Owner’s Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning unit.
Make sure to save this manual for future
reference.
ROOM AIR CONDITIONER
SPLIT-TYPE
background
CONTENTS
SAFETY PRECAUTIONS
02
CARE AND MAINTENANCE
12
TROUBLESHOOTING
14
16
OPERATION INSTRUCTIONS
01
background
02
SAFETY PRECAUTIONS
WARNING
CAUTION
Explanation of Symbols
WARNING
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by
a person responsible for their safety. Children should be supervised to ensure that
they do not play with the appliance.
This symbol indicates the possibility of personnel injury or loss of
life.
This symbol indicates the possibility of property damage or serious
consequences.
If an abnormal situation arises (like a burning smell), immediately turn o the
unit and disconnect the power. Call your dealer for instructions to avoid electric
shock, fire or injury.
Do not insert fingers, rods or other objects into the air inlet or outlet. This may
cause injury, since the fan may be rotating at high speeds.
Do not use flammable sprays such as hair spray, lacquer or paint near the unit.
This may cause fire or combustion.
Do not operate the air conditioner in places near or around combustible gases.
Emitted gas may collect around the unit and cause explosion.
Do not operate your air conditioner in a wet room such as a bathroom or laundry
room. Too much exposure to water can cause electrical components to short
circuit.
Do not expose your body directly to cool air for a prolonged period of time.
If the air conditioner is used together with burners or other heating devices,
thoroughly ventilate the room to avoid oxygen deficiency.
In certain functional environments, such as kitchens, server rooms, etc., the use
of specially designed air-conditioning units is highly recommended.
Do not allow children to play with the air conditioner. Children must be
supervised around the unit at all times.
●
●
●
●
●
●
●
●
●
●
WARNING FOR PRODUCT USE
Turn o the air conditioner and disconnect the power before performing any
cleaning, installation or repairing. Failure to do so can cause electric shock.
It is really important that you read Safety Precautions Before Operation and
Installation. Incorrect installation due to ignoring instructions can cause serious
damage or injury. The seriousness of potential damage or injuries is classified as
either a WARNING or CAUTION.
background
03
ELECTRICAL WARNINGS
Only use the specified wire. If the wire is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a
hazard.
The product must be properly grounded at the time of installation, or electric
shock may occur.
For all electrical work, follow all local and national wiring standards, regulations,
and the Installation Manual. Connect cables tightly, and clamp them securely to
prevent external forces from damaging the terminal. Improper electrical
connections can overheat and cause fire, and may also cause shock. All electrical
connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
All wiring must be properly arranged to ensure that the control board cover can
close properly. If the control board cover is not closed properly, it can lead to
corrosion and cause the connection points on the terminal to heat up, catch fire,
or cause electric shock.
Disconnection must be incorporated in the fixed wiring in accordance with the
wiring rules.
Do not share the electrical outlet with other appliances. Improper or insucient
power supply can cause fire or electric shock.
If connecting power to fixed wiring, an all-pole disconnection device which has
at least 3mm clearances in all poles, and have a leakage current that may exceed
10mA, the residual current device (RCD) having a rated residual operating current
not exceeding 30mA, and disconnection must be incorporated in the fixed wiring
in accordance with the wiring rules.
●
●
●
●
●
●
●
Do not clean the air conditioner with combustible cleaning agents. Combustible
cleaning agents can cause fire or deformation.
Turn o the device and disconnect the power before cleaning. Failure to do so
can cause electric shock.
Do not clean the air conditioner with excessive amounts of water.
●
●
●
CLEANING AND MAINTENANCE WARNINGS
Turn o the air conditioner and disconnect the power if you are not going to use
it for a long time.
Turn o and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not operate the air conditioner with wet hands. This may cause electric shock.
Do not use device for any other purpose than its intended use.
Do not climb onto or place objects on top of the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with doors or
windows open, or if the humidity is very high.
●
●
●
●
●
●
●
CAUTION
●
●
●
●
WARNING FOR USING FLAMMABLE REFRIGERANTS
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
background
0404
●
LEAK DETECTION SYSTEM installed. Unit must be powered except for service.
