Inverter Split Unit Air Conditioner
Wall Mounted FTKF-A & FTXF-A Series
[60Hz]
[Applied Models]
Inverter Split : Cooling Unit
Heat Pump Unit
CVR DAMA-SM-23-021 FTKF-A and FTXF-A Series.indd 1CVR DAMA-SM-23-021 FTKF-A and FTXF-A Series.indd 1 27/2/2024 4:39:27 PM27/2/2024 4:39:27 PM
background
DAMA-SM-23-021
i Table of Contents
Introduction .................................................................................... 1
1. Safety Cautions.......................................................................................2
1.1 Warnings and Cautions Regarding Safety of Workers.............................2
1.2 Warnings and Cautions Regarding Safety of Users.................................8
2. Icons Used ............................................................................................10
3. Revision History ....................................................................................11
Part 1 General Information .......................................................... 12
1. Applicable Models .................................................................................13
Part 2 Specifications....................................................................15
1. Specification Data .................................................................................16
2. Functions...............................................................................................22
Part 3 Functions and Control ....................................................... 23
1. Main Functions......................................................................................24
1.1 Temperature Control ..............................................................................24
1.2 Frequency Control..................................................................................24
1.3 Airflow Direction Control.........................................................................26
1.4 Fan Speed Control for Indoor Unit .........................................................26
1.5 Dry Mode................................................................................................27
1.6 Automatic Operation...............................................................................28
1.7 Thermostat Control.................................................................................29
1.8 ECO+ Operation.....................................................................................30
1.9 Sleep Mode ............................................................................................31
1.10 POWERFUL Operation ..........................................................................31
1.11 Other Functions......................................................................................32
2. Thermistor Functions ............................................................................33
3. Control Specification .............................................................................34
3.1 Mode Hierarchy ......................................................................................34
3.2 Frequency Control..................................................................................35
3.3 Standby Electricity Saving (Suspend Function) .....................................37
3.4 Controls at Mode Changing/Start-up......................................................37
3.5 Discharge Pipe Temperature Control.....................................................39
3.6 Input Current Control..............................................................................40
3.7 Freeze-up Protection Control .................................................................41
3.8 Heating Peak-cut Control .......................................................................42
3.9 Outdoor Fan Control...............................................................................43
3.10 Liquid Compression Protection Function................................................44
3.11 Defrost Control .......................................................................................44
3.12 Electronic Expansion Valve Control .......................................................45
3.13 Malfunctions ...........................................................................................49
background
DAMA-SM-23-021
Table of Contents ii
Part 4 Remote Controller ............................................................. 50
1. Applicable Remote Controller ...............................................................51
2. BRC52B63/64 .......................................................................................52
Part 5 Service Diagnosis .............................................................. 53
1. General Problem Symptoms and Check Items .....................................54
2. Troubleshooting with LED .....................................................................55
2.1 Indoor Unit..............................................................................................55
2.2 Outdoor Unit ...........................................................................................55
3. Error Diagnosis .....................................................................................56
3.1 To enter error diagnosis .........................................................................56
4. Troubleshooting ....................................................................................57
4.1 Error Codes and Description ..................................................................57
4.2 Indoor Unit PCB Abnormality .................................................................59
4.3 Freeze-up Protection Control .................................................................60
4.4 Indoor Fan Motor (DC Motor) or Related Abnormality ...........................61
4.5 Thermistor or Related Abnormality (Indoor Unit)....................................62
4.6 Thermistor or Related Abnormality (Indoor Unit)....................................63
4.7 Low-voltage Detection or Over-voltage Detection..................................65
4.8 Signal Transmission Error (Between Indoor Unit and Outdoor Unit)......67
4.9 Installation error......................................................................................70
4.10 Outdoor Unit PCB Abnormality...............................................................73
4.11 Actuation of High Pressure Switch .........................................................74
4.12 OL Activation (Compressor Overload) ...................................................75
4.13 OL Activation (Compressor Overload) or HPS Activation (High Pressure
Switch)....................................................................................................... 77
4.14 Compressor Lock ...................................................................................79
4.15 DC Fan Lock ..........................................................................................80
4.16 Input Overcurrent Detection ...................................................................81
4.17 Discharge Pipe Temperature Control.....................................................82
4.18 High Pressure Control in Cooling ...........................................................83
4.19 Compressor System Sensor Abnormality ..............................................85
4.20 Position Sensor Abnormality ..................................................................86
4.21 Thermistor or Related Abnormality (Outdoor Unit).................................87
4.22 Electrical Box Temperature Rise............................................................89
4.23 Radiation Fin Temperature Rise ............................................................90
4.24 Output Overcurrent Detection ................................................................92
4.25 Four Way Valve Abnormality..................................................................94
5. Actuator Check......................................................................................96
5.1 Thermistor Resistance Check ................................................................96
5.2 Power Supply Waveform Check.............................................................97
5.3 Electronic Expansion Valve Check.........................................................97
5.4 Four Way Valve Performance Check .....................................................98
5.5 Inverter Unit Refrigerant System Check.................................................99
5.6 Rotation Pulse Check on the Outdoor Unit PCB ....................................99
5.7 Installation Condition Check.................................................................101
5.8 Discharge Pressure Check...................................................................101
5.9 Outdoor Fan System Check .................................................................102
5.10 Main Circuit Short Check......................................................................102
5.11 Power Module Check ...........................................................................104
background
DAMA-SM-23-021
iii Table of Contents
Part 6 Trial Operation and Field Settings .................................. 105
1. Pump Down Operation........................................................................106
2. Forced Cooling Operation ...................................................................107
3. Silicone Grease on Power Transistor/Diode Bridge............................108
Part 7 Appendix .......................................................................... 109
1. Piping Diagrams..................................................................................110
1.1 Indoor Unit............................................................................................110
1.2 Outdoor Unit .........................................................................................112
2. Wiring Diagrams..................................................................................114
2.1 Indoor Unit............................................................................................114
2.2 Outdoor Unit .........................................................................................115
2.3 Printed Circuit Board Connector Wiring Diagram.................................116
2.4 Printed Circuit Board Connector Wiring Diagram.................................117
3. Operation Limit....................................................................................119
background
DAMA-SM-23-021
Introduction 1
1. Safety Cautions.......................................................................................2
1.1 Warnings and Cautions Regarding Safety of Workers.............................2
1.2 Warnings and Cautions Regarding Safety of Users.................................8
2. Icons Used ............................................................................................10
3. Revision History ....................................................................................11
Introduction
background
Safety Cautions DAMA-SM-23-021
2 Introduction
1. Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
After the repair work is complete, be sure to conduct a test operation to ensure that the
equipment operates normally, and explain the cautions for operating the product to the
customer.
Caution Items The caution items are classified into Warning and Caution. The Warning items are
especially important since death or serious injury can result if they are not followed closely. The
Caution items can also lead to serious accidents under some conditions if they are not
followed. Therefore, be sure to observe all the safety caution items described below.
Pictograms This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates a prohibited action.
The prohibited item or action is shown in the illustration or near the symbol.
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown in the illustration or near the symbol.
1.1 Warnings and Cautions Regarding Safety of Workers
This manual is for the
person in charge of
maintenance and
inspection.
This appliance is
filled with R32.
Warning
Do not store equipment in a room with fire sources (e.g., naked
flames, gas appliances, electric heaters).
Be sure to disconnect the power cable from the socket before
disassembling equipment for repair.
Working on equipment that is connected to the power supply may cause
an electrical shock.
If it is necessary to supply power to the equipment to conduct the repair or
inspect the circuits, do not touch any electrically charged sections of the
equipment.
If refrigerant gas is discharged during repair work, do not touch the
discharged refrigerant gas.
Refrigerant gas may cause frostbite.
When disconnecting the suction or discharge pipe of the
compressor at the welded section, evacuate the refrigerant gas
completely at a well-ventilated place first.
If there is gas remaining inside the compressor, the refrigerant gas or
refrigerating machine oil discharges when the pipe is disconnected, and it
may cause injury.
If refrigerant gas leaks during repair work, ventilate the area.
Refrigerant gas may generate toxic gases when it contacts flames.
Be sure to discharge the capacitor completely before conducting
repair work.
The step-up capacitor supplies high-voltage electricity to the electrical
components of the outdoor unit.
A charged capacitor may cause an electrical shock.
background
DAMA-SM-23-021 Safety Cautions
Introduction 3
Do not turn the air conditioner on or off by plugging in or
unplugging the power cable.
Plugging in or unplugging the power cable to operate the equipment may
cause an electrical shock or fire.
Be sure to wear a safety helmet, gloves, and a safety belt when
working in a high place (more than 2 m).
Insufficient safety measures may cause a fall.
In case of R-32 / R410A refrigerant models, be sure to use pipes,
flare nuts and tools intended for the exclusive use with the R-32 /
R410A refrigerant.
The use of materials for R-22 refrigerant models may cause a serious
accident, such as a damage of refrigerant cycle or equipment failure.
Do not mix air or gas other than the specified refrigerant (R-32 /
R410A / R-22) in the refrigerant system.
If air enters the refrigerant system, an excessively high pressure results,
causing equipment damage and injury.
Caution
Do not repair electrical components with wet hands.
Working on the equipment with wet hands may cause an electrical shock.
Do not clean the air conditioner with water.
Washing the unit with water may cause an electrical shock.
Be sure to provide an earth / grounding when repairing the
equipment in a humid or wet place, to avoid electrical shocks.
Be sure to turn off the power switch and unplug the power cable
when cleaning the equipment.
The internal fan rotates at a high speed, and may cause injury.
Be sure to conduct repair work with appropriate tools.
The use of inappropriate tools may cause injury.
Be sure to check that the refrigerating cycle section has cooled
down enough before conducting repair work.
Working on the unit when the refrigerating cycle section is hot may cause
burns.
Conduct welding work in a well-ventilated place.
Using the welder in an enclosed room may cause oxygen deficiency.
Warning
background
Safety Cautions DAMA-SM-23-021
4 Introduction
Safety Checklist
Checking the area
Before beginning work, conduct safety checks to minimise the risk of ignition. When
repairing the refrigerating system, take the following precautions before work.
Work procedure
Work shall be conducted under a controlled procedure so as to minimise the risk of working
in the presence of R32 or vapour.
General working area
All maintenance staff and others working in the local area shall be instructed on the nature of
work being carried out.
Work in confined spaces shall be avoided.
The area around the workspace shall be sectioned off. Ensure that the conditions within the
area have been made safe by control of flammable materials.
Checking for presence of refrigerant
The working area shall be checked with an appropriate refrigerant detector before and
during work, to ensure the technician is aware of potentially flammable atmospheres.
Ensure that the leak detection equipment being used is suitable for use with R32, i.e.
non-sparking, adequately sealed or intrinsically safe.
Fire extinguishing equipment
If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be made available at hand. Prepare a dry
powder or CO
2
fire extinguisher adjacent to the working area.
No ignition sources
During work on a refrigeration system which involves exposing any piping work that contains
or has contained R32, any sources of ignition shall not be used in a manner that may lead to
the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should
be kept at a safe distance from the site of installation, repairing, or removing space. Before
starting work, the area around the equipment shall be examined to make sure that there are
no flammable hazard or ignition risks. No Smoking signs shall be displayed.
Ventilated area
Ensure that the working area is open or that it is adequately ventilated before work.
Adequate ventilation shall be maintained during the entire period of work.
The ventilation should disperse any released refrigerant and preferably discharge it into the
external atmosphere.
Checking the refrigeration equipment
Where electrical components are to be changed, the new components shall be fit for the
purpose and have the correct specifications.
The manufacturer's maintenance and service guidelines shall be followed at all times.
If there are any unclear points, consult the manufacturer's technical department for
assistance.
The following checks shall be applied to any installation work involving R32:
The amount of charge is in accordance with the size of the room where the refrigerant
containing parts are installed;
The ventilation machinery and outlets are operating adequately and are not obstructed;
If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for
the presence of refrigerant;
Marking on the equipment is visible and legible. Markings and signs that are illegible
shall be corrected;
Refrigeration pipes or components are installed in a position where they are unlikely to
be exposed to any substance which may corrode refrigerant containing components, or
the refrigerant containing components are constructed of materials which are inherently
resistant to corrosion or are suitably protected against corrosion.
background
DAMA-SM-23-021 Safety Cautions
Introduction 5
Safety Checklist (con't)
Checking electrical devices
Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. In case there is any fault that could endanger safety, no
electrical supply shall be connected to the circuit until the fault is satisfactorily dealt with.
Initial safety checks shall include:
that capacitors are discharged: this shall be done in a safe manner to avoid possibility of
sparking;
that no live electrical components and wiring are exposed while charging, recovering or
purging the system;
that the equipment is earthed at all times.
Repairs to sealed components
During repairs to sealed components, all electrical supplies shall be disconnected from the
equipment being worked upon before the removal of any sealed covers, etc. If it is absolutely
necessary to have power supplied to equipment during servicing, continuously operating
leak detection shall be installed at the most dangerous point of the system in order to warn of
a potentially hazardous situation.
Particular attention shall be paid to the following: ensure that working on electrical
components does not alter the casing in such a way that affects the level of protection
including damage to cables, excessive number of connections, terminals different from the
original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that the equipment is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no longer serve the
purpose of preventing the ingression of flammable atmospheres. Replacement parts shall be
in accordance with the manufacturer's specifications.
The use of silicon sealant may inhibit the effectiveness of some types of leak detection
equipment. Intrinsically safe components do not have to be isolated before working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance load to the circuit without ensuring that
this will not exceed the permissible voltage and current for the equipment in use.
Only intrinsically safe components can be worked on in the presence of a flammable
atmosphere.
The test apparatus shall be of correct rating.
Replace components only with parts specified by the manufacturer. Using other parts may
result in ignition of the refrigerant leaked into the atmosphere.
Wiring
Check that wiring is not subject to wear, corrosion, excessive pressure, vibration, sharp
edges or any other adverse environmental effects. The check shall also take into account
the effects of ageing or continuous vibration from sources such as compressors or fans.
Detecting of R32
Under no circumstances shall potential sources of ignition be used in the search for or
detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall
not be used.
background
Safety Cautions DAMA-SM-23-021
6 Introduction
Safety Checklist (con't)
Leak detection methods
The following leak detection methods can be applied for systems containing R32.
Electronic leak detectors shall be used to detect R32, but the sensitivity may not be
adequate or may need re-calibration (detection equipment shall be calibrated in a
refrigerant-free area). Ensure that the detector is not a potential source of ignition and that it
is suitable for the refrigerant used. Leak detection equipment shall be set to the percentage
of the lower flammability limit (LFL) of the refrigerant and calibrated to fit the refrigerant
employed. The appropriate percentage of gas (maximum 25%) shall be confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents
containing chlorine shall be avoided as the chlorine may react with the refrigerant and
corrode the copper piping work.
If a leak is suspected, all naked flames shall be removed or extinguished.
If a refrigerant leakage which requires brazing is found, all of the refrigerant shall be
recovered from the system, or isolated (by means of shut off valves) in a part of the system
remote from the point of the leakage. Oxygen free nitrogen (OFN) shall then be purged
through the system both before and during the brazing process.
Removal and evacuation
When breaking the refrigerant circuit to make repairs or any other purpose, conventional
procedures may be used. However, flammability must be taken into consideration. The
following procedure shall be adhered to:
Remove refrigerant;
Purge the circuit with inert gas;
Evacuate the inert gas;
Purge again with inert gas;
Carry out cutting or brazing of the circuit.
The refrigerant shall be recovered into the correct recovery cylinders. The system shall be
cleaned with OFN to render the unit safe. (= Flushing) This process may need to be
repeated several times. Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved through breaking the vacuum by filling the system with OFN until
the working pressure is achieved, then venting the OFN into the atmosphere, and finally
pulling the system down to vacuum again. This process shall be repeated until no refrigerant
remains within the system. After the last OFN charge is finished, the system shall be vented
down to atmospheric pressure to enable work. This operation is especially important if
brazing operations on the piping work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and that
there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements shall be met.
Ensure that the charging equipment to be used is not contaminated by different refrigerants.
Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained
in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed before charging the system with
refrigerant.
Label the system when charging is complete (if not already).
Extreme care shall be taken not to overfill the refrigeration system.
Before recharging, the system shall be tested for leakage with OFN. On completion of
charging, the system shall be tested before commissioning. Follow up leakage test shall be
carried out before leaving the site.
background
DAMA-SM-23-021 Safety Cautions
Introduction 7
Safety Checklist (con't)
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar
with the equipment and all its details. It is recommended to train technicians so that all of the
refrigerant is recovered safely. In case analysis is required before re-using the reclaimed
refrigerant, an oil and refrigerant sample shall be taken before proceeding with
decommissioning. It is essential that electrical power is available before work.
(1) Comprehend the equipment and its operation.
(2) Isolate the system electrically.
(3) Before starting work, ensure that:
mechanical handling equipment is available if required, for handling refrigerant
cylinders;
protective equipment can be used in compliance with specifications;
the recovery process is supervised by a competent person at all times;
recovery equipment and cylinders conform to the appropriate standards.
(4) Pump down the refrigerant system, if possible.
(5) If vacuum can not be ensured, apply a manifold so that refrigerant can be removed from
various parts of the system.
(6) Make sure that the cylinder is situated on the scale before recovery takes place.
(7) Start the refrigerant recovery device and operate it in accordance with the manufacturer's
instructions.
(8) Do not overfill cylinders. (Do not exceed 80% liquid charge volume).
(9) Do not exceed the maximum working pressure of the cylinder, even temporarily.
(10)When the cylinders have been filled correctly and the process is completed, make sure
that the cylinders and the equipment are removed from site promptly and all valves on
the equipment are closed.
(11)Recovered refrigerant shall not be charged into another refrigeration system before it
has been cleaned and checked.
Labelling
Equipment shall be labelled stating that it has been decommissioned and emptied of
refrigerant. The label shall be dated and signed. Ensure that there are labels on the
equipment stating the equipment contains R32.
Refrigerant recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is
recommended to conduct training so that all refrigerants can be removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery
cylinders are used.
Ensure that the correct number of cylinders for holding the total system charge are available.
All cylinders to be used must be designated for the recovered refrigerant and labelled for that
refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be equipped
with a pressure relief valve and associated shut-off valves in good working order. If possible,
empty recovery cylinders shall be cooled in a separate place before recovery is conducted.
The recovery equipment shall be in good working order with instructions concerning the
equipment at hand, and shall be suitable for the recovery of R32. In addition, a set of
calibrated weighing scales shall be available and in good working order. Hoses shall be
equipped with leak-free disconnect couplings and in good condition. Before using the
recovery device, check that it has undergone proper maintenance, that it is in satisfactory
working order, and that any associated electrical components are sealed to prevent ignition
in the event of a refrigerant leakage. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery
cylinder, with the relevant Waste Transfer Note attached. Do not mix refrigerants in recovery
units and especially not in cylinders.
