace control access panel.
TO TURN OFF GAS TO APPLIANCE
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
0140F02503
-A
7. Wait five (5) minutes to clear out any
gas. Then smell for gas, including near the
floor. If you smell gas, STOP!
Follow "B" in the safety information
above on this label. If you don't smell
gas, go to the next step.
8. Move the gas control switch or knob
to "ON".
9. Replace control access panel.
10. Turn on all electric power to the appliance.
11. Set the thermostat to the desired setting.
12. If the appliance will not operate,
follow the instructions "To Turn Off Gas To
Appliance" and call your service technician
or gas supplier.
OPERATING INSTRUCTIONS
This furnace must be installed in accordance with the
manufacturers instructions and local codes. In the
absence of local codes, follow the National Fuel Gas
Code, ANSI Z223.1.
WARNING
: If not installed, operated and
maintained in accordance with the manufacturer’s
instructions, this product could expose you to
substances during fuel combustion which can
cause death or serious illness. This product
contains fiberglass insulation.
No almacene ni use gasolina u otros vapores y
líquidos inflamables cerca de este o cualquier otro
aparato.
PARA SU SEGURIDAD:
ADVERTENCIA
: Si no se instala, se activa y se
mantiene conforme a las instrucciones del
fabricante, este producto podría exponerlo a
sustancias durante la combustión del carburante,
lo que puede causar la muerte o enfermedades
severas. Este producto contiene aislante de fibra
de vidrio.
If you cannot reach your gas supplier, call the
fire department.
ADVERTENCIA
: En caso de no seguir estas instrucciones
cuidadosamente, se podría producir un incendio o
explosión que ocasionaría daños a la propiedad, lesiones
personales e incluso la muerte.
WARNING
: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
WARNING
: Improper installation, adjustment,
alteration, service or maintenance can cause injury
or property damage. Refer to the user’s information
manual provided with this furnace. For assistance
or additional information consult a qualified
installer, service agency or the gas supplier.
ADVERTENCIA
: La instalación, el ajuste, la
alteración, el servicio o el mantenimiento
inadecuados pueden causar lesiones o daños a
la propiedad. consulte el manual de información
del usuario que acompaña a este horno. Para
obtener ayuda o información adicional, consulte
con un instalador calificado, una agencia de
servicio o el proveedor de gas.
D. Do not use this appliance if any part
has been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which has
been under water.
C. Use only your hand to move the gas
control switch or knob. Never use tools. If
the gas control switch or knob will not
operate, don't try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
GAS CONTROL
SWITCH SHOWN
IN "ON" POSITION
GAS CONTROL
SWITCH SHOWN
IN "ON" POSITION
background
PRODUCT IDENTIFICATION
4
NOMENCLATURE
The model and manufacturing number are used for positive identication of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.
A R V T 8 0 0 6 0 3 B N A A
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Brand Minor Revision
A - Amana® A - Initial Release
G - Goodman® B - 1st Revision
Configuration
R - Upflow/Horizontal Major Revision
D - Downflow/Horizontal A - Initial Release
B - 1st Revision
Nox
Motor
V - Variable Speed
Cabinet Width
A - 14"
Gas Valve B - 17.5"
T - 2 Stage C - 21"
M - Modulating D - 24.5"
Maximum CFM
3 - 1200 CFM
AFUE 4 - 1600 CFM
80 - 80% AFUE 92 - 92% AFUE 5 - 2000 CFM
96 - 96% AFUE 97 - 97% AFUE
MBTU/h
030 - 30,000 BTU/h 080 - 80,000 BTU/h
040 - 40,000 BTU/h 100 - 100,000 BTU/h
060 - 60,000 BTU/h 120 - 120,000 BTU/h
Furnace Nomenclature (14 Digits)
N = > 40 NG/J NOx
X = < 40 NG/J NOx
U = < 14NG/J NOx
background
PRODUCT IDENTIFICATION
5
MFG. # MODELS DESCRIPTION
ARVT80*N
ARVT800603BN AA
ARVT800604BN AA
ARVT800803BN AA
ARVT800804CN AA
ARVT800805CN AA
ARVT800805DN AA
ARVT801005CN AA
Amana® Brand 80% Bluetooth® Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Up flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Stainless Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry.
ARVT80*X
ARVT800603BX AA
ARVT800604BX AA
ARVT800803BX AA
ARVT800804CX AA
ARVT800805CX AA
ARVT800805DX AA
ARVT801005CX AA
Amana® Brand 80% Bluetooth Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Up flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Stainless Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry. NOx emmissions < 40
ng/joule
GRVT80*N
GRVT800603BN AA
GRVT800604BN AA
GRVT800803BN AA
GRVT800804CN AA
GRVT800805CN AA
GRVT800805DN AA
GRVT801005CN AA
Goodman® Brand 80% Bluetooth Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Up flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Aluminized Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry.
GRVT80*X
GRVT800603BX AA
GRVT800604BX AA
GRVT800803BX AA
GRVT800804CX AA
GRVT800805CX AA
GRVT800805DX AA
GRVT801005CX AA
Goodman® Brand 80% Bluetooth Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Up flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Aluminized Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry. NOx emmissions < 40
ng/joule
ADVT80*X
ADVT800603BX AA
ADVT800803BX AA
ADVT800805CX AA
ADVT801005CX AA
Amana® Brand 80% Bluetooth Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Down flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Stainless Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry. NOx emmissions < 40
ng/joule
GDVT80*X
GDVT800603BX AA
GDVT800803BX AA
GDVT800805CX AA
GDVT801005CX AA
Goodman® Brand 80% Bluetooth Capable Gas Furnace, 2 stage gas valve. Provides 2
stages of heating & cooling with single stage thermostat. Down flow/Horizontal Left and
Right, Induced Draft, Nidec multi-speed ECM motor. Aluminized Steel tubular heat
exchanger. 115 volt silicon nitride igniter. Left or right gas entry. NOx emmissions < 40
ng/joule
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc., and
any use of such marks are under license.
background
SYSTEM OPERATION
6
ELECTRICAL CONNECTIONS
WARNING
High Voltage!
To avoid the risk of electrical shock,
wiring to the unit must be polarized and
grounded.
WARNING
High Voltage!
To avoid personal injury or death
due to electrical shock, disconnect
electrical power before servicing or
changing any electrical wiring.
CAUTION
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
Wiring Harness
The wiring harness is an integral part of this furnace.
Wires are color coded for identication purposes. Refer to
the wiring diagram for wire routings. If any of the original
wire as supplied with the furnace must be replaced, it must
be replaced with wiring material having a temperature
rating of at least 105° C. Any replacement wiring must be a
copper conductor.
115 Volt Line Connections
Before proceeding with electrical connections, ensure that
the supply voltage, frequency, and phase correspond to
that specied on the unit rating plate. Power supply to
the furnace must be NEC Class 1, and must comply with
all applicable codes. The furnace must be electrically
grounded in accordance with local codes or, in their
absence, with the latest edition of The National Electric
Code, ANSI NFPA 70 and/or The Canadian Electric Code
CSA C22.1.
Use a separate branch electrical circuit containing properly
sized wire, and fuse or circuit breaker. The fuse or circuit
breaker must be sized in accordance with the maximum
overcurrent protection specied on the unit rating plate.
An electrical disconnect must be provided at the furnace
location.
Connect hot, neutral, and ground wires as shown in the
wiring diagram located on the unit’s blower door. For
direct vent applications, the cabinet opening to the junction
box must be sealed air tight using either a UL approved
bushing such as Heyco Liquid Tight or by applying non-
reactive UL approved sealant to bushing.
Line polarity must be observed when making eld
connections. Line voltage connections can be made
through either the right or left side panel. The furnace is
shipped congured for a left side (right side for counter
ows) electrical connection with the junction box located
inside the burner compartment. To make electrical
connections through the opposite side of the furnace, the
junction box must be relocated to the other side of the
burner compartment prior to making electrical connections.
To relocate the junction box, follow the steps shown below.
NOTE: Wire routing must not to interfere with
circulator blower operation, filter removal, or
routine maintenance.
Junction Box Relocation
WARNING
Edges of sheet metal holes may be sharp. Use
gloves as a precaution when removing hole
plugs.
WARNING
To prevent personal injury or death due to
electric shock, disconnect electrical power
before installing or servicing this unit.
Line voltage connections can be made through either the
right or left side panel. The furnace is shipped congured
for a left side electrical connection. To make electrical
connections through the opposite side of the furnace, the
junction box must be relocated to the right side prior to
making electrical connections. To relocate the junction box,
perform the following steps.
1. Remove the burner compartment door.
2. Remove and save the two screws securing the junction
box to the side panel.
3. Relocate junction box and associated plugs and
grommets to opposite side panel. Secure with screws
removed in step 2.
To ensure proper unit grounding, the ground wire should
run from the furnace ground screw located inside the
furnace junction box all the way back to the electrical panel.
background
SYSTEM OPERATION
7
NOTE: Do not use gas piping as an electrical
ground. To confirm proper unit grounding,
turn off the electrical power and perform the
following check.
1. Measure resistance between the neutral (white)
connection and one of the burners.
2. Resistance should measure 10 ohms or less.
This furnace is equipped with a blower door interlock
switch which interrupts unit voltage when the blower door is
opened for servicing. Do not defeat this switch.
EXTREMELY IMPORTANT: This system does not
contain an O wire input (reversing valve signal).
If a heat pump is installed, the thermostat should
be setup for single stage heat/single stage
cool installs ( W= Heat Call and Y = Cool Call).
Setting thermostat for heat pump control will
result in incorrect performance.
Quick Start Guide
1. Connect all necessary thermostat wires to the thermostat
connector on the furnace control (only available
connections on the furnace are R & C for power, Y for
Cooling Calls, W for Heating Calls, G for Fan Calls,
Dehum for Dehumidication Calls. Furnace will control
staging of indoor unit and outdoor unit automatically
based on these inputs).
2. Make sure thermostat is set to single stage heat / single
stage cool mode. When a cool call is given, 24VAC
should be applied to the Y terminal (G will have 24VAC
as well if a G wire is installed). When a heat call is given
24VAC should be applied to the W terminal (G may
have 24VAC as well if a G wire is installed). Even if a
heat pump is installed, do not setup the thermostat in
heat pump mode. Single stage heat / single stage cool
mode is all that is required for all applications. See rest
of manual for any exceptions. Do not setup thermostat
in multi stage mode either, it is not necessary.
3. For communicating 2 stage AC/HP or inverter AC/
HP outdoor units, connect the 1&2 wires between the
indoor and outdoor unit. It is recommended for 2 stage
applications that a separate transformer be installed in
the outdoor unit to provide 24VAC to the outdoor control.
R&C can be used between the indoor and outdoor in
2 stage AC application but only if there isn’t already a
transformer installed in the outdoor unit.
4. Turn on power to Indoor and Outdoor units
5. Charging outdoor unit: Provide a cooling call (Y or
Y+G) – this initial cooling call after the power is turned
on will run the outdoor unit at full capacity until the call
is removed. Use this mode for charging. If system is
running low stage cooling just cycle power and provide
a cool call again to ensure full capacity cooling.
6. System Testing: Download the CoolCloudHVAC phone
application (see pages 31 and 32)and use it to test all
operations of both indoor and outdoor units.
7. Conrm thermostat heat (W or W+G) and cool (Y or
Y+G) function properly and the system is turning on in
the correct mode. The internal algorithms will constantly
be adjusting the staging times / cooling capacities based
on load changes to the space.
NOTE: If a heat pump is installed it will be treated
as a priority heat for a W call. To test gas heat
only, without waiting for the system to stage
between the heat pump and furnace, disconnect
communications between the indoor and outdoor
unit before running the heating test.
Control System – General Information
The furnace contains internal logic to control equipment
staging. An adjustable target runtime is available (range
from 1 to 240 minutes) and set through the appropriate
system menu. The system will constantly be adjusting
staging in an e󰀨ort to satify the thermostat call for cooling
(Y only) or heating (W Only) as close to the set target
runtime as possible. See information below for setting
options.
Comfort Setting Menu (CFS)
There are 6 options available in the Comfort Setting
Menu which impacts both the System Target Runtime and
Dual Fuel Operation. Dual Fuel operation adjustments
only apply if a communicating heat pump is installed.
Comfort Setting Options 1 – 5 have set values for the
System Target Runtime and option 6 enables additional
menus to customize all comfort settings. See list below
for the System Target Run times associated with the rst
5 Comfort Settings. These rst 5 options are setup to
help satisfy the thermostat slower or faster based on the
selection where option 1, with a 10 minute Target Runtime,
is attempting to satisfy much faster than option 5, with a 30
minute Target Runtime.
System Target Runtime
Comfort Setting Option 1) 10 Minute System Target
Runtime
Comfort Setting Option 2) 15 Minute System Target
Runtime
Comfort Setting Option 3) 20 Minute System Target
Runtime
Comfort Setting Option 4) 25 Minute System Target
Runtime
Comfort Setting Option 5) 30 Minute System Target
Runtime
background
SYSTEM OPERATION
8
Dual Fuel Adjustment
This system will automatically determine if the heat pump is
capable of satisfying the thermostat in the selected System
Target Runtime. If the heat pump is unable to satisfy in
the selected time, dual fuel settings will determine how
many attempts should be given to the heat pump before
temporarily locking it out and using the furnace. These
dual fuel settings also determine at what time the system
should remove the temporary heat pump lockout and run
the heat pump again.
There are four adjustable items associated with Dual Fuel
control. In the same way as the System Target Time, each
of these items have defaulted values for Comfort Settings 1
– 5. Only when Comfort Setting 6 is selected will each item
be available for full adjustment.
1. Stage Up Percent (7 segment menu SUP): This is a
value that determines how far past the target runtime the
system should continue running the heat pump before
transitioning to the furnace. For example, assume this
menu was set to 20% with a target runtime of 20 minutes.
If the thermostat did not remove the heating call after
20 minutes, the system would allow for an additional
20% heat pump run (20% of the 20 minute target is an
additional 4 minutes). In this case, the system would
transition to gas heat after 24 minutes if the thermostat
call was still present. Each time this occurs, the system
records this as a strike against the heat pump (the strike
is important when looking at the Over Target Threshold)
2. Over Target Threshold (7 segment menu Ott): If the
heat pump has consecutively transitioned to gas heat
for the selected Over Target Threshold amount of times,
meaning for this many consecutive cycles it has been
unable to satisfy the target time by itself, then the heat
pump will be temporarily locked out and the furnace will
become the primary heat source.
3. Stage Down Percent (7 segment menu SdP): This only
applies when the heat pump is in a temporary lockout
condition. In this case, the system will be trying to
determine when the best time is to remove the lockout
and run the heat pump again. To determine the best time
to remove the heat pump lockout the system looks at
how easily the furnace is able to satisfy the thermostat
using Low Stage Gas Heat Only. Assume this setting is
15% and the target time is 20 minutes. If Low Stage Gas
Heat can satisfy the thermostat in less than 17 minutes
(20 minutes - 15% = 17 minutes) then the algorithm
records a strike against the gas furnace. (this strike is
important when looking at the Under Target Threshold).
4. Under Target Threshold (7 segment menu Utt): If the
furnace is able to satisfy the thermostat using Low Stage
Gas Heat Only for the selected number of consecutive
cycles the heat pump lockout will be temporarily
removed. The heat pump will then be used during the
next cycle. If the heat pump can satisfy the thermostat
in less than the System Target Runtime the temporary
heat pump hold will be completely removed and the
heat pump will become the primary heat source again.
if it fails to do so, the strike count against the furnace
will be reset and the furnace will remain the temporary
primary heat source until the Under Target Threshold is
reached again.
The system will automatically make adjustments in an
attempt to satisfy the thermostat as close to this target
runtime as possible. After a power cycle or mode change
(cooling to heating or heating to cooling) the system will
run full capacity for the selected mode during the rst
thermostat call. Based on the selected target runtime and
how long the initial cycle takes to satisfy the thermostat,
the control algorithm will adjust the system stage times for
a 2 stage unit or the capacity demand percentage for an
inverter / modulating unit for the next cycle. Note: actual
run times may change depending on variations of load
throughout the day.
The following table shows the default values for all Comfort
Setting Options (1 – 5)
Comfort
Setti ng
Opti on
Stage Up
Percentage
(%)
Stage Down
Percentage
(%)
Over Target
Threshhold
(Strike Count)
Under Target
Threshhold
(Strike Count)
1 10 20 20 2 10
2 15 20 20 4 8
3 20 20 20 6 6
4 25 20 20 8 4
5 30 20 20 10 2
The following table shows the ranges for each of item
when the adjustable Comfort Setting Option 6 is selected.
The table shows the minimum value, the maximum value
and the defaulted value. All items can be adjusted up or
down by increments of 1 which provides full exibility
for all items. Note: it is critical that these numbers be
set properly. If Comfort Setting option 3 is desired but
a target time of 60 is preferred, select Comfort Setting
Option 6 to enable all the adjustable menus, set the
Target Time to 60 and make sure the other menus are
set to match that of Comfort Setting Option 3.
Menu
Minimum
Value
Maximum
Value
Default
Value
Target Time (t9t) 1 minute 240 minutes 60 minutes
Stage Up Percent (SUP) 0% 100% 20%
Stage down Percent (SdP) 0% 100% 20%
Over Target Threshold (Ott) 1 strike 254 strikes 20 strikes
Under Target Threshold (Utt) 1 strike 254 strikes 20 strikes
background
SYSTEM OPERATION
9
Circulator Blower Speed
The Airow quantity is displayed as a number on the three
7 segment displays, rounded to the nearest 100 CFM. The
display alternates airow amount and the system operating
status.
Each furnace has a “Maximum CFM” it is capable of
providing. All fan operations (Constant CFM, Cooling
Airow Proles, Low and High Stage gas heat airow,
outdoor Air Conditioner / Heat Pump Airow, etc.) are
based o󰀨 of multipliers which are percentages of this
maximum CFM. Max CFM is as follows:
3 Ton Models 1400 CFM
4 Ton Models 1760 CFM (1650 CFM for 0803 Models)
5 Ton Models 2200 CFM
Setup Furnace Airow: adjust the Gas Heating Airow
menu (gAF) setting to the desired percentage of maximum
airow. In most cases the default gas heat airow
will provide a temperature rise near the middle of the
acceptable range. High Stage CFM can be calculated
by the following equation: CFM = Max CFM * Selected
Heating Airow Percentage.
For Communicating Outdoor Units: Main airow adjustment
is not required. The Outdoor unit will determine the
appropriate amount of indoor airow to request. Airow
Trims can be made if desired.
For Non-Communicating outdoor units, determine the
proper airow (based o󰀨 tonnage of) the outdoor unit. Most
cooling systems are designed to work with airow between
350 and 450 CFM per ton. 400 CFM/TON is the industry
standard. Once desired airow has been determined, see
Tonnage / Airow table to identify the Tonnage Selection
that is closest to the desired airow. This table is based
on 400 CFM per ton where Airow = (400 CFM) x (Selected
Tonnage).
Example: if 1520 CFM is the desired airflow the
Tonnage Selection that matches this is 3.8
Enter the Tonnage (ton) menu either by using the on board
push buttons or phone application and select the Tonnage
Selection you identied.
Note: Trim is also available if additional
adjustment is required.
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
Tonnage
Selection
Airflow
1 400
2.3
920
3.6 1440
4.9
1960
1.1 440 2.4 960 3.7 1480 5 2000
1.2 480 2.5 1000 3.8 1520 5.1 2040
1.3 520 2.6 1040 3.9 1560 5.2 2080
1.4 560 2.7 1080 4 1600 5.3 2120
1.5 600 2.8 1120 4.1 1640 5.4 2160
1.6 640 2.9
1160
4.2 1680 5.5
2200
1.7 680 3 1200 4.3 1720 5.6 2240
1.8 720 3.1 1240 4.4 1760 5.7 2280