For the unit with refrigerant sensor, when the refrigerant sensor detects
refrigerant leakage, the indoor unit will display a error code and emit a buzzing
sound, the compressor of outdoor unit will immediately stop, and the indoor fan
will start running. The service life of the refrigerant sensor is 15 years. When the
refrigerant sensor malfunctions, the indoor unit will display the error code “FHCC”.
The refrigerant sensor can not be repaired and can only be replaced by the
manufacture. It shall only be replaced with the sensor specified by the
manufacture. (Applicable to the units with refrigerant sensors only)
For R454B refrigerant charge amount and minimum room area:
The machine you purchased may be one of the types in the table below. The indoor
and outdoor units are designed to be used together. Please check the machine you
purchased. The indoor unit should be installed at least 7.6ft/2.3m above from the
floor, the height of the room cannot be less then 7.3ft/2.2m, and the minimum room
area of operating or storage should be as specified in the following table:
For the units with refrigerant sensors, when the unit detects a refrigerant leak,
the minimum airflow of the indoor unit is as follows:
Indoor unit
Outdoor unit
Model
9K
12K
18K
SENA-18HF-ICG
SENA-12HF-ICG
SENA-09HF-ICG
SEN
A-09HF-OG
SENA-12HF-OG
SENA-18HF-OG
24K
SENA-24HF-ICG
SENA-24HF-OG
600m³/h
710m³/h
760m³/h
1300m³/h
353CFM
418CFM
448CFM
765CFM
Indoor Nominal
air volume
background
05
m
c or
mREL
[ozs/kg]
7.6/2.3 7.9/2.4 8.6/2.6 9.2/2.8
<=62.6/1.776
Area
formula
h
inst
[ft/m]
12/1.10
A
min
is the required minimum room area in ft /m
m
c
is the actual refrigerant charge in the system in oz/kg
m
REL is the refrigerant releaseable charge in oz/kg (Applicable to the
units with refrigerant sensors only)
h
inst
is the height of the bottom of the appliance relative to the floor of
the room after installation.
WARNING: The minimum room area or minimum room area of
conditioned space is based on releasable charge and total
system refrigerant charge.
2 2
63.4/1.8
70.5/2.0
77.5/2.2
84.6/2.4
91.7/2.6
98.7/2.8
105.8/3.0
112.8/3.2
119.9/3.4
126.9/3.6
134/3.8
141.0/4.0
148.1/4.2
155.1/4.4
162.2/4.6
169.2/4.8
176.3/5.0
47/4.35
52/4.83
58/5.31
63/5.80
68/6.28
73/6.76
78/7.24
84/7.73
89/8.21
94/8.69
99/9.17
104/9.66
110/10.14
115/10.62
120/11.11
125/11.59
130/12.07
51/4.68
56/5.20
62/5.72
68/6.24
73/6.76
79/7.28
84/7.80
90/8.32
96/8.84
101/9.36
107/9.88
112/10.40
118/10.92
124/11.44
129/11.96
135/12.48
140/13.00
55/5.07
61/5.64
67/6.20
73/6.76
79/7.32
85/7.89
91/8.45
97/9.01
104/9.58
110/10.14
116/10.70
122/11.27
128/11.83
134/12.39
140/12.96
146/13.52
152/14.08
6.0~7.3/
1.8~2.2
60/5.53
67/6.15
73/6.76
80/7.38
86/7.99
93/8.60
100/9.22
106/9.83
113/10.45
120/11.06
126/11.68
133/12.29
139/12.90
146/13.52
153/14.13
159/14.75
166/15.36
57/5.29
64/5.88
70/6.47
83/7.64
89/8.23
95/8.82
102/9.41
108/9.99
114/10.58
121/11.17
127/11.76
133/12.34
140/12.93
146/13.52
152/14.11
159/14.69
76/7.06
9.9/3.0
44/4.06
49/4.51
54/4.96
59/5.41
64/5.86
68/6.31
73/6.76
78/7.21
83/7.66
88/8.11
93/8.56
97/9.01
102/9.46
107/9.91
112/10.37
117/10.82
122/11.27
background
06
1. Installation(where refrigerant pipes are allowed)
- Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorises their competence to handle refrigerants
safely in accordance with an industry recognised assessment specification.