If compressors or compressor oil are to be removed, ensure that the refrigerant melted into
the oil has been evacuated to an acceptable level to make certain that R32 does not remain
within the oil. The evacuation process shall be carried out before returning the compressor
to the supplier. Only electric heating to the compressor body shall be employed to accelerate
this process. Oil drained from the system shall be treated safely.
background
Safety Cautions DAMA-SM-23-021
8 Introduction
1.2 Warnings and Cautions Regarding Safety of Users
Warning
Do not store the equipment in a room with fire sources (e.g., naked
flames, gas appliances, electric heaters).
Be sure to use parts listed in the service parts list of the applicable
model and appropriate tools to conduct repair work. Never attempt
to modify the equipment.
The use of inappropriate parts or tools may cause an electrical shock,
excessive heat generation or fire.
If the power cable and lead wires are scratched or have deteriorated,
be sure to replace them.
Damaged cable and wires may cause an electrical shock, excessive heat
generation or fire.
Do not use a joined power cable or extension cable, or share the
same power outlet with other electrical appliances, since it may
cause an electrical shock, excessive heat generation or fire.
Be sure to use an exclusive power circuit for the equipment, and
follow the local technical standards related to the electrical
equipment, the internal wiring regulations, and the instruction
manual for installation when conducting electrical work.
Insufficient power circuit capacity and improper electrical work may cause
an electrical shock or fire.
Be sure to use the specified cable for wiring between the indoor and
outdoor units.
Make the connections securely and route the cable properly so that there
is no force pulling the cable at the connection terminals.
Improper connections may cause excessive heat generation or fire.
When wiring between the indoor and outdoor units, make sure that
the terminal cover does not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section may
cause an electrical shock, excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cables may cause an electrical shock or fire.
Placing heavy items on the power cable, or heating or pulling the power
cable may damage it.
Do not mix air or gas other than the specified refrigerant (R32 /
R410A / R22) in the refrigerant system.
If air enters the refrigerant system, an excessively high pressure results,
causing equipment damage and injury.
If the refrigerant gas leaks, be sure to locate the leaking point and
repair it before charging the refrigerant. After charging the
refrigerant, make sure that there is no leak.
If the leaking point cannot be located and the repair work must be
stopped, be sure to pump-down, and close the service valve, to prevent
refrigerant gas from leaking into the room. Refrigerant gas itself is
harmless, but it may generate toxic gases when it contacts flames, such
as those from fan type and other heaters, stoves and ranges.
When relocating the equipment, make sure that the new installation
site has sufficient strength to withstand the weight of the
equipment.
If the installation site does not have sufficient strength or the installation
work is not conducted securely, the equipment may fall and cause injury.
background
DAMA-SM-23-021 Safety Cautions
Introduction 9
Check to make sure that the power cable plug is not dirty or loose,
then insert the plug into a power outlet securely.
If the plug is dusty or has a loose connection, it may cause an electrical
shock or fire.
When replacing the coin battery in the remote controller, be sure to
dispose of the old battery to prevent children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
Caution
Installation of a leakage breaker is necessary in some cases
depending on the conditions of the installation site, to prevent
electrical shocks.
Do not install the equipment in a place where there is a possibility of
combustible gas leaks.
If combustible gas leaks and remains around the unit, it may cause a fire.
Check to see if parts and wires are mounted and connected
properly, and if connections at the soldered or crimped terminals
are secure.
Improper installation and connections may cause excessive heat
generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it.
A corroded installation platform or frame may cause the unit to fall,
resulting in injury.
Check the earth / grounding, and repair it if the equipment is not
properly earthed / grounded.
Improper earth / grounding may cause an electrical shock.
Be sure to measure insulation resistance after the repair, and make
sure that the resistance is 1 M or higher.
Faulty insulation may cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage may cause water to enter the room and wet the furniture
and floor.
Do not tilt the unit when removing it.
The water inside the unit may spill and wet the furniture and floor.
Warning
background
Icons Used DAMA-SM-23-021
10 Introduction
2. Icons Used
The following icons are used to attract the attention of the reader to specific information.
Icon Type of
Information
Description
Warning
Warning Warning is used when there is danger of personal injury.
Caution
Caution Caution is used when there is danger that the reader,
through incorrect manipulation, may damage equipment,
lose data, get an unexpected result or have to restart (part
of) a procedure.
Note
Note Note provides information that is not indispensable, but
may nevertheless be valuable to the reader, such as tips
and tricks.
Reference
Reference Reference guides the reader to other places in this binder
or in this manual, where he/she will find additional
information on a specific topic.
background
DAMA-SM-23-021 Revision History
Introduction 11
3. Revision History
Month/Year Version Revised contents
12/2023 DAMA-SM-23-021 First edition
background
DAMA-SM-23-021
12 Part 1 General Information
1. Applicable Models .................................................................................13
Part 1
General Information
background
DAMA-SM-23-021 Applicable Models
General Information 13
1. Applicable Models
Model Name and Power Supply
Mode Indoor Unit Outdoor Unit Power Supply
Cooling Only
FTKF09AXVJU RKF09AXVJU
1Phase, 208/230V, 60Hz
FTKF12AXVJU RKF12AXVJU
FTKF18AXVJU RKF18AXVJU
FTKF24AXVJU RKF24AXVJU
Heatpump
FTXF09AXVJU RXF09AXVJU
FTXF12AXVJU RXF12AXVJU
FTXF18AXVJU RXF18AXVJU
FTXF24AXVJU RXF24AXVJU
background
Applicable Models DAMA-SM-23-021
14 General Information
Nomenclature
Indoor Unit
Outdoor Unit
Remark:
*Capacity value under Nomenclature is an indication.
Please refer to Specifications for exact capacity value.
Definition Description
Unit Category F : Air-Cooled Split Indoor Unit
Product Type T : Wall Mounted
System
K
X
: Inverter, Cooling Only
: Inverter, Heatpump
Classification F : R32, Standard
Capacity Indication* 09 : 9,000 Btu/h
Major Design Category A : A Series
Factory Origin X : Malaysia
Power Supply VJ : 208/230V / 1Phase / 60Hz
Country U : United States
Definition
Description
Unit Category R : Air-Cooled Split Outdoor Unit
System
K
X
: Inverter, Cooling Only
: Inverter, Heatpump
Classification F : R32, Standard
Capacity Indication* 09 : 9,000 Btu/h
Major Design Category A : A Series
Factory Origin X : Malaysia
Power Supply VJ : 208/230V / 1Phase / 60Hz
Country U : United States
background
DAMA-SM-23-021
Part 2 Specifications 15
1. Specification Data .................................................................................16
2. Functions...............................................................................................22
Part 2
Specifications
background
Specification Data DAMA-SM-23-021
16 Specifications
1. Specification Data
Cooling Only
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTKF09A FTKF12A
OUTDOOR UNIT RKF09A RKF12A
Rated Capacity (Min. ~ Max.)
kW 2.64 (1.30 - 3.28) 3.52 (1.30 - 4.28)
Btu/h 9000 (4400 - 11200) 12000 (4400 - 14600)
Moisture Removal gal/h 0.05 0.16
Rated Running Current A 3.13 4.17
Rated Power Consumption W 720 960
EER2 Btu/h/W 12.5
SEER2 21.0
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 3/8” (9.52)
Refrigerant
Type R32
Charge lbs (kg) 1.65 (0.75)
Max. Interunit Piping Length ft (m) 65-5/8 (20)
Max. Interunit Height Difference ft (m) 49-1/4 (15)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTKF09A FTKF12A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 466 473
High CFM 431 436
Medium CFM 322 316
Low CFM 249 247
Quiet CFM 142 132
Sound Pressure Level (H/M/L/Q) dBA 44/37/30/19 46/38/32/19
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 22
Running Current (Rated) A 0.10
Power Consumption (Rated) W 29
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D) inch (mm) 12-3/8 x 32-11/16 x 14-1/16 (314 x 830 x 357)
Weight lbs (kg) 19.8 (9.0) 20.9 (9.5)
Gross Weight lbs (kg) 24.0 (10.9) 25.8 (11.7)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RKF09A RKF12A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1051
Sound Pressure Level dBA 46 49
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 24
Insulation Grade E
Running Current (Rated) A 0.61 0.61
Power Consumption (Rated) W 46 46
Motor Output W 26
Poles 8
Compressor
Type HERMETIC SWING
Model 1Y091BKCX1A#G
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 12.7 (375)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D) inch (mm) 24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weight lbs (kg) 60 (27)
Gross Weight lbs (kg) 66 (30)
Document No. 3D148691
COOLING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
OUTDOOR: 95°FDB (35°CDB)
background
DAMA-SM-23-021 Specification Data
Specifications 17
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTKF18A FTKF24A
OUTDOOR UNIT RKF18A RKF24A
Rated Capacity (Min. ~ Max.)
kW 5.30 (2.02 - 6.45) 6.57 (2.05 - 7.74)
Btu/h 18100 (6900 - 22000) 22400 (7000 - 26400)
Moisture Removal gal/h 0.61 0.88
Rated Running Current A 6.56 8.12
Rated Power Consumption W 1508 1867
EER2 Btu/h/W 12.0
SEER2 21.0
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 1/2” (12.70)
5/8” (15.88)
Refrigerant
Type R32
Charge lbs (kg) 3.31 (1.50)
Max. Interunit Piping Length ft (m) 98-1/2 (30)
Max. Interunit Height Difference ft (m) 65-5/8 (20)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTKF18A FTKF24A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 754
High CFM 716
Medium CFM 605
Low CFM 467
Quiet CFM 395
Sound Pressure Level (H/M/L/Q) dBA 49/44/38/33 53/45/39/34
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 39
Running Current (Rated) A 0.17
Power Consumption (Rated) W 54
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-11/16 x 39-9/16 x 10-3/4 (297 x 990 x 273)
Packaged Dimensions (H x W x D) inch (mm) 14-3/4 x 14-5/8 x 42-1/4 (375 x 371 x 1073)
Weight lbs (kg) 30.5 (13.8)
Gross Weight lbs (kg) 36 (16.5)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RKF18A RKF24A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1879
Sound Pressure Level dBA 54 55
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 23
Insulation Grade E
Running Current (Rated) A 1.30
Power Consumption (Rated) W 85 88
Motor Output W 55
Poles 8
Compressor
Type HERMETIC SWING
Model 2Y147BKBX1A#A
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 22.0 (650)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 27-13/32 x 36-5/8 x 13-13/16 (696 x 930 x 351)
Packaged Dimensions (H x W x D) inch (mm) 29-7/8 x 42-3/8 x 18-7/8 (760 x 1075 x 480)
Weight lbs (kg) 101 (46)
Gross Weight lbs (kg) 110 (50)
Document No. 3D148691
COOLING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
OUTDOOR: 95°FDB (35°CDB)
background
Specification Data DAMA-SM-23-021
18 Specifications
Heatpump
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTXF09A
OUTDOOR UNIT
RXF09A
Cooling Heating
Rated Capacity (Min. ~ Max.)
kW 2.64 (1.30 - 3.28) 2.93 (1.30 - 4.19)
Btu/h 9000 (4400 - 11200) 10000 (4400 - 14300)
Moisture Removal gal/h 0.05
Rated Running Current A 3.13 3.13
Rated Power Consumption W 720 719
EER2 Btu/h/W 12.5 N/A
SEER2 21.0 N/A
COP
W/W
N/A 4.06
HSPF2 N/A 10.2
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 3/8” (9.52)
Refrigerant
Type R32
Charge lbs (kg) 1.65 (0.75)
Max. Interunit Piping Length ft (m) 65-5/8 (20)
Max. Interunit Height Difference ft (m) 49-1/4 (15)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTXF09A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 466
High CFM 431 402
Medium CFM 322
Low CFM 249
Quiet CFM 142
219
Sound Pressure Level (H/M/L/Q) dBA 44/37/30/19 43/36/30/25
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 22
Running Current (Rated) A 0.10
Power Consumption (Rated) W 29
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D) inch (mm) 12-3/8 x 32-11/16 x 14-1/16 (314 x 830 x 357)
Weight lbs (kg) 19.8 (9.0)
Gross Weight lbs (kg) 24.0 (10.9)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RXF09A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1051 966
Sound Pressure Level dBA 46 48
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 24
Insulation Grade E
Running Current (Rated) A 0.61
Power Consumption (Rated) W 46
Motor Output W 26
Poles 8
Compressor
Type HERMETIC SWING
Model 1Y091BKCX1A#G
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 12.7 (375)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D) inch (mm) 24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weight lbs (kg) 60 (27)
Gross Weight lbs (kg) 66 (30)
Document No. 3D148691
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)
background
DAMA-SM-23-021 Specification Data
Specifications 19
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTXF12A
OUTDOOR UNIT
RXF12A
Cooling Heating
Rated Capacity (Min. ~ Max.)
kW 3.52 (1.30 - 4.28) 3.96 (1.30 - 5.28)
Btu/h 12000 (4400 - 14600) 13500 (4400 - 18000)
Moisture Removal gal/h 0.16
Rated Running Current A 4.17 4.52
Rated Power Consumption W 960 1038
EER2 Btu/h/W 12.5 N/A
SEER2 21.0 N/A
COP
W/W
N/A 3.8
HSPF2 N/A 10.2
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 3/8” (9.52)
Refrigerant
Type R32
Charge lbs (kg) 1.65 (0.75)
Max. Interunit Piping Length ft (m) 65-5/8 (20)
Max. Interunit Height Difference ft (m) 49-1/4 (15)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTXF12A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 473
High CFM 436 412
Medium CFM 316
Low CFM 247
Quiet CFM 132 210
Sound Pressure Level (H/M/L/Q) dBA 46/38/32/19 45/37/31/26
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 22
Running Current (Rated) A 0.10
Power Consumption (Rated) W 29
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-1/3 x 30-5/16 x 9-3/16 (288 x 770 x 234)
Packaged Dimensions (H x W x D) inch (mm) 12-3/8 x 32-11/16 x 14-1/16 (314 x 830 x 357)
Weight lbs (kg) 20.9 (9.5)
Gross Weight lbs (kg) 25.8 (11.7)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RXF12A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1051 966
Sound Pressure Level dBA 48
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 24
Insulation Grade E
Running Current (Rated) A 0.61
Power Consumption (Rated) W 46
Motor Output W 26
Poles 8
Compressor
Type HERMETIC SWING
Model 1Y091BKCX1A#G
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 12.7 (375)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 21-11/16 x 26-1/2 x 11-3/16 (550 x 675 x 284)
Packaged Dimensions (H x W x D) inch (mm) 24-1/64 x 31-3/8 x 15-1/8 (610 x 801 x 384)
Weight lbs (kg) 60 (27)
Gross Weight lbs (kg) 66 (30)
Document No. 3D148691
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)
background
Specification Data DAMA-SM-23-021
20 Specifications
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTXF18A
OUTDOOR UNIT
RXF18A
Cooling Heating
Rated Capacity (Min. ~ Max.)
kW 5.30 (2.02 - 6.45) 6.33 (1.70 - 7.74)
Btu/h 18100 (6900 - 22000) 21600 (5800 - 26400)
Moisture Removal gal/h 0.61
Rated Running Current A 6.56 7.64
Rated Power Consumption W 1508 1756
EER2 Btu/h/W 12.0 N/A
SEER2 21.0 N/A
COP
W/W
N/A 3.60
HSPF2 N/A 9.60
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 1/2” (12.70)
Refrigerant
Type R32
Charge lbs (kg) 3.31 (1.50)
Max. Interunit Piping Length ft (m) 98-1/2 (30)
Max. Interunit Height Difference ft (m) 65-5/8 (20)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTXF18A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 754
High CFM 716
Medium CFM 605
Low CFM 467
Quiet CFM 395
Sound Pressure Level (H/M/L/Q) dBA 49/44/38/33 49/42/37/33
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 39
Running Current (Rated) A 0.17
Power Consumption (Rated) W 54
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-11/16 x 39-9/16 x 10-3/4 (297 x 990 x 273)
Packaged Dimensions (H x W x D) inch (mm) 14-3/4 x 14-5/8 x 42-1/4 (375 x 371 x 1073)
Weight lbs (kg) 30.5 (13.8)
Gross Weight lbs (kg) 36 (16.5)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RXF18A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1879 1833
Sound Pressure Level dBA 54
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 23
Insulation Grade E
Running Current (Rated) A 1.30
Power Consumption (Rated) W 85
Motor Output W 55
Poles 8
Compressor
Type HERMETIC SWING
Model 2Y147BKBX1A#A
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 22.0 (650)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 27-13/32 x 36-5/8 x 13-13/16 (696 x 930 x 351)
Packaged Dimensions (H x W x D) inch (mm) 29-7/8 x 42-3/8 x 18-7/8 (760 x 1075 x 480)
Weight lbs (kg) 101 (46)
Gross Weight lbs (kg) 110 (50)
Document No. 3D148691
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)
background
DAMA-SM-23-021 Specification Data
Specifications 21
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT FTXF24A
OUTDOOR UNIT
RXF24A
Cooling Heating
Rated Capacity (Min. ~ Max.)
