Scotsman Fs1222lx

Product's Documents

Below are documents related to this product, you can read online or download:

User Manual

This is the main product document for model FS1222LX.

The file format is pdf, 17 pages, you can download this manual here .

background
Installation and User’s Manual for
Remote Low Side Modular Flake and Nugget Ice
Machines
Prodigy Plus A Series Models with R449A
NS0922LX, NH0922LX, NS1322LX, NH1322LX,
FS1222LX, and FS1522LX
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 2
Introduction
This ice machine is the result of years of experience
with aked and nugget ice machines. The latest in
electronics has been coupled with the time tested
Scotsman aked ice system to provide reliable ice
making and the features needed by customers.
The features include simple conductivity water level
sensing, evaporator clearing at shut down, photo-eye
sensing bin control and the ability to add options.
Contents
Installation ...................................................................... Page 3
Location ........................................................................ Page 4
Cabinet Layout .................................................................. Page 5
Unpacking ...................................................................... Page 6
Water .......................................................................... Page 7
Electrical ....................................................................... Page 8
Refrigeration .................................................................... Page 9
Final Check List .................................................................. Page 10
Initial Start Up ................................................................... Page 11
Maintenance: Scale Removal and Sanitation ........................................... Page 12
Maintenance: Scale Removal and Sanitation Continued .................................. Page 13
Options ........................................................................ Page 14
What to Do Before Calling for Service ................................................. Page 15
Service Diagnosis ................................................................ Page 16
background
August 2026
Page 3
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
Installation
This machine is designed to be used indoors, in a
controlled environment. Operation outside the limits
listed here will void the warranty.
Air temperature limits
Minimum Maximum
Ice maker 50
o
F. 100
o
F.
Water temperature limits
Minimum Maximum
All models 40
o
F. 100
o
F.
Water pressure limits (potable)
Minimum Maximum
All models 20 psi 80 psi
Voltage limits
Minimum Maximum
115 volt 104 126
Minimum conductivity (RO water)
• 10 microSiemens / CM
Water Quality (ice making circuit)
• Potable
The quality of the water supplied to the ice machine
will have an impact on the time between cleanings
and ultimately on the life of the product. Water can
contain impurities either in suspension or in solution.
Suspended solids can be ltered out. In solution
or dissolved solids cannot be ltered, they must be
diluted or treated. Water lters are recommended
to remove suspended solids. Some lters have
treatment in them for suspended solids. Check with a
water treatment service for a recommendation.
RO water. This machine can be supplied with Reverse
Osmosis water, but the water conductivity must be no
less than 10 microSiemens/cm.
Potential for Airborne Contamination
Installing an ice machine near a source of yeast
or similar material can result in the need for more
frequent sanitation cleanings due to the tendency of
these materials to contaminate the machine.
Most water lters remove chlorine from the water
supply to the machine which contributes to this
situation. Testing has shown that using a lter that
does not remove chlorine, such as the Scotsman
Aqua Patrol, will greatly improve this situation.
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
maintenance, corrections to installations, or situations
when the machine is operated in circumstances that
exceed the limitations printed above.
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 4
Location
While the machine will operate satisfactorily within the
air and water temperature limits, it will operate more
e󰀩ciently when those temperatures are nearer the
lower limits. Avoid locations that are hot, dusty, greasy
or conned.
Options
The standard machine will make ice until ice lls
the bin and blocks an infrared light beam inside the
bottom of the machine. A eld installed kit is available
to adjust the ice level lower. That kit number is KVS.
The standard controller has excellent diagnostic
capabilities and communicates to the user through the