- Maintenance and repair requiring the assistance of other skilled personnel shall
be carried out under the supervision of the person competent in the use of
flammable refrigerants.
- That the installation of pipe-work shall be kept to a minimum.
- That pipe-work shall be protected from physical damage.
- Where refrigerant pipes shall be compliance with national gas regulations.
- That mechanical connections shall be accessible for maintenance purposes.
- Be more careful that foreign matter(oil, water,etc) does not enter the piping.
Also, when storing the piping, securely seal the opening by pinching, taping, etc.
- Appliance shall be stored in a well ventilated area where the room size
corresponds to the room area as specifiec for operation.
- Appliance shall be stored in a well ventilated area where the room size
corresponds to the room area as specifiec for operation.
2. When a FLAMMABLE REFRIGERANT is used, the requirements for installation
space of appliance and /or ventilation requirements are determined according to
- the mass charge amount(M) used in the appliance,
- the installation location,
- the type of ventilation of the location or of the appliance.
- piping material, pipe routing, and installation shall include protection from
physical damage in operation and service, and be in compliance with national
and local codes and standards, such as ASHRAE 15, IAPMO Uniform Mechanical
Code, ICC International Mechanical Code, or CSA B52. All field joints shall be
accessible for inspection prior to being covered or enclosed.
- that protection devices, piping, and fittings shall be protected as far as
possible against adverse environmental eects, for example, the danger of water
collecting and freezing in relief pipes or the accumulation of dirt and debris;
- that piping in refrigeration systems shall be so designed and installed to
minimize the likelihood of hydraulic shock damaging the system;
- that steel pipes and components shall be protected against corrosion with a
rustproof coating before applying any insulation;
- that precautions shall be taken to avoid excessive vibration or pulsation;
- the minimum floor area of the room shall be mentioned in the form of a table
or a single figure without reference to a formula;
- after completion of field piping for split systems, the field pipework shall be
pressure tested with an inert gas and then vacuum tested prior to refrigerant
charging, according to the following requirements:
- Joints shall be tested with detection equipment with a capability of 5 g/year of
refrigerant or better, with the equipment in standstill and under operation or
under a pressure of at least these standstill or operation conditions after
installation. Detachable joints shall NOT be used in the indoor side of the unit
(brazed, welded joint could be used).
- In cases that require mechanical ventilation, ventilation openings shall be kept
clear of obstruction.
a. The minimum test pressure for the low side of the system shall be the low side
design pressure and the minimum test pressure for the high side of the system
shall be the high side design pressure, unless the high side of the system can
not be isolated from the low side of the system in which case the entire system
shall be pressure tested to the low side design pressure.
b. The test pressure after removal of pressure source shall be maintained for at
least 1 h with no decrease of pressure indicated by the test gauge, with test
gauge resolution not exceeding 5% of the test pressure.
background
07
c. During the evacuation test, after achieving a vacuum level specified in the
manual or less, the refrigeration system shall be isolated from the vacuum pump
and the pressure shall not rise above 1500 microns within 10 min. The vacuum
pressure level shall be specified in the manual, and shall be the lessor of 500
microns or the value required for compliance with national and local codes and
standards, which may vary between residential, commercial,and industrial
buildings.
-- field-made refrigerant joints indoors shall be tightness tested according to the
following requirements: The test method shall have a sensitivity of 5 grams per
year of refrigerant or better under a pressure of at least 0,25 times the
maximum allowable pressure. No leak shall be detected.
-- Any servicing shall be performed only as recommended by the manufacturer.
3 . Qualification of workers
Any maintenance, service and repair operations must be required qualification
of the working personnel. Every working procedure that aects safety means
shall only be carried out by competent persons that joined the training and
achieved competence should be documented by a certificate. The training of
these procedures is carried out by national training organizations or
manufacturers that are accredited to teach the relevant national competency
standards that may be set in legislation. All training shall follow the ANNEX HH
requirements of UL 60335-2-40 4th Edition.
Examples for such working procedures are:
• breaking into the refrigerating circuit;
• opening of sealed components;
• opening of ventilated enclosures.