1.9 760 3.2 1280 4.5 1800 5.8 2320
2 800 3.3 1320 4.6 1840 5.9 2360
2.1 840 3.4 1360 4.7 1880 6 2400
2.2 880 3.5 1400 4.8 1920
Cooling Airflow Ramping Profiles
The multi-circulator blower also o󰀨ers several custom
ON/ OFF ramping proles. These proles may be used to
enhance cooling performance and increase comfort level.
The ramping proles are selected using the Cooling Airow
Prole menu (if push buttons are used, use the CAP menu
to select the desired prole). Refer to the bullet points
below for a description of each ramping prole.
OFF
100% CFM 100% CFM
1 min
OFF
Figure 50
• provides only an OFF delay of one (1) minute at 100% of the cooling demand Profile A(1)
50% CFM
1/2 min
100% CFM
100% CFM
1 min
OFF
OFF
Figure 51
• ramps up to full cooling demand airflow by first stepping up to 50% of the full
demand for 30 seconds. The motor then ramps to 100% of the required airflow. A one (1)
minute OFF delay at 100% of the cooling airflow is provided.
Profile B(2)
100% CFM
OFF
OFF
• ramps up to 85% of the full cooling demand airflow and operates there for
approximately 7 1/2 minutes. The motor then steps up to the full demand airflow. Profile C
also has a one (1) minute 100% OFF delay.
Profile C(3)
Figure 52
OFF
OFF
• ramps up to 50% of the demand for 1/2 minute, then ramps to 85% of the full
cooling demand airflow and operates there for approximately 7 1/2 minutes. The motor
then steps up to the full demand airflow. Profile D has a 1/2 minute at 50% airflow OFF delay.
Profile D(4 or 5)
Figure 53
In general lower heating speeds will: reduce electrical
consumption, lower operating sound levels of the blower,
and increase the outlet air temperature delivered to the
home if heat mode is running. If cooling mode is running
the same airow adjustment will decrease the outlet air
temperature delivered to the home. The speeds available
allow the blower performance to be optimized for the
particular homeowner’s needs.
background
SYSTEM OPERATION
10
Low Voltage Wiring - General Information
The Furnace functions with any thermostat that can be
congured to provide 24VAC on Y for cooling calls and
24VAC on W for Heating calls. Based on these simple
inputs, internal algorithms will decide how to control two
stages of furnace heat in addition to any single or multi
stage outdoor heating / cooling operation (the algorithms
will handle dual fuel multi-stage systems as well). The
thermostat must be setup to provide only a Y call when
cooling is required and only a W call when heating is
required. This is generally accomplished by selecting single
stage heat / single stage cool mode during setup (if setup
is required). Do not set thermostat to heat pump operation
as system will not operate properly.
Note: The only exception is if a single stage non-
communicating Heat Pump is connected to the
furnace. Refer to Non-Communicating Single
Stage Heat Pump diagram for details.
Thermostat connections to the control board are R, C, G,
W, Y & Dehum. Provided the thermostat does not require a
common wire as few as two thermostat wires may be used
for heat only (R and W) or cool only (R and Y) systems. A
minimum three thermostat wires may be used for heating
and cooling systems (R, W and Y). Refer to thermostat
wiring diagrams below for your system conguration.
Low voltage connections can be made through either the
right or left side panel of the furnace. Thermostat wiring
entrance holes are located in the blower compartment.
CONDENSATE SWITCH
COMMUNICATING
OUTDOOR UNIT
THERMOSTAT
Main Control Board
For gas heat only operations (no outdoor unit installed)
the thermostat must be setup to provide a single stage W
call when heating is required. See Gas Heat Only wiring
diagram for wiring instructions.
R
C
G
Y
Optional
Optional
INDOOR
BOARD TERMINAL
CONNECTIONS
R
C
G
Y
24 VAC
Thermostat
1
2
C
Gas Heat Only
Low Voltage Wiring - Communicating Outdoor
Unit
Internal logic will control staging of all multi stage
equipment (2 stage AC/HP units and Inverter AC/HP units).
The thermostat is only required to provide a single stage
heat / cool call and fan or dehumidication call during
operation.
Two wires are required between the indoor unit and
outdoor unit on the 1 and 2 terminals. It is recommended to
install a separate transformer with all 2 stage outdoor units
to reduce the power draw on the indoor transformer.
4 wires (R,C for power and 1, 2 for communications) can
be used for AC applications. See wiring images for details.
Do not connect R & C between the indoor unit and the
outdoor unit if there is already a transformer installed in the
outdoor unit providing 24VAC to the outdoor control. In this
case, just use 1 and 2 terminals for communications.
R
C
G
Y
Optional
Optional
Optional if
feature
supported by
thermostat
INDOOR
BOARD TERMINAL
CONNECTIONS
OUTDOOR
BOARD TERMINAL
CONNECTIONS
OUTDOOR
TRANSFORMER
1
2
C
R
C
G
Y
1
2
C
Communicating Two Stage
Air Conditioner or Heat Pump
background
SYSTEM OPERATION
11
1
2
C
R
C
G
Y
Optional
Optional
Optional if
feature
supported by
thermostat
INDOOR
BOARD TERMINAL
CONNECTIONS
OUTDOOR
BOARD TERMINAL
CONNECTIONS
1
2
C
R
C
G
Y
24 VAC
Thermostat
Communicating Inverter
Air Conditioner or Heat Pump
Low Voltage Wiring - Non-Communicating Outdoor
Unit
When using the furnace with a single stage non-
communicating air conditioner or heat pump use the wiring
methods shown. When using a single stage air conditioner,
the thermostat must be setup for single stage heating and
single stage cooling mode. When using a single stage
heat pump, the thermostat must be setup for dual fuel
operation where the reversing valve is energized in cooling
mode (see Non-Communicating Single Stage Heat Pump
wiring diagram). In both cases airow must be selected
using the tonnage menu where Airow = (400 CFM) x
(Selected Tonnage). Tonnage values range from 1 to 6 in
0.1 increments.
NOTE: Airflow will not go above the system Max
CFM. If the tonnage value selected generates an
airflow value above the Max CFM, the system will
cap this value and not provide any more airflow
than the Max CFM.
R
C
G
Y
Optional
Optional
INDOOR
BOARD TERMINAL
CONNECTIONS
R
C
G
Y
24 VAC
Thermostat
1
2
C
Heat Pump
Optional
R
C
Y
This is the only
case where setting the
thermostat to heat pump
mode is acceptable.
Non-communicating Single Stage Heat Pump
R
C
G
Y
Optional
Optional
Optional if
feature
supported by
thermostat
INDOOR
BOARD TERMINAL
CONNECTIONS
1
2
C
R
C
G
Y
C
Y
Remote
Condensing Unit
(Single-Stage Cooling)
24 VAC
Thermostat
Non-communicating Single Stage A/C
Dehumidification
The control board is equipped with a 24 volt dehum
input in the thermostat wiring connector to be used with
a thermostat or dehumidistat. Dehumidication mode
allows the air handler’s circulator blower to operate at a
slightly lower speed (85% of calculated speed) during a
combined thermostat call for cooling and thermostat call for
dehumidication or dehumidistat call for dehumidication.
This lower blower speed enhances dehumidication of the
conditioned air as it passes through the AC coil. If using the
dehum input with a thermostat, congure the thermostat
to energize this terminal when dehumidication is desired.
If using an external dehumidistat, connect it between the
R and Dehum terminals. The dehumidistat must operate
on 24 VAC and utilize a switch which closes on humidity
rise. Refer to the low voltage wiring diagrams for additional
wiring details.
R
C
G
Y
Dehumidistat
(close on humidity rise)
Dehumidistat (close on humidity rise)
background
SYSTEM OPERATION
12
Key Mitigations:
1. Full featured TS (dehum & overcool)
2. Connect G and dehum wire correctly
3. Dehumidistat
Dehumidification Control Options
1) Install Dehum wire
and DO NOT install G
Wire
2) Install Dehumidistat
in living space or
return duct
Is there a setting in the
thermostat to enable
Dehum without fan? (G)
Yes
No
During a call for Dehum,
does the thermostat
provide 24V to Dehum, Y,
and G?
Yes
No
Choose that setting
Wire the system and test
functionality
Yes
No
Wire the system and
test functionality
Dehumidification Control Options
Dry Environment
Yes
No
Install any 24VAC
thermostat on the
market - Use Y, W, G
signals
Thermostat has a Dehum or
Configurable terminal with
Dehum option
Yes
No
Does your thermostat have a
whole house Dehumidifier
setting?
Install Dehumidistat in
living space or return
duct
If the Dehumidistat
opens on a rise on
humidity, then you
will set Dehum logic
to Low via Coolcloud
app or push buttons
If the Dehumidistat
closes on a rise in
humidity, then you
will set Dehum logic
to High via Coolcloud
app or push buttons
Thermostat only sends Dehum + G on a
call for Dehum
A Dehumidistat needs to be installed in
the living space or return duct
If the Dehumidistat opens
on a rise on humidity,
then you will set Dehum
logic to Low via Coolcloud
app or push buttons
If the Dehumidistat closes on
a rise in humidity, then you will
set Dehum logic to High via
Coolcloud app or push buttons
background
SYSTEM OPERATION
13
Fossil Fuel Applications
This furnace can be used in conjunction with a heat pump
in a fossil fuel application. A fossil fuel application refers to
a combined gas furnace and heat pump installation which
uses an outdoor temperature sensor to determine when to
run the heat pump or gas furnace.
For non-communicating single stage heat pump
installations a fossil fuel kit can be used. Follow the wiring
guidelines in the fossil fuel kit installation instructions.
All furnace connections must be made to the furnace
integrated control module and the “FURNACE” terminal
strip on the fossil fuel control board.
For Fossil Fuel systems the heat pump is given priority
when a compressor balance point lockout condition is not
present. Transitions from primary heat pump heating to
backup gas heating will result in full capacity operation
during the rst thermostat call. The furnace PCB algorithms
will then continuously adjust the stage times or the percent
capacity after the initial call in an attempt to satisfy the
thermostat at the target runtime.
Automatic Fossil Fuel Adjustment: If both compressor
balance point and backup heat balance point lockouts are
not present, the furnace algorithms will determine if the
heat pump is capable of satisfying the thermostat in the
selected target runtime. If the heat pump is not capable
of this it will be locked out until the furnace can satisfy
the thermostat, under the target runtime, while running
completely in low stage. At that point, an attempt will be
given to the heat pump and a decision made to keep using
gas heat or to transition back to the heat pump.
115 Volt Line Connection of Electronic Air
Cleaner
WARNING
High Voltage!
To avoid personal injury or death
due to electrical shock, disconnect
electrical power before servicing or
changing any electrical wiring.
The accessory load specications are as follows:
EAC 1.0 Amp maximum at 120 VAC
The furnace integrated control module is equipped with
a line voltage accessory terminal for controlling power
to an optional eld supplied electronic air cleaner or any
device required to operate in parallel with a circulating fan
demand.
To connect an electronic air cleaner using the
line voltage EAC terminal:
• Turn OFF power to the furnace before installing any
accessories.
• Follow the air cleaner manufacturers’ instructions
for locating, mounting, grounding, and controlling
accessories. Utilize 1/4” quick connect terminals to make
accessory wiring connections to the furnace integrated
control module.
• Connect the hot terminal utilized for accessory operation
to the EAC terminal and the neutral side of power to
NEUTRAL bus on the integrated furnace control or the
neutral connection in the furnace junction box.
• All eld wiring must conform to applicable codes.
• Connections should be made as shown.
• If it is necessary for the installer to supply additional line
voltage wiring to the inside of the furnace, the wiring
must conform to all local codes, and have a minimum
temperature rating of 105°C.
• All line voltage wire splices must be made inside the
furnace junction box.
Low Voltage Ventilation
The Ventilation connections provide dry contact for eld
ventilator wiring connections. These connections are
normally open and energize during the R-32 fault/ alarm
condition. VT IN and VT OUT connections are provided on
the control board and are shown in the image below.
Low Voltage A2L Alarm
The A2L alarm connection provides 24VAC for eld alarm
wiring connections. These connections are normally open
and energize during the R-32 fault/ alarm condition. An A2L
Alarm connection is provided on the control board and is
shown in the image below.
Field Installed Accessories
Additional accessories that do not have dedicated terminals
on the furnace control board may require an additional
daughter board to be installed. Please refer to service
manual on your product for more information.
NOTE: This furnace is equipped with a control
board that is capable of monitoring for R-32
refrigerant leaks in the indoor refrigeration
unit. Please verify that the R-32 sensor wire is
plugged in to the furnace control board before
startup, if applicable. If furnace is not paired
with a R-32 refrigeration system, The default
settings in the furnace control board will need
to be changed. Please see the R-32 section for
additional information.
background
SYSTEM OPERATION
14
Auxiliary Alarm Switch
The control is equipped with a 24VAC Aux Alarm to be
used for a condensate switch install (designated by
“Condensate” on the control). These contacts could also
be used with compatible CO sensors or Fire Alarms. By
default, an AUX switch is normally closed and opens when
the water level in the evaporator coil base pan reaches an
undesirable level. The control will respond by turning o󰀨
the outdoor condensing unit and display EEd. If the AUX
switch is detected closed for 30 seconds, normal operation
resumes and error messages are no longer displayed.
ACCESSORIES
Optional Field installed Supply Air & Return Air
Temperature Sensors
Optional Supply Air Sensor 0130F00933 & Return Air
Sensor 0130F00934 are available for purchase from your
distributor.
Accessory Control (Ventilators)
If an external humidier, dehumidier or ventilator is
installed, it may require airow from the HVAC system to
function accordingly.
1. Make sure the installed 24VAC thermostat is capable of
controlling the accessory or accessories.
2. Connect the appropriate accessory control wires to the
accessory devices from the thermostat (see thermostat
manual for connection and setup instructions).
3. If the thermostat is capable of providing a continuous fan
call (G signal) during accessory operation: Make sure
to connect the thermostat G terminal to the G terminal
on the indoor unit. Setup thermostat to ensure G signal
is energized during accessory operation.
R-32 SENSOR
24 VOLT A2L
ALARM
(OPTIONAL))
24 VOLT VENTILATION
(OPTIONAL)
CONNECTION
LOCATION
FOR RA SENSOR
CONNECTION
LOCATION
FOR SA SENSOR
24 VOLT HUM.
(OPTIONAL)
background
SYSTEM OPERATION
15
4. Select the appropriate fan only airow for the accessory
using the indoor unit push button menus or the
CoolCloud HVAC phone application.
5. Using the thermostat, independently test each accessory
in addition to independently testing continuous fan mode.
Ramping Profiles
The variable-speed circulator o󰀨ers four di󰀨erent ramping
proles. These proles may be used to enhance cooling
performance and increase comfort level. Select ramping
proles on the user menu.
• Prole A (1) provides only an OFF delay of one (1)
minute at 100% of the cooling demand airow.
OFF
100% CFM 100% CFM
1 min
OFF
• Prole B (2) ramps up to full cooling demand airow
by rst stepping up to 50% of the full demand for 30
seconds. The motor then ramps to 100% of the required
airow. A one (1) minute OFF delay at 100% of the
cooling airow is provided.
50% CFM
1/2 min
100% CFM
100% CFM
1 min
OFF
OFF
• Prole C (3) ramps up to 85% of the full cooling
demand airow and operates there for approximately 7
1/2 minutes. The motor then steps up to the full demand
airow. Prole C also has a one (1) minute 100% OFF
delay.
100% CFM
OFF
OFF
• Prole D (4) ramps up to 50% of the demand for 1/2
minute, then ramps to 85% of the full cooling demand
airflow and operates there for approximately 7 1/2
minutes. The motor then steps up to the full demand
airow. Prole D has a 1/2 minute at 50% airow OFF
delay.
OFF
OFF
Cool Cloud HVAC Phone Application – General
Information
Examples of Cool Cloud HVAC Phone Application
Screens
NOTE: Actual screen may look different based on
the device being used.
background
SYSTEM OPERATION
16
This furnace is Bluetooth ready and functions with a
custom phone application designed to improve the setup /
diagnostic experience of the installing contractor.
Users can see specic model information, review active
diagnostic error codes, observe system status during
operation, make system menu adjustments such as the
target runtime, add site visit notes and run system testing
of all operational modes (heat / cool / fan) directly from
the phone. The phone application is also capable of
directly updating the furnace software anytime updates are
available (the application will automatically notify the user
if updates are available). Software update time could take
approximately 15 minutes to complete. The phone must
remain within Bluetooth range for only the download step
of an update. The user will be notied once the download
is completed and installation begins. At this time the phone
can be removed from the Bluetooth range if necessary
(NOTE: if the phone is out of range, the user will not know
when the installation has completed or what the existing
status of the installation is).
Download the CoolCloud Phone Application and create an
account to get started. A Wi-Fi/Cellular connection will be
required for account setup.
Connecting Phone Application to Furnace
When in close proximity to the furnace, the phone
application will detect the Bluetooth Network being
broadcasted by the system. Once the Bluetooth network
is selected by the user, due to security reasons, the user
will be prompted for a 3 digit access code before system
information can be displayed. The 3 digit code will be
displayed on the three seven segment displays of the
furnace control board. A sight glass is located close to the
control board that can be used to see these digits. The
user must enter the access code into the phone application
when prompted to do so in order to gain access to system
information. 3 failed entry attempts will result in a new code
being displayed on the control. If all 3 digits are not visible
from the sight glass, the user has two options to connect.
Option 1) Perform thermostat task as instructed by the
phone application to gain access. The following steps will
explain what this task involves:
• Step 1, ensure the thermostat is in an idol state (no cool,
heat or fan calls). To do this, set the thermostat fan mode
to Auto (not ON) and then remove any active heat / cool
calls. This task needs to be completed within 5 minutes
of the process beginning.
• Step 2, provide any 24VAC call to the control from the
thermostat (cooling, heating or fan will work). This task
must occur within 8 minutes after the Step 1 is complete.
• Step 3, remove the call that was provided during Step
2. This task must be completed within 1 minute after the
call is provided during Step 2.
If the phone remains within Bluetooth range during the
three steps, the user will be notied when each step has
been completed and informed about what to do next. If the
user is not within Bluetooth range during this process the
phone application will still provide instruction about what
tasks to complete. After all 3 steps have successfully been
completed, the user will have access to system information
once in range.
Option 2) Remove the furnace door, ensure the control has
power and then read the 3 digits. The code will temporarily
remain active after a power cycle so the door can put back
on before making the connection if desirable. NOTE:
power will be cycled to the control board with this option. If
it is not desirable to cycle power to the unit for diagnostic
purposes Option 1 may be a better method to connect.
At power-up, the furnace control will display the unit
address (a two digit number) on the 2
nd
and 3
rd
characters
of the three seven segment displays. After the furnace
control has completed its’ internal start-up routine, the
furnace control will display the Status Menu.
The control board will display “Id L” while in idle (stand-by)
mode waiting for a call from the thermostat. The furnace
control is now ready to receive inputs from the room
thermostat.
The furnace control board will detect any compatible
communicating outdoor unit connected to it. Items that
appear in the main menu will vary accordingly. Example,
you will not see heat pump specic menus unless a
compatible heat pump is detected by the furnace control.
background
SYSTEM OPERATION
17
Push Buttons
LEFT
CENTER
RIGHT
Three push-buttons on the control board may be used to
navigate menus and select options. The three buttons are
labeled Left, Center and Right. The center button is used
to enter into the option menu and make the selection, the
left and right buttons are used to browse the main menu
and option menus. When the center button is pressed in
the main menu, the furnace control will go to the option
menu and display the default or previously-selected
option. Pressing the left or right button will display the next
available option. When the next adjustable or selectable
option is displayed, the furnace control will ash the option
with ½ second ON and ½ second OFF indicating the option