AutoAlert light panel, seen through the front panel.
There is a eld installed kit that can log data and
provide additional information when the front panel is
removed. That kit number is KSBU. A similar kit adds
network connectivity, and its number is KSBU-N.
Bin compatibility
All models are the same width: 22 inches. All models
are the same depth: 24 inches.
Bin & adapter list:
• B322S – no adapter needed
• B330P – Use KBT27
• B530P – Use KBT27
• B530S – Use KBT27
• B842S – Use KBT39
• B948S - Use KBT38 for a single unit
• B948S – Use KBT38-2X for two units side by side
BL1048S, BL1360S and BL1660S upright bins include
ller panels to accommodate a single 22 inch wide
ake or nugget ice machine. No adapter is needed.
Dispenser compatibility
Only nugget ice models may be used with ice
dispensers. Flaked ice is not dispensable.
• IOD150 – use KBT82 and KNUGAGT.
• IOD200 – use KBT83 and KNUGAGT and KVS.
• IOD250 – use KBT83 and KNUGAGT and KVS.
See sales literature for other brand model ice and
beverage dispenser applications.
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in
the illustrations on the next page.
Line Set
NRTE45 is a non-precharged tubing kit that contains
a 45 foot 3/8" liquid line and a 45 foot 5/8" suction
line. Tubes are supplied nitrogen charged and
capped.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specications and
design are subject to change without notice.
background
August 2026
Page 5
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
Cabinet Layout
24.00
REF.
61
22.00
REF.
55.9
2.92
7.4
6.48
16.5
2.81
7.1
4.30
10.9
16.50
41.9
12.50
31.8
22.00
55.9
27.00
[68.6]
22.70
57.7
FRONT VIEW
24.00
61
LEFT SIDE VIEW
1.59
4
1.85
4.7
14.36
36.5
16.86
42.8
18.81
47.8
21.81
55.4
12.00
30.5
BACK VIEW
5/8" O.D. REMOTE
SUCTION
CONNECTION
3/8" O.D. REMOTE
LIQUID LINE
CONNECTION
3/4" FPT DRAIN
3/8"FLARE
MACHINE
WATER INLET
120 VOLT CORD
ICE DROP
OPENING
PLAN VIEW
ULTRA SONIC
BIN LEVEL
SENSOR
OPTIONAL
24.00
REF.
61
22.00
REF.
55.9
2.92
7.4
6.48
16.5
2.81
7.1
4.30
10.9
16.50
41.9
12.50
31.8
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 6
Unpacking
Remove the carton from the skid. Check for hidden
freight damage, notify the carrier immediately if any is
found. Retain the carton for the carrier’s inspection.
The machine is not bolted to the skid. If strapped
remove the strap.
Place on Bin or Dispenser
If reusing an existing bin, be sure that the bin is in
good shape and that the gasket tape on the top is not
torn up. Water leaks, not covered by warranty, could
result from a poor sealing surface. Because this is a
remote low side, a new bin is recommended due to
the high cost to the user of replacing an old bin when
a remote system is on top.
Install the correct adapter, following the directions
supplied with that adapter.
Hoist the machine onto the adapter.
Note: The machine is heavy! Use of a mechanical lift
is recommended.
Position the machine on the bin or adapter. Secure
with straps from the hardware bag packed with the
machine, or those supplied with the adapter.
Remove any plastic covering the stainless steel
panels.
Remove any packaging, such as tape or foam blocks,
that may be near the gear reducer or ice chute.
Level the bin and ice machine front to back and left to
right by using the bin leg levelers.
Panel Removal
1. Locate and loosen the two screws at the bottom
edge of the front panel.
2. Pull the front panel out at the bottom until it clears
the bin.
3. Lower the front panel down and o󰀨 the machine.
4. Remove two screws at the front of the top panel.
Lift up the front of the top panel, push the top panel
back an inch, then lift to remove.
5. Locate and loosen the screw holding each side
panel to the base. Left side panel also has a screw
holding it to the control box.
6. Pull the side panel forward to release it from the
back panel.
background
August 2026
Page 7
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
Water
The water supply for ice making must be cold, potable
water. There is a single 3/8” male are potable water
connection on the back panel.
Backow
The design of the oat valve and reservoir prevents
potable water backow by means of a 1" air gap
between the reservoir's maximum water level and the
oat valve water inlet orice.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet.
Tubing
Connect the potable water
supply to the potable water
tting, 3/8” OD copper tubing or
the equivalent is recommended.
Connect the drain tube to the
condensate drain tting. Vent this
drain tube.
Do not Tee ice machine drains
into the drain tube from the ice
storage bin or dispenser. Back
ups could contaminate and
/ or melt the ice in the bin or
dispenser.
Follow all local and national
codes for tubing, traps and air
gaps.