Information Servicing
1. Checks to the area
3. General work area
4. Checking for presence of refrigerant
5. Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated
parts, appropriate fire extinguishing equipment shall be available to hand. Have a
dry power or CO
2 fire extinguisher adjacent to the charging area.
2. Work procedure
All maintenance sta and others working in the local area shall be instructed on the
nature of work being carried out. work in confined sapces shall be avoided.
Prior to beginning work on systems containing flammable refrigerants, safety checks
are necessary to ensure that the risk of ignition is minimised. For repair to the
refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
Works shall be undertaken under a controlled procedure so as to minimise the risk
of a flammable gas or vapour being present while the work is being performed.
The area shall be checked with an appropriate refrigerant detector prior to and
during work, to ensure the technician is aware of potentially flammable atmospheres.
Ensure that the leak detection equipment being used is suitable for use with
flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
background
08
6. No ignition sources
No person carrying out work in relation to a REFRIGERATING SYSTEM which
involves exposing any pipe work shall use any sources of ignition in such a manner
that it may lead to the risk of fire or explosion. All possible ignition sources, including
cigarette smoking, should be kept suciently far away from the site of installation,
repairing, removing and disposal, during which refrigerant can possibly be released
to the surrounding space. Prior to work taking place, the area around the equipment
is to be surveyed to make sure that there are no flammable hazards or ignition risks.
“No Smoking” signs shall be displayed.
7. Ventilated area
Ensure that the area is in the open or that it it adequately ventilated before breaking
into the system or conducting any hot work. A degree of ventilation shall continue
during the period that the work is carried out. The ventilation should safely disperse
any released refrigerant and preferably expel it externally into the atmosphere.
8. Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose
and to the correct specification. At all times the manufacturer’s maintenance and
service guidelines shall be followed. If in doubt consult the manufacturer’s technical
department for assistance. The following checks shall be applied to installations
using FLAMMABLE REFRIGERANTS:
the actual refrigerant charge is in accordance with the room size within which
the refrigerant containing parts are installed;
the ventilation machinery and outlets are operating adequately and are not
obstructed;
if an indirect refrigerating circuit is being used, the secondary circuits shall be
checked for the presence of refrigerant;
marking to the equipment continues to be visible and legible, marking and signs
that are illegible shall be corrected;
9. Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks
and component inspection procedures. If a fault exists that could compromise
safety, then no electrical supply shall be connected to the circuit until it is
satisfactorily dealt with. If the fault cannot be corrected immediately but it is
necessary to continue operation, and adequate temporary solution shall be used.
This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
that capacitors are discharged: this shall be done in a safe manner to avoid
possibility of sparking;
that there no live electrical components and wiring are exposed while charging,
recovering or purging the system;
that there is continuity of earth bonding.
10. Sealed electrical components shall be replaced if it's damage.
11. Intrinsically safe components must be replaced if it's damage.
refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of materials
which are inherently resistant to being corroded or are suitably protected against
being so corroded.
background
09
12. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental eects. The check shall
also take into account the eects of aging or continual vibration from sources such
as compressors or fans.
13. Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching
for or detection of refrigerant leaks. A halide torch(or any other detector using a
naked flame) shall not be used.
The following leak detection methods are deemed acceptable for refrigerant
systems. Electronic leak detectors may be used to detect refrigerant leaks but, in the
case of FLAMMABLE REFRIGERANTS, the sensitivity may not be adequate, or may
need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free
area.) Ensure that the detector is not a potential source of ignition and is suitable for
the refrigerant used. Leak detection equipment shall be set at a percentage of the
LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the
appropriate percentage of gas (25 % maximum) is confirmed.
Leak detection fluids are also suitable for use with most refrigerants but the use of
detergents containing chlorine shall be avoided as the chlorine may react with the
refrigerant and corrode the copper pipe-work.
NOTE Examples of leak detection fluids are
- bubble method,
- fluorescent method agents.
If a leak is suspected, all naked flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall
be recovered from the system, or isolated (by means of shut o valves) in a part of
the system remote from the leak. See the following instructions of removal of
refrigerant.
14. Removal and evacuation
When breaking into the refrigerant circuit to make repairs - or for any other purpose
conventional procedures shall be used. However, for flammable refrigerants it is
important that best practice be followed, since flammability is a consideration.