has not yet been selected.
To select an option; press and release the center button to
stop the current option from ashing. When the option has
stopped ashing, press the center button again to select
that option.
While navigating through options; if no buttons are
pressed during a 30 second time period, the display will
time-out and return to the Status Menu. Simultaneously
pressing & releasing any two buttons will also return the
furnace control back to the Status Menu. If the previously
displayed option was not selected and a timeout occurs,
the displayed option will not be stored in control memory as
a selected option.
The Status Menu includes the following items:
• The operation mode
• Blower CFM (if blower is running)
• Humidication/Dehumidication mode (if active)
• Ventilator operation (if active)
• Any active fault codes
Menu items will appear in rotation as follows:
• Each item is ON for 2 seconds
• OFF for 1 second
• Then to the next item
Example of Menu Navigation & Option Change
This is an example for how to use the push buttons to
make a change to the constant fan speed.
1. When looking at the Furnace Control, the three 7
Segment displays (located just above the push buttons)
will be displaying system status. System status includes
the current modes of operation, airow and any active
error codes.
LEFT CENTER
RIGHT
Press then Release
2. Press and release the Right Button (this will cycle
through the menus in one direction. Pressing the Left
Button would cycle through the menus in the opposite
direction. For this example, the right button will be used).
3. The screen will now display Menu F10 (Last 10 Faults).
Continue pressing and releasing the Right Button
until you see FSd which is the menu for Constant Fan
Multiplier. Before reaching the FSd menu you will scroll
through Menus F10, Lm, Cr, Sr and rFd.
LEFT CENTER RIGHT
Press then Release
4. Press and release the Center Button. The center button
is used to enter menus and make selections within
menus.
5. What will be displayed is the currently selected fan only
percentage. For this example the assumption is that
this currently selected fan only percentage is 25% and
changing this to 45% is the objective.
6. Press and Release the Right button. The screen will
change to 35 and start ashing. The ashing indicates
the displayed option has not been selected yet.
7. Press and Release the Right button again. The 7
segment displays will continue ashing but will now
display 45.
background
SYSTEM OPERATION
18
LEFT CENTER RIGHT
Press then Release
8. Press and Release the Center Button again. The 45
being displayed will stop ashing. To then complete
the selection process and make 45 the o󰀩cial fan only
setting Press and Release the Center Button for the last
time. This nal step will jump the user back to the main
menu list and FSd will be displayed again.
9. The constant fan multiplier has now been changed from
25 to 45.
Airflow Display
When the blower is running the CFM will be displayed in
Status Menu. The rst 7 segment character will display “A”.
The second & third characters will display the actual CFM
divided by 100. The actual CFM will display rounded up or
down to the nearest 100 CFM as follows:
• 550 to 649 CFM display as “A06”
• 1150 to 1249 CFM display as “A12”
Alarm Display
If an active alarm is present, the alarm code shall be
reported in Status Menu starting with “E” and following with
the appropriate two digit alarm code.
Clearing Faults
While in the Last 10 Faults option menu, push & hold the
center button for 5 seconds. This will clear all non-active
alarm(s) in the Last 10 Faults menu. The display will ash
three times to conrm faults have been cleared.
Learn Menu
Using this option resets the communicating network which
will cause the furnace to discover what devices are present
on ClimateTalk™ network. This menu will not appear when
the furnace control is connected to a Non-Comm OD unit.
Code Release Number Menu
This is a reference only menu to display the rmware
release revision numbers for each micro-controller.
Constant Fan Speed Menu
This menu allows for adjustment of the multiplier for
constant fan operation in 10% increments. Each furnace
has a “Maximum CFM” determined by motor HP. All
fan operations are based o󰀨 of multipliers which are
percentages of this number. Max CFM is shown below. The
default constant fan multiplier is 25%.
Model Max CFM
3 Ton Models 1400
4 Ton Models 1760
5 Ton Models 2200
Gas Heat Airflow Multiplier Menu
The menu is used to change the gas heat airow multiplier
for gas heat operation. In most cases the default gas heat
airow will provide a temperature rise near the middle of
the acceptable range. The multiplier will be expressed by
the 2
nd
& 3
rd
characters of the display as a percentage of
max CFM.
Gas Heat Fan Off Delay Menu
The default setting is 90 seconds. The available adjustment
range is from 30 to 180 seconds in 30 second increments.
Gas Heat Fan On Delay Menu
The default setting is 30 seconds. The available adjustment
range is from 5 to 30 seconds in 5 second increments.
Gas Heat Trim Factor Option Menu
Gas Heat airow may be trimmed from -10% to +10% in
2% increments.
Gas Heat Stage Multiplier Menu (CFM)
This menu allows adjustment of the low re CFM multiplier.
The default CFM for low re is 70% of high re.
Gas Pressure Test Menu
This menu allows 100% ring rate be locked in to check
gas valve pressure.
R-32 INFORMATION
R-32 Function
This furnace is equipped with a control board that is
capable of shutting o󰀨 the gas heat and turning on the
blower fan in case of an R-32 refrigerant leak in the indoor
cooling unit. If the cooling unit that is paired with this
furnace does not utilize R-32 as the refrigerant, the R-32
functionalities in the furnace control board will need to be
turned o󰀨 for the furnace to run properly.
R-32 function on the control board is ON by default. The
R-32 function can be disabled through the furnace control
by entering the A2L Function Enabled menu and selecting
“no”. If A2L function is disabled, the furnace control will
ignore all A2L functions. If A2L function is enabled, the
control will monitor the R-32 sensor information.
To enter the A2L Function Enabled menu, press the left
or right button until LED displays “A2E”. Press the center
button and the LED will display the selected option (yes or
no). Press the left of right button to select one of the two
options and press the center button to conrm the option.
background
SYSTEM OPERATION
19
R-32 Sensor Wire Routing
IMPORTANT NOTE: Wiring routing must not
interfere with circulator blower operation,
filter removal or routine maintenance. Wire
should not be routed near hot surfaces and
should be protected from sharp edges. Extra
precaution should be taken to avoid routing near
the outlet flue pipe.
The R-32 Sensor wire coming from the indoor refrigeration
unit will need to be routed into the furnace and connected
to the connection point on the furnace control board. This
wire should be routed alongside the thermostat wires
through the low voltage openings in the left or right side of
the furnace blower compartment. Please see the electrical
section for the location of the R-32 Sensor connection on
the control board.
Furnace Start Up
During furnace start up, the furnace control will identify the
connected R-32 sensor and will start monitoring the sensor
communication. A green LED located next to the sensor
connection will indicate if there is communication between
the furnace control and the R-32 sensor. The LED will be
ON during the duration of the startup and then will either
start blinking or turn OFF. The blinking LED signies that
communication with the R-32 sensor is present. The LED
OFF signies that there is no signal with the sensor.
If there are no alarms or faults, the furnace will go into
regular run mode after a warm up period. The furnace
control monitors the R-32 sensor once per second.
R-32 Refrigerant Leak
If the R-32 sensor on the indoor cooling unit detects a
specied concentration of R-32 refrigerant, the furnace
will enter Mitigation Mode to dilute the refrigerant
concentrations in case of a leak. In Mitigation Mode, the
furnace will do the following:
1. Display the A2L Refrigerant Leakage error code (EA0)
2. Shut down the gas operation
3. Energize the optional ventilation and alarm outputs.
4. Run the fan at max CFM airow
Once the R-32 sensor stops detecting a leak, the fan will
continue to run for 5 minutes. After the 5 minutes, if there
are no other alarms or faults, the control will de-energize
the optional ventilation and alarm outputs and then go back
to the original operating mode per the thermostat.
A2L Verification
The A2L Function Verication menu allows the installer to
verify if the R-32 function operates properly. This menu
simulates the refrigerant leak process and is only able to
be used when there are no active alarms or faults. To verify
the R-32 functions, enter the A2L Function Verication
menu and select “YES”. To enter the A2L Function
Verication menu, press the left or right button until LED
displays “A2u”. Press the center button and the LED will
display the selected option (yes or no). Press the left of
right button to select one of the two options and press the
center button to conrm the option. Once “YES” is selected,
the furnace will do the following:
1. Display the A2L Refrigerant Leakage code (EA0)
2. Shut down the gas operation
3. Energize the optional ventilation and alarm outputs.
4. Run the fan at max CFM airow
The control will exit the verication function if:
1. The 5 minute timeout expires or
2. An alarm or fault is detected or
3. The user turns OFF the A2L Function Verication.
NORMAL SEQUENCE OF OPERATION
Power Up
The normal power up sequence is as follows:
• 115 VAC power applied to furnace.
• Integrated control module performs internal checks.
• Integrated control module monitors safety circuits
continuously.
• Furnace awaits call from thermostat. 7-segment LED’s
display Id L while awaiting call from thermostat.
Heating Mode
The normal operational sequence in heating mode is
as follows:
• W thermostat contact closes, initiating a call for heat.
• Integrated control module performs safety circuit checks.
• Induced draft blower is energized on high speed for a
15-second prepurge.
• Induced draft blower steps to low speed following
prepurge. Low stage pressure switch contacts are
closed.
• Igniter warm up begins upon Inducer draft blower step
to low speed and presence of closed low stage pressure
switch contacts.
• Gas valve opens at end of igniter warm up period,
delivering gas to burners and establishing ame.
• Integrated control module monitors ame presence. Gas
valve will remain open only if ame is detected.
background
SYSTEM OPERATION
20
• Based on the furnace internal control algorithms the gas
valve and induced draft blower may continue operating
on low stage or both will change to high stage. After a
power cycle, the rst heat call will result in high stage
operation.
• Circulator blower is energized on heat speed following
the selected blower on delay and will begin to ramp
up. Electronic air cleaner terminal is energized with
circulator blower.
• Furnace is now operating on the specified stage
determined by the internal control algorithm.
• Furnace runs, integrated control module monitors safety
circuits continuously.
• If the internal algorithm changes the call from low heat to
high heat, the integrated control module will immediately
switch the induced draft blower, gas valve, and circulator
blower to their high stage settings.
• If the internal algorithm changes the call from high heat to
low heat, the control will immediately switch the induced
draft blower and gas valve to their low stage settings.
The circulator blower will remain on high heating speed
for thirty (30) seconds before switching to the low heat
circulating speed.
• W thermostat contacts open, completing the call for heat.
• Gas valve closes, extinguishing ame.
• Induced draft blower is de-energized following a 15
second post purge.
• Circulator blower continues running for the selected
heat o󰀨 delay period. The speed run during this period
depends on the last heat call provided by the thermostat.
If the last call for heat was a call for low heat, the air
circulator motor will run on low heat speed for the
duration of the heat o󰀨 delay period. If the last call for
heat was a call for high heat, the air circulating motor will
run on the high heating speed for thirty (30) seconds and
then switch to the low heating speed for the remainder
of the heat o󰀨 delay period.
• Circulator blower and electronic air cleaner terminal are
de-energized.
• Circulator blower shuts o󰀨 after the heat o󰀨 delay period
expires.
• Furnace awaits next call from thermostat.
Operational Checks
The burner ames should be inspected with the burner
compartment door installed. Flames should be stable,
quiet, soft, and blue (dust may cause orange tips but
they must not be yellow). Flames should extend directly
outward from the burners without curling, oating, or lifting
o󰀨. Flames must not impinge on the sides of the heat
exchanger ring tubes.
Safety Circuit Description
A number of safety circuits are employed to ensure safe
and proper furnace operation. These circuits serve to
control any potential safety hazards and serve as inputs
in the monitoring and diagnosis of abnormal function.
These circuits are continuously monitored during furnace
operation by the integrated control module.
Integrated Control Module
The integrated control module is an electronic device
which, if a potential safety concern is detected, will take the
necessary precautions and provide diagnostic information
through an LED.
Primary Limit
The primary limit control is located on the partition panel
and monitors heat exchanger compartment temperatures.
It is a normally-closed (electrically), automatic reset,
temperature-activated sensor. The limit guards against
overheating as a result of insu󰀩cient conditioned air
passing over the heat exchanger.
Auxiliary Limit
The auxiliary limit controls are located on or near the
circulator blower and monitors blower compartment
temperatures. They are a normally-closed (electrically),
automatic-reset sensors. These limits guard against
overheating as a result of insu󰀩cient conditioned air
passing over the heat exchanger.
Rollout Limit
The rollout limit controls are mounted on the burner/
manifold assembly and monitor the burner ame. They
are normally-closed (electrically), manual-reset sensors.
These limits guard against burner ames not being properly
drawn into the heat exchanger.
Pressure Switches
The pressure switches are normally-open (closed during
operation) negative air pressure-activated switches. They
monitor the airow (combustion air and ue products)
through the heat exchanger via pressure taps located on
the induced draft blower and the coil front cover. These
switches guard against insu󰀩cient airow (combustion
air and ue products) through the heat exchanger and/or
blocked condensate drain conditions.
Flame Sensor
The ame sensor is a probe mounted to the burner/
manifold assembly which uses the principle of ame
rectication to determine the presence or absence of ame.
background
SYSTEM OPERATION
21
Burner Flame
TROUBLESHOOTING
Electrostatic Discharge (ESD) Precautions
NOTE: Discharge body’s static electricity before
touching unit. An electrostatic discharge can
adversely affect electrical components.
Use the following precautions during furnace installation
and servicing to protect the integrated control module
from damage. By putting the furnace, the control, and
the person at the same electrostatic potential, these steps
will help avoid exposing the integrated control module to
electrostatic discharge. This procedure is applicable to
both installed and uninstalled (ungrounded) furnaces.
1. Disconnect all power to the furnace. Do not touch the
integrated control module or any wire connected to the
control prior to discharging your body’s electrostatic
charge to ground.
2. Firmly touch a clean, unpainted, metal surface of the
furnace away from the control. Any tools held in a
person’s hand during grounding will be discharged.
3. Service integrated control module or connecting wiring
following the discharge process in step 2. Use caution
not to recharge your body with static electricity; (i.e., do
not move or shu󰀪e your feet, do not touch ungrounded
objects, etc.). If you come in contact with an ungrounded
object, repeat step 2 before touching control or wires.
4. Discharge your body to ground before removing a new
control from its container. Follow steps 1 through 3 if
installing the control on a furnace. Return any old or
new controls to their containers before touching any
ungrounded object.
DIAGNOSTIC CHART
WARNING
High Voltage!
To avoid personal injury or death
due to electrical shock, disconnect
electrical power before performing
any service or maintenance.
Refer to the Troubleshooting Chart in the back of this
manual for assistance in determining the source of unit
operational problems. The 7-segment LED displays will
display an error code that may contain a letter and number.
The error code may be used to assist in troubleshooting
the unit.
Resetting From Lockout
Furnace lockout results when a furnace is unable to
achieve ignition after three attempts during a single call for
heat. It is characterized by a non-functioning furnace and
an EE0 code displayed on the 7-segment display. If the
furnace is in “lockout”, it will (or can be) reset in any of the
following ways.
1. Automatic reset. The integrated control module will
automatically reset itself and attempt to resume normal
operations following a one hour lockout period.
2. Manual power interruption. Interrupt 115 volt power to
the furnace.
3. Manual thermostat cycle. Lower the thermostat so that
there is no longer a call for heat for 1 -20 seconds then
reset to previous setting.
NOTE: If the condition which originally caused
the lockout still exists, the control will return
to lockout. Refer to the Troubleshooting Chart
for aid in determining the cause.
background
SCHEDULED MAINTENANCE
22
Annual Inspection
The furnace should be inspected by a qualied installer, or
service agency at least once per year. This check should
be performed at the beginning of the heating season.
This will ensure that all furnace components are in proper
working order and that the heating system functions
appropriately. Pay particular attention to the following
items. Repair or service as necessary.
• Flue pipe system. Check for blockage and/or leakage.
Check the outside termination and the connections at
and internal to the furnace.
• Heat exchanger. Check for corrosion and/or buildup
within the heat exchanger passageways.
• Burners. Check for proper ignition, burner ame, and
ame sense.
• Wiring. Check electrical connections for tightness and/
or corrosion. Check wires for damage.
• Filters.
• R-32 Sensor Wire. Check R-32 sensor wire connection
for tightness and check wire for damage.
FILTERS
Filter Maintenance
Improper lter maintenance is the most common cause of
inadequate heating or cooling performance. Filters should
be cleaned (permanent) or replaced (disposable) every two
months or as required.
Horizontal Unit Filter Removal
Filters in horizontal installations are located in the central
return register or the ductwork near the furnace.
To remove:
1. Turn OFF electrical power to furnace.
2. Remove filter(s) from the central return register or
ductwork.
3. Replace lter(s) by reversing the procedure for removal.
4. Turn ON electrical power to furnace.
Media Air Filter or Electronic Air Cleaner
Removal
Follow the manufacturer’s directions for service.
Burners
Visually inspect the burner ames periodically during the
heating season. Turn on the furnace at the thermostat
and allow several minutes for ames to stabilize, since any
dislodged dust will alter the ames normal appearance.
Flames should be stable, quiet, soft, and blue (dust may
cause orange tips but they must not be yellow). They
should extend directly outward from the burners without
curling, oating, or lifting o󰀨. Flames must not impinge on
the sides of the heat exchanger ring tubes.
Induced Draft and Circulator Blowers
The bearings in the induced draft blower and circulator
blower motors are permanently lubricated by the
manufacturer. No further lubrication is required. Check
motor windings for accumulation of dust which may cause
overheating. Clean as necessary.
Flame Sensor (Qualified Servicer Only)
Under some conditions, the fuel or air supply can create a
nearly invisible coating on the ame sensor. This coating
acts as an insulator causing a drop in the ame sense
signal. If the ame sense signal drops too low the furnace
will not sense ame and will lock out. The ame sensor
should be carefully cleaned by a qualied servicer using
steel wool. Following cleaning, the ame sense signal
should be as indicated in the Specications Sheet.
Flue Passages (Qualified Servicer Only)
The heat exchanger ue passageways should be inspected
at the beginning of each heating season.
REPAIR AND REPLACEMENT PARTS
• When ordering any of the listed functional parts, be sure
to provide the furnace model, manufacturing, and serial
numbers with the order.
• Although only functional parts are shown in the parts
list, all sheet metal parts, doors, etc. may be ordered
by description.
• Parts are available from your distributor.
Functional Parts List-
Gas Valve Blower Motor
Gas Manifold Blower Wheel
Natural Gas Orice Blower Mounting Bracket
Propane Gas Orice Blower Cuto󰀨
Igniter Blower Housing
Flame Sensor Bluetooth Module