Potable Water Inlet
Condensate Drain
CONNECTION
TO POTABLE
WATER SUPPLY
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
September 2026
Page 8
Electrical
The machine includes a power cord, connect
to the proper power supply. A separate circuit is
recommended to avoid unintended shut downs.
If a dedicated condensing unit is connected to this
machine, it will have a separate power supply.
Do not use an extension cord.
Follow all local and national codes.
Model Dimensions
w" x d" x h"
Voltage
Volts/Hz/Phase
Min Circuit Ampacity Max Fuse Size
(cord connected)
All 22 x 24 x 27 115/60/1 2.9 15
3/8 OD Liquid Line Stub
5/8 OD Suction
Line Stub
Power Cord
Note: If the supply cord is damaged, it must
be replaced by Scotsman, its service agent, or
similarly qualied persons in order to avoid a
hazard.
background
August 2026
Page 9
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
Refrigeration
BTUH Capacity Requirements
Model BTUH
NS0922LX, NH0922LX, & FS1222LX 5,000
NS1322LX, NH1322LX, & FS1522LX 7,200
Remote low side models require connection to a
dedicated condensing unit or a rack system.
Recommended Tubing from Head to Condensing Unit
• Suction Line: 5/8" OD
• Liquid Line: 3/8" OD
Distance limits
• Maximum distance between dedicated condensing
unit and head: 75 feet.
• Condensing Unit Elevation over Ice Making
Section: 35 feet.
Note: Elevations greater than 20 feet require
installation of a suction line trap at the 10 foot mark.
Ice Making Section
• Elevation over Condensing Unit: 15 feet.
Line Routing:
• Allowed: One rise after a drop.
• Allowed: One drop after a rise.
• Not Allowed: More than one rise after a drop
• Not Allowed: More than one drop after a rise
Roof Attachment
Install and attach the remote condensing unit to the
roof of the building, using the methods and practices
of construction that conform to the local building
codes, including having a roong contractor secure
the condenser to the roof.
Refrigeration Installation:
Connections: The liquid and suction ttings on the
back of the cabinet are stubs. The liquid line size is
3/8" OD. The suction line size is 5/8" OD.
1. On R-449A models recover the R-449A holding
charge
2. Cut the stubs o󰀨.
3. Braze line set tubing to each tting. Sweep with
dry nitrogen while brazing.
4. Dedicated condensing unit: Evacuate complete
system to 50 microns.
5. Open the ball valves.
Rack: The skills of a refrigeration technician are
required to connect the ice machine to the building’s
refrigeration system.
Notes:
• R-449A models: 10 ounces of R-449A refrigerant
is in the system as a holding charge.
• Be sure the liquid connection is NOT in series with
another liquid line valve.
• Local Codes must be observed.
• Note: All site made joints in HERMETICALLY
SEALED SYSTEMS shall be tested for leaks at
a pressure of at least 0.25 x maximum allowable
pressure using detection equipment with a
sensitivity of at least 3g/year of refrigerant.
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 10
Final Check List
After connections
1. Wash out the bin. If desired, the interior of the bin
could be sanitized.
2. Locate the ice scoop (if supplied) and have it
available for use when needed.
3. Remote only: Switch on the electrical power to
warm up the compressor. Do not start the machine
for 4 hours.
Final Check List
1. Is the unit located indoors in a controlled
environment?
2. Is the unit located where it can receive adequate
cooling air?
3. Has the correct electrical power been supplied to
the machine?
4. Have all the water supply connections been
made?
5. Have all the drain connections been made?
6. Has the unit been leveled?
7. Have all unpacking materials and tape been
removed?
8. Has the protective covering on the exterior panels
been removed?
9. Is the water pressure adequate?
10. Have the drain connections been checked for
leaks?
11. Has the bin interior been wiped clean or sanitized?
12. Have any water lter cartridges been replaced?
13. Have all required kits and adapters been properly
installed?
14. Has the ice machine been properly connected to
the condensing unit or rack?
Control and Machine Operation
Once started, the ice machine will automatically make
ice until the bin or dispenser is full of ice. When ice
level drops, the ice machine will resume making ice.
Caution: Do not place anything on top of the ice
machine, including the ice scoop. Debris and moisture
from objects on top of the machine can work their way
into the cabinet and cause serious damage. Damage
caused by foreign material is not covered by warranty.
There are four indicator lights at the front of the
machine that provide information on the condition of
the machine: Power, Status, Water, De-scale &
Sanitize.
Power
Status
No Water
Time to Clean
On
O󰀨