The following procedure shall be adhered to:
safely remove refrigerant following local and national regulations;
evacuate;
purge the circuit with inert gas (optional for A2L);
evacuate (optional for A2L);
continuously flush or purge with inert gas when using flame to open circuit; and
open the circuit.
The refrigerant charge shall be recovered into the correct recovery cylinders if
venting is not allowed by local and national codes. For appliances containing
flammable refrigerants, the system shall be purged with oxygen-free nitrogen to
render the appliance safe for flammable refrigerants. This process might need to be
repeated several times. Compressed air or oxygen shall not be used for purging
refrigerant systems.
For appliances containing flammable refrigerants, refrigerants purging shall be
achieved by breaking the vacuum in the system with oxygen-free nitrogen and
continuing to fill until the working pressure is achieved, then venting to atmosphere,
and finally pulling down to a vacuum (optional for A2L). This process shall be
repeated until no refrigerant is within thesystem (optional for A2L). When the final
oxygen-free nitrogen charge is used, the system shall be vented down to
atmospheric pressure to enable work to take place.
The outlet for the vacuum pump shall not be close to any potential ignition sources,
and ventilation shall be available.
background
10
15. Charging procedures
In addition to conventional charging procedures, the following requirements shall
be followed:
Works shall be undertaken with appropriate tools only (In case of uncertainty,
please consult the manufacturer of the tools for use with flammable refrigerants)
Ensure that contamination of dierent refrigerants does not occur when using
charging equipment. Hoses or lines shall be as short as possible to minimize the
amount of refrigerant contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed prior to charging the system with
refrigerant.
Label the system when charging is complete(if not already).
Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system it shall be pressure tested with oxygen free
nitrogen(OFN). The system shall be leak tested on completion of charging but
prior to commissioning. A follow up leak test shall be carried out prior to leaving
the site.
16. Decommissioning
Before carrying out this procedure, it is essential that the technician is completely
familiar with the equipment and all its detail. It is recommended good practice that
all refrigerants are recovered safely. Prior to the task being carried out, an oil and
refrigerant sample shall be taken in case analysis is required prior to re-use of
recovered refrigerant. It is essential that electrical power is available before the task
is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically
c) Before attempting the procedure ensure that:
mechanical handling equipment is available, if required, for handling refrigerant
cylinders;
all personal protetive equipment is available and being used correctly;
the recovery process is supervised at all times by a competent person;
recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed
from various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g)Start the recovery machine and operate in accordance with instructions.
h)Do not overfill cylinders (no more than 80 % volume liquid charge)
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make
sure that the cylinders and the equipment are removed from site promptly and all
isolation valves on the equipment are closed o.
k) Recovered refrigerant shall not be charged into another refrigeration system
unless it has been cleaned and checked.
17. Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied
of refrigerant. The label shall be dated and signed. For appliances containing
FLAMMABLE REFRIGERANTS, ensure that there are labels on the equipment
stating the equipment contains FLAMMABLE REFRIGERANT.
18. Recovery
When removing refrigerant from a system, either for servicing or decommissioning,
it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant
recovery cylinders are employed. Ensure that the correct number of cylinders for
holding the total system charge is available. All cylinders to be used are designated
background
11
for the recovered refrigerant and labelled for that refrigerant (i. e. special cylinders
for the recovery of refrigerant). Cylinders shall be complete with pressure-relief
valve and associated shut-o valves in good working order. Empty recovery
cylinders are evacuated and, if possible,cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions
concerning the equipment that is at hand and shall be suitable for the recovery of
the flammable refrigerant. If in doubt, the manufacturer should be consulted. In
addition, a set of calibrated weighing scales shall be available and in good working
order. Hoses shall be complete with leak-free disconnect couplings and in good
condition.
The recovered refrigerant shall be processed according to local legislation in the
correct recovery cylinder, and the relevant waste transfer note arranged. Do not
mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been
evacuated to an acceptable level to make certain that flammable refrigerant does
not remain within the lubricant. The compressor body shall not be heated by an
open flame or other ignition sources to accelerate this process. When oil is drained
from a system, it shall be carried out safely.
1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations.