Rollout Limit Switch Heat Exchanger with
Primary Limit Switch Recuperator Coil
Auxiliary Limit Switch Coil Front Cover
Pressure Switch Integrated Control Module
Induced Draft Blower Transformer
Door Switch
HEATING PERFORMANCE TEST
Before attempting to diagnose an operating fault code, run
a Heating Performance Test to determine if the heating
system is performing within 5% of the BTU input found on
the rating plate of the unit being tested. To conduct a heating
performance test, the BTU input to the unit must be calculated
(see Clocking a Gas Meter). Before clocking a gas meter,
contact your local utility to obtain the caloric value (BTU
content) of the natural gas in the area.
It is also important to conrm the airow (CFM) is within the
temperature rise range (see Airow Data in spec sheet) and
external static pressure range (approximately 0.5” water
column). How-to instructions can be found in the service
manual under Checking External Static Pressure and
Checking Temperature Rise.
background
SCHEDULED MAINTENANCE
23
CLOCKING A GAS METER
1. Turn o󰀨 all gas appliances in the home.
2. Turn on the furnace. Ensure the furnace is operating at a 100% ring rate on 2 stage and modulating furnace product.
3. Once heating cycle is at a steady state (typically 15 minutes of operation), use a stopwatch to time how long it takes
the smallest unit of measure dial on the gas meter to make a full revolution. In Table 1, one cubic foot is selected. The
smallest unit of measure will vary depending on the gas meter.
CUBIC
FEET
1
1
One
In this example
we are using the
one cubic foot
dial on the gas
meter
TABLE 1
4. Using Table 2 below, nd the number of seconds it took for the dial to make a full revolution. To the right of that num-
ber of seconds and below the Size of Test Dial (selected in step 3 and shown in Table 1) will be the Cubic Feet per
Hour (CFH).
1/4
cu/ft
1/2
cu/ft
1
cu/ft
2
cu/ft
5
cu/ft
1/4
cu/ft
1/2
cu/ft
1
cu/ft
2
cu/ft
5
cu/ft
10 90 180 360 720 1800 36 25 50 100 200 500
11 82 164 327 655 1636 37 -- -- 97 195 486
12 75 150 300 600 1500 38 23 47 95 189 474
13 69 138 277 555 1385 39 -- -- 92 185 462
14 64 129 257 514 1286 40 22 45 90 180 450
15 60 120 240 480 1200 41 -- -- -- 176 439
16 56 113 225 450 1125 42 21 43 86 172 429
17 53 106 212 424 1059 43 -- -- -- 167 419
18 50 100 200 400 1000 44 -- 41 82 164 409
19 47 95 189 379 947 45 20 40 80 160 400
20 45 90 180 360 900 46 -- -- 78 157 391
21 43 86 171 343 857 47 19 38 76 153 383
22 41 82 164 327 818 48 -- -- 75 150 375
23 39 78 157 313 783 49 -- -- -- 147 367
24 37 75 150 300 750 50 18 36 72 144 360
25 36 72 144 288 720 51 -- -- -- 141 355
26 34 69 138 277 692 52 -- -- 69 138 346
27 33 67 133 265 667 53 17 34 -- 136 340
28 32 64 129 257 643 54 -- -- 67 133 333
29 31 62 124 248 621 55 -- -- -- 131 327
30 30 60 120 240 600 56 16 32 64 129 321
31 -- -- 116 232 581 57 -- -- -- 126 316
32 28 56 113 225 563 58 -- 31 62 124 310
33 -- -- 109 218 545 59 -- -- -- 122 305
34 26 53 106 212 529 60 15 30 60 120 300
35 -- -- 103 206 514
GAS RATE -- CUBIC FEET PER HOUR
Seconds fo
r
One
Revolution
Size of Test Dial
Seconds fo
r
One
Revolution
Size of Test Dial
Locate 40 seconds for one
revolu�on in the chart below
Then locate the 1 cu � dial column and select the
corresponding CFH from the 40 seconds for one revolu�on row
TABLE 2
background
SCHEDULED MAINTENANCE
24
5. Use this formula to verify the Cubic Feet per Hour (CFH) input determined in step 4 is correct:
(3600 x Gas Meter Dial Size) / Time (seconds) = Cubic Feet per Hour (CFH)
3600 is used as there are 60 seconds in
a minute and 60 minutes in an hour.
60x60=3600
6. Check with your local utility for actual BTU content (caloric value) of natural gas in the area (the average is 1025
BTU’s).
7. Use this formula to calculate the BTU/HR input (See BTU/HR Calculation Example):
Cubic Feet per Hour (CFH) x BTU content of your natural gas = BTU/HR input
8. Should the gure you calculated not fall within ve (5) percent of the nameplate rating of the unit, adjust the gas valve
pressure regulator. To adjust the pressure regulator on the gas valve, turn downward (clockwise) to increase pressure
and input, and upward (counterclockwise) to decrease pressure and input. A properly operating unit must have the
BTU per hour input and CFM of air, within the limits shown to prevent short cycling of the equipment. As the external
static pressure goes up, the temperature rise will also increase. Consult the proper tables for temperature rise limita-
tion.
BTU/HR Calculation Example:
The unit being tested takes 40 seconds for the 1 cubic foot dial to make one complete revolution. Using the chart, this
translates to 90 cubic feet per hour. Based upon the assumption that one cubic foot of natural gas has 1,025 BTU’s (Check
with your local utility for actual BTU content), the calculated input is 92,250 BTU’s per hour.
Furnace Nameplate Input in this example: 90,000 BTU/HR
Calculated Gas Input in this example: 92,250 BTU/HR
This example is within the 5% tolerance input and does not need adjustment.
background
SERVICING
25
As more and more electronics are introduced to the Heating
Trade, Polarization of incoming power and phasing of primary
to secondary voltage on transformers becomes more import-
ant.
Polarization has been apparent in the Appliance industry since
the introduction of the three prong plug, however, the Heating
Industry does not use a plug for incoming power, but is hard
wired.
Some of the electronic boards being used today, with ame
rectication, will not function properly and/or at all without
polarization of incoming power. Some also require phasing
between the primary and secondary sides of step-down trans-
formers.
We recommend that these two items be checked during nor-
mal installation and/or service calls. See as follows:
CHECKING FOR PHASING - PRIMARY TO SECONDARY OF UNMARKED TRANSFORMERS*
If meter reads approximately 96 volts - the primary to secondary are in phase - if reads approximately 144 volts out of
phase - reverse low voltage wires.
*NOTE: For ame rectication the common side of the secondary voltage (24 V) is cabinet grounded. If you were to bench
test a transformer the primary neutral and secondary common must be connected together for testing purposes.
These then should be wired to the furnace accordingly.
Some transformers will display phasing symbols as shown
in the illustration to the left to assist in determining proper
transformer phasing.
Checking for polarization and phasing should become a
habit in servicing. Lets start now.
background
SERVICING
26
CHECKING VOLTAGE
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove the burner door.
2. Remove cover from the Junction Box and gain access
to incoming power lines.
With Power ON:
WARNING
Line voltage now present
3. Using a voltmeter, measure the voltage across the hot
and neutral connections.
NOTE: To energize the furnace, the Door
Interlock Switch must be engaged at this point.
4. No reading - indicates open wiring, open fuse, no
power, or faulty Door Interlock Switch from unit to fused
disconnect service. Repair as needed.
5. With ample voltage at line voltage connectors, energize
the furnace blower motor by jumpering terminals R to G
on the integrated ignition control.
6. With the blower motor in operation, the voltage should
be 115 volts ± 10 percent.
7. If the reading falls below the minimum voltage, check
the line wire size. Long runs of undersized wire can
cause low voltage. If wire size is adequate, notify the
local power company of the condition.
8. After completing check and/or repair, replace Junction
Box cover and reinstall the service panel doors.
9. Turn on electrical power and verify proper unit operation.
CHECKING WIRING
WARNING
Disconnect ALL power before servicing
1. Check wiring visually for signs of overheating, damaged
insulation and loose connections.
2. Use an ohmmeter to check continuity of any suspected
open wires.
3. If any wires must be replaced, replace with AWM,
105°C. 2/64 inch thick insulation of the same gauge or
its equivalent.
CHECKING THERMOSTAT, WIRING
WARNING
Disconnect ALL power before servicing
1. Remove the blower compartment door to gain access to
the thermostat low voltage wires located at the furnace
integrated control module terminals.
2. Remove the thermostat low voltage wires at the furnace
control panel terminal board.
3. Jumper terminals R to W on the integrated ignition
control.
With Power On (and Door Interlock Switch closed):
WARNING
Line voltage now present
4. Induced Draft Motor must run and pull in pressure switch.
5. If the hot surface ignitor heats and at the end of the ignitor
warm-up period the gas valve opens and the burners
ignite, the trouble is in the thermostat or wiring.
6. With power o󰀨, check the continuity of the thermostat
and wiring. Repair or replace as necessary.
If checking the furnace in the air conditioning mode,
proceed as follows:
7. With power o󰀨, Jumper terminals R to Y to G.
8. Turn on the power.
9. If the furnace blower motor starts and the condensing
unit runs, then the trouble is in the thermostat or wiring.
Repair or replace as necessary.
10. After completing check and/or repair of wiring and
check and/or replacement of thermostat, reinstall blower
compartment door.
11. Turn on electrical power and verify proper unit operation.
CHECKING TRANSFORMER AND CONTROL
CIRCUIT
A step-down transformer 120 volt primary to 24 volt
secondary, 40 VA (Heating and Cooling Models) supplies
ample capacity of power for either operation.
background
SERVICING
27
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove blower compartment door to gain access to
the thermostat low voltage wires located at the furnace
integrated control module.
2. Remove the thermostat low voltage wires at the furnace
integrated control module terminals.
With Power On (and Door Interlock Switch closed):
WARNING
Line voltage now present
3. Use a voltmeter, check voltage across terminals R and
C. Must read 24 VAC.
4. No voltage indicates faulty transformer, open fuse, bad
wiring, bad splice, or open door interlock switch.
5. Check transformer primary voltage at incoming line
voltage connections, fuse, splices, and blower door
interlock switch.
6. If line voltage is available to the primary side of
transformer and not at secondary side, the transformer
is inoperative. Replace.
7. After completing check and/or replacement of transformer
and check and/or repair of control circuit, reinstall blower
compartment door.
8. Turn on electrical power and verify proper unit operation.
4-Wire ECM Motors
Description
These models utilize a Nidec US motors, 4-wire variable
speed ECM blower motor. The ECM blower motor
provides constant CFM.
The motor is a serially communicating variable speed
motor. Only four wires are required to control the motor:
+Vdc, Common, Receive, and Transmit.
The +Vdc and Common wires provide power to the motor’s
low voltage control circuits. Typical supply voltage is 9-15
volts DC.
CHECKING AIR CIRCULATION BLOWER
MOTOR (ECM MOTORS)
ECM Control Connections
ECM control connections are made through the integrated
ignition control. No other control connections are needed.
Checking ECM Motors
ECM motors connect directly to the AC Line Voltage. DO
NOT insert contactors in series with the ECM Motor AC
Line. The control is powered continuously to insure reliable
start-up. The connector plug is polarized, verify and reverify
correct connector orientation before applying power. DO
NOT force plug into motor and make sure power is o󰀨
before inserting power connector. DO NOT apply voltage to
terminals 1 or 2.
General Checks/Considerations
1. Check power supply to the furnace. Ensure power
supply is within the range specied on rating plate.
2. Check motor power harness. Ensure wires are
continuous and make good contact when seated in the
connectors. Repair or replace as needed.
3. Check motor control harness. Ensure wires are
continuous and make good contact when seated in the
connectors. Repair or replace as needed.
4. Check thermostat and thermostat wiring. Ensure
thermostat is providing proper cooling/heating/
continuous fan demands. Repair or replace as needed.
5. Check blower wheel. Conrm wheel is properly seated
on motor shaft. Set screw must be on shaft at and
torqued to 165 in-lbs minimum. Conrm wheel has no
broken or loose blades. Repair or replace as needed.
6. Ensure motor and wheel turn freely. Check for
interference between wheel and housing or wheel and
motor. Repair or replace as needed.
7. Check housing for cracks and/or corrosion. Repair or
replace as needed.
8. Check motor mounting bracket. Ensure mounting
bracket is tightly secured to the housing. Ensure bracket
is not cracked or broken.
UltraCheck-EZ
TM
Diagnostic Tool
The UltraCheck-EZ
TM
diagnostic tool is the preferred
method (part # UTT-01) to diagnose the ECM motor.
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
To use the diagnostic tool, perform the following steps:
1. Disconnect power to the furnace.
2. Disconnect the 4-circuit control harness from the motor.
3. Plug the 4-circuit connector from the diagnostic tool into
the motor control connector.
4. Connect one alligator clip from the diagnostic tool to a
ground source.
background
SERVICING
28
5. Connect the other alligator clip to a 24VAC source.
NOTE: The alligator clips are NOT polarized.
NOTE: The UltraCheck-EZ
TM
diagnostic tool
is equipped with a non-replaceable fuse.
Connecting the tool to a source other than
24VAC could damage the tool and cause the fuse
to open. Doing so will render the diagnostic tool
inoperable.
6. Turn on power to the furnace.
WARNING
Line voltage now present
7. Depress the orange power button on the diagnostic tool
to send a run signal to the motor. Allow up to 5 seconds
for the motor to start.
NOTE: If the orange power button does not
illuminate when depressed, the tool either has
an open fuse or is not properly connected to a
24VAC source.
8. The green LED on the diagnostic tool will blink indicating
communications between the tool and motor. See table
below for indications of tool indicators and motor actions.
Replace or repair as needed.
Power
Button
Green
LED
Motor
Action
Indication(s)
OFF OFF
Not
Rotating
Confirm 24VAC to
UltraCheck-EZ
TM
tool.
If 24VAC is confirmed,
diagnostic tool is
inoperable.
ON Blinking
Rotating
Motor and control/end
bell are functioning
properly.
ON OFF
Rotating
Replace motor
control/end bell.
ON Blinking
Not
Rotating
Check motor (see
Motor Check s below).
ON OFF
Not
Rotating
Replace motor
control/end bell; verify
motor (see Motor
Check s below).
9. Depress the orange power button to turn o󰀨 motor.
10. Disconnect power. Disconnect diagnostic tool.
11. Reconnect the 4-wire harness from control board to
motor.
Electrical Checks - High Voltage Power Circuits
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Disconnect power to the furnace.
2. Disconnect the 5-circuit power connector to the ECM
motor.
3. Turn on power to the furnace.
WARNING
Line voltage now present
4. Measure voltage between pins 4 and 5 on the 5-circuit
connector. Measured voltage should be the same as
the supply voltage to the furnace.
5
4
3
2
1
Lines 1 and 2 will be connected
for 120VAC Power Connector
applications only
Gnd
AC Line Neutral Connection
AC Line Hot Connection
}
Power Connector
“Motor Half”
(Viewed from Plug End)
5. Measure voltage between pins 4 and 3. Voltage should
be approximately zero.
6. Measure voltage between pins 5 and 3. Voltage should
be the same as the supply voltage to the furnace.
7. If no voltage is present, check supply voltage to the
furnace.
8. Disconnect power to the furnace. Reconnect the
5-circuit power harness disconnected in step 2.
Electrical Checks - Low Voltage Control Circuits
1. Turn on power to the furnace.
background
SERVICING
29
WARNING
Line voltage now present
2. Check voltage between pins 1 and 4 on the 4-wire motor
control harness between the motor and control board.
Voltage should be between 3 and 15 VDC.
3. If no voltage is present, check control board.
Motor Control/End Bell Checks
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Disconnect power to the furnace.
NOTE: Motor contains capacitors that can hold a
charge for several minutes after disconnecting
power. Wait 5 minutes after removing power to
allow capacitors to discharge.
2. Disconnect the motor control harness and motor power
harness.
3. Remove the blower assembly from the furnace.
4. Remove the (3) screws securing the control/end bell to
the motor. Separate the control/end bell. Disconnect the
3-circuit harness from the control/end bell to remove the
control/end bell from the motor.
5. Inspect the NTC thermistor inside the control/end bell
(see gure below). Replace control/end bell if thermistor
is cracked or broken.
6. Inspect the large capacitors inside the control/end bell
(see gure below). Replace the control/end bell if any
of the capacitors are bulging or swollen.
7. Locate the 3-circuit connector in the control/end bell.
Using an ohmmeter, check the resistance between each
terminal in the connector. If the resistance is 100kW
or greater, the control/end bell is functioning properly.
Replace the control/end bell if the resistance is lower
than 100kW.
8. Reassemble motor and control/end bell in reverse of
disassembly. Replace blower assembly into the furnace.
Motor Checks
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Disconnect power to the furnace.
NOTE: Motor contains capacitors that can hold a
charge for several minutes after disconnecting
power. Wait 5 minutes after removing power to
allow capacitors to discharge.
2. Disassemble motor as described in steps 2 through 4
above.
3. Locate the 3-circuit harness from the motor. Using an
ohmmeter, measure the resistance between each motor
phase winding. The resistance levels should be equal.
Replace the motor if the resistance levels are unequal,
open circuited or short circuited.
4. Measure the resistance between each motor phase
winding and the motor shell. Replace the motor if any
phase winding is short circuited to the motor shell.
5. Reassemble motor and control/end bell in reverse of
disassembly. Replace blower assembly into the furnace.
background
SERVICING
30
To determine proper air movement, proceed as follows:
1. With clean lters in the furnace, use a manometer to
measure the static pressure of the return duct at the
inlet of the furnace. (Negative Pressure)
2. Measure the static pressure of the supply duct. (Positive
Pressure)
3. Add the two (2) readings together for total external static
pressure.
NOTE: Both readings may be taken simultaneously
and read directly on the manometer if so
desired. If an air conditioner coil or Electronic
Air Cleaner is used in conjunction with the
furnace, the readings must also include theses
components, as shown in the following drawing.
4. Consult proper tables for the quantity of air.
If the total external static pressure exceeds the minimum
or maximum allowable statics, check for closed dampers,
registers, undersized and/or oversized poorly laid out duct
work.
CHECKING DUCT STATIC
WARNING
Never allow the products of combustion,
including carbon monoxide, to enter the return
duct work or circulation air supply.
Refer to your furnace rating plate for the maximum ESP
(external duct static) rating.
Total external static refers to everything external to the
furnace cabinet. Cooling coils, lters, ducts, grilles,
registers must all be considered when reading your total
external static pressure. The supply duct pressure must be
read between the furnace and the cooling coil. This reading
is usually taken by removing the “A” shaped block o󰀨
plate from the end on the coil; drilling a test hole in it and
reinstalling the block o󰀨 plate. Take a duct static reading
at the test hole. Tape up the test hole after your test is
complete. The negative pressure must be read between
the lter and the furnace blower.
Too much external static pressure will result in insu󰀩cient
air that can cause excessive temperature rise. This can
cause limit switch tripping and heat exchanger failure.
To determine total external duct static pressure, proceed as
follows:
1. With clean lters in the furnace, use a manometer to
measure the static pressure of the return duct at the
inlet of the furnace. (Negative Pressure)
2. Measure the static pressure of the supply duct. (Positive
Pressure)
3. The di󰀨erence between the two numbers is the total
external static pressure.
Example:
-1
0
1 2
3
Difference is 4
static reading from return duct = -.1” w.c.
static reading from supply duct = .3” w.c.
total external static pressure on this system = .4” w.c.
4. Consult proper tables for the quantity of air.
If the total external static pressure exceeds the maximum
listed on the furnace rating plate, check for closed
dampers, registers, undersized and/or oversized poorly laid
out duct work.
The temperature rise of the furnace must be within the
temperature rise range listed on the furnace rating plate.
.
Checking Static Pressure
CHECKING TEMPERATURE RISE
The more air (CFM) being delivered through a given
furnace, the less the rise will be; so the less air (CFM)
being delivered, the greater the rise. The temperature
rise should be adjusted in accordance to a given furnace
specications and its external static pressure. An incorrect
temperature rise may result in condensing in or overheating
of the heat exchanger. An airow and temperature rise
table is provided in the blower performance specication
section. Determine and adjust temperature rise as follows:
background
SERVICING
31
1. Operate furnace with burners ring for approximately ten
minutes. Check BTU input to furnace - do not exceed
input rating stamped on rating plate. Ensure all registers