kW 6.57 (2.05 - 7.74) 6.92 (1.82 - 8.38)
Btu/h 22400 (7000 - 26400) 23600 (6200 - 28600)
Moisture Removal gal/h 0.88
Rated Running Current A 8.12 9.0
Rated Power Consumption W 1867 2070
EER2 Btu/h/W 12.0 N/A
SEER2 21.0 N/A
COP
W/W
N/A 3.34
HSPF2 N/A 9.10
Power Factor (Rated) N/A
Piping
Connections
Liquid inch (mm) 1/4” (6.35)
Gas inch (mm) 5/8” (15.88)
Refrigerant
Type R32
Charge lbs (kg) 3.31 (1.50)
Max. Interunit Piping Length ft (m) 98-1/2 (30)
Max. Interunit Height Difference ft (m) 65-5/8 (20)
Chargeless ft (m) 32-13/16 (10)
Amount of Additional Charge of Refrigerant oz/ft (g/m) 0.18 (17)
Drawing No. 3D148846
INDOOR UNIT FTXF24A
Front Panel Colour WHITE
Airflow Rate
Turbo CFM 754
High CFM 716
Medium CFM 605
Low CFM 467
Quiet CFM 395
Sound Pressure Level (H/M/L/Q) dBA 53/45/39/34 53/43/38/34
Fan
Type CROSS FLOW
Drive DIRECT
Speed 3 STEPS, AUTO, QUIET, TURBO
Fan Motor
Type DIRECT CURRENT
Motor Output W 39
Running Current (Rated) A 0.17
Power Consumption (Rated) W 54
Air Direction Control UP, DOWN, LEFT, RIGHT
Air Filter CATECHIN
Dimensions (H x W x D) inch (mm) 11-11/16 x 39-9/16 x 10-3/4 (297 x 990 x 273)
Packaged Dimensions (H x W x D) inch (mm) 14-3/4 x 14-5/8 x 42-1/4 (375 x 371 x 1073)
Weight lbs (kg) 30.5 (13.8)
Gross Weight lbs (kg) 36 (16.5)
Condensate Drain Size inch (mm) 5/8 (16)
Document No. 3D148845
OUTDOOR UNIT RXF24A
Casing Colour IVORY WHITE
Airflow Rate High CFM 1879 1833
Sound Pressure Level dBA 55
Fan
Type PROPELLER
Drive DIRECT
Fan Motor
Type DIRECT CURRENT
Index of protection (IP) 23
Insulation Grade E
Running Current (Rated) A 1.30
Power Consumption (Rated) W 88
Motor Output W 55
Poles 8
Compressor
Type HERMETIC SWING
Model 2Y147BKBX1A#A
Oil type DAPHNE FW68DA
Oil amount oz (cm
3
) 22.0 (650)
Heat Exchanger Type FIN TUBE
Dimensions (H x W x D) inch (mm) 27-13/32 x 36-5/8 x 13-13/16 (696 x 930 x 351)
Packaged Dimensions (H x W x D) inch (mm) 29-7/8 x 42-3/8 x 18-7/8 (760 x 1075 x 480)
Weight lbs (kg) 101 (46)
Gross Weight lbs (kg) 110 (50)
Document No. 3D148691
COOLING HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB) INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB) OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)
background
Functions DAMA-SM-23-021
22 Specifications
2. Functions
Category Functions
FTKF09/12A
RKF09/12A
FTKF18/24A
RKF18/24A
FTXF09/12A
RXF09/12A
FTXF18/24A
RXF18/24A
Basic Function
Inverter
Operation Limit for Cooling (°CDB)(O/D) 10 ~ 48 10 ~ 50 10 ~ 48 10 ~ 50
Operation Limit for Cooling (°FDB)(O/D) 50 ~ 118.4 50 ~ 122.0 50 ~ 118.4 50 ~ 122.0
Operation Limit for Heating (°CWB)(O/D) — — -15 ~ 18 -15 ~ 18
Operation Limit for Heating (°FWB)(O/D) — — 5 ~ 64.4 5 ~ 64.4
Compressor
Scroll Compressor — — — —
Rotary Compressor — — — —
Swing Compressor
Comfortable
Airflow
Power-airflow Flap
—
—
Power-airflow Dual Flaps —
—
Power-airflow Diffuser — — — —
Wide Angle Louvers
Vertical Auto-Swing (Up and Down)
Horizontal Auto-Swing (Right and Left) — — — —
3D Airflow — — — —
Breeze Airflow — — — —
Comfort Control
Auto Fan Speed
Indoor Unit Quiet Operation
Intelligent Eye Operation — — — —
Automatic Defrosting — —
Operation
Automatic Operation — —
Programme Dry Function
Fan Only
Lifestyle
Convenience
Powerful Operation (Non Inverter) — — — —
Inverter Powerful Operation
Energy Saving Function
Sleep Mode
Indoor Unit ON/OFF Button
R/C with Backlight
Signal Receiving Sign (R/C)
Set Temperature Display (R/C)
Health & Clean
Saranet Filter — — — —
GIN-ION Filter — — — —
Catechin Filter / Green Tea Filter
Titanium Apatite Air-Purifying Filter
Enzyme Blue Deodorizing Filter — — — —
PM 2.5 Filter — — — —
Streamer — — — —
Plasma — — — —
Wipe Clean Flat Panel
Coil Clean (by APP control) — — — —
Timer
Weekly Timer Operation (Wired R/C) — — — —
24-hour ON/OFF Timer (R/C)
Countdown ON/OFF Timer (R/C) — — — —
Worry Free
(Reliability &
Durability)
Auto Restart (after Power Failure)
Self-diagnosis
Anti-corrosion Treatment of Outdoor Heat Exchanger Blue Fin Blue Fin Blue Fin Blue Fin
Low/High Voltage Shield (PCB Level / Unit Level) — — — —
Flexibility
Pre-charged Piping Length 32-13/16 ft 32-13/16 ft 32-13/16 ft 32-13/16 ft
Either Side Drain (Right or Left)
Detachable Drain Pan
Low ambient cooling operation (-15˚C) (5˚F)
Remote Control
Wireless LAN Connectivity
*
*
*
*
BAG Connectivity
*
*
*
*
iTM Connectivity — — — —
DIII-NET Connectivity — — — —
Remote
Controller
Wireless BRC52B64 BRC52B64 BRC52B63 BRC52B63
Wired (Optional) BRC51D61 BRC51D61
BRC51D61 BRC51D61
Note:
—
*
: Available
: Not available
: Optional (Refer to DAMA Spare Part Team for more details on optional items.)
background
DAMA-SM-23-021
Part 3 Functions and Control 23
Part 3
Functions and Control
1. Main Functions......................................................................................24
1.1 Temperature Control ..............................................................................24
1.2 Frequency Control..................................................................................24
1.3 Airflow Direction Control.........................................................................26
1.4 Fan Speed Control for Indoor Unit .........................................................26
1.5 Dry Mode................................................................................................27
1.6 Automatic Operation...............................................................................28
1.7 Thermostat Control.................................................................................29
1.8 ECO+ Operation.....................................................................................30
1.9 Sleep Mode ............................................................................................31
1.10 POWERFUL Operation ..........................................................................31
1.11 Other Functions......................................................................................32
2. Thermistor Functions ............................................................................33
3. Control Specification .............................................................................34
3.1 Mode Hierarchy ......................................................................................34
3.2 Frequency Control..................................................................................35
3.3 Standby Electricity Saving (Suspend Function) .....................................37
3.4 Controls at Mode Changing/Start-up......................................................37
3.5 Discharge Pipe Temperature Control.....................................................39
3.6 Input Current Control..............................................................................40
3.7 Freeze-up Protection Control .................................................................41
3.8 Heating Peak-cut Control .......................................................................42
3.9 Outdoor Fan Control...............................................................................43
3.10 Liquid Compression Protection Function................................................44
3.11 Defrost Control .......................................................................................44
3.12 Electronic Expansion Valve Control .......................................................45
3.13 Malfunctions ...........................................................................................49
background
Main Functions DAMA-SM-23-021
24 Functions and Control
1. Main Functions
1.1 Temperature Control
Definitions of
Temperatures
The definitions of temperatures are classified as following.
Room temperature: temperature of lower part of the room
Set temperature: temperature set by remote controller
Room thermistor temperature: temperature detected by room temperature thermistor
Target temperature: temperature determined by microcomputer
Temperature
Control
The temperature of the room is detected by the room temperature thermistor. However, there is
a difference between the temperature detected by room temperature thermistor and the
temperature of lower part of the room, depending on the type of the indoor unit or installation
condition. In practice, the temperature control is done by the target temperature appropriately
adjusted for the indoor unit and the temperature detected by room temperature thermistor.
1.2 Frequency Control
Control
Parameters
The frequency of the compressor is controlled by the following 2 parameters:
The load condition of the operating indoor unit
The difference between the room thermistor temperature and the target temperature
The target frequency is adapted by additional parameters in the following cases:
Frequency restrictions
Initial settings
Forced cooling operation
Inverter Principle To regulate the capacity, a frequency control is needed. The inverter makes it possible to
control the rotation speed of the compressor. The following explain the inverter principle:
Phase 1
The supplied AC power source is converted into the DC power source for the present.
Phase 2
The DC power source is reconverted into the three phase AC power source with variable
frequency.
When the frequency increases, the rotation speed of the compressor increases resulting in
an increase of refrigerant circulation. This leads to a larger amount of heat exchange per
unit.
When the frequency decreases, the rotation speed of the compressor decreases resulting in
a decrease of refrigerant circulation. This leads to a smaller amount of heat exchange per
unit.
Target temperature
Set temperature
Room temperature
Room thermistor temperature
background
DAMA-SM-23-021 Main Functions
Functions and Control 25
The following drawing shows a schematic view of the inverter principle:
Inverter Features The inverter provides the following features:
The regulating capacity can be changed according to the changes in the outdoor
temperature and cooling load.
Quick cooling
The rotation speed of the compressor is increased when starting the cooling.
This enables to reach the set temperature quickly.
Comfortable air conditioning
A fine adjustment is integrated to keep the room temperature constant.
Energy saving cooling
Once the set temperature is reached, the energy saving operation enables to maintain the
room temperature at low power.
Frequency Limits The following functions regulate the minimum and maximum frequency:
Compressor protection function. Refer to page 37.
Discharge pipe temperature control. Refer to page 39.
Input current control. Refer to page 40.
Freeze-up protection control. Refer to page 41.
Forced Cooling
Operation
Refer to page 107 for details.
Refrigerant circulation rate (high)
high f
low f
freq=variable
Refrigerant circulation rate (low)
high speed
low speed
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
freq=
constant
capacity=
variable
AC
power
DC
power
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
50 Hz
50 Hz
60 Hz60 Hz
background
Main Functions DAMA-SM-23-021
26 Functions and Control
1.3 Airflow Direction Control
Power-Airflow
Flap
The large flap sends a large volume of air downward to the floor and provides an optimum
control in cooling and dry operation.
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing The followings explain the auto-swing process for cooling, dry and fan:
1.4 Fan Speed Control for Indoor Unit
FTK/FTX Outline Phase control and fan speed control contains 5 steps: SL, L, M, H, SH.
The airflow rate can be automatically controlled depending on the difference between the room
thermistor temperature and the set temperature.
In heating mode, the indoor fan speed will be regulated according to the indoor heat exchanger
temperature and the difference between the room temperature and the required set
temperature.
Automatic Fan
Speed Control
In automatic fan speed operation, the step SL, & SH is not available.
= The airflow rate is automatically controlled within this range when FAN setting button is
set to automatic.
Class Cooling / Dry / Fan (A-B) Heating (A - B)
09/12 40 - 65
45 - 90
18/24 45 - 70
B°
A°
0°
Series Class SL L M H SH
FTK Series
09 142 249 322 431 466
12 132 247 316 436 473
18 395 467 605 716 754
24 395 467 605 716 754
Step
L
M
H
Cooling Heating
background
DAMA-SM-23-021 Main Functions
Functions and Control 27
Cooling
The following drawings explain the principle of fan speed control for cooling.
Heating
The following drawings explain the principle of fan speed control for heating.
On heating mode, the indoor fan speed will be regulated according to the heat exchanger
temperature and the difference between the room temperature and the required target
temperature.
1.5 Dry Mode
Outline Program dry operation removes humidity. Since the microcomputer controls the airflow rate, the
FAN setting buttons are inoperable.
Details The microcomputer automatically sets the airflow rate. The difference between the room
thermister temperature and the set temperature is divided into zones. Then, the unit operates in
an appropriate capacity for each zone to maintain the temperature and humidity at a
comfortable level.Zone B continues to stay for 120 seconds before the unit will turn to
thermostat ON.
Series Class SL L M H SH
FTX Series
09 142(C); 219(H) 249 322 431(C); 402(H) 466
12 132(C); 210(H) 247 316 436(C); 412 (H) 473
18 395 467 605 716 754
24 395 467 605 716 754
Room thermistor temperature – set temperature
Fan speed
+1.5°C
(+2.7°F)
+0.5°C
(+0.9°F)
+2°C
(+3.6°F)
+1.0°C
(+1.8°F)
H
L
Room thermistor temperature – set temperature
Fan speed
+2.5°C
(+4.5°F)
0°C
(0°F)
+2°C
(+3.6°F)
H
+0.5°C
(+0.9°F)
L
background
Main Functions DAMA-SM-23-021
28 Functions and Control
1.6 Automatic Operation
Automatic Cooling / Heating Function (Heat Pump Only)
When the AUTO mode is selected with the remote controller, the microcomputer automatically
determines the operation mode from cooling and heating according to the room temperature
and setting temperature at the time of the operation startup, and automatically operates in that
mode.
The unit automatically switches the operation mode to cooling or heating to maintain the room
temperature at the main unit setting temperature.
Details
Explanation of
the Function
1. Remote controller setting temperature is set as automatic cooling / heating setting
temperature 16°C (60°F) to 30°C (86°F).
2. Main unit setting temperature equals remote controller setting temperature.
3. Operation ON / OFF point and mode switching point are as follows.
a Heating Cooling switching point:
Room temperature ≥ Main unit setting temperature +2.5 deg (+4.5°F).
b Cooling Heating switching point:
Room temperature < Main unit setting temperature -2.5 deg (-4.5°F)
c Thermostat ON / OFF point is the same as the ON / OFF point of cooling or heating
operation.
4. During initial operation
Room temperature ≥ Remote controller setting temperature: Cooling operation
Room temperature < Remote controller setting temperature: Heating operation
Ex : When the set temperature is 25°C (77°F),
Scenario 1 Thermostat OFF 23.5°C (74.3°F). If room temperature continues to drop to
22.5°C (72.5°F) :
Switch from Cooling Operation to Heating Operation
Scenario 2 Room temperature maintains at 25°C (77°F) :
No Switch in Operation mode
Scenario 3 Thermostat OFF -> 26.5°C (79.7°F). If room temperature continues to increase to
27.5°C (81.5°F) :
Switch from Heating Operation to Cooling Operation
Target temperature X Thermostat OFF point Y Thermostat ON point Y
Setting temperature
Room thermistor temperature
- X = (< -1.5° C) or (< -2.7° F)
Room thermistor temperature
- X = (≥ -1.5° C) or (≥ - 2.7° F)
Zone C - Thermostat ON
Zone B
Y
X
+0.5
°C (0.9°F)
Zone A - Thermostat OFF
Zone B
Cooling Operation
Set point +2.5°C (+4.5°F)
Set point +1.5°C (+2.7°F)
=Thermostat OFF
Heating Operation
Set point -1.5°C (-2.7°F)
=Thermostat OFF
Set point -2.5°C (-4.5°F)
background
DAMA-SM-23-021 Main Functions
Functions and Control 29
1.7 Thermostat Control
Outline Thermostat control is based on the difference between the room thermistor temperature and the
set temperature.
Details Thermostat OFF Conditions
The temperature difference is in the zone A.
Thermostat ON Conditions
The temperature difference returns to the zone C after being in the zone A.
The operation turns on in any zones except A.
The monitoring time has passed while the temperature difference is in the zone B.
(Cooling/Dry/Heating: 2 minutes)
Cooling/Dry
Heating
Zone B
Zone A
OFF
ON
Zone C
Zone C
–1.0°C
(–1.8°F)
Cooling : –0.5°C (–0.9°F)
Dry : –0.5°C (–0.9°F)
Cooling/Dry : –1.5°C (–2.7°F)
Room thermistor temperature – set temperature
OFF
OFF
ON
ON
0.5°C
(0.9°F)
1.5°C
(2.7°F)
A
B
C
Room temperature – set temperature
background
Main Functions DAMA-SM-23-021
30 Functions and Control
1.8 ECO+ Operation
Outline ECO+ operation reduces the maximum operating power input and adjust the target temperature
setting. This operation is particularly convenient for energy-saving. It is also a major bonus
when breaker capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pressing ECO+ button on the wireless remote controller.
Details
Cool mode
User set temperature <
24°C (75°F)
User set temperature ≥
24°C (75°F)
Heat mode
User set temperature >
20°C (68°F)
User set temperature ≤
20°C (68°F)
24 (75)
Unit runs at 24˚C (75˚F)
ECO
+
activated
User set
temp
Unit runs at (user set temperature + 1°C (1.8°F)
(User set temp + 1°C (1.8°F)
ECO
+
activated
24 (75)
User
set temp
Unit runs at 20°C (68°F)
ECO
+
activated
User set
temp
20 (68)
Unit runs at (user set temperature - 1°C (1.8°F)
ECO
+
activated
(User set temp - 1°C (1.8°F)
20 (68)
User set
temp
background
DAMA-SM-23-021 Main Functions
Functions and Control 31
Note
1.9 Sleep Mode
Outline SLEEP Mode can be activated through the remote controller to keep the thermal comfort while
sleeping.
Details SLEEP Mode continues operation at the target temperature for the first hour, then automatically
raises the target temperature slightly in case of cooling, or lowers it slightly in case of heating.
This prevents excessive cooling in summer and excessive heating in winter to ensure
comfortable sleeping conditions and also saves electricity.
1.10 POWERFUL Operation
Outline In order to exploit the cooling capacity to full extent, the air conditioner can be operated by
increasing the indoor fan rotating speed and the compressor frequency.
Details When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
H = high fan
A = refer table below
POWERFUL operation cannot be used together with ECO+ operation.
target temperature
<COOL or DRY>
run
sleep operation
target temperature
<HEAT>
1hr 1hr
(shift 0.5°C/0.9°F)
(no offset on target
temperature)
(shift 1.0°C/1.8°F)
(shift 1.0°C/1.8°F)
(shift 2.0°C/3.6°F)
ON signal of sleep operation
ON signal of sleep operation+operation ON signal
OFF signal of sleep operation
operation OFF signal
Operation mode Fan speed Target temperature
COOL H tap + A rpm Setting temperature -4°C (-7.2°F)
HEAT H tap + A rpm Setting temperature +6°C (+10.8°F)
Class
09 12 18 24
Model Mode A
FTX
Cool 80 90 80 80
Heat 150 150 80 80
FTK Cool 80 90 80 80
background
Main Functions DAMA-SM-23-021
32 Functions and Control
Note
Note
Note
1.11 Other Functions
1.11.1 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.11.2 Indoor Unit ON/OFF Switch
Indoor unit ON/OFF switch is provided on the display of the unit.
Press ON/OFF switch once to start operation. Press once again to stop it.
ON/OFF switch is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
Forced Cooling Operation
Forced cooling operation can be started by pressing ON/OFF switch for 5 ~ 9 seconds while the
unit is not operating.
Refer to page 107 for details.
Forced cooling operation will not be started if the ON/OFF switch is pressed for 10 seconds or
more.
1.11.3 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the operation restarts
automatically in the same conditions as before when the power supply is restored to the
conditions prior to the power failure.
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
1.11.4 Hot-start function
In order to prevent the cold air blast that normally comes when heating is started, the
temperature of the heat exchanger of the indoor is detected, and either the airflow is stopped or
is made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat gets turned ON.
Operation mode Temperature setting Airflow rate
FTK/FTX series AUTO 25°C (77°F) Automatic
ON/OFF
switch
background
DAMA-SM-23-021 Thermistor Functions
Functions and Control 33
2. Thermistor Functions
(1) Discharge
Pipe Thermistor
The discharge pipe thermistor is used for controlling discharge pipe temperature. If the
discharge pipe temperature (used in place of the inner temperature of the compressor) rises
abnormally, the operating frequency becomes lower or the operation halts.