2. Marking of equipment using signs
Compliance with local regulations.
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations.
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s
instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to
the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will
be determined by local regulations.
19. Transportation, marking and storage for units
CAUTION
CAUTION
CAUTION
CAUTION
WARNING
This symbol shows that this appliance used a flammable
refrigerant. If the refrigerant is leaked and exposed to an
external ignition source, there is a risk of fire.
This symbol shows that the operation manual should be
read carefully.
This symbol shows that information is available such as
the operating manual or installation manual.
This symbol shows that a service personnel should be
handling this equipment with reference to the
installation manual.
Explanation of symbols displayed on the indoor unit or outdoor unit
background
12
OPERATION INSTRUCTIONS
Dierent models have dierent front panel and display window. Not all the indicators describing
below are available for the air conditioner you purchased. Please check the indoor display window
of the unit you purchased.
Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may
be slightly dierent. The actual shape shall prevail.
This display panel on the indoor unit can be used to operate the unit in case the remote control
has been misplaced or is out of batteries.
●
●
●
NOTE
Indoor Unit Display
•
•
FORCED COOL mode: In FORCED COOL mode, the Operation light flashes. The system will then
turn to AUTO after it has cooled with a high wind speed for 30 minutes. The remote control will be
disabled during this operation.
OFF mode: When the display panel is turned o, the unit turns o and the remote control is
re-enabled.
Operation
indicator
Timer
indicator
PRE-DEF indicator
(pre-heating/defrost)
Alarm indicator
Air inlet
Corner air outlet
Louver
Display panel
When wireless control
feature is activated
LED display
background
Auto-Restart
In case of power failure, the system will
immediately stop. When power returns, the
Operation light on the indoor unit will flash. To
restart the unit, press the ON/OFF button on
the remote control. If the system has an auto
restart function, the unit will restart using the
same settings.
Louver Angle Memory Function
For the units with louver angle memory function.
When the unit restarts after a power failure, the
angle of the horizontal louvers will automatically
return to the previous position.
The angle of the horizontal louver should not
be set too small as condensation may form and
drip into the machine. To reset the louver, press
the manual button, which will reset the
horizontal louver settings.
Other features
Three-minute protection feature
A protection feature prevents the air
conditioner from being activated for
approximately 3 minutes when it restarts
immediately after operation.
The SLEEP function is used to decrease energy
use while you sleep (and don’t need the same
temperature settings to stay comfortable). This
function can only be activated via remote control.
And the Sleep function is not available in FAN or
DRY mode.
Press the SLEEP button when you are ready to
go to sleep. When in COOL mode, the unit will
increase the temperature by 1°C (2°F) after 1 hour,
and will increase an additional 1°C (2°F) after
another hour.
When in HEAT mode, the unit will decrease the
temperature by 1°C (2°F) after 1 hour, and will
decrease an additional 1°C (2°F)after another hour.
Set
temperature
1hr
1hr
Keep
running
SLEEP Operation
Saving energy during sleep
Heat mode( -1 C/2 F) per hour
for the first two hours
Cool mode(+1 C/2 F) per hour
for the first two hours
The sleep feature will stop after 8 hours and the
system will keep running with final situation.
Sleep Operation
●
Default Setting
When the air conditioner restarts after a power
failure, it will default to the factory settings
(AUTO mode, AUTO fan, 24°C (76°F)). This
may cause inconsistencies on the remote
control and unit panel. Use your remote
control to update the status.
●
●
●
●
●
13
NOTE
Every time the air conditioner is powered on, a buzzing sound will be heard to indicate that the
product has been powered on normally. If there is no sound, it is possible that the unit is abnormal.
Please power on again or check the circuit.
The actual functions are subject to the product you purchased, please check the indoor display and
remote control of your AC. See the <Remote Controller Manual> for more features.
Heat exchanger dust removal function
This feature helps keep the outdoor coil cleaner
and may extend the duration between regular
maintenance intervals depending on local
conditions. When the unit is turned o, a 10
seconds delay occours then the outdoor fan runs
in reverse rotation for 70 seconds to blow o
loose accumulated dust and debris.