are open and all duct dampers are in their nal (fully or
partially open) position.
2. Place thermometers in the return and supply ducts as
close to the furnace as possible. Thermometers must
not be inuenced by radiant heat by being able to “see”
the heat exchanger.
SUPPLY
AIR
RETURN
AIR
Temperature Rise Measurement
3. Subtract the return air temperature from the supply air
temperature to determine the air temperature rise. Allow
adequate time for thermometer readings to stabilize.
4. Adjust temperature rise by adjusting the circulator
blower speed. Increase blower speed to reduce
temperature rise. Decrease blower speed to increase
temperature rise. Refer to Circulator Blower Speed
section in the Product Design section of this manual
for speed changing details. Temperature rise is related
to the BTUH output of the furnace and the amount of
air (CFM) circulated over the heat exchanger. Measure
motor current draw to determine that the motor is not
overloaded during adjustments.
CHECKING PRIMARY LIMIT CONTROL
Primary limit controls are nonadjustable, automatic reset,
bi-metal type limit control. Refer to the following drawing
for the location of the primary limit.
ENCLOSED DISK
FRONT VIEW SIDE VIEW
Primary Limit Control Style
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove burner compartment door to gain access to
the primary limit.
2. Remove low voltage wires at limit control terminals.
3. With an ohmmeter, test between these two terminals as
shown in the following drawing. The ohmmeter should
read continuous unless heat exchanger temperature is
above limit control setting. If not as above, replace the
control.
COLOR
IDENTIFYING
TAB
Testing Primary Limit Control
4. After completing check and/or replacement of primary
limit control, reinstall burner compartment door.
5. Turn on electrical power and verify proper unit operation.
background
SERVICING
32
To aid in identifying these controls, refer to the Primary
Limit Charts in furnace Technical Manual for part number,
temperature setting and color(s) code.
CHECKING AUXILIARY LIMIT CONTROL
The auxiliary limit control is designed to prevent furnace
operation in case of main blower failure in horizontal or
counterow installations. It may also open if the power
supply is interrupted while the furnace is ring.
The auxiliary limit control is suitable for both horizontal
right and horizontal left installations. Regardless of airow
direction, it does not need to be relocated. The (2) two
auxiliary limits are located on the blower housing (one on
each side), as shown in the following illustration.
BLOWER HOUSING
AUXILIARY LIMIT CONTROL
LIMIT
AUXILIARY LIMIT
CONTROL
AUXILIARY LIMIT
CONTROL
BLOWER HOUSING
Auxiliary Limit Control Location
Manual or Automatic Reset Auxiliary Limits
Located in Blower Side
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove the wires from the auxiliary limit control
terminals.
2. Using an ohmmeter, test for continuity across the two
terminals (only test when the auxiliary limit is at room
temperature).
RED
RESET
BUTTON
COLOR
IDENTIFYING
Testing Auxiliary Limit Control
WARNING
To avoid possible fire, only reset the auxiliary
limit control once. If it should open a second
time, a qualified servicer must determine why
the auxiliary limit opened before resetting
again.
CHECKING FLAME ROLLOUT CONTROL
A temperature activated manual reset control is mounted to
the manifold assembly.
The control is designed to open should a ame roll out
occur. An over ring condition or ame impingement on
the heat shield may also cause the control to open. If the
rollout control opens, the air circulation blower will run
continuously.
background
SERVICING
33
WARNING
Line voltage now present
1. Remove the burner compartment door to gain access to
the rollout switch(es) mounted to burner bracket.
2. Reset the manual rollout switch.
3. Remove wires from rollout switch.
4. Using an ohmmeter, check for continuity across the
switch.
5. If the switch will not close after manually resetting, it
must be replaced.
If a roll out switch has tripped, it is important to nd out
why. Possible causes could be ame impingement, orice
plate out of position, burners with excessive cross-over
slot dimension, over-ring, improper orices, improper
gas pressure, air leaking from around the heat exchanger
into the burner compartment, air leaking through the heat
exchanger itself.
6. After check and/or replacement of rollout switch,
reinstall burner compartment door and verify proper
unit operation.
INDUCED DRAFT BLOWER MOTOR
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove burner compartment door to gain access to the
induced draft blower motor.
2. Disconnect the motor wire leads from its connection
point at the induced draft motor.
3. Using a ohmmeter, test for continuity between each of
the motor leads. If the windings do not test continuous,
replace the motor.
4. Touch one probe of the ohmmeter to the motor frame
(ground) and the other probe in turn to each lead
If a reading is obtained to ground, replace the motor.
5. If the windings have a continuity reading, reconnect
wires. Turn power on to the furnace and turn the
thermostat on in the heating mode. Check voltage for
115V at the induced draft motor terminals during the trial
for ignition. If you have 115V and the motor does not
run, replace the induced draft motor.
6. After completing check and/or replacement of induced
draft motor, reinstall burner compartment door.
7. Turn on electrical power and verify proper unit operation.
CHECKING GAS VALVE (REDUNDANT)
A combination redundant operator type gas valve which
provides all manual and automatic control functions
required for gas red heating equipment is used.
The valve provides control of main burner gas ow,
pressure regulation, and 100 percent safety shut-o󰀨.
Two stage gas valves always require 24 volts between
common and low re (main coil) to open.
Low (Main)
Common
High
White-Rodgers 2-Stage Valve
WARNING
Disconnect ALL power before servicing
CHECKING MAIN BURNERS
The main burners are used to provide complete
combustion of various fuels in a limited space, and transfer
this heat of the burning process to the heat exchanger.
Proper ignition, combustion, and extinction are primarily
due to burner design, orice sizing, gas pressure, primary
and secondary air, vent and proper seating of burners.
Burners
Burners have been redesigned for 34.5” chassis furnaces.
Overall length and width dimensions remain the same as
40” model burners. The burners used 34.5” models have
burner head insert with larger diameter center hole and a
larger number of surrounding holes.
background
SERVICING
34
New 34.5 Burners
WARNING
Disconnect ALL gas and electrical power supply.
In checking main burners, look for signs of rust, oversized
and undersized carry over ports restricted with foreign
material, etc., burner cross-over slots should not be altered
in size.
CHECKING ORIFICES
*RVT80/*DVT80 model furnaces have factory installed #45
natural gas orices.
The only time replacement is required is when a reduction
in ring rate is required for an increase in altitude or a
furnace is being converted for use with L.P. gas.
Orices should be treated with care in order to prevent
damage. They should be removed and installed with a box-
end wrench in order to prevent distortion. In no instance
should an orice be peened over and re-drilled. This will
change the angle or deection of the vacuum e󰀨ect or
entraining of primary air, which will make it di󰀩cult to adjust
the ame properly. This same problem can occur if an
orice spud of a di󰀨erent length is substituted.
WARNING
Disconnect ALL gas and electrical power supply.
1. Check orice visually for distortion and/or burrs.
2. Check orice size by the number stamped on the orice.
A
GAS
STREAM
B
The length of Dimension “A” determines the angle of Gas
Stream “B”.
DENT OR
BURR
GAS
STREAM
B
A dent or burr will cause severe deection of the gas
stream.
CHECKING GAS PRESSURE
Gas Supply Pressure Measurement
CAUTION
To prevent unreliable operation or equipment
damage, the inlet gas supply pressure must
be as specified on the unit rating plate with
all other household gas fired appliances
operating.
Gas inlet and manifold pressures should be checked and
adjusted in accordance to the type of fuel being consumed.
The line pressure supplied to the gas valve must be within
the range specied below. The supply pressure can be
measured at the gas valve inlet pressure tap or at a hose
tting installed in the gas piping drip leg. The supply
pressure must be measured with the burners operating.
To measure the gas supply pressure, use the following
procedure.
WARNING
Disconnect electrical power and shut off gas
supply.
1. After turning off gas to furnace at the manual gas
shuto󰀨 valve external to the furnace, remove burner
compartment door to gain access to the gas valve.
2. Connect a calibrated manometer (or appropriate gas
pressure gauge) at either the gas valve inlet pressure
tap or the gas piping drip leg as shown in the following
gures.
background
SERVICING
35
NOTE: At either location, a hose fitting must be
installed prior to making the hose connection.
NOTE: Use adapter kit #0151K00000S to measure
gas pressure on White-Rodgers 36J gas valves.
3. Turn ON the gas and electrical power supply and operate
the furnace and all other gas consuming appliances on
the same gas supply line.
4. Measure furnace gas supply pressure with burners ring.
Supply pressure must be within the range specied in
the following table.
Inlet Gas Supply Pressure
Natural Gas Minimum: 4.5” w.c. Maximum: 10.0” w.c.
Propane Gas Minimum: 11.0” w.c. Maximum: 13.0” w.c.
If supply pressure di󰀨ers from above, make necessary
adjustments to pressure regulator, gas piping size, etc.,
and/or consult with local gas utility.
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
5. Disconnect manometer after turning o󰀨 gas at manual
shuto󰀨 valve. Reinstall plug before turning on gas to
furnace.
6. Turn OFF any unnecessary gas appliances started in
step 3.
7. Turn on gas to furnace and check for leaks. If leaks are
found, repair and then reinstall burner compartment door.
8. Turn on electrical power and verify proper unit operation.
M
a
no
m
e
t
er
M
a
n
o
m
e
t
e
r
H
o
s
e
High Fire Regulator
Adjust
Regulator
Vent
O
n
/O
f
f S
w
i
tc
h
H
ig
h
Fi
re
C
oi
l
T
e
rm
i
na
l
(
H
I)
C
o
a
x
i
al
C
o
il
Te
r
m
in
a
l
(
M
)
Common
Terminal(C)
White-Rodgers Model 36J54 Connected to Manometer
3.5
Measuring Manifold Gas Pressure
(36J54 Valve)
WARNING
High Voltage!
Disconnect ALL electrical power and shut off
gas supply before servicing or installing.
Manifold Gas Pressure
Gas Rate Range Nominal
Natural Gas
High Stage 3.2 to 3.8”
w.c.
3.5” w.c.
Low Stage 1.6 to 2.2”
w.c.
1.9” w.c.
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
Manifold Gas Pressure
Gas Rate Range Nominal
Propane Gas
High Stage 9.7 to 10.3”
w.c.
10.0” w.c.
Low Stage 5.7 to 6.3” w.c. 6.0” w.c.
background
SERVICING
36
CHECKING HOT SURFACE IGNITOR
120V Silicon Nitride Igniter - Amana® Brand and
Goodman® Brand furnaces use a 120V silicon nitride
igniter for ignition. The normal operating temperature is
approximately 2156°F - 2678°F.
WARNING
Disconnect ALL power before servicing.
1. Remove burner compartment door to gain access to
the ignitor.
2. Ignitor cool - approximately 70 - 77°F.
3. Disconnect the ignitor from the Ignition Control.
4. Using an ohmmeter measure the resistance of the ignitor:
120 Volt Silicon Nitride : 120V Nitride Igniter should read
between 37 to 68 ohms.
5. Reconnect ignitor.
WARNING
Line voltage now present
6. Place unit in heating cycle, measure current draw of
ignitor during preheat cycle. The steady state current
at 120V is 0.37 to 0.68 amps.
7. After checking and/or replacing of hot surface ignitor,
reinstall burner compartment door and verify proper
unit operation.
CHECKING FOR FLASHBACK
Flashback will also cause burning in the burner venturi, but
is caused by the burning speed being greater than the gas-
air ow velocity coming from a burner port.
Flashback may occur at the moment of ignition, after a
burner heats up or when the burner turns o󰀨. The latter is
known as extinction pop.
Since the end results of ashback and delayed ignition
can be the same (burning in the burner venturi) a denite
attempt should be made to determine which has occurred.
If ashback should occur, check for the following:
1. Improper gas pressure - adjust to proper pressure.
2. Check burner for proper alignment and/or replace burner.
3. Improper orice size - check orice for obstruction.
CHECKING PRESSURE SWITCH
The pressure control is a safety device to prevent the
combustion cycle from occurring with inadequate venting
caused by a restricted or blocked vent pipe.
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Remove burner compartment door to gain access to
pressure switch(es).
2. Remove wires from the pressure switch(es) electrical
terminals.
3. Remove the pressure control hose from the control
and interconnect with a manometer as shown in the
following gure.
4. With an ohm meter connected across the pressure
switch terminals and with the inducer running, the switch
should close and the ohm meter should show a complete
circuit across the pressure switch. If the switch is not
closed, compare the negative pressure to the closing
point specied for the particular switch. Either the switch
is defective or the inducer/venting system is inadequate.
-.
OPEN TO
ATMOSPHERE
HOSE TO INDUCED
DRAFT BLOWER TAP
1/4" TEE
INDUCED DRAFT BLOWER
PRESSURE SWITCH
PRESSURE SWITCH
HOSE
INDUCED
DRAFT
BLOWER
*
*
*
* *
*
*
M
1
2
3P
C
ON
O
F
F
FRONT COVER
PRESSURE SWITCH
Blower Pressure Switch
Negative Pressure Measurement
HIGH ALTITUDE APPLICATION (USA)
When furnaces are installed at high altitude, the
appropriate High Altitude Orice or Pressure Switch
Kit must be applied. This is required due to the natural
reduction in the density of both the gas fuel and
combustion air as altitude increases. The High Altitude
Orice Kit will provide the proper design certied input rate
within the specied altitude range.
High Altitude Orice or Pressure Switch Kits are purchased
according to the installation altitude and usage of
either natural or propane gas. Refer to the Technical
Manual or product Specication Sheet for a tabular
listing of appropriate altitude ranges and corresponding
manufacturer’s high altitude (Natural or Propane Gas)
orice or pressure switch kits.
background
SERVICING
37
Do not derate the furnace by adjusting the manifold
pressure to a lower pressure than specied on the furnace
rating plate. The combination of the lower air density and
a lower manifold pressure will prohibit the burner orice
from drawing the proper amount of air into the burner. This
may cause incomplete combustion, ashback, and possible
yellow tipping.
In some areas the gas supplier may articially derate the
gas in an e󰀨ort to compensate for the e󰀨ects of altitude.
If the gas is articially derated the appropriate orce size
must be determined based on the BTU/ft3 content of
the derated gas and the altitude. Refer to the National
Fuel Gas Code, NFPA 54/ANSI Z223.1, and information
provided by the gas supplier to determine the proper orice
size.
CHECKING FOR DELAYED IGNITION
Delayed ignition is a delay in lighting a combustible mixture
of gas and air which has accumulated in the combustion
chamber.
If delayed ignition should occur, the following should be
checked. Furnace design makes this extremely unlikely
unless safety controls have been by-passed or tampered
with. Never by-pass or alter furnace controls.
1. Improper gas pressure - adjust to proper pressure.
2. Improper burner positioning - burners should be in
locating slots, level front to rear and left to right.
3. Carry over (lighter tube or cross lighter) obstructed -
clean.
4. Main burner orice(s) deformed, or out of alignment to
burner - replace.
CHECKING INTEGRATED IGNITION CONTROL
BOARDS
NOTE: Failure to earth ground the furnace,
reversing the neutral and hot wire connection
to the line (polarity), or a high resistance
connection in the neutral line may cause the
control to lockout due to failure to sense flame.
WARNING
To avoid the risk of electrical shock, wiring
to the unit must be properly polarized and
grounded. Disconnect power before performing
service listed below.
The ground wire must run from the furnace all the way back
to the electrical panel. Proper grounding can be conrmed
by disconnecting the electrical power and measuring
resistance between the neutral (white) connection and the
burner closest to the ame sensor. Resistance should be
less than 10 ohms.
The ignition control is a combination electronic and
electromechanical device and is not eld repairable.
Complete unit must be replaced.
WARNING
Line voltage now present
These tests must be completed within a given time frame
due to the operation of the ignition control. The trial for
ignition period is 4 seconds.
The ignition control is capable of diagnosing many furnace
failures to help in troubleshooting. The control utilizes a
dual, 7-segment LED display to indicate diagnostic codes.
When the control is powered up normally the light will be on
continuously. The display will indicate “ON” when powered
and in standby mode. This can be used to test for 120 volts
and 24 volts to the control since both must be present for
the light to be on. If this step fails, check for 120 volts to the
control and check the transformer and its associated wiring.
If this step is successful give the control a call for heat and
wait ve (5) seconds or until the furnace goes into lockout.
If the control detects a failure it will now be shown on the
diagnostic indicator light/display. Refer to the Abnormal
Operation section in the Sequence of Operation section of
this manual for more detail on failure codes.
1. Check for 120 volts from Line 1 (Hot) to Line 2 (Neutral)
at the ignition control. No voltage, check the door switch
connections and wire harness for continuity.
2. With the thermostat calling for heat, check for 24 volts
from W to C terminal on the ignition control. No voltage.
Check transformer, room thermostat, and wiring.
If you have 24 volts coming o󰀨 the transformer but
receive approximately 13 volts on the terminal board
between (C) and (R), check for blown fuse.
3. Check for 120 volts to the induced draft blower
(low-stage) by measuring voltage between Pin 3
and Pin 4 (on the 5-pin connector) located on circuit
board. No voltage, check for loose connection
in the 5-pin connector or replace ignition control.
Check for 120 volts to the induced draft blower (high-
stage) by measuring voltage between Pin 2 and Pin 4 (on
the 5-pin connector) located on circuit board. No voltage,
check for loose connection in the 5-pin connector, no call
for high stage heat or replace ignition control.
4. If voltage is present in Steps 1 through 3 and the induced
draft blower is operating, check for 120 volts to the ignitor
during the preheat cycle. Measure voltage between Pin
1 and Pin 5 (on the 5-pin connector) located on ignition
control. No voltage, check low stage and high stage
pressure switches or replace the ignition control board.
background
SERVICING
38
5. After the ignitor warm-up time, begin checking for 24
volts to the gas valve. Voltage will be present for seven
seconds only if proof of ame has been established.
6. If proof of ame was established voltage will be provided
to the air circulation blower following the heat on delay
period.
a. BEFORE replacing the ECM motor assembly or
the end bell, rst check the motor with a Goodman
#UTT-01 UltraCheck-EZTM diagnostic tool. If the
motor runs with the diagnostic tool, the motor is
good. To check the end bell, see the previous
variable speed testing section of this manual before
replacing the end bell.
b. The two-stage variable speed furnaces should have
120 Volts at the motor at all times, even without a
call for cooling or heating. These motors receive their
operational signals through the 4-pin wiring harness,
connected between the motor and integrated control
board.
CHECKING FLAME SENSOR
A ame sensing device is used in conjunction with the
ignition control module to prove combustion. If proof of
ame is not present the control will de-energize the gas
valve and “retry” for ignition or lockout.
WARNING
High Voltage!
Disconnect all power before servicing
or installing this unit. Multiple power
sources may be present. Failure to do
so may cause property damage, personal
injury or death.
1. Disconnect the ame sensor wire from the sensor.
2. Connect a micro-amp meter in series with this wire and
the sensor terminal.
3. Be sure the positive side of the meter is to the ame
sensor wire and the negative side of the meter is to
sensor terminal.
WARNING
Line voltage now present
4. Place the unit into a heating cycle.
5. As soon as ame is established a micro-amp reading
should be evident once proof of flame (micro-amp
reading) is established, the hot surface ignitor will be
de-energized.
6. The Integrated Ignition controls will have 1 to 8 micro-
amps. If the micro-amp reading is less than the minimum
specied, check for high resistance wiring connections,
sensor to burner gap, dirty flame sensor, or poor
grounding.
7. If absolutely no reading, check for continuity on all
components and if good - replace ignition control module.
NOTE: Contaminated fuel or combustion air can
create a nearly invisible coating on the flame
sensor. This coating works as an insulator
causing a loss in the flame sense signal. If
this situation occurs the flame sensor must be
cleaned with steel wool.
background
Name 7-Segment Display Cloud / Phone App
Idle
IdL
Idle
Constant Fan