The discharge pipe thermistor is used for detecting disconnection of the discharge pipe
thermistor.
(2) Outdoor Heat
Exchanger
Thermistor
The outdoor heat exchanger thermistor is used for controlling the target discharge pipe
temperature. The system sets the target discharge pipe temperature according to the
outdoor and indoor heat exchanger temperature, and controls the electronic expansion valve
opening so that the target discharge pipe temperature can be obtained.
In cooling operation, the outdoor heat exchanger thermistor is used for detecting the
disconnection of the discharge pipe thermistor. When the discharge pipe temperature drops
below the outdoor heat exchanger temperature by more than a certain value, the discharge
pipe thermistor is judged as disconnected.
In cooling operation, the outdoor heat exchanger thermistor is used for high pressure
protection.
(3) Outdoor
Temperature
Thermistor
The outdoor temperature thermistor detects the outdoor air temperature and is used for
refrigerant shortage detection, input current control, outdoor fan control, liquid compression
protection function, and so on.
(4) Indoor Heat
Exchanger
Thermistor
The indoor heat exchanger thermistor is used for controlling the target discharge pipe
temperature. The system sets the target discharge pipe temperature according to the
outdoor and indoor heat exchanger temperature, and controls the electronic expansion valve
opening so that the target discharge pipe temperature can be obtained.
In cooling operation, the indoor heat exchanger thermistor is used for freeze-up protection
control. If the indoor heat exchanger temperature drops abnormally, the operating frequency
becomes lower or the operation halts.
During heating, the indoor heat exchanger thermistor is used for detecting disconnection of
the discharge pipe thermistor.
When the discharge pipe temperature becomes lower than the indoor heat exchanger
temperature, the discharge pipe thermistor is judged as disconnected.
The indoor heat exchanger thermistor is also used for preventing abnormal high pressure.
(5) Room
Temperature
Thermistor
The room temperature thermistor detects the room air temperature and is used for
controlling the room air temperature.
(A)FTK/FTX series only
Compressor
Four way valve
Expansion valve
(3) Outdoor
Temperature
Thermistor
(1) Discharge Pipe
Temperature
(4) Indoor Heat
Exchanger
Thermistor
(5) Room
Temperature
Thermistor
(2) Outdoor Heat
Exchanger
Thermistor
background
Control Specification DAMA-SM-23-021
34 Functions and Control
Note
3. Control Specification
3.1 Mode Hierarchy
Outline The air conditioner control has normal operation mode, forced operation mode, and power
transistor test mode for installation and servicing.
Details Applicable for FTK series.
There are following modes; Fan, Cooling (includes drying), Stop.
Applicable for FTX series.
There are following modes; Cooling (includes drying), Heating (includes defrosting), Stop.
Unless specified otherwise, dry operation command is regarded as cooling operation.
Air conditioner control mode
Forced operation mode
Forced cooling operation (for pump down operation)
Power transistor test mode
Normal operation mode
Fan
Cooling (includes drying)
Stop (indoor unit: OFF)
Discharging from capacitor
Stop
Heating
Defrosting
Stop mode (except for cooling/heating modes by indoor command)
Air conditioner control mode
Forced operating mode
Forced cooling (for Pump Down Operation)
Normal operating mode
Cooling
Discharging from capacitor
Stop
background
DAMA-SM-23-021 Control Specification
Functions and Control 35
3.2 Frequency Control
Outline The compressor frequency is determined according to the difference between the room
thermistor temperature and the target temperature.
*Only applicable for heat-pump model
Details For Cooling Only model:
1. Determine command frequency
Command frequency is determined in the following order of priority.
(1) Forced cooling
(2) Indoor frequency command
2. Determine upper limit frequency
The minimum value is set as the upper limit frequency among the frequency upper limits of
the following functions:
Compressor protection, input current, discharge pipe temperature, freeze-up protection.
3. Determine lower limit frequency
The maximum value is set as the lower limit frequency among the frequency lower limits of
the following function:
Pressure difference upkeep.
4. Determine prohibited frequency
There is a certain prohibited frequency such as a power supply frequency.
For Heat-pump model:
1. Determine command frequency
Command frequency will be determined in the following order of priority.
1.1 Limiting frequency by drooping function
Input current, discharge pipes, peak cutting, freeze-up protection, dew prevention, fin
thermistor temperature.
1.2 Limiting defrost control time
1.3 Forced cooling
1.4 Indoor frequency command
2. Determine upper limit frequency
Set a minimum value as an upper limit frequency among the frequency upper limits of the
following functions:
Compressor protection, input current, discharge pipes, peak cutting, freeze-up protection,
defrost.
3. Determine lower limit frequency
Set a maximum value as an lower limit frequency among the frequency lower limits of the
following functions:
Four way valve operating compensation, draft prevention, pressure difference upkeep.
4. Determine prohibited frequency
There is a certain prohibited frequency such as a power supply frequency.
Initial frequency
PI control
Defrost control*
Lower limit function
Four way valve operating compensation, etc*
Command frequency
Lower limit frequency
FMIN
Upper limit frequency
FMAX
Limit frequency
Skip control
Target frequency
Upper limit function
Compressor protection function
Dropping function
Input current control, etc.
When the shift of the frequency is less than zero (∆F<0) by PI control,
the target frequency is used as the command frequency.
background
Control Specification DAMA-SM-23-021
36 Functions and Control
Initial Frequency When starting the compressor, the frequency is initialized according to the D value of the
indoor unit.
D signal: Indoor frequency command
The difference between the room thermistor temperature and the target temperature is taken as
the D value and is used for D signal of frequency command.
In Cooling Mode In Heating Mode In Dry Mode
PI Control 1. P control
D value is calculated in each sampling time (20 seconds), and the frequency is adjusted
according to its difference from the frequency previously calculated.
2. I control
If the operating frequency does not change for more than a certain fixed time, the frequency
is adjusted according to D value.
When D is low, the frequency is lowered.
When D is high, the frequency is increased.
3. Frequency control when other controls are functioning
When frequency is dropping:
Frequency control is carried out only when the frequency drops.
For controlling lower limit:
Frequency control is carried out only when the frequency rises.
4. Upper and lower limit of frequency by PI control
The frequency upper and lower limits are set according to the command of the indoor unit.
When the indoor unit quiet operation command comes from the indoor unit, the upper limit
frequency is lower than the usual setting.
Temperature
difference (°C)
D signal
Temperature
difference (°C)
D signal
Temperature
difference (°C)
D signal
-1.5 0 -1.5 0 -1.5 0
-1.0 1 -1.0 1 -1.0 1
-0.5 2 -0.5 2 -0.5 2
0.0 3 0.0 3 0.0 3
0.5 4 0.5 4 0.5 4
1.0 5 1.0 5 1.0 5
1.5 6 1.5 6 1.5 6
2.0 7 2.0 7 2.0 7
2.5
8
2.5 8 2.5 8
3.0 3.0
9
3.5
4.0
Temperature
difference (°F)
D signal
Temperature
difference (°F)
D signal
Temperature
difference (°F)
D signal
-2.7 0 -2.7 0 -2.7 0
-1.8 1 -1.8 1 -1.8 1
-0.9 2 -0.9 2 -0.9 2
0.0 3 0.0 3 0.0 3
0.9 4 0.9 4 0.9 4
1.8 5 1.8 5 1.8 5
2.7 6 2.7 6 2.7 6
3.6 7 3.6 7 3.6 7
4.5
8
4.5 8 4.5 8
5.4 5.4
9
6.3
7.2
background
DAMA-SM-23-021 Control Specification
Functions and Control 37
3.3 Standby Electricity Saving (Suspend Function)
Outline
This function is to save standby electricity consumption while the air conditioner is not in operation
by partially separating the electrical circuit of indoor and outdoor units from the power source.
Details When standby electricity saving is ON, the system enters suspend state if both indoor and
outdoor units are not in operation.
The system will not go into suspend state when some voltage is applied to the outdoor unit
for protection purpose even if the indoor unit is not in operation.
In suspend state, power supply to the outdoor unit is halted and there is no communication
between the indoor unit and the outdoor unit.
Also the service monitor LED (LED A) lights off.
To return from the suspend state, start fan or other operation to turn on the indoor unit.
3.4 Controls at Mode Changing/Start-up
3.4.1 3-Minute Standby
Turning on the compressor is prohibited for 3 minutes after turning off.
3.4.2 Compressor Protection Function
When turning the compressor from OFF to ON, the upper limit of frequency is set as follows.
(sec.)
Time
(Hz)
Frequency
72Hz
90Hz
112Hz
Class 09
54Hz
30 60 210 60 1
40Hz
(sec.)
Time
(Hz)
Frequency
72Hz
90Hz
112Hz
Class 12
54Hz
30 60 210 60 1
38Hz
(sec.)
Time
(Hz)
Frequency
Class 18
300 420 60 0
82Hz
80Hz
48Hz
(sec.)
Time
(Hz)
Frequency
Class 24
300 420 60 0
94Hz
80Hz
48Hz
background
Control Specification DAMA-SM-23-021
38 Functions and Control
3.4.3 Four Way Valve Switching
Outline Heat Pump Only
During the heating operation current must be conducted and during cooling and defrosting
current must not be conducted. In order to eliminate the switching sound (as the four way valve
coil switches from ON to OFF) when the heating is stopped, the delay switch of the four way
valve must be carried out after the operation stopped.
Details The OFF delay of four way valve
Energize the coil for X sec after unit operation is stopped.
3.4.4 Four Way Valve Operation Compensation
Outline Heat Pump Only
At the beginning of the operation as the four way valve is switched, acquire the differential
pressure required for activating the four way valve by having output the operating frequency,
which is more than a certain fixed frequency, for a certain fixed time.
Details Starting Conditions
1. When starting compressor for heating.
2. When the operating mode changes to cooling from heating.
3. When starting compressor for rushing defrosting or resetting.
4. When starting compressor for the first time after the reset with the power is ON.
5. When starting compressor for heating next to the suspension of defrosting.
6. When starting compressor next to the fault of switching over cooling/heating.
Class X
09/12/18/24 160 seconds
background
DAMA-SM-23-021 Control Specification
Functions and Control 39
3.5 Discharge Pipe Temperature Control
Outline The discharge pipe temperature is used as the internal temperature of the compressor. If the
discharge pipe temperature rises above a certain level, the upper limit of frequency is set to
keep the discharge pipe temperature from rising further.
Details
Zone Control
Stop zone When the temperature reaches the stop zone, the compressor stops.
Dropping zone The upper limit of frequency decreases.
Keep zone The upper limit of frequency is kept.
Up zone The upper limit of frequency increases.
Reset zone The upper limit of frequency is cancelled
Class
09/12 18/24
A (°C) 110 118
B (°C) 105 104
C (°C) 98 99
D (°C) 93 93
E (°C) 88 81
Class
09/12 18/24
A (°F) 230 244.4
B (°F) 221 219.2
C (°F) 208.4 210.2
D (°F) 199.4 199.4
E (°F) 190.4 177.8
Discharge pipe
temperature
Stop zone
Dropping zone
Keep zone
Up zone
Reset zone
E°C (°F)
A°C (°F)
B°C (°F)
C°C (°F)
D°C (°F)
background
Control Specification DAMA-SM-23-021
40 Functions and Control
3.6 Input Current Control
Outline The microcomputer calculates the input current while the compressor is running, and sets the
frequency upper limit based on the input current.
Details
Frequency control in each zone
Limitation of current dropping and stop value according to the outdoor temperature
The current drops when outdoor temperature becomes higher than a certain level
(depending on the model).
Zone Control
Stop zone After the input current remains in the stop zone for 2.5 seconds, the compressor is stopped.
Dropping The upper limit of the compressor frequency is defined as operation frequency – 2 Hz.
After this, the output frequency is lowered by 2 Hz every second until it reaches the keep zone.
Keep zone The present maximum frequency goes on.
Reset zone Limit of the frequency is cancelled.
Class
Mode Current (A) 09 12 18 24
Cooling
A 14 14 13 13
B 7 7 11 11
C 6.25 6.25 10 10
Class
Mode Current (A) 09 12 18 24
Heating
A 14 14 16 16
B 7.75 7.75 13 13
C 7 7 12 12
Compressor Stop
Input current
Dropping zone
Stop zone
Keep zone
Reset zone
A
(A)
B
C
background
DAMA-SM-23-021 Control Specification
Functions and Control 41
3.7 Freeze-up Protection Control
Outline During cooling operation, the signals sent from the indoor unit control the operating frequency
limitation and prevent freezing of the indoor heat exchanger. The signal from the indoor unit is
divided into zones.
Details The operating frequency limitation is judged with the indoor heat exchanger temperature.
Frequency control in each zone
All classes
All classes
Zone Control
Reset zone The upper limit of frequency is cancelled
Up zone The upper limit of frequency increases
Keep zone The upper limit of frequency is kept
Dropping zone The upper limit of frequency decreases
Stop zone When indoor coil temperature <0°C for >80s, compressor is stopped
A (°C) 7.0
B (°C) 5.0
C (°C) 3.0
A (°F) 44.6
B (°F) 41.0
C (°F) 37.4
Indoor heat exchanger
thermistor temperature
0°C (°F)
C°C (°F)
B°C (°F)
A°C (°F)
13°C (55.4°F)
Reset zone
Up zone
Keep zone
Dropping zone
Stop zone
background
Control Specification DAMA-SM-23-021
42 Functions and Control
3.8 Heating Peak-cut Control
Outline Heat Pump Only
During heating operation, the signals being sent from the indoor unit allow the operating
frequency limitation and prevent abnormal high pressure. (The signal from the indoor unit must
be divided as follows.)
Details Conditions for Start Controlling
Judge the controlling start with the indoor heat exchanger temperature after 2 sec. from
operation start.
Control in Each Zone
The heat exchange intermediate temperature of indoor unit controls the following.
Frequency control in each zone
Zone Control
Stop zone
When indoor coil temperature stop zone, the compressor stops
Dropping zone
The upper limit of frequency decreases
Keep zone
The upper limit of frequency is kept
Up zone
The upper limit of frequency increases
Reset zone
The upper limit of frequency is cancelled
Class
09 12 18 24
A (°C) 59.0 64.0
B (°C) 55.0 54.0
C (°C) 52.0 53.0
D (°C) 50.0 51.0
E (°C) 45.0 49.0
Class
09 12 18 24
A (°F) 138.2 147.2
B (°F) 131.0 129.2
C (°F) 125.6 127.4
D (°F) 122.0 123.8
E (°F) 113.0 120.2
E°C (°F)
A°C (°F)
B°C (°F)
C°C (°F)
D°C (°F)
Heat exchanger
thermistor
temperature
Stop zone
Dropping zone
Keep zone
Up zone
Reset zone
background
DAMA-SM-23-021 Control Specification
Functions and Control 43
3.9 Outdoor Fan Control
1. Fan ON control to cool down the electrical box
The outdoor fan is turned ON when the electrical box temperature is high while the
compressor is OFF.
2. Fan OFF delay when stopped
The outdoor fan is turned OFF X seconds after the compressor stops.
3. Fan speed control for pressure difference upkeep
The rotation speed of the outdoor fan is controlled for keeping the pressure difference during
cooling operation with low outdoor temperature.
When the pressure difference is low, the rotation speed of the outdoor fan is reduced.
When the pressure difference is high, the rotation speed of the outdoor fan is controlled
as well as normal operation.
4. Fan speed control during forced cooling operation
The outdoor fan is controlled as well as normal operation during forced cooling operation.
5. Fan speed control during POWERFUL operation
The rotation speed of the outdoor fan is increased during POWERFUL operation.
6. Fan speed control during indoor unit quiet operation
The rotation speed of the outdoor fan is reduced by the command of the indoor unit quiet
operation.
7. Fan ON/OFF control when operation (cooling, dry) starts/stops
The outdoor fan is turned ON when the operation starts. The outdoor fan is turned OFF
when the operation stops.
8. Fan control when defrosting
9. Fan control when the compressor starts for heating
Model X
Class 09/12 70 seconds
Class 18/24 90 seconds
background
Control Specification DAMA-SM-23-021
44 Functions and Control
3.10 Liquid Compression Protection Function
Outline In order to increase the dependability of the compressor, the compressor is stopped according
to the outdoor temperature.
Details Operation stops depending on the outdoor temperature.
The compressor turns off under the conditions that the system is in cooling operation and
outdoor temperature is below X°C (X°F).
X refer to table below based on models
3.11 Defrost Control
Outline Heat Pump Only
Defrosting is carried out by the cooling cycle (reverse cycle). The defrosting time or outdoor
heat exchanger temperature must be more than its fixed value when finishing.
Details Conditions for Starting Defrost
The starting conditions must be made with the outdoor air temperature and heat exchanger
temperature. Under the conditions that the system is in heating operation, 6 minutes after the
compressor is started and more than 28 minutes of accumulated time pass since the start of the
operation or ending the defrosting.
Conditions for Canceling Defrost
The judgment must be made with heat exchanger temperature. (4°C-22°C) or (39.2°F to 71.6°F)
Class 09/12/18/24
X (°C) -12
Class 09/12/18/24
X (°F) 10.4
Class
Time (sec) Pulse
A B C D E F G H
09 40 120 40 630 400 300 300 350
12 40 120 40 630 400 300 300 350
18 60 120 60 570 450 400 400 400
24 60 120 60 570 450 400 400 400
Frequency
Compressor
Four way valve
Fan
Initial opening
5sec.5sec.
0Hz
0Hz
A
B
CD
PI control
E
F
G
H
ON
OFF
ON
OFF
ON
OFF
Electronic expansion
valve opening
background
DAMA-SM-23-021 Control Specification
Functions and Control 45
3.12 Electronic Expansion Valve Control
3.12.1 Summary of Electronic Expansion Valve Control
Controlling the electronic expansion valve is to ensure the reliability while optimizing the refrigerating cycle responding
to the operation status. The summary of electronic expansion valve control is shown as below.
3RZHU213RZHU6XSSO\5HVHW
,QLWLDOL]HGIXOO\FORVHGDV3RZHU6XSSO\21
(OHFWURQLFH[SDQVLRQ
YDOYHFRQWURO
DWVWDUWXS
7DUJHWGLVFKDUJH
SLSH
WHPSHUDWXUH
FRQWURO
)HHGEDFNFRQWURO
+LJKGLVFKDUJHSLSH
WHPSHUDWXUHFRQWURO
'HIURVWFRQWURO
5HKHDW
GHKXPLGLrFDWLRQ
FRQWURO
+LJKGLVFKDUJHSLSH
WHPSHUDWXUHFRQWURO
GRHVQRWIXQFWLRQ
ZKHQWKHGLVFKDUJH
SLSHWKHUPLVWRULV
GLVFRQQHFWHG
3URFHVVHVZKLOHWKHFRPSUHVVRULVRSHUDWLQJ
2SHQFRQWURO
3UHVVXUH
HTXDOL]DWLRQFRQWURO
3URFHVVZKHQ
WKHFRPSUHVVRUVWRSV
background
Control Specification DAMA-SM-23-021
46 Functions and Control
3.12.2 Full Close as Power Supply ON
When the power is turned ON, the electronic expansion valve is initialized to position the valve opening and
facilitate pressure equalization. (Prevent the compressor from being locked by start-up with differential pressure)
Processes as power supply ON
Turn the power ON, close P
ON
pulses and set the current opening at 0 pulse.