Refrigerant Leakage Detection
• When the system detects a malfunction of the
refrigerant, the indoor unit will automatically
display the following error codes:
“EL0C (System lacks refrigerant)” ,
“EHC1 (Refrigerant sensor detects leakage)”,
“EHC2 (Working condition of the refrigerant
sensor is out of range and leakage is detected)”,
“EHC3 (Working condition of the refrigerant
sensor is out of range)”, or
“ECC1 (Other indoor unit refrigerant sensor
detects leakage (Multi-zone)”.
• When “EHC1” or “EHC2” error occurs, the
buzzer will continue to beep for 5 to 6 minutes
before stopping. You can also press any button
on the remote controller to stop the buzzer.
Note: Error codes of “EHC1”, “EHC2”,“EHC3”
and “ECC1” are only applicable to the units with
refrigerant sensor.
background
14
1: Open the screw
cover and twist out
the screw.
2: Press the buttons
on both sides to pull
out the air inlet
frame.
Separate the frame from the filter assembly.
Clean filter assembly.
Take out the fresh air filter.
(Optional )Please note that
the fresh air filter cannot be
cleaned with water. It is
recommended to replace it
regularly.
Remove the air filter.
Cleaning Your Indoor Unit(Air Filter)
CARE AND MAINTENANCE
• The cooling eciency of your unit and your health would be damaged for the glogged AC,
Make sure to clean the filter every two weeks.
• Always TURN OFF your AC system and disconnect its power supply before cleaning or
maintenance.
• Only use a soft, dry cloth to wipe the unit clean. You can use a cloth soaked in warm water to wipe
it clean if the unit is especially dirty.
• Do not use chemicals or chemically treated cloths to clean the unit
• Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can
cause the plastic surface to crack or deform.
• Do not use water hotter than 40°C (104°F) to clean the front panel. This can cause the panel to
deform or become discolored.
CAUTION
Step 1:
Step 2:
Step 3:
WARNING
Removing and cleaning the filter can be dangerous. Removal and maintenance must be performed
by a certified technician.
Rinse the filter with clean water and allow it
to air-dry. DO NOT let the filter dry in direct
sunlight.
Reinstall the filter.
Clean the air filter by vacuuming the surface
or washing it in warm water with mild
detergent.
If using a vacuum cleaner, the
inlet side should face the vacuum.
If using water, the inlet side should
face down and away from the
water stream.
background
Maintenance –
Long Periods of Non-Use
If you plan not to use your air conditioner for
an extended period of time, do the following:
Clean all filters Turn on FAN function until
unit dries out completely
Turn o the unit and
disconnect the power
Remove batteries
from remote control
Maintenance –
Pre-Season Inspection
After long periods of non-use, or before periods of
frequent use, do the following:
Check for damaged wires
Clean all filters Check for leaks
Replace batteriesMake sure nothing is blocking
all air inlets and outlets
Maintenance your AC.
CAUTION
• Before changing the filter or cleaning, turn o
the unit and disconnect its power supply.
• When removing filter, do not touch metal
parts in the unit. The sharp metal edges can
cut you.
• Do not use water to clean the inside of the
indoor unit. This can destroy insulation and
cause electrical shock.
• Do not expose filter to direct sunlight when
drying. This can shrink the filter.
• Any maintenance and cleaning of outdoor
unit should be performed by an authorized
dealer or a licensed service provider.
• Any unit repairs should be performed by an
authorized dealer or a licensed service provider.
15
background
Issue Possible Causes
Unit does not turn
on when pressing
ON/OFF button
The Unit has a 3-minutes protection feature that prevents the unit from overloading.
The unit cannot be restarted within three minutes of being turned o.
The unit may change its setting to prevent frost from forming on the unit.
Once the temperature increases, the unit will start operating in the
previously selected mode again.
The set temperature has been reached, at which point the unit turns o the
compressor. The unit will continue operating when the temperature
fluctuates again.
The indoor unit
emits white mist
In humid regions, a large temperature dierence between the room’s air
and the conditioned air can cause white mist.
Both the indoor and
outdoor units emit
white mist
When the unit restarts in HEAT mode after defrosting, white mist may be
emitted due to moisture generated from the defrosting process.