Constant Fan
Compressor Cooling, Low Stage

Compressor Cooling, Low Stage
Compressor Cooling, High Stage

Compressor Cooling, High Stage
Compressor Heat, Low Stage

Compressor Heat, Low Stage
Compressor Heat, High Stage

Compressor Heat, High Stage
Gas Heat, Low Stage

Gas Heat, Low Stage
Gas Heat, High Stage

Gas Heat, High Stage
Defrost, Low Stage Gas Heat
d
Defrost, Low Stage Gas Heat
Defrost, High Stage Gas Heat
d
Defrost, High Stage Gas Heat
Name
7-Segment Display Cloud / Phone App
Idle
IdL
Idle
Constant Fan

Constant Fan
Compressor Cooling

Compressor Cooling
Compressor Heat

Compressor Heat
Gas Heat, Low Stage

Gas Heat, Low Stage
Gas Heat, High Stage

Gas Heat, High Stage
Defrost, Low Stage Gas Heat
d
Defrost, Low Stage Gas Heat
Defrost, High Stage Gas Heat
d
Defrost, High Stage Gas Heat
Name
7-Segment Display Cloud / Phone App
Idle
IdL
Idle
Constant Fan

Constant Fan
Compressor Cooling, Low Stage

Compressor Cooling, Low Stage
Compressor Cooling, High Stage

Compressor Cooling, High Stage
Compressor Cooling, Single Stage

Compressor Cooling, Single Stage
Compressor Heat, Low Stage

Compressor Heat, Low Stage
Compressor Heat, High Stage

Compressor Heat, High Stage
Compressor Heat, Single Stage

Compressor Heat, Single Stage
Gas Heat, Low Stage

Gas Heat, Low Stage
Gas Heat, High Stage

Gas Heat, High Stage
Defrost, Low Stage Gas Heat
d
Defrost, Low Stage Gas Heat
Defrost, High Stage Gas Heat
d
Defrost, High Stage Gas Heat
Name 7-Segment Display Cloud / Phone App
Humidifier
d
Humidifier
De-Humidifier
d
De-Humidifier
Ventilator
L
Ventilator
Name 7-Segment Display Cloud / Phone App
Special Heat Relay 1

Special Heat Relay 1
Special Heat Relay 2

Special Heat Relay 2
Single-Stage AC, Legacy 2-Stage
Humidifier, De-Humidifier and Ventilator
Special Heat
ClimateTalk Comm Inverter AC/HP
ClimateTalk Comm 2-Stage AC/HP
STATUS CODES
39
background
Name/Cloud/Phone App 7 Segment Display User Modifiable Options Comments
Last 10 Faults
0
N/A Views the control last 10 history faults.
Learn Menu
L
Yes or No. Resets communication network.
Code Release No  N/A Views the control firmware revision number and Shared Data number.
Shared Data Revision  N/A Views the control Shared Data revision number and shared data upload.
Reset To Factory Default d Yes or No. Reset the furnace setting to factory defaults.
Constant Fan Speed d
Adjustable between 25% to + 100% with 10%
ingrements. Default is 25%.
Select the indoor blower airflow at constant fan mode.
Gas Heating Airflow 
Adjustable between Min and Max. Min, Max, Step and
Default are defined in Shared Data.
Select the indoor blower airflow multiplier for gas heat operation.
Gas Heat Off Delay d
Adjustable between 30 seconds to 180 seconds with 5
seconds increments. Default is 30 seconds.
Selects the indoor blower heat off delay.
Gas Heat On Delay d
Adjustable between 5 seconds to 30 seconds with 30
seconds increments. Default is 90 seconds.
Selects the indoor blower heat off delay.
Gas Heat Trim Factor 
Adjustable between -10% to +10% with 2% increments.
Default is 0%.
Trims the heating airflow by the selected amount.
Gas Heat Stage Multiplier 
Adjustable between Min and Max. Min, Max, Step and
Default are defined in Shared Data.
Selects gas heat stage multiplier
Gas Pressure Test  Yes or No. Checks gas valve pressure at 100% firing rate.
Function Enable/Disable Ed Not implemented in the initial
Backup Heat Balance Points 
Adjustable between Min and Max. Min, Max, Step and
Default are defined in Shared Data.
This menu only shows up when a communicating Heat Pump is detected.
Comfort Setting

First 5 option values are defined in Shared Data. The 6th
option shall be hard-coded in the firmware with other 5
settings. The default value is Option 1.
Provides the 6 comfort setting options for the furnace staging algorithm
operation, only shows up when ClimateTalk or DataAC T-Stat is not
connected.
Hum On Enable Ed 1 ~ 16 options and the default option is 15. Provides the 16 humidifier enabling options in different operation modes.
Ventilation On Time 0
Adjustable between 0 ~ 60 minutes. The default is 0
minute Off).
Adjusts the ventilation on time and turn it on/off.
DeHum Logic
dL
Hi and Lo. The default is Lo.
Provides the DeHum logic input level for DeHum operation. Only applies
when the legacy 24VAC input is active.
A2L Function Verification 
Yes or No. Refer to R-32 Section.
A2L Function Enabled E Yes or No. Enables or disables A2L functions. Refer to R-32 section.
Name/Cloud/Phone App 7 Segment Display User Modifiable Options Comments
Tonnage 
Adjustable between 1 to 6 ton with 0.1 increments.
Default is 3 ton.
Only visible when communicating outdoor unit is not detected.
Cool Trim Factor 
Adjustable between -10% to +10% with 2% increments.
Default is 0%.
Trims the cooling airflow by the selected amount.
Cool Airflow Profile  A(1), B(2), C(3), D(4 or 5) Select cooling airflow profiles.
Cool On Delay d
Adjustable between 5 to 30 seconds with 5 seconds
increments. Default is 5 seconds.
Selects the cooling on delay.
Cool Off Delay d
Adjustable between 30 to 120 seconds with 30 seconds
increments. Default is 60 seconds.
Selects the cooling off delay.
Cool Stage Multiplier 
Adjustable between 60% to + 100% with 1% increments.
Default is 70%.
Selects stage multiplier for 2-stage OD unit.
Defrost Gas Heat Stage d 1 or 2 Selects the gas heat stage for defrost operation.
Compressor Balance Points  Adjustable and defined in Shared Data Provides the compressor balance point options for HP operation.
HP Trim Factor 
Adjustable between -10% to +10% with 2% increments.
Default is 0%.
Trims the heating airflow by the selected amount.
HP On Delay
d
Adjustable between 5 to 30 seconds with 5 seconds
increments. Default is 5 seconds.
Selects the HP heating on delay.
HP Off Delay 
Adjustable between 30 to 120 seconds with 30 seconds
increments. Default is 60 seconds.
Selects the HP heating off delay
HP Stage Multiplier 
Adjustable between 70% to 100% with 5% increments.
Default is 70%.
Select stage multiplier for 2-stage OD unit.
Name/Cloud/Phone App 7 Segment Display User Modifiable Options Comments
Cool Trim Factor  -10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10% Trims the cooling airflow by the selected amount.
Cool Airflow Profile

A, B, C, D Select cooling airflow profiles.
Cool On Delay d 5, 10, 20, 30 Selects the cooling on delay.
Furnace
Outdoor AC/HP, Single-Stage AC/HP
ClimateTalk Comm Outdoor 2-Stage AC/HP
MENU OPTIONS
40
background
Name/Cloud/Phone App
7 Segment Display
User Modifiable Options
Comments
Cool Trim Factor 
-10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10%
Trims the cooling airflow by the selected amount.
Cool Airflow Profile 
A, B, C, D
Select cooling airflow profiles.
Cool On Delay d
5, 10, 20, 30 Selects the cooling on delay.
Cool Off Delay d
30, 60, 90, 120 Selects the cooling off delay.
Dehumidifcation Enable
dE
ON, OFF
Enables the dehum function for OD operation.
Defrost Gas Heat Stage d
1 or 2 Selects the gas heat stage for defrost operation.
Compressor Balance Points 
Adjustable and defined in Shared Data Selects the compressor balance point options for HP operation.
HP Trim Factor 
-10%, -8%,-6%, -4%, -2%, 0%, 2%, 4%, 6%, 8%,10% Trims the heating airflow by the selcted amount
HP On Delay
d
5, 10, 15
Selects the HP heating on delay.
HP Off Delay d
30, 50, 70, 90
Selects the HP heating off delay.
HP Defrost Interval dI
30, 60, 90, 120 Provides the defrost options for compressor heating operation.
Compressor Delay
dL
0, 5, 15, 30
Provides the compressor delay options for heating operation.
History Fault and Clear L
Yes or No.
Views the comm outdoor history and clear the outdoor unit
history fault.
Name/Cloud/Phone App
7 Segment Display
User Modifiable Options
Comments
Boost Mode 
On or Off Provides the options for inverter boot operation.
Boost Temp 
On(Always), 70F, 75F, 80F, 85F, 90F, 95F, 100F, 105F Provides the 9 temperature options for boot operation.
Set Max Current

OFF, 40%, 50%, 60%, 70%, 80%, 90%
Selects Max Current options
Vertical Rise

SL (Same Level), OL (Outdoor Lower), IL (Indoor
Lower)
Selects the level of outdoor vas indoor equipment.
System Reset Menu 
Yes or No. Reset all outdoor unit settings to factory default.
System Verification Test
On or Off Runs System Verification Test after Installation.
Pump Down
d
On or Off
Enters Pump Down mode.
Charge Mode

On or Off
Enters charge mode.
Cool-Trim Factor - High 
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the cooling airflow by the selected amount.
Cool-Trim Factor - Intermediate I
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the cooling airflow by the selected amount.
Cool-Trim Factor - Low L
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the cooling airflow by the selected amount.
Cool Airflow Profile

A, B, C, D Select cooling airflow profiles.
Cool On Delay d
5, 10, 20, 30 Selects the cooling on delay.
Cool Off Delay d
30, 60, 90, 120 Selects the cooling off delay.
Dehum Enable dE
On or Off Enables the dehum function for compressor operation.
Cool Reset Menu L
Yes or No. Resets all cooling settings to factory default.
Cool Max RPS Range

01(58 to 62.5 RPS), 02(63 to 67.5 RPS), 03(68RPS),
04(68.5 to 73 RPS), 05(73.5 to 78 RPS)
Selects the appropriate range for the installed system
configuration.
Cool Max RPS Selection 
10 RPS values from inverter
Selects the appropriate compressor RPS for the installed system
configuration.
Defrost Gas Heat Stage d
1 or 2 Selects the gas heat stage for defrost operation.
Compressor Balance Points