Open P
x
pulses after the full close process completed.
Process after resuming from stand-by electricity saving (suspend) mode
Set the electronic expansion valve opening at P
x
pulses after resuming from stand-by electricity saving mode.
3.12.3 Pressure Equalization Control
When the compressor is switched from ON to OFF, open the electronic expansion valve to facilitate pressure
equalization while preventing the sound produced from refrigerant flow at pressure equalization.
Summary of operation
Open the electronic expansion valve in a phased manner for 90-120 seconds when operation stop (including abnormal
stoppage) or the thermostat is turned OFF.
Fully closedopen P
x
pluses
3.12.4 Initialization as Power Supply On
The electronic expansion valve is initialized (fully closed) when the power is turned on. Then,
the valve opening position is set and the pressure is equalized.
3.12.5 Pressure Equalizing Control
When the compressor is stopped, the pressure equalizing control is activated. The electronic
expansion valve opens and the pressure is equalized.
3.12.6 Opening Limit Control
The maximum and minimum opening of the electronic expansion valve are limited.
3.12.7 Starting Operation Control
The electronic expansion valve opening is controlled when the operation starts, thus preventing
superheating or liquid compression.
Power ON
0 pulse
P
X
pulses
P
ON
pulses
=Lower limit of the
electronic expansion
valve (valve body)
stroke
Class 09 12 18 24
P
ON
700 700 720 720
P
x
400 400 450 450
Electronic
Expansion valve
opening (pulse)
09 12 18 24
Maximum 470 470 480 480
Minimum 52 52 52 52
background
DAMA-SM-23-021 Control Specification
Functions and Control 47
3.12.8 Control when the Frequency Changes
When the target discharge pipe temperature control is active, if the target frequency changes to
a specified value in a certain period of time, the target discharge pipe temperature control is
canceled and the target opening of the electronic expansion valve is changed according to the
frequency shift.
3.12.9 High Discharge Pipe Temperature Control
When the compressor is operating, if the discharge pipe temperature exceeds a certain value,
the electronic expansion valve opens and the refrigerant runs to the low pressure side. This
procedure lowers the discharge pipe temperature by cooling the compressor with refrigerant.
3.12.9-1 Determine Zones
3.12.9-2 Process for Each Zone
Dropping zone: Open the current opening by +X pulses every +Y seconds
Reset zone: Release control and shift to target discharge pipe temperature control
Class
09 12 18 24
A (°C) 102 102 101 101
B (°C) 100 100 96 96
Class
09 12 18 24
A (°F) 215.6 215.6 213.8 213.8
B (°F) 213.8 213.8 204.8 204.8
$
FRUUHFWLRQ
IDFWRU
%
FRUUHFWLRQ
IDFWRU
5HVHW]RQH
'URSSLQJ]RQH
+LJKGLVFKDUJHSLSHWHPS
FRQWUROVWDUWWHPSHUDWXUH
+LJKGLVFKDUJHSLSHWHPS
FRQWUROUHOHDVHWHPSHUDWXUH
● Compressor is operating
● Discharge pipe temp.
> 102°C (215.6°F)
A
ND
● Compressor stops
● Discharge pipe temp. < 100°C (213.8°F)
● Disconnection of discharge pipe
thermistor
OR
Dropping zone
Reset zone
Applicable Model: RK(X)09/12/18/24AXVJU
X 20 Y 30
background
Control Specification DAMA-SM-23-021
48 Functions and Control
3.12.10 Discharge Pipe Thermistor Disconnection Control
Outline The disconnection of the discharge pipe thermistor is detected by comparing the discharge pipe
temperature with the condensing temperature. If the discharge pipe thermistor is disconnected,
the electronic expansion valve opens according to the outdoor temperature and the operation
frequency, operates for a specified time, and then stops.
After 3 minutes, the operation restarts and checks if the discharge pipe thermistor is
disconnected. If the discharge pipe thermistor is disconnected, the system stops after operating
for a specified time.
If the disconnection is detected repeatedly, the system is shut down. When the compressor runs
for 60 minutes without any error, the error counter is reset.
Details Determining thermistor disconnection
When the starting control (A seconds) finishes, the detection timer for disconnection of the
discharge pipe thermistor (B seconds) starts. When the timer is over, the following adjustment is
made.
When the following condition is fulfilled, the discharge pipe thermistor disconnection is
ascertained.
For cooling mode:
Discharge pipe temperature + C°C (°F) < outdoor heat exchanger temperature
For heating mode:
Discharge pipe temperature + D°C (°F) < indoor heat exchanger temperature
When the thermistor is disconnected
When the disconnection is ascertained, the compressor continues operation for 9 minutes and
then stops.
If the compressor stops repeatedly, the system is shut down.
3.12.11 Target Discharge Pipe Temperature Control
The target discharge pipe temperature is obtained from the indoor and outdoor heat exchanger
temperature, and the electronic expansion valve opening is adjusted so that the actual
discharge pipe temperature becomes close to the target discharge pipe temperature. (Indirect
SH (superheating) control using the discharge pipe temperature)
The electronic expansion valve opening and the target discharge pipe temperature are adjusted
every A seconds. The opening degree of the electronic expansion valve is adjusted by the
following.
Target discharge pipe temperature
Actual discharge pipe temperature
Previous discharge pipe temperature
Class 09/12 18/24
A 10 10
B 720 540
C (°C) 6 6
C (°F) 42.8 42.8
Class 09/12 18/24
A 120 30
B 720 540
D (°C) 6 6
D (°F) 42.8 42.8
A (seconds) 20
SC
(Subcooling)
SH
(Superheating)
The target discharge pipe
temperature is set as to become
the target SH.
The inclination does not change
depending on the operating condition.
background
DAMA-SM-23-021 Control Specification
Functions and Control 49
3.13 Malfunctions
3.13.1 Sensor Malfunction Detection
Sensor malfunction can be detected in the following thermistors in open or short circuit.
1. Outdoor heat exchanger thermistor
2. Discharge pipe thermistor
3. Radiation fin thermistor
4. Outdoor temperature thermistor
3.13.2 Detection of Overcurrent and Overload
Outline In order to protect the inverter, an excessive output current is detected in wire labelled as No 1
at outdoor terminal block and the OL temperature is observed to protect the compressor.
Details If the inverter current exceeds A(A), the system shuts down the compressor.
If the OL (compressor body) temperature exceeds B°C (°F), the compressor stops.
During Cooling
During Heating
Class 09/12 18/24
A (A) 14.0 13.0
B (°C) 125.0 125.0
B (°F) 257.0 257.0
Class 09/12 18/24
A (A) 14.0 16.0
B (°C) 125.0 125.0
B (°F) 257.0 257.0
background
DAMA-SM-23-021
50 Part 4 Remote Controller
1. Applicable Remote Controller ...............................................................51
2. BRC52B63/64 .......................................................................................52
Part 4
Remote Controller
background
DAMA-SM-23-021 Applicable Remote Controller
Remote Controller 51
1. Applicable Remote Controller
Series Model Name Remote Controller
FTKF FTKF09/12/18/24AXVJU BRC52B64
FTXF FTXF09/12/18/24AXVJU BRC52B63
background
BRC52B63/64 DAMA-SM-23-021
52 Remote Controller
2. BRC52B63/64
FTK(X)09/12/18/24BXVJU
REMOTE CONTROLLER OVERVIEW
For cooling/heating model
SWING
TIMER
LED
CANCEL CLOCK
CANCEL
OFF
ECO+
ON
ON/OFF
SLEEP
TEMP
MODE
FAN
QUIET
POWERFUL
Display (LCD)
•Display the current
settings.
(This illustration shows the
full display of the LCD
panel, including functions
for applicable remote
controller models only).
ON/OFF Button
• Start/Stops the operation
• Blue : Cooling model
• Pink : Heatpump model
FAN Button
• Changes the operating fan
speed.
QUIET Button
• Enable / Disable QUIET
function.
Mode Button
•
Change between the
available operating modes.
ON Timer Button
• Enable / Disable and
change ON Timer setting.
CLOCK Button
• Change RTC setting.
SLEEP Button
•
Enable / Disable SLEEP
function.
UP-DOWN SWING Button
• Direct the air flow in
up-down direction.
POWERFUL Button
•
Enable / Disable
POWERFUL function.
ECO+ Button
•
Enable / Disable ECO+
function.
OFF Timer Button
• Enable / Disable and
change OFF Timer setting.
Temperature Setting Button
• Increase / Decrease the
temperature setting.
IR Signal Transmitter
• To enable signal
transmission, direct the
transmitter at the indoor
unit.
Note that in condition
where there is an obstacle
that blocks between the
transmitter and the indoor
unit, signal transmission
might not be successful.
LED Button
• Change the indication
display.
background
DAMA-SM-23-021
Part 5 Service Diagnosis 53
1. General Problem Symptoms and Check Items .....................................54
2. Troubleshooting with LED .....................................................................55
2.1 Indoor Unit..............................................................................................55
2.2 Outdoor Unit ...........................................................................................55
3. Error Diagnosis .....................................................................................56
3.1 To enter error diagnosis .........................................................................56
4. Troubleshooting ....................................................................................57
4.1 Error Codes and Description ..................................................................57
4.2 Indoor Unit PCB Abnormality .................................................................59
4.3 Freeze-up Protection Control .................................................................60
4.4 Indoor Fan Motor (DC Motor) or Related Abnormality ...........................61
4.5 Thermistor or Related Abnormality (Indoor Unit)....................................62
4.6 Thermistor or Related Abnormality (Indoor Unit)....................................63
4.7 Low-voltage Detection or Over-voltage Detection..................................65
4.8 Signal Transmission Error (Between Indoor Unit and Outdoor Unit)......67
4.9 Installation error......................................................................................70
4.10 Outdoor Unit PCB Abnormality...............................................................73
4.11 Actuation of High Pressure Switch .........................................................74
4.12 OL Activation (Compressor Overload) ...................................................75
4.13 OL Activation (Compressor Overload) or HPS Activation (High Pressure
Switch)....................................................................................................... 77
4.14 Compressor Lock ...................................................................................79
4.15 DC Fan Lock ..........................................................................................80
4.16 Input Overcurrent Detection ...................................................................81
4.17 Discharge Pipe Temperature Control.....................................................82
4.18 High Pressure Control in Cooling ...........................................................83
4.19 Compressor System Sensor Abnormality ..............................................85
4.20 Position Sensor Abnormality ..................................................................86
4.21 Thermistor or Related Abnormality (Outdoor Unit).................................87
4.22 Electrical Box Temperature Rise............................................................89
4.23 Radiation Fin Temperature Rise ............................................................90
4.24 Output Overcurrent Detection ................................................................92
4.25 Four Way Valve Abnormality..................................................................94
5. Actuator Check......................................................................................96
5.1 Thermistor Resistance Check ................................................................96
5.2 Power Supply Waveform Check.............................................................97
5.3 Electronic Expansion Valve Check.........................................................97
5.4 Four Way Valve Performance Check .....................................................98
5.5 Inverter Unit Refrigerant System Check.................................................99
5.6 Rotation Pulse Check on the Outdoor Unit PCB ....................................99
5.7 Installation Condition Check.................................................................101
5.8 Discharge Pressure Check...................................................................101
5.9 Outdoor Fan System Check .................................................................102
5.10 Main Circuit Short Check......................................................................102
5.11 Power Module Check ...........................................................................104
Part 5
Service Diagnosis
background
General Problem Symptoms and Check Items DAMA-SM-23-021
54 Service Diagnosis
1. General Problem Symptoms and Check Items
Symptom Check Item Details
Reference
Page
The unit does not operates. Check the power supply. Check if the rated voltage is supplied. —
Check the type of the indoor unit. Check if the indoor unit type is compatible
with the outdoor unit.
—
Check the outdoor temperature. Cooling operation is not available when the
outdoor temperature is out of the operation
limit. Check the reference page for the
operation limit.
119
Diagnose with remote controller
indication
— 57
Check the remote controller
addresses.
Check if address settings for the remote
controller and indoor unit are correct.
—
Operation sometimes stops. Check the power supply. A power failure of 2 to 10 cycles can stop air
conditioner operation. (Operation lamp OFF)
—
Check the outdoor temperature. Cooling operation is not available when the
outdoor temperature is out of the operation
limit. Check the reference page for the
operation limit.
119
Diagnose with remote controller
indication.
— 57
The unit operates but does
not cool.
Check for wiring and piping errors in
the connection between the indoor
and outdoor units.
— —
Check for thermistor detection errors. Check if the thermistor is mounted securely. —
Check for faulty operation of the
electronic expansion valve.
Set the unit to cooling operation, and check
the temperatures of the liquid pipe to see if
the electronic expansion valve works.
—
Diagnose with remote controller
indication.
— 57
Diagnose by service port pressure
and operating current.
Check for refrigerant shortage.
—
Large operating noise and
vibrations
Check the output voltage of the power
module.
— 104
Check the power module. — —
Check the installation condition. Check if the required spaces for installation
(specified in the installation manual) are
provided.
—
background
DAMA-SM-23-021 Troubleshooting with LED
Service Diagnosis 55
2. Troubleshooting with LED
2.1 Indoor Unit
Operation Lamp The operation lamp blinks when any of the following errors is detected.
1. A protection device of the indoor or outdoor unit is activated, or the thermistor malfunctions.
2. A signal transmission error occurs between the indoor and outdoor units.
In either case, conduct the diagnostic procedure described in the following pages.
2.2 Outdoor Unit
The outdoor unit has a green LED (LED A) on the PCB.
When the microcomputer works in order, the LED A blinks.
Refer to pages 117, 118 for the location of LED A
ON/OFF
switch
LED INDICATION LIGHTS
background
Error Diagnosis DAMA-SM-23-021
56 Service Diagnosis
Notes
3. Error Diagnosis
3.1 To enter error diagnosis
GV : Press [Timer CANCEL] to scroll to next
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To return to the normal mode.
GV : Press [Timer CANCEL] for 5 seconds
When the remote controller is left untouched for 60 seconds, it also returns to the normal mode.
TIMER
CANCEL
OFF
°C
GV
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 57
4. Troubleshooting
4.1 Error Codes and Description
Displayed only when the system is shut down.
Error
Codes
Description Reference Page
System
00 Normal condition -
U2 Low-voltage detection or over-voltage detection 65
U4 Signal transmission error (between indoor unit and outdoor unit) 67
UA Installation error (between indoor unit and outdoor unit) 70
Indoor Unit
A1 Indoor unit PCB abnormality 59
A5 Freeze-up protection control 60
A6 Indoor fan motor (DC motor) or related abnormality 61
C4 Indoor heat exchanger thermistor or related abnormality 62
C9 Room temperature thermistor or related abnormality 63
Outdoor Unit
E1 Outdoor unit PCB abnormality 73
E3 Actuation of high pressure switch 74
E5
OL activation (compressor overload) 75
OL activation (compressor overload) or HPS activation (high
pressure switch)
77
E6
Compressor lock 79
E7
DC fan lock 80
E8 Input overcurrent detection 81
F3 Discharge pipe temperature control 82
F6 High pressure control in cooling 83
EA Four way valve abnormality 94
H0 Compressor sensor system abnormality 85
H6 Position sensor abnormality 86
H9 Outdoor temperature thermistor or related abnormality 87
J3
Discharge pipe thermistor or related abnormality 87
J6 Outdoor heat exchanger thermistor or related abnormality 87
L3 Electrical box temperature rise 89
L4 Radiation fin temperature rise 90
L5 Output overcurrent detection 92
P4 Radiation fin thermistor or related abnormality 87
background
Troubleshooting DAMA-SM-23-021
58 Service Diagnosis
Error Code Definition
Error Code Checklist Meaning
00
Normal
A1
Indoor PCB error
A3 Drain pump abnormal
A5
Antifreeze
A6
Indoor fan motor abnormal
AH Electrical air cleaner abnormal
C4
Indoor heat exchanger (1) thermistor short / open
C5 Indoor heat exchanger (2) thermistor short / open
C7 Louver limit switch error
C9
Indoor room thermistor short / open
E1
Outdoor PCB error
E3
High pressure protection
E4 Low pressure protection
E5
Compressor motor lock / compressor overload
E6
Compressor start-up error
E7
Outdoor DC fan motor lock
E8
AC input overcurrent
E9 EXV error
EA
4 way valve error
F3
Discharge pipe overheat
F6
Heat exchanger overheat
H0
Compressor sensor system error
H3
High pressure switch error
H6
Compressor feedback detection error
H7 Fan motor overload / overcurrent / sensor abnormal
H8 AC current sensor error
H9
Outdoor air thermistor short / open
J1 Pressure sensor error
J3
Compressor discharge pipe thermistor short / open / misplaced
J5 Suction pipe thermistor short / open
J6
Outdoor heat exchanger thermistor short / open
J7 Subcooling heat exchanger thermistor short / open
J8 Liquid pipe thermistor short / open
J9 Gas pipe thermistor short / open
L1 Inverter outdoor PCB error
L3
Outdoor control box overheat
L4
Heat sink overheat
L5
IPM error / IGBT error
L8 Inverter compressor overcurrent
L9 Compressor overcurrent prevention
LC Communication error (outdoor control PCB and inverter PCB)
P1 Open phase or voltage unbalance
P4
Heat sink thermistor short / open
PJ Capacity setting error
U0 Insufficient gas
U2
DC voltage out of range
U4
Communication error
U7 Communication error (outdoor control PCB and IPM PCB)
UA
Installation error (wrong combination of ID and OD units /
wrong or defective ID/OD PCB installed)
UF Piping & wiring installation mismatch / wrong wiring / insufficient gas
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 59
4.2 Indoor Unit PCB Abnormality
Error Code A1
Description Indoor unit ON/OFF switch abnormality or indoor control PCB EEPROM error.
Method of Error
Detection
The system checks if the ON/OFF switch works properly.
Error Decision
Conditions
ON/OFF switch malfunction.
Possible root
cause
1. Defective indoor unit ON/OFF switch.
2. Defective indoor unit control PCB (EEPROM).
Troubleshooting
Caution
YES
YES
Wait 2 secs
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Maintain unit
power supply on
Press the ON/OFF
switch on unit outer
casing
Press the ON/OFF
switch again directly
from display PCB
Replace the indoor unit
PCB (Control PCB) and
replace the Display PCB back
to it's original.