Note: If the De-Scale & Sanitize light is ON, following
the cleaning process will clear the light for another
cleaning time internal.
Two button switches are at the front – On and O󰀨. To
switch the machine OFF, push and release the O󰀨
button. The machine will shut o󰀨 at the end of the next
cycle. To switch the machine ON, push and release
the On button. The machine will go through a start up
process and then resume ice making.
Lower Light and Switch Panel
This user accessible panel provides important
operational information and duplicates the lights and
switches on the controller. It also allows access to the
On and O󰀨 buttons that operate the ice machine.
Sometimes access to the switches should be limited
to prevent unauthorized operation. For that purpose a
xed panel is shipped in the hardware package. The
xed panel cannot be opened.
To install the xed panel:
1. Remove the front panel and remove the bezel.
2. Spread the bezel frame open and remove original
door, insert xed panel into bezel. Be sure it is in
the closed position.
3. Return bezel to panel and install panel on unit.
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
September 2026
Page 11
Initial Start Up
1. Turn the water supply on.
2. Switch the electrical power on. Conrm voltage is
correct for the model.
3. Push and release the On button. The machine will
start up in about two minutes.
The liquid line valve will open and liquid refrigerant
will ow into the machine. For the units connected to
a dedicated condensing unit, the resulting increase in
suction pressure will start the condensing unit and the
condensing unit will begin discharging warm air from
the remote condenser. After about 5 minutes, ice will
begin to drop into the bin or dispenser.
4. Check the machine for unusual rattles.
5. Tighten any loose screws, be sure no wires are
rubbing moving parts. Check for tubes that rub.
6. Check suction pressure and adjust the EPR
setting for optimum performance.
Note: As shipped the EPR valve should maintain low
side pressure at about 36 PSIG + or - 2 PSIG.
7. Check superheat and if needed adjust to 12
o
F, +
or - a few degrees
Note: Machines will operate and make ice at the
factory EPR setting for optimum performance, adjust
the EPR to the settings in the chart below:
Model Number Ice Head EPR
Setting
Superheat
Setting
NS0922LX
NH0922LX
FS1222LX
30 PSIG
12
o
F, + or - a
few degrees
NS1322LX
NH1322LX
FS1522LX
26 PSIG
12
o
F, + or - a
few degrees
8. Fill out the warranty registration form and either
le it on line or mail it.
9. Notify the user of the maintenance requirements
and whom to call for service.
Maintenance
This ice machine needs ve types of maintenance:
• Remote condensing units need their condenser coils
cleaned regularly.
• All models require regular scale removal
• All models require regular sanitization.
• All models require sensor cleaning.
• All models require a top bearing check.
Maintenance Frequency
Scale removal. To maintain proper machine
performance and sanitary condition, cleaning is
recommended every 6 months. The ice machine
will not maintain a sanitary condition without human
intervention.
The yellow Descale & Sanitize light will switch on
after a set period of 6 months as a reminder to
clean the machine. Some water quality conditions
may necessitate cleanings as frequently as every 3
months.
Sanitizing: Every time the scale is removed or as
often as needed to maintain a sanitary unit.
Sensor Cleaning: Every time the scale is removed.
Top bearing check: At least twice a year or every
time the scale is removed. During the course of
normal operation, some material buildup on top of the
bearing is normal and should be wiped away during
maintenance.
Maintenance: Remote Air Cooled Condenser
The condenser ns will occasionally need to be
cleaned of leaves, grease or other dirt. Check the coil
every time the ice machine is cleaned.
Maintenance: Exterior Panels
The front and side panels are durable stainless steel.
Fingerprints, dust and grease will require cleaning
with a good quality stainless steel cleaner
Note: If using a sanitizer or a cleaner that contains
chlorine on the panels, after use be sure to wash the
panels with clean water to remove chlorine residue.
Maintenance: Water Filters
If the machine has been connected to water lters,
check the cartridges for the date they were replaced
or for the pressure on the gauge. Change cartridges
if they’ve been installed more than 6 months or if the
pressure drops too much during ice making.
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 12
Maintenance: Scale Removal and Sanitation
Note: Following this procedure will reset the de-scale
and sanitize light.
Preparing to Clean:
1. Remove both the front and right panels.