Adjustable and defined in Shared Data Provides the compressor balance point options for HP operation.
Force Defrost dd
On or Off
HP Trim Factor - High 
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the heating airflow by the selected amount.
HP Trim Factor - Intermediate I
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the heating airflow by the selected amount.
HP Trim Factor - Low L
-15, -12, -9, -6, -3, 0, 3, 6, 9, 12, 15 Trims the heating airflow by the selected amount.
HP On Delay
d
5, 10, 20, 30 Selects the HP heating on delay.
HP Off Delay d
30, 60, 90, 120 Selects the HP heating on delay.
HP Defrost Interval dI
Maximum amount of compressor runtime before
defrost occurs.
Provides the defrost options for compressor heating operation.
HP Reset Menu 
Yes or No. Resets all heating settings to factory default.
HP Max RPS Range 
01(58 to 62.5 RPS), 02(63 to 67.5 RPS), 03(68RPS),
04(68.5 to 73 RPS), 05(73.5 to 78 RPS)
Selects the appropriate range for the installed system
configuration.
HP Max RPS Selection 
10 RPS values from inverter
Selects the appropriate compressor RPS for the installed system
configuration.
History Fault and Clear L
Yes or No.
Views the comm outdoor history and clear the outdoor unit
history fault.
ClimateTalk Comm Outdoor 2-Stage AC/HP
ClimateTalk Comm Outdoor Inverter AC/HP
MENU OPTIONS
41
background
Symptom LED Status Fault Description Possible Causes Corrective Action(s) Notes & Cautions
Normal operation. IdL Idle • Normal operation. • None • Normal operation.
Furnace fails to
operate.
Integrated control
module LED display
provides no signal.
nonE No 115v power to
furnace or no 24 volt
power to integrated
control module.
Blown fuse or tripped
circuit breaker.
Integrated control mod-
ule is non-functional.
• Manual disconnect
switch turned OFF,
door switch open or
24 volt wire improperly
connected or loose.
• Furnace electrical sup-
ply shared with other
devices.
• Integrated control mod-
ule is non-functional.
• Check 115 volt power to
furnace and integrated
control module.
• Check for possible shorts
in 115 volt circuit. Repair
as necessary.
• Replace non-functional
integrated control module.
• Turn power OFF prior
to repair
• Read precautions
in ""Electrostatic
Discharge"" section of
manual.
• Replace control with
correct replacement
part.
Furnace fails to
operate.
Eb0 Circulator blower motor
not running when it
should be running.
• Loose wiring connec-
tion at circulator motor
power leads or circula-
tor motor power leads
disconnected.
• Failed circulator blower
motor.
• Tighten or correct wiring
connection.
• Check circulator blower
motor. Replace if neces-
sary.
• Turn power OFF prior
to repair.
• Replace circulator
motor with correct
replacement part.
Furnace fails to
operate.
Eb1 Integrated control mod-
ule has lost communi-
cations with circulator
blower motor.
• Loose wiring connec-
tion at circulator motor
power leads,
• Failed circulator blower
motor.
• Failed integrated con-
trol module.
• Tighten or correct wiring
connection.
• Check circulator blower
motor. Replace if neces-
sary.
• Check integrated control
module. Replace if nec-
essary.
• Turn power OFF prior
to repair.
• Replace circulator
motor with correct
replacement part.
• Replace integrated
control module with
correct replacement
part.
Furnace fails to
operate.
Eb2 Circulator blower motor
horse power in shared
data set does not match
circulator blower motor
horse power.
• Incorrect circulator
blower motor in fur-
nace.
• Incorrect shared data
det in integrated con-
trol module.
• Verify circulator blower if
motor horsepower is the
same specied for the
specic model. Replace if
necessary.
• Verify shared data set is
correct for the specic
model. Re-populate data
using the CoolCloud HVAC
App if required.
• Turn power OFF prior
to repair
• Replace circulator
motor with correct
replacement part
• Error code will be
cleared once shared
data and motor horse-
power match.
Furnace operates at
reduced perfor-
mance.
Airow delivered is
less than expected.
Eb3 Circulator blower motor
is operating in a power,
temperature or speed
limiting condition.
• Blocked lters.
• Restrictive ductwork.
• Undersized ductwork.
• High ambient tempera-
tures.
• Check lters for blockage.
Clean lters or remove
obstruction.
• Check ductwork for block-
age. Remove obstruction.
Verify all registers are fully
open.
• Verify ductwork is appro-
priately sized for system.
Resize/replace ductwork if
necessary.
• See ""III. Product Descrip-
tion"" and ""IV Location
Requirements & Con-
siderations"" for furnace
installation requirements.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
Eb4 Circulator blower motor
senses a loss of rotor
control.
Circulator blower motor
senses high current.
• Abnormal motor load-
ing, sudden change
in speed or torque,
sudden blockage of
furnace air inlet/outlet.
• Check lters, lter grilles,
registers, duct system and
furnace air inlet/outlet for
blockages.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
Eb5 Circulator blower motor
fails to start 10 consec-
utive times.
• Obstruction in circula-
tor blower housing.
• Seized circulator blow-
er motor bearings.
• Failed circulator blower
motor.
• Check circulator blower for
obstructions. Remove and
repair/replace wheel or
motor if necessary.
• Turn power OFF prior
to repair.
• Replace motor with
correct replacement
part.
• Replace wheel with
correct replacement
part.
TROUBLESHOOTING
42
background
Symptom LED Status Fault Description Possible Causes Corrective Action(s) Notes & Cautions
Furnace fails to
operate.
Eb6 Circulator blower motor
shuts down due to
over or under voltage
condition.
Circulator blower motor
shuts down due to over
temperature condition
on power module.
• High AC line voltage to
furnace.
• Low AC line voltage to
furnace.
• High ambient tempera-
tures.
• Check power to furnace.
Verify line voltage to
furnace is within the range
specied on the furnace
rating plate.
See ""III. Product Descrip-
tion"" and ""IV Location
Requirements & Con-
siderations"" for furnace
installation requirements.
• Turn power OFF prior
to repair.
• Replace motor with
correct replacement
part.
• Re-populate data using
the CoolCloudHVAC
App if required.
Furnace fails to
operate.
Eb7 Circulator blower motor
does not have enough
information to operate
properly.
Motor fails to start 40
consecutive times.
• Error with integrated
control module.
• Motor has a rotor
condition.
• Check integrated control
module. Verify control is
populated with correct
shared data set. See data
errors above for details.
• Check for locked rotor
condition.
• Turn power OFF prior
to repair.
Furnace operates at
reduced perfor-
mance or operates
on low stage when
high stage is ex-
pected.
Eb9 Airow is lower than
demanded.
• Blocked lters.
• Restrictive ductwork.
• Undersized ductwork.
• High ambient tempera-
tures.
• Check lters for blockage.
Clean lters or remove
obstruction.
• Check ductwork for block-
age. Remove obstruction.
Verify all registers are fully
open.
• Verify ductwork is appro-
priately sized for system.
Resize/replace ductwork if
necessary.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
Ed0 Data not yet on net-
work.
• No network Data • Populate shared data set
using the CoolCloudHVAC
App.
• Turn power OFF prior
to repair.
• Use the CoolCloudH-
VAC App to download
the shared data set to
the furnace.
• Error code will be
cleared once data is
downloaded from the
CoolCloudHVAC App.
Operation di󰀨erent
than expected or no
operation.
Ed1 Invalid shared data. • Shared data set is
invalid. Use the Cool-
CloudHVAC App to
download the shared
data to the furnace.
• Verify shared data set
is correct for the specif-
ic model. Re-populate
shared data set using the
CoolCloudHVAC App.
• Turn power OFF prior
to repair.
• Error code will be
cleared once data is
downloaded from the
CoolCloudHVAC App.
Furnace fails to
operate.
EE0 Furnace lockout due
to excessive number
of ignition ""retries"" (3
total).
Failure to establish
ame.
Loss of ame after
establishment.
• Failure to establish
ame. Cause may be
no gas to burners, front
cover pressure switch
stuck open, bad igniter
or igniter alignment,
improper orices, or
coated/oxidized or
improperly connected
ame sensor.
• Loss of ame after
establshment. Cause
may be interrupted
gas supply, lazy burner
ames (improper gas
pressure or restriction
in ue and/or lack of
combustion air), or
improper induced draft
blower performance.
• Locate and correct gas
interruption.
• Replace or realign igniter.
• Check ame sense signal.
Clean sensor if coated
and/or oxidized.
• Check ue piping for block-
age, proper length, elbows
and termination.
• Verify proper induced draft
blower performance.
• Turn power OFF prior
to repair.
• Igniter is fragile, handle
with care.
• Clean ame sensor
with steel wool.
• See ""Vent/Flue Pipe""
section for piping
details.
Furnace fails to
operate.
EE1 Low-stage pressure
switch circuit closed at
start of heating cycle.
• Low stage pressure
switch contacts stick-
ing.
• Short in pressure
switch circuit wiring.
• Replace low stage pres-
sure switch.
• Repair short in wiring.
• Turn power OFF prior
to repair.
• Replace pressure
switch with proper
replacement part.
TROUBLESHOOTING
43
background
Symptom LED Status Fault Description Possible Causes Corrective Action(s) Notes & Cautions
Induced draft blower
runs continuously
with no further fur-
nace operation.
EE2 Low-stage pressure
switch circuit open.
• Pressure switch hose
blocked, pinched, or
connected improperly.
• Blocked ue pipe, or
weak induced draft
blower.
• Incorrect pressure
switch set point or
malfunctioning switch
contacts.
• Loose or improperly
connected wiring.
• Inspect pressure switch
hose. Repair/replace if
necessary.
• Inspect ue piping for
blockage, proper length,
elbows and termination.
Correct as necessary.
• Correct pressure switch
set point or contact motion.
• Tighten or correct wiring
connections.
• Turn power OFF prior
to repair.
• Replace pressure
switch with proper
replacement part.
• Replace induced draft
blower with proper
replacement part.
Circulator blower
runs continuously
with no furnace
operation.
EE3 Primary limit circuit
open.
• Insu󰀩cient conditioned
air over the heat ex-
changer.
• Blocked lters, restric-
tive ductwork.
• Inproper circulator
blower speed or failed
circulator blower motor.
• Loose or improperly
connected wiring in
high limit circuit.
• Check lters and ductwork
for blockage. Clean lters
or remove obstruction.
• Check circulator blower
speed and performance.
Correct speed or replace
blower motor if necessary.
• Tighten or correct wiring
connections.
• Turn power OFF prior
to repair.
• See Specication
Sheet applicable for
your model for allow-
able temp rise range
and proper circulator
speed.
Induced draft blower
and circulator blow-
er run continuously
with no furnace
operation.
EE4 Flame sensed with no
call for heat.
• Short to ground in
ame sense circuit.
• Lingering burner ame.
• Slow closing gas valve.
• Correct short at ame
sensor or in ame sensor
wiring.
• Check for lingering ame.
• Verify proper operation of
gas valve.
• Turn power OFF prior
to repair.
No furnace oper-
ation.
EE5 Open fuse. • Short in low voltage
wiring
• Back of control board
is touching mounting
panel because stand-
o󰀨s are missing.
• Locate and correct short in
low voltage wiring.
• Replace the missing
stando󰀨s.
• Turn power OFF prior
to repair.
• Replace fuse with
3-amp automotive
type.
Normal furnace
operation with weak
ame signal.
EE6 Flame sense micro amp
signal is low.
• Flame sensor is coat-
ed/oxidized.
• Flame sensor incor-
rectly positioned in
burner ame.
• Lazy burner ame due
to improper gas pres-
sure or combution air.
• Clean ame sensor if
coated or oxidized.
• Inspect ame sensor for
proper alignment.
• Compare current gas pres-
sure to rating plate and
adjust as needed.
• Turn power OFF prior
to repair.
• Clean ame sensor
with steel wool.
• See ""Vent/Flue Pipe""
section for piping
details.
• See rating plate for
proper gas pressure.
Furnace fails to
operate.
EE7 Problem with igniter
circuit.
• Improperly connected
igniter.
• Shorted igniter.
• Poor furnace ground.
• Igniter relay fault on
integrated control
module.
• Check and correct wiring
from integrated control
module to igniter.
• Replace shorted igniter.
• Check and correct furnace
ground wiring.
• Check igniter output from
control. Replace if neces-
sary.
• Turn power OFF prior
to repair.
• Replace igniter with
correct replacement
part.
• Replace control with
correct replacement
part.
Furnace fails to op-
erate on high stage.
Furnace operates
normally on low
stage.
EE8 High-stage pressure
switch circuit closed at
start of heating cycle.
• High stage pressure
switch contacts stick-
ing.
• Short in pressure
switch circuit wiring.
• Replace high stage pres-
sure switch.
• Repair short in wiring.
• Turn power OFF prior
to repair.
• Replace pressure
switch with proper
replacement part.
Furnace fails to op-
erate on high stage.
Furnace operates
normally on low
stage.
EE9 High-stage pressure
switch circuit open.
• Pressure switch hose
blocked, pinched, or
connected improperly.
• Blocked ue pipe, or
weak induced draft
blower.
• Incorrect pressure
switch set point or
malfunctioning switch
contacts.
• Loose or improperly
connected wiring.
• Inspect pressure switch
hose. Repair/replace if
necessary.
• Inspect ue piping for
blockage, proper length,
elbows and termination.
Correct as necessary.
• Check induced draft blow-
er performance. Correct as
necessary.
• Correct pressure switch
set point or contact motion.
• Tighten or correct wiring
connections.
• Turn power OFF prior
to repair.
• Replace pressure
switch with proper
replacement part
• Replace induced draft
blower with proper
replacement part.
TROUBLESHOOTING
44
background
Symptom LED Status Fault Description Possible Causes Corrective Action(s) Notes & Cautions
Furnace fails to
operate.
E10 Grounding fault • Poor neutral connec-
tion.
• Verify neutral wire connec-
tion to furnace and conti-
nuity to ground source.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
E11 Open rollout switch. • Gas pressure too high.
• Burners mis-aligned.
• Restricted heat ex-
changer or venting.
• Check and correct gas
pressure.
• Check and correct burner
alignment.
• Check and correct restric-
tion
• Turn power OFF prior
to repair.
External return air
temperature reading
not visible on Cool-
Cloud app
E15 Return Air Temperature
Sensor Circuit is Open
(External)
NOTE: Allow time as the control
may take up to 90 seconds to
detect sensor.
• Verify that the sensor
probe is plugged in all the
way
• Verify that the sensor
probe connector is proper-
ly crimped.
• Verify that resistance
across the sensor probe is
10kΩ at 77°F. Resistance
is lower at temperatures
higher than 77°F. Resis-
tance is higher at tempera-
tures lower than 77°F.
• Replace PCB
• Turn power OFF prior
to repair.
External return air
temperature reading
not visible on Cool-
Cloud app
E16 Return Air Temperature
Sensor Circuit is Short-
ed (External)
• Check sensor probe
terminals & conductors for
electrical short.
• Check PCB connector for
shorts if sensor short error
reported when sensor
probe is not plugged in.
• Replace PCB
• Turn power OFF prior
to repair.
Supply air tempera-
ture reading not
visible on CoolCloud
app
E17 Supply Air Temperature
Sensor Circuit is Open
(External)
NOTE: Allow time as the control
may take up to 90 seconds to
detect sensors.
• Verify that the sensor
probe is plugged in all the
way
• Verify that the sensor
probe connector is proper-
ly crimped.
• Verify that resistance
across the sensor probe is
10kΩ at 77°F. Resistance
is lower at temperatures
higher than 77°F. Resis-
tance is higher at tempera-
tures lower than 77°F.
• Replace PCB
• Turn power OFF prior
to repair.
Supply air tempera-
ture reading not
visible on CoolCloud
app
E18 Supply Air Temperature
Sensor Circuit is Short-
ed (External)
• Check sensor probe
terminals & conductors for
electrical short.
• Check PCB connector for
shorts if sensor short error
reported when sensor
probe is not plugged in.
• Replace PCB
• Turn power OFF prior
to repair.
Onboard return air
temperature reading
not visible on Cool-
Cloud app
E19 Onboard return air
temperature sensor is
unplugged
• Power cycle the furnace,
the control may take up
to 90 seconds to detect
sensors
• Check PCB for any visible
electrical or mechanical
damage to onboard sensor
(R311).
• Replace PCB
• Turn power OFF prior
to repair.
TROUBLESHOOTING
45
background
Symptom LED Status Fault Description Possible Causes Corrective Action(s) Notes & Cautions
Onboard return air
temperature reading
not visible on Cool-
Cloud app
E1A Onboard return air
temperature sensor is
shorted.
• Power cycle the furnace,
the control may take up
to 90 seconds to detect
sensors
• Ensure there are no
foreign objects on the
PCB that could cause an
electrical short at onboard
sensor (R311).
• Replace PCB
• Turn power OFF prior
to repair.
Furnace fails to
operate.
EEA Polarity if 115 volt AC is
reversed.
• Polarity of 115 volt
AC power to furnace
or integrated control
module is reversed.
• Poor furnace ground.
• Review wiring diagram to
correct polarity.
• Verify proper ground.
Correct if necessary.
• Check and correct wiring.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
EEb Gas valve is not ener-
gized when it should be.
External gas valve error.
• Miswired gas valve
circuit.
• Open gas valve circuit.
• Gas valve relay on in-
tegrated control board
stuck open.
• Check wiring in gas valve
circuit.
• Replace integrated control
board.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
EEC Gas valve is energized
when it should not be.
Internal gas valve error.
• Miswired gas valve
circuit.
• Shorted gas valve
wiring.
• Gas valve relay on in-
tegrated control board
stuck open.
• Check wiring in gas valve
circuit.
• Replace integrated control
board.
• Turn power OFF prior
to repair.
Furnace fails to
operate.
EEd Aux limit switch open
(blower compartment).
• 115 volt power supply
was shut o󰀨 during
heat cycle.
• Insu󰀩cient conditioned
air over the heat
exchanger. Blocked
lters, restrictive
ductwork, improper
circulator blower speed
or failed circulator
blower motor.
• Check lters and ductwork
for blockage. Clean lters
or remove obstruction.
• Check circulator blower
speed and performance.
Correct speed or replace
blower motor if necessary.
• Tighten or correct wiring
connections.
• Turn power OFF prior
to repair.
• See Specication
Sheet applicable for
your model for allow-
able temp rise range
and proper circulator
speed.
Furnace fails to
operate.
EEF AUX switch (conden-
sate switch) open.
• High water level in
evaporator coil drain
pan or auxiliary drain
pan
• Check evaporator coil
drain pan, piping and auxil-
iary drain pan.
• Turn power OFF prior
to repair.
Furnace stops heat-
ing and only the fan
is operating.
EAF Furnace has lost
communication with the
R-32 sensor and the
furnace is in mitigation
mode.
Furnace may not be paired
with R-32 Cooling Unit. Re-
fer to the R-32 Information
Section.
• Verify wire connection to
R-32 sensor is not loose.
• Verify the R-32 sensor wire
is not damaged.
• Replace R-32 sensor if
necessary.
• Turn power OFF prior
to repair.
• Replace R-32 sensor
with proper replace-
ment part.