Ensure no obstruction/
blockage/ improper assembly
of the unit outer casing
switch area pressing against
the unit display PCB ON/OFF
Replace the
Display PCB
of the unit.
Completed
Completed
Does
error code
repeat?
Does
error code
repeat?
Remove unit
outer casing
Assemble outer casing
back to unit
YES
Is there 1 "BEEP"
sound and/ or LED light
blinking continously
after pressing switch?
NO
NO
background
Troubleshooting DAMA-SM-23-021
60 Service Diagnosis
Reference
Note
4.3 Freeze-up Protection Control
Error Code A5
Method of Error
Detection
During cooling operation, the freeze-up protection control (operation halt) is activated according
to the temperature detected by the indoor heat exchanger thermistor.
High pressure control (heat pump model only).
During heating operations, the temperature detected by the indoor heat exchanger.
Thermistor is used for the high pressure control (stop, outdoor fan stop, etc.).
Error Decision
Conditions
During cooling operation, the indoor heat exchange temperature is below 0°C (32°F).
High pressure control
During heating operations, the temperature detected by the indoor heat exchanger thermistor is
above 61°C (141.8°F).
Supposed
Causes
Indoor Short-circuited air
Clogged air filter of the indoor unit
Dust accumulation on the indoor heat exchanger
Defective indoor heat exchanger thermistor
Defective indoor unit PCB
Troubleshooting
Check No.01 Refer to P.96
When replacing the defective thermistor(s), replace the thermistor as ASSY.
NO
NO
NO
Check No. 01
Check the indoor heat exchanger
thermistor.
YES
YES
YES
YES
NO
Provide sufficient air passage.
Clean the air filter.
Clean the indoor heat
exchanger.
Replace the indoor unit PCB
(control PCB).
Replace the indoor heat
exchanger thermistor.
As
described in the
thermistor characteristic
chart?
Check the air filter.
Check the dust accumulation on
the indoor heat exchanger.
Is there any short circuit?
Dirty?
Dirty?
Check the air passage.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 61
4.4 Indoor Fan Motor (DC Motor) or Related Abnormality
Error Code A6
Description Abnormality of indoor fan motor or indoor unit PCB.
Objectives 1. To check on the connection and functionality of indoor fan motor.
2. To check on the connection and functionality of indoor unit PCB.
Method of Error
Detection
The rotation speed detected by the Hall IC during fan motor operation is used to determine
abnormal fan motor operation.
Error Decision
Conditions
The detected rotation speed does not reach the demanded rotation speed of the target tap, and
is less than 50% of the maximum fan motor rotation speed.
Possible Root
Causes
1. Indoor fan motor winding short, or the motor lead wire broken.
2. Indoor PCB faulty.
Troubleshooting
Cautio
n
Remove the
physical blockage.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Turn off power supply and rotate fan by hand.
Check any blockage of the fan.
Complete.
Complete.
Complete.
Correct the
connection.
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
Does the fan
rotate smoothly without
any jam?
Check the connection of fan motor connector
that connected to indoor unit PCB.
Replace the indoor unit PCB and change
back to original motor. Turn on power.
Does it connect properly?
Blockage
on the fan?
Is error repeated?
Is error repeated?
Replace the indoor fan motor and turn on power.
Replace new indoor motor and turn on power.
background
Troubleshooting DAMA-SM-23-021
62 Service Diagnosis
Reference
Note
4.5 Thermistor or Related Abnormality (Indoor Unit)
Error Code C4
Description Abnormality of indoor coil thermistor or indoor unit PCB.
Objectives 1. To check on the connection and functionality of indoor coil thermistor.
2. To check on the connection and functionality of indoor unit PCB.
Method of Error
Detection
The temperature detected by the thermistors determine thermistor errors.
Error Decision
Conditions
The resistance of the thermistor is out of range (0 Ω or Ω)
Supposed
Causes
Disconnection of connector
Defective thermistor(s)
Defective indoor unit PCB
Troubleshooting
C4 : Indoor heat exchanger thermistor
Check No.01 Refer to P.96
When replacing the defective thermistor(s), replace the thermistor as ASSY.
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Correct the connection.
NO
Replace the defective coil thermistor.
NO
Replace the indoor unit PCB (control PCB).
YES
YES
Does it connect properly?
Check the
resistance value whether match with
ambient temperature.
Check No.01
Check the coil thermistor resistance value.
Check the connection of coil thermistor's
connector that connected to indoor unit PCB.
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 63
Reference
4.6 Thermistor or Related Abnormality (Indoor Unit)
Error Code C9
Description Abnormality of indoor room temperature thermistor or indoor unit PCB.
Objectives 1. To check on the connection and functionality of indoor room temperature thermistor.
2. To check on the connection and functionality of indoor unit PCB.
Method of Error
Detection
The temperature detected by the thermistors determine thermistor errors.
Error Decision
Conditions
The resistance of the thermistor is out of range (0 Ω or Ω)
Supposed
Causes
Disconnection of connector
Defective thermistor(s)
Defective indoor unit PCB
Troubleshooting
C9 : Room temperature thermistor
Check No.01 Refer to P.64
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Correct the connection.
NO
For RA Models:
- Replace the defective Display PCB.
NO
Replace the indoor unit PCB (control PCB).
YES
YES
Is it connected properly?
Check the indoor room
thermistor's resistance value whether
match with ambient
temperature.
Check No.01
Check the indoor room temperature thermistor's resistance value
(Refer to Figure 1)
Check the connection of:
For RA Models:
a) Display PCB
background
Troubleshooting DAMA-SM-23-021
64 Service Diagnosis
Note
Check No.01 Measure the resistance of each thermistor using multimeter.
The resistance values are defined by below table.
If the measured resistance value does not match the listed value, the Display PCB or thermistor
must be replaced.
Disconnect the connector of thermistor ASSY from the PCB to measure the resistance
between the pins using multimeter.
To check the soldered thermistor on the Display PCB (applicable for all RA Indoor Inverter
Models) disconnect the PCB from other PCB/parts, and measure the resistance as shown in
Figure 1.
Figure 1
To check the thermistor ASSY, measure the resistance between the both ends of the
thermistor as shown below.
Thermistor's Resistance Value
When replacing the defective thermistor(s), replace the thermistor as ASSY.
Illustration Description Models Involved
For all RA Indoor Inverter Models
Remove the Display PCB from it's
holder, turn it to the back and
measure the point, CN_ROOM
(boxed in red).
FTKU/FTKH
Remove the Display PCB from it's
holder, turn it to the back and
measure the point, CN_ROOM
(boxed in red).
FTKF series
Remove the Display PCB from it's
holder, turn it to the back and
measure the point, CN_ROOM
(boxed in red).
Entry Step 3
T (°C) T (°F) R
range
( T (°C) T (°F) R
range
(
20.0 68.0 12.01 - 12.31 28.0 82.4 8.82 - 9.02
21.0 69.8 11.55 - 11.82 29.0 84.2 8.49 - 8.69
22.0 71.6 11.11 - 11.36 30.0 86.0 8.17 - 8.37
23.0 73.4 10.69 - 10.92 31.0 87.8 7.87 - 8.07
24.0 75.2 10.29 - 10.50 32.0 89.6 7.58 - 7.78
25.0 77.0 9.90 - 10.10 33.0 91.4 7.31 - 7.50
26.0 78.8 9.52 - 9.72 34.0 93.2 7.04 - 7.23
27.0 80.6 9.16 - 9.36 35.0 95.0 6.79 - 6.98
CN_ROOM
Multimeter
Resistance range
Thermistor ASSY Soldered thermistor
Multimeter
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 65
4.7 Low-voltage Detection or Over-voltage Detection
Error Code U2
Method of Error
Detection
Low-voltage detection:
An abnormal voltage drop is detected by the DC voltage detection circuit.
Over-voltage detection:
An abnormal voltage rise is detected by the DC over-voltage detection circuit.
Error Decision
Conditions
Low-voltage detection:
The voltage detected by the DC voltage detection circuit is below 180 - 196 V (depending on
the model).
The compressor stops if the error occurs, and restarts automatically after 3-minute standby.
Over-voltage detection:
An over-voltage signal is fed from the over-voltage detection circuit to the microcomputer.
The compressor stops if the error occurs, and restarts automatically after 3-minute standby.
Supposed
Causes
Power supply voltage out of specification
Defective DC voltage detection circuit
Defective over-voltage detection circuit
Defective PAM control part
Disconnection of compressor harness
Short circuit inside the fan motor winding
Noise
Momentary drop of voltage
Momentary power failure
Defective outdoor unit PCB
background
Troubleshooting DAMA-SM-23-021
66 Service Diagnosis
Troubleshooting
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Correct the power supply.
NO
Reconnect the wires.
YES
YES
YES
NO
NO
NO
NO
NO
NO
(Precaution before turning on the power again)
Make sure the power has been off for at least 30 seconds.
Replace the outdoor unit
PCB (main PCB).
Check the interconnecting wire
and ensure the difference of
voltage between indoor and outdoor
is within 5V.
YES
YES
Check for the below mentioned
factors.
Long term power quality factors
• Noise
• Power supply distortion
YES
Loose or disconnected?
Is error
repeated?
Complete.
Turn on the power.
System restarted?
Is the voltage
measured within ±10% from
the rated value?
Is the difference of
voltage measured between indoor and
outdoor is over 5V?
Retry again at least
3 times. System restarted?
(You may stop if the system has
been restarted.)
Check the power supply voltage.
Check the condition of fan motor.
Check the connection of the compressor wires.
Manually turn the fan
motor by hand. Is the rotation of
fan motor stucked?
Check the difference between indoor and
outdoor power supply voltage during
unit operation.
*Remark (for local market): Measure the voltage
at Live- Neutral terminal.
Replace the
outdoor motor.
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 67
4.8 Signal Transmission Error (Between Indoor Unit and
Outdoor Unit)
Error Code U4
Method of Error
Detection
The signal transmission data received from the outdoor unit is checked whether it is normal.
Error Decision
Conditions
The data sent from the outdoor unit cannot be received normally, or the content of the data is
abnormal.
Possible Root
Cause
1. Power Supply Abnormal
2. Wrong wiring of connecting wires / wire breaking
3. Defective of Indoor/ Outdoor PCB
background
Troubleshooting DAMA-SM-23-021
68 Service Diagnosis
Troubleshooting
Cautio
n
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Is there a
voltage fluctuation within
±10% from the rated value?
(*Local -> Rated Value:
min: 198V to max: 264V)
Does error
repeat after completed checking
and action based on the
summary table?
Check the power supply
1. Check power supply3. Check PCB 2. Check Wiring
Turn off the power supply
Check Connecting Wires
Check voltage between Sig - No.2
Check outcome and take action based on the
Wrong Wiring Combination table under Extra Info
Are connecting wires same
as wiring diagram?
Are there any
wire loose on terminal strip?
Pull the connecting wire slightly on both
ID and/or OD terminal strip to
verify tightness.
Are there
any wire loose on either
ID or/and OD PCB?
Pull all the internal wiring slightly
on both PCB to verify
tightness.
Change Indoor PCB & turn on power supply
Change Indoor PCB
Replace the original Indoor PCB &
change the Outdoor PCB
YES
YES
YES
YES
YES
YES
NO
NO
Does
the error code
repeat?
Complete
Complete
Complete
Complete
Correct the
power supply
Correct the
connection
based on
wiring diagram
NO
NO
Does
the error code
repeat?
YES
YES
YES
YES
Tighten the
loose wires on
terminal strip
NO
Does
the error code
repeat?
YES
Correct the
connection on
any loose
wiring on
the PCB
NO
Complete
NO
Complete
NO
Complete
NO
NO
NO
Does
the error code
repeat?
Does
the error code
repeat?
Does
the error code
repeat?
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 69
Extra Info:
Wrong Wiring Combination Table
No Combination
Correct Wiring1
2
3
4
5
5 - 20 VAC–
0 VAC
or
230 VAC
0 VAC
230 VAC
230 VACU4U4
U4
U4 U4
U4
Wrong Wiring
Correct the wiring as
per wiring diagram
Action to be taken
Voltage at
2-3/SIG
Model
FTKU / FTKH FTKF
–
–
–
background
Troubleshooting DAMA-SM-23-021
70 Service Diagnosis
4.9 Installation error
Error Code UA
Method of Error
Detection
The supply power is detected for its requirements (pair type is different from multi type) by the
indoor/outdoor transmission signal.
Error Decision
Conditions
The pair type and multi type are interconnected.
Possible root
cause
1. Wrong wiring of connecting wires.
2. Model coupling error.
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 71
Troubleshooting
Cautio
n
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Are indoor and
outdoor model combination correct
based on IM?
Check connecting wires
1. Check Wiring3. Check PCB
2. Check model coupling
(Indoor-Outdoor)
Check the combination of the indoor
and outdoor unit.
(Refer IM for the correct combination set)
Are connecting wires same
as wiring diagram?
Are there any
wire loose on terminal strip?
Pull the connecting wire slightly on both
ID and/or OD terminal strip to
verify tightness.
Are there
any wire loose on either
ID or/and OD PCB?
Pull all the internal wiring slightly
on both PCB to verify
tightness.
Check the part numbers of the indoor &
outdoor unit PCB
Check both PCB part numbers based on
model Part List
Change Indoor PCB & turn on power supply
Change Indoor PCB
Replace the original Indoor PCB &
change the Outdoor PCB
YES
YES
YES
YES
YES
Complete
Complete
Complete
Correct the
connection
based on
wiring diagram
NO
NO
NO
NO
Does
the error code
repeat?
YES
YES
YES
YES
Tighten the
loose wires on
terminal strip
NO
Does
the error code
repeat?
YES
Correct the
connection on
any loose
wiring on
the PCB
NO
Complete
NO
Complete
NO
NO
NO
Does
the error code
repeat?
Complete
Match back
the correct
compatible
models based
on IM
Complete
Change to
correct PCB
according
to part list
NO
Does
the error code
repeat?
Does
the error code
repeat?
Does
the error code
repeat?
background
Troubleshooting DAMA-SM-23-021
72 Service Diagnosis
Extra Info:
No Combination
Correct Wiring1
2
3
4
5 - 20 VAC–
0 VAC
or
230 VAC
230 VAC
~50 VAC
or
230 VAC
UA
UA UA
UA
Wrong Wiring
Correct the wiring as
per wiring diagram
Action to be taken
Voltage at
2-3/SIG
Model
FTKU / FTKH FTKF
UA
–
UA
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 73
4.10 Outdoor Unit PCB Abnormality
Error Code E1
Method of Error
Detection
The system checks if the microcomputer is working in order.
The system checks if the zero-cross signal comes in properly.
Error Decision
Conditions
The microcomputer program runs out of control.
The zero-cross signal is not detected.
Supposed
Causes
Defective outdoor unit PCB
Noise
Momentary drop of voltage
Momentary power failure
Troubleshooting
YES
NO
NO
YES
Replace the outdoor unit PCB
(main PCB).
Ground the system.
The cause can be external
factors other than malfunction.
Investigate the cause of noise.
Turn on the power.
Error again?
Check if the outdoor unit is
grounded.
Grounded?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
74 Service Diagnosis
4.11 Actuation of High Pressure Switch
Error Code E3
Applicable
Models
Class 18/24
Method of Error
Detection
Abnormality is detected when the contact of the high pressure switch opens.
Error Decision
Conditions
High pressure switch (S1PH) activating pressure: 4.15 MPa
High pressure switch (S1PH) recovery pressure: 3.2 MPa
Supposed
Causes
Actuation of high pressure switch (S1PH)
Closed stop valve
Disconnection of connector S40
Disconnection of 2 terminals of high pressure switch (S1PH)
Defective outdoor unit PCB
Broke S1PH harness
Defective high pressure switch (S1PH)
Troubleshooting
NO
NO
YES
YES
High
pressure switch
connector S40 properly
connected?
Resistance
Resistance
Nearly 0 Ω
Stop valve open?
Disconnect the connector
S40 from the PCB.
Disconnect the 2 terminals of
the high pressure switch
(S1PH).
Check
the resistance
between the pins 1-2 on
the connector
S40.
Open the stop valve
Reconnect the connector.
Replace the outdoor unit PCB
(main PCB).
Nearly 0 Ω
Check
the resistance
between the the 2
terminals of the high
pressure switch
(S1PH).
Replace the harness for the high
pressure switch.
Replace the high pressure switch
(S1PH).
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 75
4.12 OL Activation (Compressor Overload)
Error Code E5
Applicable
Models
Class 18/24
Description OL activation (compressor overload).
Method of Error
Detection
A compressor overload is detected through compressor OL.
Error Decision
Conditions
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Possible Root
Causes
1. Disconnection of discharge pipe thermistor
2. Defective discharge pipe thermistor
3. Disconnection of connector S40
4. Disconnection of 2 terminals of OL (Q1L)
5. Defective OL (Q1L)
6. Broken OL harness
7. Defective electronic expansion valve or coil
8. Defective four way valve or coil
9. Defective outdoor unit PCB
10.Refrigerant shortage
11.Water mixed in refrigerant
12.Defective stop valve
background
Troubleshooting DAMA-SM-23-021
76 Service Diagnosis
Reference
Reference
Reference
Note
Troubleshooting
Check No.01 Refer to P.96
Check No.12 Refer to P.97
Check No.14 Refer to P.99
When replacing the defective thermistor(s), replace the thermistor as ASSY.
YES
NO
YES
NG
NO
OK
Check the thermistorsCheck No. 01
Check No. 12
Check No. 14
• Connector S40
• 2 terminals of OL (Q1L)
• Discharge pipe thermistor
NG
NG applicable to FTK/FTX (mode)
NG
Replace the OL harness.
Replace the OL (Q1L)
OK
OK
OK
Resistance
Resistance
Nearly 0 Ω
Nearly 0 Ω
Discharge
pipe thermistor
disconnected?
Connectors are
properly connected?
Disconnect the connector S40
from the PCB.
Check
the resistance
between the 2 terminals on
connector S40.
Check the electronic
expansion valve.
Check the refrigerant
line.
Check the four way
valve
Disconnect the 2 terminals
of the OL (Q1L).
Check the
resistance
between the 2
terminals of the OL
(Q1L).
• Refrigerant shortage
• Water mixed
• Stop valve
Insert the thermistor in
position.
Replace the discharge pipe
thermistor.
Connect the connectors
properly.
Replace the four way valve or the
coil.
Replace the outdoor unit PCB
(main PCB).
Refer to the refrigerant line
check procedure.
Replace the outdoor unit PCB
(main PCB).
Replace the electronic expansion
valve or the coil
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 77
4.13 OL Activation (Compressor Overload) or HPS Activation
(High Pressure Switch)
Error Code E5
Applicable
Models
Class 09 and Class 12
Description OL activation (compressor overload).
Method of Error
Detection
A compressor overload is detected through compressor OL.
Abnormality is detected when the contact of the high pressure switch opens.