2. Push and release the OFF button.
3. Remove ice from bin or dispenser.
4. Remove the ice chute cover.
5. Remove the water reservoir cover.
6. Turn the water supply to the oat valve o󰀨 by turn-
ing the knob 1/4 turn CCW.
7. Drain the water reservoir and evaporator into a
bucket using the vent tube. Return the vent tube to
it’s original collar bracket.
8. Using a small cup for precise pouring, add hot
(100-120°F) water into the reservoir until water
comes out of the top of the evaporator at the ex-
truder, about 1qt (varies slightly by model).
9. Let hot water warm evaporator for 2-5 minutes and
then drain the system (refer to step 7)
10. Loosen the thumb screw and raise the water res-
ervoir from the “Make Ice” position to the “Clean”
position.
Scale Removal:
11. Prepare a solution of 16oz. Scotsman Clear One
scale remover and 16oz. 95-115 °F. potable water.
12. Using a small cup for precise pouring, add the
scale remover solution into the reservoir until the
solution comes out of top of the evaporator at the
extruder, about 1qt (varies slightly by model).
13. Push and release the Clean button: C is displayed
and the Time to Clean light blinks. The auger will
turn and circulate the scale remover for 30 min-
utes before shutting o󰀨. No ice is made during the
cleaning cycle.
14. Lower the water reservoir back to the “Make Ice”
position. Drain the water reservoir and evaporator
into a bucket using the vent tube.
15. Perform a rinse of the system: turn the water sup-
ply to the oat valve back on and allow the evapo-
rator to ll. Once full, turn the water supply at the
oat valve o󰀨 and drain the system using the vent
tube. Return the vent tube to it’s original collar
bracket.
Sanitize:
16. Loosen the thumb screw and raise the water res-
ervoir from the “Make Ice” position to the “Clean”
position.
17. Prepare a solution of sanitizer. Mix 4 oz. of Nu-
Calgon IMS and 2.5 gallons of 95-115 °F. potable
water to create a 200 ppm solution.
18. Using a small cup for precise pouring, add the
sanitizer solution into the reservoir until the solu-
tion comes out of top of the evaporator at the
extruder, about 1qt (varies slightly by model).
Reserve any excess sanitizer.
19. Allow the sanitizer to soak while steps 20-24 are
completed, or at least 60 seconds.
Continued on next page:
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner
comes in contact with
skin, ush with water. if
swallowed, do NOT induce
vomiting.
Give large amounts of
water or milk. Call Physician
immediately. Keep out of the
reach of children.
background
August 2026
Page 13
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
Maintenance: Scale Removal and Sanitation Continued
Remove Internal Parts for Cleaning:
20. Remove the ice sweep, upper ice chute, lower
ice chute, and bin eyes for additional cleaning.
The reservoir cover and chute cover were already
removed and should also be cleaned.
21. Prepare a solution of 4oz. Scotsman Clear One
scale remover and 16oz. 95-115 °F. potable water.
Using a nylon brush, scrub each part with scale
remover and rinse, excluding the bin eyes.
22. Using the leftover sanitizing solution and a nylon
brush, scrub each part, excluding the bin eyes.
23. Gently wipe down the bin eyes with scale remover,
rinse, and dry thoroughly (important).
24. Return all parts to their original position.
Note: Eye holders must be mounted properly. They
snap into a centered position and are properly located
when the wires are routed to the back and the left eye
is the one with 2 wires at the connector.
Finish Cleaning Process:
25. Lower the water reservoir back to the “Make Ice”
position. Drain the water reservoir and evaporator
into a bucket using the vent tube.
26. Perform a rinse of the system: turn the water sup-
ply to the oat valve back on and allow the evapo-
rator to ll. Once full, turn the water supply at the
oat valve o󰀨 and drain the system using the vent
tube. Return the vent tube to it’s original collar
bracket.
27. Switch the water supply to the ice machine on and
check for leaks as the system lls.
28. Push and release the ON button.
29. Allow the unit to make ice for at least 5 minutes
while washing the inside of the ice storage bin with
sanitizing solution. Discard or melt all ice made
during this step.
30. Return the right and front panels to their original
position and secure with the original screws.
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 14
Options
Vari-Smart
Optional adjustable ice level control (KVS). When
this option is present there is an adjustment post and
an additional indicator light to the right of the four
indicator lights mentioned earlier.
The ultrasonic ice level control allows the user to
control the point that the ice machine will stop making