Furnace stops heat-
ing and only the fan
is operating.
EA0 R-32 sensor has
detected a refrigerant
leak and furnace is in
mitigation mode.
• Investigate the indoor coil
for a refrigerant leak.
• Furnace will resume
normal operation once a
leak is not detected and
the 5 minute delay period
is over.
• Turn power OFF prior
to repair.
Furnace stops heat-
ing and only the fan
is operating.
EA1 R-32 sensor has detect-
ed a fault and furnace is
in mitigation mode.
• Investigate the R-32
sensor.
• Replace the R-32 sensor if
necessary.
• Turn power OFF prior
to repair.
• Replace R-32 sensor
with proper replace-
ment part.
Furnace stops heat-
ing and only the fan
is operating.
EA2 A2L relay in the furnace
control board has
detected a fault and
furnace is in mitigation
mode.
• Investigate the A2L relay.
• Cycle power to the fur-
nace.
• Replace the integrated
control board if necessary.
• Turn power OFF prior
to repair.
• Replace the integrat-
ed control board with
proper replacement
part.
TROUBLESHOOTING
46
background
47
Troubleshooting ComfortBridge - 80%
No Heat
Yes
No
No
Yes
No
Does furnace
triple 7 segment
display show IdL
Verify 24v from W to C
Is thermostat calling
for heat and furnace
LED display show
gH1 or gH2
Check wiring harness between
board & draft inducer, if wiring
ok, replace board
Is inducer
motor running
Replace draft inducer
No
Replace PS
Yes
Is low fire
PS closed
No
Does igniter
warm up at all
Yes
Replace igniter
Igniter relay on control board is
faulty, replace board
Yes
Does igniter stay
on for 17 second
warm up
Yes
Does gas valve open
verified by low fire manifold
pressure of 2” wc for nat
gas, 6” wc for LP gas, turn
low & high fire adjustment
screws to the bottom
No
Low fire pressure switch is not
staying closed
Correct gas supply pressure
problem
Yes
Replace gas valve
Igniter
resistance 37-68
ohms at room
temperature
Yes
No
Check furnace breaker, switch, door
switch, 115 VAC at Line H & Line N on
control board, 115 VAC at transformer
primary, 24 VAC at transformer
secondary
If all check ok replace control
board
No
Is draft inducermotor
getting 115 vac between
black-white from control
board for pre purge
Yes
No
Is negative
pressure
enough to
close fire PS
Yes
Check for vent obstruction or
excessive vent length / elbows
No
Is gas supply pressure
verified to furnace. During
trial for ignition supply
pressure must be 5-10” wc
for Nat gas and 11-13” wc
for LP gas
Yes
No
Do burners
fire up?
Check for correct orifice size,
check for dirty burners, check
burner alignment, check for
orifice plate between to burners
and H/E out of position
No
Yes
Do burners stay
on more than 4
seconds
Check for flame signal of 1-2
microamps, check furnace and
control board earth ground
No
Yes
No
Does blower
motor come on
following 30
second delay
Check for fault code displayed
and make corrective action
based on fault code. Use
UTT-01 to diagnose motor
Yes
Does actual temp rise
fall within the range
specified on furnace
rating plate
Yes
No
Correct condition causing rise
to be out of range
background
48
Troubleshooting ComfortBridge - 80%
Yes
Completed
Does actual temp rise
fall within the range
specified on furnace
rating plate
Yes
Does burner stay
on to satisfy
thermostat
Yes
Check for vent restriction not
allowing high fire switch to close
Check for fault code displayed
No
No
Correct condition causing rise
to be out of range
Adjust thermostate to call for 2nd
stage or use gPt menu, gH2 on
furnace LED display
Does manifold
pressure go up to
3.5” wc Nat gas, 10”
wc for LP gas
No
Yes
background
49
Troubleshooting Error Codes - (B0 & B1)
Board flashes
B0 & B1
No
Yes
Check wiring
harnesses and wiring
connections.
Correct loose wiring
issue.
Ohm motor for open
or shorted circuit. Is
motor open or
shorted?
Test control voltage at the
control board. Replace
integrated control board if
necessary.
Test ECM motor and controller
with ECM tester. Replace motor
and/or controller if necessary
Replace motor if open or
shorted.
Correct power supply if out of
range. Replace motor if
necessary
Check for primary
voltage to blower motor.
Is the power supply
voltage between 104 &
127 vAC (115vAC +
10%)? (Typically
115-127vAC)
Yes
Check control
voltage between
pins 1 & 4. Voltage
should be between
3-15 vDC (Typically
9-15 vDC)
Yes
No
No
Error Code:
B0 - Circulator blower motor not
running when it should be running.
B1 - Integrated control module has
lost communications with
circulator blower motor.
Applicable Models:
(for Goodman Amana Brand)
*RVS-U, *DVT, *RVT, *DVM,
*RVM
(for Daikin)
DR**SC-U, DD**TC, DR**TC,
DD97MC, DR97MC
Method of Error Detection:
B0 - High voltage to the motor,
no DC voltage to the motor or no
communication to blower motor.
B1 - Bad ground or no
communication to blower motor.
Error Decision Conditions:
Primary voltage to blower motor
out of range.
Missing DC voltage between pins
1 and 4.
background
50
Troubleshooting Error Code - (B2-B6, B9)
Board flashes
B2,B3,B4,B5,B6, or B9
No
Yes
Does the
furnace have the
correct blower
motor?
Verify shared data set is correct
for specific model. Repopulate
shared data if required
Correct power supply if out of
range
Replace motor if necessary.
Verify correct motor horsepower.
Replace if necessary
Check for blocked
filters, restrictive
ductwork, undersized
ductwork. Does the
furnace have any of
these conditions?
Yes
Is the furnace
operating in a high
ambient condition
outside of the
temperature range
specified?
Yes
No
No
Does the
furnace have
the correct
shared data?
Check primary
voltage to blower
motor. Is the power
supply voltage
between 104 & 127
vAC (115vAC
+10%)?
Address high ambient condition
if necessary.
Check filters, remove
obstructions, verify registers are
fully open and RA grills are not
blocked. Verify duckwork is
appropriately sized. Resize/
replace ductwork if necessary.
No
No
Yes
Yes
Error Code:
B2 - Circulator blower motor HP in
shared data set does not match
circulator blower motor HP.
B3 - Circulator blower motor is
operating in a power, temperature
or speed limiting condition.
B4 - Circulator blower motor
senses a loss of rotor control or
high current.
B5 - Circulator blower motor fails
to start 10 consecutive times.
B6 - Circulator blower motor shuts
down due to over or under voltage
condition, or over temperature
condition.
B9 - Airflow is lower than
demanded.
Applicable Models:
(for Goodman/Amana Brand)
*RVS80-U, *RVS96-U, *DVT,
*RVT, *DVM97, *RVM97
(for Daikin)
DR**SC-U
Method of Error Detection:
Wrong horsepower blower motor,
primary voltage to motor is out of
range, high temperature, high amp
draw blower motor failure.
Error Decision Conditions:
Wrong horsepower blower motor,
primary voltage to motor is out of
range, high temperature, high amp
draw blower motor failure.
background
51
Troubleshooting Error Codes - (E0 - 80%)
Board flashes
E0
No
Yes
Are burners
firing up?
Check gas valve On/Off switch
is turned to On position and 24V
present at gas valve? Check
wire harness connection on gas
valve.
Check flame sense signal.
Clean flame sensor if coated
and/or oxidized.
Check manifold gas pressure is
remaining constant and not
dropping below required range
Verify 115VAC present at ignitor.
Replace if voltage is present
Is hot surface
ignitor
glowing?
Yes
Is supply gas present
and manifold gas
pressure within
range. (Nat. Gas 3.2"
to 3.8" W.C, LP 9.7" -
10.3" W.C)
Yes
No
No
Error Code:
E0 - Lockout due to an excessive
number of ignition retries (3 total)
Applicable Models:
All 80% models
Method of Error Detection:
Furnace fails to ignite after 3
retires
Error Decision Conditions:
No gas or low gas pressure at
manifold. Bad hot surface ignitor -
not glowing, dirty flame sensor
Are burners
staying lit?
Yes
No
Verify low fire pressure switch is
remaining close. Replace if
needed
background
52
Troubleshooting Error Codes - (E3)
Board flashes E3
No
Yes
Check for blocked
filters, restrictive
ductwork, undersized
ductwork. Does the
furnace have any of
these conditions?
Correct blower speed to
maintain temperature rise within
the specifications.
Correct any wiring issues
Correct power supply if out of
range
Replace blower motor or
controller as needed.
Check primary voltage
to blower motor. Is the
power supply voltage
between 104 and 127
vAC (115vAC + 10%)?
Is the circulator
blower speed set
to the correct
speed for heating
airflow
No
No
Does the blower motor
have any loose or
improperly connected
wiring in the primary
limit circuit or to the
blower motor from the
control board?
Replace primary limit
Clean filters, remove
obstructions, verify registers are
fully open and RA grills are not
blocked. Verify ductwork is
appropriately sized. Resize/
replace ductwork if necessary.
No
Yes
Yes
Error Code:
E3 - Primary limit circuit is open.
Applicable Models:
All furnace models
Method of Error Detection:
Temperature across primary limit
during heating operation.
Error Decision Conditions:
During heating operation, primary
limit break temperature has
opened the primary limit circuit.
Is the primary
limit stuck open
or shorted?
No
Yes
No
No
Yes
Check the
performace of the
blower motor. Is
the blower motor
operating
properly?
Yes
Check gas inlet
and manifold
pressure. Are both
of these withing
specifications?
Yes
Adjust inlet and/or manifold
pressure to specification.
Perform combustion analysis to
determine other possible issues.
background
53
Troubleshooting Fault Codes - (E4 & E6)
Board flashes
E4 or E6
No
Does the furnace
have an actual
ground wire from
the furnace to the
breaker panel
ground bar?
Correct short at flame sensor or
in flame sensor wiring.
Check for lingering flame. Verify
proper operation of gas valve.
Yes
Correct furnace wiring - install
ground wire to breaker
Does the furnace
have a lingering
burner flame or a
slow closing gas
valve?
Yes
Check flame
sense micro
amp signal. Is
the micro amp
reading 1 or
lower?
Yes
No
No
Check flame sense
circuit to ground. Does
flame sense circuit
have a short to
ground?
No
Yes
Clean flame sensor with steel
wool (never use sand paper). If
flame sensor rod is pitted or
damaged - replace as needed.
Inspect for proper flame sensor
alignment.
Check gas inlet and manifold
pressures to rating plate and
adjust as needed.
If flame sense micro amp signal
to control board is more than 1
(typical range of 2 to 4), replace
control board as needed.
Error Code:
E4 - Flame sensed with no call for
heat.
E6 - Flame sense micro amp
signal is minimal.
Applicable Models:
All furnace models
Method of Error Detection:
Micro amp signal from flame
sensor.
Error Decision Conditions:
Micro amp reading with no call for
heat.
Low micro amp reading after
furnace ignition.
background
54
Troubleshooting Error Code - (Eb & EC)
Board flashes
Eb or EC
No
Check gas valve
wiring circuit. Is
wiring to gas valve
correct?
Integrated
control board
stuck closed.
Replace
integrated
control board.
Remove wiring connections
to the gas valve and check
for voltage at these
connections. If voltage is
present, check gas valve for
short to ground or loose
connection. Repair loose
connection or replace gas
valve as needed.
Verify voltage to gas valve is
the same as transformer
voltage. If voltage is not the
same, check for grounding
issue, If voltage is the same,
replace gas valve as needed.
Yes
Correct miswiring to gas
valve.
Yes
Yes
No
No
Is gas valve
shorted?
Yes
With no call for
heat, do you
have voltage to
gas valve?
With a call for heat and
the igniter on, do you
have voltage between
M & Common on the
gas valve?
No
Using the
wiring
diagram,
locate the MV
(MVL) and
Common
wires in the
wiring harness
connection on
the integrated
control board.
With a call for heat
and the igniter on,
do you have
voltage between
these 2 pins?
Integrated control board
stuck closed. Replace
integrated control board.
Replace gas valve as
needed.
Error Code:
Eb - Gas valve is not energized
when it should be. External Gas
Valve Error.
EC - Gas valve is energized when
it should not be. Internal Gas
Valve Error.
Applicable Models:
(for Goodman/Amana Brand)
All furnace models
(for Daikin)
All furnace models, except Daikin
modulating furnaces
Method of Error Detection:
No voltage to gas valve when
voltage should be present.
Voltage to gas valve with no call
for heat.
Error Decision Conditions:
No voltage reading at gas valve
with a call for heat.
Voltage reading at gas valve with
no call for heat.
Remove wires on
gas valve and check
gas valve for
shorted to ground.
No
Yes
background
AIRFLOW DATA
MODEL/TEMP RISE RANGE
(MID RISE)
GRVT800803B*A*
30-60 (45)
GRVT800804C*A*
25-55 (40)
GRVT800805C*A*
20-50 (35)
GRVT800805D*A*
20-50 (35)
GRVT801005C*A*
25-55 (40)
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
Recommended cfm for high heat /
expected temperature rise
1330 45 1400 42 1700 35 1700 35 1850 40
Lowest recommended cfm for hi heat /
expected temperature rise
980 60 1090 54 1175 50 1175 50 1350 55
NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5% 0140F02402-A
MODEL/TEMP RISE RANGE
(MID RISE)
GDVT800603BXA*
25-55 (40)
GDVT800803BXA*
30-60 (45)
GDVT800805CXA*
25-55 (40)
GDVT801005CXA*
20-50 (35)
GRVT800603B*A*
15-45 (30)
GRVT800604B*A*
25-50 (35)
CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE CFM RISE
Recommended cfm for high heat /
expected temperature rise
1100 40 1325 45 1470 40 2090 35 1400 32 1275 35
Lowest recommended cfm for hi heat /
expected temperature rise
810 55 990 60 1070 55 1475 50 980 45 890 50
NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5% 0140F02402-A
GRVT800603B*A*, GRVT800803B*A*
GDVT800603BXA*, GDVT800803BXA*
COOLING SPEED
(@ 0.1” - 0.8” w.c. ESP)
GRVT800604B*A*
GRVT800804C*A*
COOLING SPEED
(@ 0.1” - 0.8” w.c. ESP)
Tons
HIGH-STAGE
CFM
Low-Stage
CFM
Tons
HIGH-STAGE
CFM
Low-Stage
CFM
1.5 600 420 2 800 560
2 800 560 2.5 1,000 700
2.5 1,000 700 3 1,200 840
3 1,200 840 4 1,600 1,120
MAX 1,400 MAX 1,760
GDVT800805CXA*
GDVT801005CXA*
COOLING SPEED (@ 0.1” - 0.8” w.c. ESP)
GRVT800805C*A*, GRVT800805D*A*
GRVT801005C*A*
COOLING SPEED
(@ 0.1” - 0.8” w.c. ESP)
Tons
HIGH-STAGE
CFM
Low-Stage
CFM
Tons
HIGH-STAGE
CFM
Low-Stage
CFM
2 800 560 2 800 560
3 1,200 840 3 1,200 840
4 1,600 1,120 4 1,600 1,120
5 2,000 1,400 5 2,000 1,400
MAX 2,000 MAX 2,200
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
55
background
WIRING DIAGRAM
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
56
A/GRVT80*AA
TONNAGE MENU
TONNAGE
SELECTION
AIR
FLOW
TONNAGE
SELECTION
AIR
FLOW
1.0 400 3.6 1440
1.1 440 3.7 1480
1.2 480 3.8 1520
1.3 520 3.9 1560
1.4560 4.0 1600
1.5600 4.1 1640
1.6640 4.2 1680
1.7680 4.3 1720
1.8720 4.4 1760
1.9 760 4.5 1800
2.0 800 4.6 1840
2.1 840 4.7 1880
2.2 880 4.8 1920
2.3 920 4.9 1960
2.4960 5.0 2000
2.5 10005.1 2040
2.6 10405.2 2080
2.7 10805.3 2120
2.8 11205.4 2160
2.9 11605.5 2200
3.0 12005.6 2240
3.1 12405.7 2280
3.2 12805.8 2320
3.3 13205.9 2360
3.4 13606.0 2400
3.5 1400
MAXIMUM AIRFLOW OUTPUT
• 3 TON 60k BTUH = 1,400 CFM
• 3 TON 80k BTUH = 1,650 CFM
• 4 TON MODELS = 1,760 CFM
• 5 TON MODELS = 2,200 CFM
0140F20069-A
B
K
W
H
G
R
D
I
S
C
O
N
N
E
C
T
L
JUNCTION BOX
N
B
U
R
N
E
R
C
O
M
P
A
R
T
M
E
N
T
RD
R
D
WH
B
L
O
W
E
R
C
O
M
P
A
R
T
M
E
N
T
2
4
BK
I
N
D
U
C
E
D
D
R
A
F
T
(
I
D
)
B
L
O
W
E
R
C
WH
3
2
V
A
C
BK
Y
L
G
N
D
B
K
P
U
RD
HIGH FIRE
PRESSURE SWITCH
W
H
ID BLOWER
TWO-STAGE
PRESSURE
SWITCH ASSEMBLY
P
K
W
H
M
A
N
U
A
L
R
E
S
E
T
R
O
L
L
O
U
T
L
I
M
I
T
C
O
N
T
R
O
L
S
R
D
A
U
T
O
R
E
S
E
T
P
R
I
M
A
R
Y
L
I
M
I
T
C
O
N
T
R
O
L
N
O
W
H
1
1
5
1
P
U
V
A
C
C
L
O
W
F
I
R
E
P
R
E
S
S
U
R
E
S
W
I
T
C
H
OR
N
O
P
U
AUTO RESET AUXILIARY LIMIT
CONTROL (TWO ON SOME
MODELS)
2
4
V
3
A
GY
1
2
2
4
5 CIRCUIT
CONNECTOR
4 CIRCUIT
MOTOR
CONNECTOR
4
1
F
U
S
E
1
5
6
5
L
I
N
E
2
RD
2
9
1
4
3
1
OR
1
1
EAC
CONTROL
MODULE
8
BR
RD
BL
1
3
3
5
WH
7
1
3
F
S
4
YL
OR
PK
1
0
GR
R
D
B
L
B
K
PU
YL
PK
W
H
W
H
BK
NEUTRAL
T
H
E
R
M
O
S
T
A
T
CR
1
2
R C G W Y DE
HUM
P
K
R
D
BK
RD
WH
WH
W
H
B
R
G
Y
BK
BK
OR
2
H
O
T
S
U
R
F
A
C
E
I
G
N
I
T
E
R
2 CIRCUIT
CONNECT
OR
1
WH
BK
R
D
G
Y
ECM MTR
HARNESS
3
G
N
D
4
INDOOR AIR CIRCULATOR
BLOWER
4
2
5
B
K
P
K
W
H
1
G
R
1
3
2
BK
BL
B
K
B
K
BLOWER
COMPARTEMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
CHASSIS
GROUND
YL
GR
FLAME
SENSOR
OR
YL
BR
O
R
TWO STAGE
GAS VALVE
(WHITE-ROGERS)
H
I
M
C
TO
115 VAC/ 1
/ 60HZ
POWER SUPPLY WITH
OVERCURRENT
PROTECTION DEVICE
WARNING: DISCONNECT
POWER BEFORE
SERVICING. WIRING
TO UNIT MUST BE
PROPERLY POLARIZED
AND GROUNDED
SW
I
T
C
H
(
PR
ES US
R
E)
F
I
EL
D
S LP
I
C
E
F
I
EL
D
G
R
O
U
N
D
EQ
U
I
PM
NE
T
G
R
O
U
N
D
RP
O
T
EC
T
I
O
N
D
EVI
C
E
PL
U
G
C
O
N
N
CE
T
I
O
N
SW
I
T
C
H
(
T
EM
EP R
AT
U
R
)E
J
U
N
C
T
I
O
N
O
EV R
C
U
R
R
NE
T
T
ER
M
I
N
LA
I
G
N
I
T
RE
H
I
G
H
VO
L
T
GA
E
(
1
1
5
V)
H
I
G
H
OV
L
T
AG
E
F
I
LE
D
L
O
W
VO
L
T
GA
E
(
2
4
V)
L
O
W
VO
L
T
AG
E
F
I
EL
D
GND
MENU NAVIGATION AND SELECTION INSTRUCTIONS
USING PHONE APPLICATION OVER BLUETOOTH NETWORK:
1) CONNECT TO THE FURNACE (INSTRUCTIONS PROVIDED BY
PHONE DURING THE CONNECTION PROCESS).
2) SELECT DESIRED SETTINGS MENU.
3) SELECT ITEM THAT REQUIRES ADJUSTMENT AND MAKE
NECESSARY SELECTION.
4) SUBMIT CHANGES.
USING ON-BOARD PUSH BUTTONS:
1) USE THE RIGHT AND LEFT BUTTONS TO SCROLL BETWEEN
MENUS.
2) USE THE CENTER BUTTON TO SELECT DESIRED MENU WHEN
MENU CODE IS SHOWN ON7-SEGMENT DISPLAYS.
3) USE THE LEFT AND RIGHT BUTTONS TO SCROLL THROUGH
OPTIONS WITHIN THE DESIRED MENU
(THE DISPLAY WILL FLASH WHILE SCROLLING THROUGH
OPTIONS FOR SELECTION) .
4) USE THE CENTER BUTTON TO SELECT THE DISPLAYED OPTION
(WHEN SELECTED THE DISPLAY WILL STOP FLASHING).
5) USE THE CENTER BUTTON TO FINALIZE SELECTION AND
RETURN TO THE MAIN MENU.
AIRFLOW SETTINGS INSTRUCTIONS:
1) FOR NON-COMMUNICATING INSTALLATIONS, SELECT THE TYPE
OF UNIT INSTALLED
IN THE ODS MENU (1AC = SINGLE-STAGE AIR CONDITIONER,
1HP = SINGLE-STAGE HEAT PUMP, 2AC = 2 STAGE AIR CONDITIONER,
2HP = 2 STAGE HEAT PUMP) DEFAULT = OFF (NO OUTDOOR UNIT).
2) THE TONNAGE MENU MUST BE USED TO SELECT COOLING/HEAT
PUMP AIRFLOW (NON-COMMUNICATING INSTALLATION). TONNAGE
SELECTION OPTIONS AND CORRESPONDING AIRFLOW CFM CAN
BE FOUND T
O THE RIGHT. [AIRFLOW = TONNAGE SELECTION X 400]
DEFAULT SELECTION IS 6.0 TONS.
3) [OPTIONAL] USE THE COOLING TRIM MENU (CTF) TO ADJUST THE
COOLING AIRFLOW FROM -10% TO +10% (2% INCREMENTS).
THIS APPLIES FOR 2 STAGE COMMUNICATING OUTDOOR UNITS
AND SINGLE OR 2 STAGE NON-COMMUNICATING OUTDOOR UNITS.
4) [OPTIONAL] USE THE HEATING TRIM MENU (HTF) TO ADJUST THE
HEAT PUMP AIRFLOW FROM -10% TO +1.
NOTES:
1. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED
USED WHEN SERVICING.
2. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
C. USE COPPER
CONDUCTORS ONLY.
3. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C.
AND LOCAL CODES.
4. WHEN THIS FURNACE IS PAIRED WITH NON R-32 REFRIGERANT
SYSTEMS, DEFAULT SETTINGS WILL NEED TO BE CHANGED. REFER
TO INSTALLATION MANUAL FOR FURTHER INSTRUCTIONS.
5. FERRITE CORE INSTALLED AT THIS LOCATION. ONLY APPLICABLE
TO SOME MODELS.
40 VA
TRANSFORMER
YL
BR
GY
OR
WH
OR
RD
P
U
PK
R
D
P
K
WIRE
COLOR:
WHITE
BLACK
YELLOW
BLUE
RED
ORANGE
BROWN
TAN
PINK
GRAY
GREEN
PURPLE
VIOLET
COLOR
DESIGNATION:
WH
BK
YL
BL
RD
OR
BR
TN
PK
GY
GR
PU
VT
A2L SENSOR
CONNECTOR
A2L MODE IS ENABLED BY DEFAULT
REFER TO INSTALLATION MANUAL
FOR FURTHER INSTRUCTIONS.
GND
1
2
5V
G
Y
SEE NOTE 5
CENTER
RIGHTLEFT
STATUS
CODE

Specifications

Indexed Terms: Gas Furnace, Variable-Speed

Goodman GRVT800805CX Questions and Answers