Error Decision
Conditions
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Possible Root
Causes
1. Disconnection of discharge pipe thermistor
2. Defective discharge pipe thermistor
3. Disconnection of connector S40
4. Disconnection of 2 terminals of OL (Q1L)
5. Defective OL (Q1L)
6. Broken OL harness
7. Defective electronic expansion valve or coil
8. Defective four way valve or coil
9. Defective outdoor unit PCB
10.Refrigerant shortage
11.Water mixed in refrigerant
12.Defective stop valve
13.Defective outdoor unit PCB
14.Refrigerant shortage
15.Water mixed in refrigerant
16.Defective stop valve
background
Troubleshooting DAMA-SM-23-021
78 Service Diagnosis
Reference
Reference
Reference
Note
Troubleshooting
Check No.01 Refer to P.96
Check No.12 Refer to P.97
Check No.14 Refer to P.99
When replacing the defective thermistor(s), replace the thermistor as ASSY.
YES
NO
YES
NG
NO
OK
Check the thermistors
Stop valve open?
Check No. 01
Check No. 12
Check No. 14
• Connector S40
• 2 terminals of OL (Q1L)
• Discharge pipe thermistor
* Indoor heat exchanger thermistor
* Outdoor heat exchanger thermistor
NG
NG applicable to FTK/FTX (mode)
NG
Replace the harness.
Replace the OL (Q1L).
OK
OK
OK
Resistance
Resistance
Replace the HPS (S1PH).
Resistance
Nearly 0 Ω
Nearly 0 Ω
Discharge
pipe thermistor
disconnected?
Connectors are
properly connected?
Disconnect the connector S40
from the PCB.
Check
the resistance
between the 2 terminals
on connector S40.
Check the electronic
expansion valve.
Check the refrigerant
line.
Check the four way
valve
Disconnect the 2 terminals of the OL (Q1L).
Disconnect the 2 terminals of the HPS (S1PH).
Check the
resistance between the
2 terminals of the
OL (Q1L).
Check the
resistance between the
2 terminals of the
HPS (S2PH).
* Refrigerant shortage
* Refrigerant overfill
* Water mixed
* Stop valve
Insert the thermistor in
position.
NO
Open the valve.
Replace the discharge pipe
thermistor.
Connect the connectors
properly.
Replace the four way valve or the
coil.
Replace the outdoor unit PCB
(main PCB).
Refer to the refrigerant line
check procedure.
Replace the outdoor unit PCB
(main PCB).
Replace the electronic expansion
valve or the coil
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 79
Reference
4.14 Compressor Lock
Error Code E6
Description Compressor lock.
Method of Error
Detection
A compressor lock is detected by checking the compressor running condition through the
position detection circuit.
Error Decision
Conditions
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 11 minutes without any other error.
Supposed
Causes
Closed stop valve
Compressor locked
Disconnection of compressor harness
Troubleshooting
Check No.12 Refer to P.97
Stop valve closed?
YES
NO
YES
NO
YES
NO
Open the stop valve.
System shut
down after errors repeated
several times?
Emergency
stop without compressor
running?
Turn off and turn on the power
to restart the system
Check the electronic expansion
valve coil. Go to Check No. 12.
Replace the compressor. /
outdoor unit PCB (main PCB)
Replace the compressor. /
outdoor unit PCB (main PCB)
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
80 Service Diagnosis
Reference
4.15 DC Fan Lock
Error Code E7
Method of Error
Detection
An error is determined with the high-voltage fan motor rotation speed detected by the Hall IC.
Error Decision
Conditions
The fan does not start in about 30 ~ 60 seconds (depending on the model) even when the
fan motor is running.
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 11 minutes without any other error
Supposed
Causes
Disconnection of the fan motor
Foreign matter stuck in the fan
Defective fan motor
Defective outdoor unit PCB
Troubleshooting
Check No.16 Refer to P.99
YES
YES
NO
YES
NO
NO
YES
NO
Turn on the power.
Rotate the fan.
Turn off the power and
reconnect the connector.
Remove the foreign
matters.
Replace the outdoor fan
motor.
Replace the outdoor unit
PCB (main PCB).
Replace the outdoor fan
motor.
Fan motor connector
disconnected?
Foreign matters in or
around the fan?
Fan rotates
smoothly?
Check No. 16
Check the rotation pulse input on
the outdoor unit PCB (main PCB).
Pulse signal generated?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 81
Reference
Reference
4.16 Input Overcurrent Detection
Error Code E8
Description Input Overcurrent Detection
Method of Error
Detection
An input overcurrent is detected by checking the input current value with the compressor
running.
Error Decision
Conditions
T
he current exceeds 13 ~ 16 A (depending on the model) for 2.5 seconds with the compressor running.
The upper limit of the current decreases when the outdoor temperature exceeds a certain level.
Supposed
Causes
Outdoor temperature out of operation range
Defective compressor
Defective power module
Defective outdoor unit PCB
Short circuit
Troubleshooting
Cautions: Be sure to turn off the power switch before connecting or disconnecting connectors, or parts
may be damaged.
An input overcurrent may result from wrong internal wiring. If the system is interrupted by an
input overcurrent after the wires have been disconnected and reconnected for part
displacement, check the wiring again.
Check No.17 Refer to P.101
Check No.18 Refer to P.101
Check No. 17
Check the installation condition.
Check No. 18
Check the discharge pressure.
Start operation and measure the
Input current.
Input current flowing
above its stop level?
Replace the outdoor
unit PCB (main PCB).
YES
NO
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
82 Service Diagnosis
Reference
Reference
Reference
Note
4.17 Discharge Pipe Temperature Control
Error Code F3
Method of Error
Detection
An error is determined with the temperature detected by the discharge pipe thermistor.
Error Decision
Conditions
If the temperature detected by the discharge pipe thermistor rises above A°C (°F), the
compressor stops.
The error is cleared when the discharge pipe temperature has dropped below B°C (°F).
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Supposed
Causes
Defective discharge pipe thermistor
(Defective outdoor heat exchanger thermistor or outdoor temperature thermistor)
Defective electronic expansion valve or coil
Refrigerant shortage
Water mixed in refrigerant
Defective stop valve
Defective outdoor unit PCB
Troubleshooting
Check No.01 Refer to P.96
Check No.12 Refer to P.97
Check No.14 Refer to P.99
When replacing the defective thermistor(s), replace the thermistor as ASSY.
Class
09/12 18/24
Maximum Limit, A (°C) 110 118
Reset Limit, B (°C) 88 81
Class
09/12 18/24
Maximum Limit, A (°F) 230 231.8
Reset Limit, B (°F) 190.4 165.2
NG
OK
OK
OK
NG
NG
∗ Discharge pipe thermistor
∗ Outdoor heat exchanger thermistor
∗ Outdoor temperature thermistor
∗ Refrigerant shortage
∗ Water mixed
∗ Stop valve
Check No. 01
Check the thermistors.
Check No. 14
Check the refrigerant
line.
Check No. 12
Check the electronic
expansion valve.
Replace the defective
thermistor(s).
Replace the electronic
expansion valve or the coil.
Refer to the refrigerant line
check procedure.
Replace the outdoor unit
PCB (main PCB).
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 83
4.18 High Pressure Control in Cooling
Error Code F6
Method of Error
Detection
High-pressure control (operation halt, frequency drop, etc.) is activated in cooling mode if the
temperature sensed by the outdoor heat exchanger thermistor exceeds the limit.
Error Decision
Conditions
The temperature sensed by the outdoor heat exchanger thermistor rises above A°C (°F).
The error is cleared when the temperature drops below B°C (°F).
Supposed
Causes
Installation space not large enough
Dirty outdoor heat exchanger
Defective outdoor fan motor
Defective stop valve
Defective electronic expansion valve or coil
Defective outdoor heat exchanger thermistor
Defective outdoor unit PC
Troubleshooting
Class
09/12 18/24
Maximum Limit, A (°C) 58 61
Reset Limit, B (°C) 48 53
Class
09/12 18/24
Maximum Limit, A (°F) 136.4 141.8
Reset Limit, B (°F) 118.4 127.4
Replace the outdoor fan
motor.
Reconnect the connector or
fan motor lead wires.
Replace the stop valve.
Replace the outdoor heat
exchanger thermistor.
Replace the outdoor unit
PCB (main PCB).
Replace the electronic
expansion valve or the coil.
Replace the outdoor unit
PCB (main PCB).
Change the installation
location or direction.
Clean the outdoor heat
exchanger.
Check the installation space.
NG
OK
OK
NG
NG
OK
OK
OK
NG
NG
Check No. 19
Check the outdoor fan.
Check No. 18
Check the discharge
pressure.
Check No. 12
Check the electronic
expansion valve.
Check No. 17
Check the installation
condition.
Check No. 01
Check the outdoor heat
exchanger thermistor.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
84 Service Diagnosis
Reference
Reference
Reference
Reference
Reference
Note
Check No.01 Refer to P.96
Check No.12 Refer to P.97
Check No.17 Refer to P.101
Check No.18 Refer to P.101
Check No.19 Refer to P.102
When replacing the defective thermistor(s), replace the thermistor as ASSY.
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 85
4.19 Compressor System Sensor Abnormality
Error Code H0
Method of Error
Detection
The system checks the DC current before the compressor starts.
Error Decision
Conditions
The voltage converted from the DC current before compressor start-up is out of the range
0.5 ~ 4.5 V.
The DC voltage before compressor start-up is below 50 V.
Supposed
Causes
Broken or disconnected harness
Defective outdoor unit PCB
Troubleshooting
NO
YES
Turn off the power. Then, turn on
the power to restart the system.
YES
NO
Replace the harness.
Replace the outdoor unit
PCB (main PCB).
Is the harness broken?
Restart operation
and error displayed
again?
Check the relay harness for the
compressor.
Not a malfunction.
Keep observing.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
86 Service Diagnosis
Reference
Reference
4.20 Position Sensor Abnormality
Error Code H6
Description Position Sensor Abnormality
Method of Error
Detection
A compressor start-up failure is detected by checking the compressor running condition through
the position detection circuit.
Error Decision
Conditions
The compressor fails to start in about 15 seconds after the compressor run command signal
is sent.
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 11 minutes without any other error
Supposed
Causes
Power supply voltage out of specification
Disconnection of the compressor harness
Defective compressor
Defective outdoor unit PCB
Start-up failure caused by the closed stop valve
Input voltage out of specified range
Troubleshooting
Check No.18 Refer to P.101
Check No.20 Refer to P.102
Voltage as rated?
OK?
Normal?
Correct the power supply.
Replace the stop valve.
Replace the outdoor
unit PCB (main PCB).
Replace the outdoor unit
PCB (main PCB) / compressor
Reconnect the electrical
components or compressor
harnesses as specified.
Electrical
components or
compressor harnesses
connected as
specified?
Check No. 18
Check the discharge pressure.
Check No. 20
Check the short circuit of the
diode bridge.
YES
YES
YES
YES
NO
Check the power supply voltage.
Check the connection.
Turn off the power.
NO
NO
NO
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 87
4.21 Thermistor or Related Abnormality (Outdoor Unit)
Error Code H9, J3, J6 and P4
Description Thermistor or Related Abnormality (Outdoor Unit)
Method of Error
Detection
This fault is identified based on the thermistor input voltage to the microcomputer.
A thermistor fault is identified based on the temperature sensed by each thermistor.
Error Decision
Conditions
The voltage between both ends of the thermistor is either 4.96 V or more, or 0.04 V or less
with the power on.
J3 error is judged if the discharge pipe temperature is lower than the heat exchanger
temperature.
Possible Root
Causes
Disconnection of the connector for the thermistor
Defective thermistor(s)
Defective outdoor heat exchanger thermistor in the case of J3 error
Defective outdoor unit PCB
Troubleshooting In case of P4 (Radiation fin thermistor)
Be sure to turn off the power switch before connecting or disconnecting connectors, or parts
may be damaged.
Replace the outdoor unit PCB (main PCB)
Troubleshooting In case of H9, J3, J6 and P4
Be sure to turn off the power switch before connecting or disconnecting connectors, or parts
may be damaged.
H9 : Outdoor temperature thermistor
Caution
Caution
Error displayed
again on remote
controller?
Indoor heat
exchanger thermistor
functioning?
Check the indoor heat exchanger
thermistor resistance value in the
heating operation.
Check the thermistor resistance value.
Normal?
No
Yes
Yes
Yes
No
Turn on the power again.
Replace the outdoor unit PCB.
Reconnect the connectors
or thermistors
No
J3 error: the discharge
pipe temperature is
lower than the heat
exchanger temperature.
Cooling : Outdoor heat
exchanger
temperature.
Heating : Indoor heat
exchanger
temperature.
Replace the defective
thermistor(s) of the following
thermistors.
• Outdoor temperature
thermistors.
• Discharge pipe thermistor.
• Outdoor heat exchanger
thermistor.
Replace the indoor heat
exchanger thermistor.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
88 Service Diagnosis
Reference
Note
Check No.01 Refer to P.96
When replacing the defective thermistor(s), replace the thermistor as ASSY.
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 89
Reference
Reference
4.22 Electrical Box Temperature Rise
Error Code L3
Method of Error
Detection
An electrical box temperature rise is detected by checking the radiation fin thermistor with the
compressor off.
Error Decision
Conditions
With the compressor off, the radiation fin temperature is above A °C (°F).
The error is cleared when the radiation fin temperature drops below B °C (°F).
To cool the electrical components, the outdoor fan starts when the radiation fin temperature
rises above C °C and stops when the radiation fin temperature drops below B °C (°F).
Supposed
Causes
Defective outdoor fan motor
Short circuit
Defective radiation fin thermistor
Disconnection of connector
Defective outdoor unit PCB
Troubleshooting
Check No.17 Refer to P.101
Check No.19 Refer to P.102
A (°C) B (°C) C (°C) A (°F) B (°F) C (°F)
09/12 93 70 78 09/12 199.4 158 172.4
18/24 122 64 113 18/24 251.6 147.2 235.4
WARNING
YES
NO
YES
NG
NO
OK
NO
YES
Turn off the power. Then, turn on
the power to restart the system.
Check the radiation fin
temperature.
Radiation fin dirty?
Check No. 19
Check the outdoor fan.
Error again or outdoor
fan activated?
Replace the outdoor unit
PCB (main PCB).
Clean up the radiation fin.
Replace the outdoor fan
motor.
Correct the connectors
and fan motor lead wire.
Replace the outdoor unit
PCB (main PCB).
Above A°C (°F)?
Check the installation
condition.
Go to Check No. 17.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
To cool the electrical components,
the outdoor fan starts when the
radiation fin temperature rises
abo C °C (°F) The outdoor fan stops
when the radiation fin temperature
drops below B °C (°F)
background
Troubleshooting DAMA-SM-23-021
90 Service Diagnosis
4.23 Radiation Fin Temperature Rise
Error Code L4
Method of Error
Detection
A radiation fin temperature rise is detected by checking the radiation fin temperature with the
compressor on.
Error Decision
Conditions
The radiation fin temperature with the compressor on is above A °C (°F).
The error is cleared when the radiation fin temperature drops below B °C (°F).
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 60 minutes without any other error
Supposed
Causes
Defective outdoor fan motor
Short circuit
Defective radiation fin thermistor
Disconnection of connector
Defective outdoor unit PCB
Silicone grease not applied properly on the radiation fin after replacing the outdoor unit PCB
Troubleshooting
Class
09/12 18/24
Maximum Limit, A (°C) 93 77
Reset Limit, B (°C) 78 38
Class
09/12 18/24
Maximum Limit, A (°F) 199.4 170.6
Reset Limit, B (°F) 172.4 100.4
Turn off the power. Then, turn on
the power to restart the system.
NO
NG
OK
NO
YES
Check the radiation fin
temperature.
NO
YES
YES
Above A °C (°F)?
Check No. 19
Check the outdoor fan.
Error displayed again?
Has the PCB been
replaced?
Check if silicone grease is
applied properly on the
radiation fin. If not, apply
the silicone grease.
Replace the outdoor unit
PCB (main PCB).
Replace the outdoor fan
motor.
Correct the connectors and
fan motor leads.
Replace the outdoor unit
PCB (main PCB).
YES
NO
Radiation fin dirty?
Clean up the radiation fin.
Check the installation
condition.
Go to Check No. 17.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 91
Reference
Reference
Reference
Refer to Silicone Grease on Power Transistor/Diode Bridge on page 108 for details.
Check No.17 Refer to P.101
Check No.19 Refer to P.102
background
Troubleshooting DAMA-SM-23-021
92 Service Diagnosis
4.24 Output Overcurrent Detection
Error Code L5
Description Output Overcurrent Detection
Method of Error
Detection
An output overcurrent is detected by checking the current that flows in the inverter DC section.
Error Decision
Conditions
A position signal error occurs while the compressor is running.
A rotation speed error occurs while the compressor is running.
An output overcurrent is fed from the output overcurrent detection circuit to the
microcomputer.
If error repeats, the system is shut down.
Reset condition: Continuous run for about 5 minutes without any other error.
Possible root
Causes
Poor installation condition
Closed stop valve
Defective power module
Wrong internal wiring
Abnormal power supply voltage
Defective outdoor unit PCB
Power supply voltage out of installation
Defective compressor
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 93
Reference
Reference
Reference
Troubleshooting
Check No.17 Refer to P.101
Check No.18 Refer to P.101
Check No.22 Refer to P.104
Error again?
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
Normal?
Check the power supply voltage.
Voltage as rated?
Stop valve fully open?
Check No. 17
Check the installation condition.
Check No. 22
Check the power module.
Turn off the power. Then, turn on
the power to restart the system.
See if the same error occurs.
Short circuit of
wire breakage between
compressor’s coil
phases?
Monitor the power supply
voltage, discharge and suction
pressures, and other factors
for a long term.
Possible causes
* Momentary drop of power
supply voltage
* Compressor overload
* Short circuit
Fully open the stop valve.
Replace the compressor.
Correct the power supply.
Check the discharge pressure.
Go to Check No. 18
Replace the outdoor unit
PCB (main PCB).
Check the connectors and
other components.
Not a malfunction.
Keep observing.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Troubleshooting DAMA-SM-23-021
94 Service Diagnosis
4.25 Four Way Valve Abnormality
Remote
Controller
Display
EA
Method of
Malfunction
Detection
The indoor air temperature thermistor, the indoor unit heat exchanger thermistor, the outdoor
temperature thermistor and the outdoor unit heat exchanger thermistor are checked to see if the
function within their normal ranges in the operating mode.
Malfunction
Decision
Conditions
A following condition continues over 10 minute after operating 5 minutes.
Cooling / dry operation
(room temp. ˗ indoor heat exchanger temp.) < -5°C (23°F).
Heating
(indoor unit heat exchanger temp. ˗ room temp.) < -5°C (23°F).