ice before the bin or dispenser is full.
Reasons for this include:
• Seasonal changes in ice used
• Planning to sanitize the bin
• Faster turnover for fresher ice
• Certain dispenser applications where maximum ice
level is not desired
Use of adjustable ice level control
There are several positions the ice level can be set to,
including O󰀨 or Max (knob and label indicators lined
up), where it lls the bin until the standard bin control
shuts the machine o󰀨. See the kit’s instructions for
complete details including special instructions for
dispenser applications.
Rotate the adjustment post to the desired ice level.
The machine will ll up to that level and when it shuts
o󰀨 the indicator light next to the adjustment post will
be On.
Note: The maximum ll position is when the arrow on
the knob points to the arrow on the label.
background
August 2026
Page 15
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
What to Do Before Calling for Service
Normal Operation
Ice
The machine will make either aked or nugget ice,
depending upon the model. The ice will be produced
continuously until the bin is full. It is normal for a few
drops of water to occasionally fall with the ice.
Heat
On remote models most heat is exhausted at the
remote condenser, the ice machine should not
generate signicant heat. Water cooled models
also put most of the heat from ice making into the
discharge water. Air cooled models will generate heat,
and it will be discharged into the room.
Noise
The ice machine will make noise when it is in ice
making mode. The compressor and gear reducer will
produce sound. Air cooled models will add fan noise.
Some ice making noise could also occur. These
noises are all normal for this machine.
Reasons the machine might shut itself o󰀨:
• Lack of water.
• Does not make ice
• Auger motor overload
• High discharge pressure.
• Low refrigeration system pressure.
Check the following:
1. Has the water supply to the ice machine or
building been shut o󰀨? If yes, the ice machine will
automatically restart within minutes after water begins
to ow to it.
2. Has power been shut o󰀨 to the ice machine? If yes,
the ice machine will automatically restart when power
is restored.
3. Has someone shut the power o󰀨 to the remote
condenser while the ice machine still had power? If
yes, the ice machine may need to be manually reset.
Manually Resetting the Machine
• Open the switch door
• Push and release the O󰀨 button.
• Push and release the On button.
To Shut the Machine O󰀨:
Push and hold the O󰀨 button for 3 seconds or until the
machine stops.
Indicator Lights & Their Meanings
Power Status Water De-Scale &
Sanitize
Steady Green Normal Normal - -
Blinking Green Self Test Failure Switching on or
o󰀨. When Smart-
Board used,
machine attention
recommended.
- -
Blinking Red - Diagnostic shut
down
Lack of water -
Yellow - - - Time to descale and
sanitize
Blinking Yellow - - - In Cleaning Mode
Light O󰀨 No power Switched to O󰀨 Normal Normal
Open Switch Door
background
NS0922LX, NH0922LX, NS1322LX, NH1322LX, FS1222LX, FS1522LX
Remote Low Side User Manual
August 2026
Page 16
Service Diagnosis
Symptom Probable Cause Possible Correction
No ice No power Check that ice machine and
condensing unit, if used, both have
power. If power light is out, check
transformer.
Code 3: No water Restore water
Status light is o󰀨 Push and release ON switch
Code 1: No ice sensed Check for ice ow down chute. if
very slow or no ice being made,
check water inlet tubing for
restriction; check for condensing
unit or refrigeration system failure
Check auger motor for power, if no
power, check controller component
indicator light. If there is power to
the motor, check motor windings
Code 2: Auger motor draws too
many amps, controller shuts unit
o󰀨.
Check that liquid line valve shuts
o󰀨 tightly
Check for damage to gear reducer
or auger bearings.
Bin Eyes Blocked light is On Ice is in the chute.
No ice in the chute. Check position
of sensors, check sensors for scale
build up
Everything is in operation, but no
refrigeration e󰀨ect
Check liquid line valve
Check condensing unit
Check TXV
Check refrigerant charge
Low ice making capacity Scale build up Remove scale from evaporator and
water system
Restricted water supply to
evaporator
Squeeze hose, if bubbles appear
revise hose and reservoir
Suction tubing kinked Check suction tubing
Expansion valve superheat
incorrect
Check superheat
background
SCOTSMAN ICE SYSTEMS
101 Corporate Woods Parkway
Vernon Hills, IL 60061
800-726-8762
www.scotsman-ice.com
17-3953-01 Rev.B

Specifications

Scotsman FS1222LX Questions and Answers

Questions and Answers

Related Products

No image
Scotsman Fs2330x
2026-09-22 2 docs
No image
Scotsman Ns2030x
2026-09-22 3 docs
No image
Scotsman Nh2030x
2026-09-22 3 docs