The unit changes from
COOL/HEAT mode to
FAN mode
The indoor unit makes
noises
A rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to
expansion and contraction of the unit’s plastic parts.
Both the indoor unit
and outdoor unit make
noises
Low hissing sound during operation: This is normal and is caused by refrigerant
gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping or
changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
Cooling and Heating Models: If the Operation light and PRE-DEF (Pre-heating/
Defrost) indicators are lit up, the outdoor temperature is too cold and the unit’s
anti-cold wind is activated in order to defrost the unit.
In Cooling-only Models: If the “Fan Only” indicator is lit up, the outdoor
temperature is too cold and the unit’s anti-freeze protection is activated in
order to defrost the unit.
A squeaking sound is heard when the system is OFF or in COOL mode. The
noise is also heard when the drain pump (optional) is in operation.
Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
TROUBLESHOOTING
If any of the following conditions occurs, turn o your unit immediately!
• The power cord is damaged or abnormally warm
• You smell a burning odor
• The unit emits loud or abnormal sounds
• A power fuse blows or the circuit breaker frequently trips
• Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER
IMMEDIATELY.
CAUTION
16
background
Issue Possible Causes
The outdoor unit
makes noises
The unit will make dierent sounds based on its current operating mode.
Dust is emitted from
either the indoor or
outdoor unit
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.
The unit emits a
bad odor
The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operations.
The unit’s filters have become moldy and should be cleaned.
The fan of the outdoor
unit does not operate
During operation, the fan speed is controlled to optimize product operation.
NOTE:
If problem persists, contact a local dealer or your nearest customer service center. Provide
them with a detailed description of the unit malfunction as well as your model number.
When troubles occur, please check the following points before contacting a repair company.
Problem Possible Causes Solution
Poor Cooling
Performance
Temperature setting may be higher
than ambient room temperature
Lower the temperature setting
The heat exchanger on the indoor
or outdoor unit is dirty
Clean the aected heat exchanger
The air filter is dirty
Remove the filter and clean it according to
instructions
The air inlet or outlet of either
unit is blocked
Turn the unit o, remove the obstruction
and turn it back on
Doors and windows are open
Make sure that all doors and windows are
closed while operating the unit
Excessive heat is generated
by sunlight
Close windows and curtains during periods
of high heat or bright sunshine
Too many sources of heat in the
room (people, computers,
electronics, etc.)
Reduce amount of heat sources
Low refrigerant due to leak
or long-term use
Check for leaks, re-seal if necessary and
top o refrigerant
17
background
Problem Possible Causes Solution
The unit is not
working
Power failure
Wait for the power to be restored
The power is turned o Turn on the power
The fuse is burned out
Replace the fuse
Remote control batteries are dead
Replace batteries
The Unit’s 3-minutes protection
has been activated
Wait three minutes after restarting
the unit
Timer is activated
Turn timer o
The unit starts and
stops frequently
There’s too much or too little
refrigerant in the system
Check for leaks and recharge the
system with refrigerant.
Incompressible gas or moisture
has entered the system.
Evacuate and recharge the system
with refrigerant
The compressor is broken Replace the compressor
The voltage is too high or
too low
Install a manostat to regulate the
voltage
Poor heating
performance
The outdoor temperature is
extremely low
Use auxiliary heating device
Cold air is entering through
doors and windows
Make sure that all doors and
windows are closed during use
Low refrigerant due to leak or
long-term use
Check for leaks, re-seal if necessary
and top o refrigerant
Indicator lamps
continue flashing
The unit may stop operation or continue to run safely. If the indicator
lamps continue to flash or error codes appear, wait for about 10
minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact your nearest
customer service center.
Error code appears and
begins with the letters
as the following in the
window display of
indoor unit:
E(x), P(x), F(x)
EH(xx), EL(xx), EC(xx)
PH(xx), PL(xx), PC(xx)
•
•
•
NOTE:
If your problem persists after performing the checks and diagnostics above,
turn o your unit immediately and contact an authorized service center.
System circuit is blocked
Determine which circuit is blocked and
replace the malfunctioning piece of
equipment
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to
the service website, please check for the latest version.
18
background
QS003U-Q(R454B)
16123000A33036
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to
the service website, please check for the latest version.