Supposed
Causes
Connector in poor contact
Thermistor defective
Outdoor unit PCB defective
Four way valve coil or harness defective
Four way valve defective
Foreign substance mixed in refrigerant
Insufficient gas
background
DAMA-SM-23-021 Troubleshooting
Service Diagnosis 95
Troubleshooting
NO
NG
NO
YES
OK
YES
NG
OK
OK
YES
NO
NO
NG
YES
Four way valve
coil disconnected
(loose)?
Harness
disconnected?
Check the continuity of the four
way valve coil and harness.
Disconnect the harness
from the connector.
Resistance
between
harnesses about
500-2300Ω
Check No. 13
Check the four way valve
switching output.
Any thermistor
disconnected?
Check No. 01
Check the thermistors.
Check No. 14
Check the refrigerant
line.
*) Refrigerant shortage
*) Water mixed
*) Stop valve
Replace the defective
thermistor(s).
Correct the four way
valve coil.
Reconnect the
harness.
Replace the four way
valve coil.
Replace the outdoor
unit PCB (main PCB).
Reconnect the
thermistor(s).
Refer to the refrigerant
line check procedure.
Replace the four way
valve (defective or
dust-clogged).
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Actuator Check DAMA-SM-23-021
96 Service Diagnosis
5. Actuator Check
5.1 Thermistor Resistance Check
Check No.01 Measure the resistance of each thermistor using multimeter.
The resistance values are defined by below table.
If the measured resistance value does not match the listed value, the thermistor must be
replaced.
Disconnect the connector of thermistor ASSY from the PCB to measure the resistance
between the pins using multimeter.
To check the thermistor soldered on a PCB, disconnect the PCB from other PCB/parts, and
measure the resistance between the both ends of soldered thermistor.
Tolerance resistance type A : ±5%
Tolerance resistance type B : ±2%
Multimeter
Resistance range
Thermistor ASSY Soldered thermistor
Multimeter
Thermistor temperature (°C) Resistance (k)
°C °F
Room temperature
thermistor
Room temperature
thermistor
-20 -4 73.4 197.8
-15 5 57.0 148.2
-10 14 44.7 112.1
-5 23 35.3 85.60
0 32 28.2 65.93
5 41 22.6 51.14
10 50 18.3 39.99
15 59 14.8 31.52
20 68 12.1 25.02
25 77 10.0 20.00
30 86 8.2 16.10
35 95 6.9 13.04
40 104 5.8 10.62
45 113 4.9 8.707
50 122 4.1 7.176
Thermistor Resistance Type R (25°C) or (77°F)
Indoor Unit
Room temperature thermistor B 10 k
Indoor heat exchanger thermistor B 10 k
Outdoor Unit
Outdoor temperature thermistor A 20 k
Outdoor heat exchanger thermistor A 20 k
Discharge pipe thermistor A 20 k
background
DAMA-SM-23-021 Actuator Check
Service Diagnosis 97
5.2 Power Supply Waveform Check
Check No.11 Measure the power supply waveform between No. 1 and No. 2 on the terminal strip, and check
the waveform disturbance.
Check if the power supply waveform is a sine wave (Fig.1).
Check if there is waveform disturbance near the zero-cross (sections circled in Fig.2).
5.3 Electronic Expansion Valve Check
Check No.12 Conduct the followings to check the electronic expansion valve (EV).
1. Check if the EV connector is correctly connected to the PCB.
2. Turn the power off and on again, and check if the EV generates a latching sound.
3. If the EV does not generate a latching sound in the step 2 above, disconnect the connector
and check the continuity using a multimeter.
4. Check the continuity between the pins 5 - 1, 5 - 2, 5 - 3, 5 - 4 (for 5P connectors) and
6 - 1, 6 - 3, 5 - 2, 5 - 4, (for 6P connectors). If there is no continuity between the pins, the EV
coil is faulty.
5. If the continuity is confirmed in step 3, the outdoor unit PCB (main PCB) is faulty.
[Fig.1] [Fig.2]
Class 09/12 18/24
Harness 5P Harness 6P
Harness 5P
5P Connector
CheckS20
5 - 1
5 - 2
5 - 3
5 - 4
1 2 3 4 5
Harness 6P
6P Connector
Check
6 - 1
6 - 3
5 - 2
5 - 4
1 2 3 4 5 6
background
Actuator Check DAMA-SM-23-021
98 Service Diagnosis
5.4 Four Way Valve Performance Check
Check No.13
NO
YES
Start heating operation
NO
Replace the four way valve.
(Fig.1)
Voltage at S80
DC 310-340V
DC 12-15V
Time
Compressor
ON
YES
* Four way valve coil Cooling / Dry /
Defrost: Not energized
Heating: energized
Turn the power off and then on
again
S80
voltage at 310 - 340
VDC with compressor
on? (Fig.1)
Disconnect the four way valve coil
from the connector and check the
continuity
Four way
valve coil resistance at
500-2300Ω
Replace the outdoor
unit PCB (main PCB).
Replace the four way valve
coil.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
DAMA-SM-23-021 Actuator Check
Service Diagnosis 99
5.5 Inverter Unit Refrigerant System Check
Check No.14
5.6 Rotation Pulse Check on the Outdoor Unit PCB
Check No.16 Applicable for Class 09 and Class 12
Make sure that voltage supply of 208V/230 VAC are supplied to the unit.
1. Set operation off and power off. Disconnect the connector S71 and power on.
2. Check that the sensor voltage between the pins 11 - 10 is 5 VDC.
3. Ensure operation off and power off. Connect the connector S71 and power on.
4. Check whether rotation pulses (0 ~ 5 VDC) are output at the pins 12-10, 13-10 when the fan
motor is rotated 1 turn by hand.
5. Ensure operation off and power off. Check the sinusoidal voltage is generated between pins
1-4 and 4-7 when the fan motor is manually rotated once.
When the fuse is melted, check the outdoor fan motor for proper function.
If NG in step 2 Defective PCB Replace the outdoor unit PCB (main PCB).
If NG in step 4 Defective Hall IC Replace the outdoor fan motor.
If NG in step 5 Defective Fan Motor Replace the outdoor fan motor.
If OK in all steps Replace the outdoor unit PCB (main PCB).
Refrigerant system check
Is the discharge pipe
thermistor disconnected from
the holder?
Check for refrigerant leakage.
See the section on refrigerant
shortage detection.
YES
NO
Reconnect the thermistor.
Replace the refrigerant.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
PCB
Phase U
Phase V
Phase W
SGND
Rotation Pulse 1
Rotation Pulse Voltage (5 VDC)
Rotation Pulse 2
S71
1
4
7
10
11
12
13
background
Actuator Check DAMA-SM-23-021
100 Service Diagnosis
Applicable for Class 18 and Class 24
Make sure that voltage supply of 208V/230 VAC are supplied to the unit.
1. Ensure operation off and power off. Check the sinusoidal voltage is generated between pins
1-3 and 3-5 when the fan motor is manually rotated once.
When the fuse is melted, check the outdoor fan motor for proper function.
If NG in step 1 Defective Fan Motor Replace the outdoor fan motor.
If OK in step 1 Replace the outdoor unit PCB (main PCB).
PCB
Phase U
Phase V
Phase W
S70
1
3
5
background
DAMA-SM-23-021 Actuator Check
Service Diagnosis 101
5.7 Installation Condition Check
Check No.17
5.8 Discharge Pressure Check
Check No.18
Installation condition check
OK
NG
YES
YES
NO
NO
NO
YES
Check the allowable
dimensions of the air
suction and
discharge area.
Is the discharged air
short-circuited?
Is the outdoor heat
exchanger very dirty?
Is the airflow blocked by
obstacles or winds
blowing in the opposite
direction?
Change the installation
location or direction.
Change the installation
location or direction.
Clean the outdoor heat
exchanger.
Check the outdoor temperature.
(The outdoor temperature
should be within the operation
range.)
Change the installation
location or direction.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
YES
YES
YES
NO
NO
NO
Is the stop valve open?
Open the stop valve.
Replace the compressor.
Discharge pressure check
Is the air filter or
indoor/outdoor heat
exchanger dirty?
Is the connection pipe
deformed?
Replace the pipe installed at
the site.
Clean the dirty air filter or
indoor/outdoor heat
exchanger.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
background
Actuator Check DAMA-SM-23-021
102 Service Diagnosis
5.9 Outdoor Fan System Check
Check No.19 DC motor
5.10 Main Circuit Short Check
Check No.20 Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is
approximately 0 V before checking.
Measure the resistance between the pins of the DB1 referring to the table below.
If the resistance is or less than 1 k, short circuit occurs on the main circuit.
Diagram Main Circuit Short Check for Class 09 and Class 12
YES
NO
NO
YES
Outdoor fan system is functioning.
Check the outdoor fan system.
Reconnect the connector.
Is the
outdoor fan running?
Fan motor
lead wire connector
disconnected?
Go to Check No. 16.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
Positive terminal (+) of
digital multimeter
~ (2, 3) + (4) ~ (2, 3) – (1)
Negative terminal (–) of
digital multimeter
+ (4) ~ (2, 3) – (1) ~ (2, 3)
Resistance is OK. several k ~ several M
Resistance is NG. 0 or
background
DAMA-SM-23-021 Actuator Check
Service Diagnosis 103
Diagram Main Circuit Short Check for Class 18 and Class 24
background
Actuator Check DAMA-SM-23-021
104 Service Diagnosis
5.11 Power Module Check
Check No.22 Check to make sure that the voltage between (+) and (–) of the power module is approximately
0 V before checking.
Disconnect the compressor harness connector from the outdoor unit PCB. To disengage the
connector, press the protrusion on the connector.
Follow the procedure below to measure resistance between the (+) or (–) terminal of the
power module and the U, V, or W terminal of the compressor with a multimeter. Evaluate the
measurement results referring to the following table.
Diagram Power Module Check for Class 09 and Class 12
Diagram Power Module Check for Class 18 and Class 24
Positive terminal (+) of
digital multimeter
Power module
(+)
UVW
Power module
(–)
UVW
Negative terminal (–) of
digital multimeter
UVW
Power module
(+)
UVW
Power module
(–)
Resistance is OK. several k ~ several M
Resistance is NG. 0 or
Pin 24: +
Pin 23: U
Pin 22: V
Pin 21: W
Pin 20: -
background
DAMA-SM-23-021
Part 6 Trial Operation and Field Settings 105
1. Pump Down Operation........................................................................106
2. Forced Cooling Operation ...................................................................107
3. Silicone Grease on Power Transistor/Diode Bridge............................108
Part 6
Trial Operation and
Field Settings
background
Pump Down Operation DAMA-SM-23-021
106 Trial Operation and Field Settings
Reference
1. Pump Down Operation
Outline In order to protect the environment, be sure to conduct pump down operation when relocating or
disposing of the unit.
Details 1. Remove the valve caps from the liquid stop valve and the gas stop valve.
2. Carry out forced cooling operation.
3. After 5 to 10 minutes, close the liquid stop valve with a hexagonal wrench.
4. After 2 to 3 minutes, close the gas stop valve and stop the forced cooling operation.
Refer to page 107 for forced cooling operation.
Gas stop valve
Valve cap
Close
Liquid stop valve
Service port
Hexagonal
wrench
background
DAMA-SM-23-021 Forced Cooling Operation
Trial Operation and Field Settings 107
2. Forced Cooling Operation
Outline The forced cooling operation is allowed when both the following conditions are met.
1. The outdoor unit is not abnormal and not in the 3-minute standby mode.
2. The outdoor unit is not operating.
Protection functions have priority over all other functions during forced cooling operation.
Details With indoor unit ON/OFF switch
Press indoor unit ON/OFF switch (SW1) for at least 5 seconds. The operation will start.
Forced cooling operation will stop automatically after about 15 minutes.
To stop the operation, press indoor unit ON/OFF switch.
ON/OFF
switch
background
Silicone Grease on Power Transistor/Diode Bridge DAMA-SM-23-021
108 Trial Operation and Field Settings
3. Silicone Grease on Power Transistor/Diode
Bridge
Outline Apply the specified silicone grease to the heat radiation part of a power transistor/diode bridge
when you replace an outdoor unit PCB. The silicone grease encourages the heat radiation of a
power transistor/diode bridge.
Details 1. Wipe off the old silicone grease completely.
2. Apply the silicone grease evenly. See the illustrations below for examples of application.
3. Tighten the screws of the power transistor/diode bridge.
4. Make sure that the heat radiation parts are firmly contacted to the radiation fin.
Note: Smoke emission may be caused by bad heat radiation when the silicone grease is not
appropriately applied.
OK: Evenly applied
NG: Not evenly applied
NG: Foreign matter is stuck.
Power transistor
(or diode bridge)
Silicone grease
Radiation
fin
PCB
Foreign matter
background
DAMA-SM-23-021
Part 7 Appendix 109
1. Piping Diagrams..................................................................................110
1.1 Indoor Unit............................................................................................110
1.2 Outdoor Unit .........................................................................................112
2. Wiring Diagrams..................................................................................114
2.1 Indoor Unit............................................................................................114
2.2 Outdoor Unit .........................................................................................115
2.3 Printed Circuit Board Connector Wiring Diagram.................................116
2.4 Printed Circuit Board Connector Wiring Diagram.................................117
3. Operation Limit....................................................................................119
Part 7
Appendix
background
Piping Diagrams DAMA-SM-23-021
110 Appendix
1. Piping Diagrams
1.1 Indoor Unit
Model: FTKF09A, FTXF09A
Model: FTKF12A, FTXF12A
3D148808
Note: Dimension in inch
3D143684A
Note: Dimension in inch
background
DAMA-SM-23-021 Piping Diagrams
Appendix 111
Model: FTKF18A, FTXF18A
Model: FTKF24A, FTXF24A
3D128349B
Note: Dimension in inch
3D128352B
Note: Dimension in inch
background
Piping Diagrams DAMA-SM-23-021
112 Appendix
1.2 Outdoor Unit
Cooling Only
Model: RKF09/12A, RXF09/12A
3D148805
Note: Dimension in inch
background
DAMA-SM-23-021 Piping Diagrams
Appendix 113
Model: RKF18A, RXF18A
Model: RKF24A, RXF24A
3D148747
Note: Dimension in inch
3D148745
Note: Dimension in inch
background
Wiring Diagrams DAMA-SM-23-021
114 Appendix
2. Wiring Diagrams
2.1 Indoor Unit
Model: FTKF-A, FTXF-A
3P599152E
background
DAMA-SM-23-021 Wiring Diagrams
Appendix 115
2.2 Outdoor Unit
Model: RKF09/12A, RXF09/12A
Model: RKF18/24A, RXF18/24A
3P685297C
3P685295C
background
Wiring Diagrams DAMA-SM-23-021
116 Appendix
2.3 Printed Circuit Board Connector Wiring Diagram
Control PCB
(A1P)
Display/Signal
Receiver PCB
(A2P)
1) CN_SW_UD Connector for swing motor (horizontal blade)
2) CN_DSP Connector for display/signal receiver PCB (A2P)
3) CN_COIL Connector for indoor heat exchange thermistor (R2T)
4) CN_DCFN Connector for DC fan motor
5 LIVE, NEUTRAL, SIG Connector for terminal strip
6) EARTH Connector for terminal strip (frame ground)
7) F101, F111 Fuse (3.15 A, 250 V)
8) V101 Varistor
1) CN_DSP1 Connector for control PCB (A1P)
2) SW201
Indoor unit ON/OFF switch
(Forced cooling operation ON/OFF switch)
* Refer to page 107 for detail of forced cooling operating.
3) COOL/HEAT LED LED for operating
4) TIMER LED LED for timer (yellow)
5 RTH201 Room temperature thermistor
background
DAMA-SM-23-021 Wiring Diagrams
Appendix 117
2.4 Printed Circuit Board Connector Wiring Diagram
2.4.1 09/12 Class
Main PCB (A1P)
1) S20 Connector for electronic expansion valve coil
2) S40 Connector for overload protector
3) S71 Connector for DC fan motor
4) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger,
discharge pipe temperature)
5) HL1, HN1, S Connector for terminal strip
6) E1, E2 Terminals for earth wire
7) S30 Connector for compressor
8) FU2 Fuse (3.15 A, 250 V)
9) FU3 Fuse (20 A, 250 V)
10) LED A LED for service monitor (green)
11) V2, V3 Varistor
background
Wiring Diagrams DAMA-SM-23-021
118 Appendix
2.4.2 18/24 Class
Main PCB (A1P)
1) S20 Connector for electronic expansion valve coil
2) S40 Connector for overload protector
3) S70 Connector for DC fan motor
4) S90 Connector for thermistors (outdoor temperature,
outdoor heat exchanger, discharge pipe
temperature)
5) S80 Connector for four way valve coil
6) HL1, HN1, S Connector for terminal strip
7) E1, E2 Terminals for earth wire
8) U, V, W Connector for compressor
9) FU1, FU2 Fuse (3.15 A, 250 V)
10) FU3 Fuse (30 A, 250 V)
11) LED A LED for service monitor (green)
12) V1, V2, V3 Varistor
background
DAMA-SM-23-021 Operation Limit
Appendix 119
3. Operation Limit
Cooling Only
Model: RKF09/12A
Model: RKF18/24A
3P601788-4K
3P601788-4K
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
104
86
68
50
32
14
50 57.2 68 73.4 82.4 86
118.4
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
104
86
68
50
32
14
50 57.2 68 73.4 82.4 86
122
background
Operation Limit DAMA-SM-23-021
120 Appendix
Heatpump
Model: RXF09/12A
Model: RXF18/24A
3P601788-4K
3P601788-4K
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
118.4
104
86
68
50
32
14
50 57.2 68 73.4 82.4 86
70
64.4
60
50
41
32
23
14
5
50 68 86
The use of your air conditioner
outside the range of working
temperature and humidity can
result in serious failure.
122
104
86
68
50
32
14
50 57.2 68 73.4 82.4 86
70
64.4
60
50
41
32
23
14
5
50 68 86
background
Warning
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
©
All rights reserved
Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorized importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any inquiries, please contact your local importer, distributor and/or retailer.
Lot 60334, Persiaran Bukit Rahman Putra 3,
Taman Perindustrian Bukit Rahman Putra,
47000 Sungai Buloh, Selangor Darul Ehsan,
Malaysia.
http://www.daikin.com/products/ac/
Specifi cations, designs and other content appearing in this brochure are current as of January 2019 but subject to change without notice.
DAMA-SM-23-021
12/2023 AK.B
CVR DAMA-SM-23-021 FTKF-A and FTXF-A Series.indd 2CVR DAMA-SM-23-021 FTKF-A and FTXF-A Series.indd 2 27/2/2024 4:39:29 PM27/2/2024 4:39:29 PM

Specifications

Daikin RKF18AXVJU/FTKF18AXVJU Questions and Answers

Questions and Answers

Related Products