Mrcool MRDHP15WD-LCW TravelCool 15,000 BTU RV Air Conditioner & Heat Pump, Ductless Kit, White

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction User Manual
  • Wired Controller Manual - (English) Download
Other Documents
MRDHP15WD-LCW photo

Installation Guide

This is the main product document for model MRDHP15WD-LCW.

The file format is pdf, 28 pages, you can download this manual here .

background
MRCOOL
®
TRAVELCOOL™
INSTALLATION & OWNER’S MANUAL
MODELS:
Read this manual carefully before installation and keep it where
the operator can easily nd it for future reference.
Due to updates and constantly improving performance, the
information and instructions within this manual are subject to
change without notice.
Version Date: June 16, 2026
Please visit www.mrcool.com/documentation
to ensure you have the latest version of this manual.
This product utilizes R-32 refrigerant
MRDHP15*-D
background
mrcool.com1
CONTENTS
SAFETY ............................................................................................................................. 1
UNIT OVERVIEW........................................................................................................... 8
2.1 Parameter List ..................................................................................................... 8
2.2 Parts Diagram ..................................................................................................... 9
2.3 Product Map ....................................................................................................... 11
INSTALLATION ........................................................................................................... 11
3.1 Product Application ........................................................................................... 11
3.2 Installation Location ......................................................................................... 11
3.3 Electrical Specications .................................................................................... 12
3.4 Installation Methods ......................................................................................... 12
3.5 Installation Application ..................................................................................... 14
3.6 Communication Cable ...................................................................................... 16
3.7 Adjustment of Airow Deector ...................................................................... 17
POST-INSTALLATION ............................................................................................... 19
4.1 Electrical Connection ........................................................................................ 19
4.2 Control Panel ..................................................................................................... 21
4.3 Remote Controller ............................................................................................. 21
4.4 App Operation ................................................................................................... 23
4.5 Maintenance ...................................................................................................... 24
4.6 Wiring Diagram .................................................................................................. 25
TROUBLESHOOTING................................................................................................ 26
1
Contents
Incorrect usage may cause serious damage or injury.
The symbols below are used throughout this manual to indicate instructions that should be
followed closely or actions that should be avoided to prevent death, injury, and/or property
damage.
Safety Precautions
Read Before Using
CAUTION
Indicates the possibility of personal injury or loss of life.
Indicates the possibility of property damage or serious
consequences.
WARNING
2
3
4
5
background
mrcool.com 2 2
WARNING FOR PRODUCT INSTALLATION
• To reduce the risk of injury, users must read the installation manual carefully.
• Installation of this device must comply with local and national regulations, and the unit should only be
operated in well-ventilated areas. Please read this manual before installing and using the equipment.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory, or
mental capabilities, or those lacking experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
• Children should not play with or use this appliance. Keep the appliance and its cord out of reach of
children.
• This appliance is intended to be used in applications, such as campers, RVs, trailers or trucks.
• Properly store the product and check whether it is abnormal before use. If it is abnormal, discontinue use.
• Please use the product according to its intended use, there is a risk of injury if misused.
• Use only an external supply with the following specications: <AC110V 60HZ, 10.7A~13.8A>.
• This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least resistance for the electric current.
• Do not damage the refrigerant circuit.
• In the appliance's enclosure or infrastructure, keep ventilation openings clear of obstructions.
• To avoid a hazard due to instability of the appliance, it must be xed in accordance with the instructions.
NOTE
1. Please comply with the relevant safety instructions and regulations of the vehicle manufacturer and the
repair workshop.
MRCOOL® will not be held liable for any damages caused by the following:
• Incorrect installation or connection.
• Damage to the product due to mechanical impact or incorrect connection voltage.
• Unauthorized modication of the product without explicit permission from MRCOOL®.
• Use of the product for purposes other than those described in this manual.
SAFETY
1
WARNING
• Do not use means to accelerate the defrosting process or to clean the unit, other than those recommended
by MRCOOL®.
• The unit should be stored in a room without continuously-operating ignition sources, such as open flames,
an operating gas appliance, or an electric heater that is in use.
• Do not pierce or burn.
• Be aware that refrigerants may not be odorous.
• The unit should be stored in a well-ventilated area where the room size corresponds to the room area, as
specified for operation, and where mechanical damage can be prevented from occurring.
• The compliance with national gas regulations should be observed and the minimum applicable area for
this unit is 49.21ft (15m).
• Please ensure there are no obstacles in front of the machine and keep ventilation openings clear of
obstruction. Servicing should be performed only as recommended by MRCOOL®.
• Any person who is involved with servicing or maintaining into a refrigerant circuit should hold a current
valid certificate from a industry-accredited assessment authority, which authorizes their competence to
handle refrigerants safely.
• Servicing should only be performed as recommended by MRCOOL®. Maintenance and repair require the
assistance of other skilled personnel should be carried out under the supervision of the professional who
is licensed in the use of flammable refrigerants.
background
mrcool.com3
SAFETY
1
WARNING
• Electrical connections must only be performed by qualied professionals.
• The rooftop air conditioner must be installed, relocated, and serviced by professionals in accordance with
local and national wiring regulations and the instructions provided in this manual.
• Secure cables properly to prevent damage.
CAUTION
• Use conduits to protect cables from being cut or damaged by sharp edges.
• Do not place loose or coiled cables near conductive materials (such as metal).
• Do not pull or strain the cables.
CAUTION
• This device may only be used for its designated purpose.
• The rooftop air conditioner must not be used on agricultural or construction vehicles.
• Do not make any modications to the device.
• Do not use automatic car washes when a rooftop air conditioner is installed on the vehicle.
• If a fault occurs in the refrigerant circuit of the rooftop air conditioner, it must be inspected and properly
repaired by a professional company. Refrigerant must never be released into the atmosphere.
WARNING
• The rooftop air conditioner must be securely and reliably installed to prevent falling.
• Operation of the rooftop air conditioner is only permitted when the housing and wiring are intact and
undamaged. Do not use the appliance near ammable liquids or in enclosed rooms.
• Ensure that no ammable materials are placed or installed near the air outlet. The appliance must be kept
at least 19.68in (49.98cm) away from ammable materials. Do not insert hands or objects into the air inlet,
outlet, or the interior of the air conditioner.
NOTE
If the supply cord is damaged, it must be replaced by MRCOOL®, a service agent, or licensed contractor to
avoid hazard.
WARNING
• The installation, maintenance, and repair of rooftop air conditioners must only be performed by
professionals according to national and local wiring regulations and instructions provided in this manual.
• Improper repairs may lead to severe damage to the air conditioner or pose a risk of personal injury or
death.
• In case of re, do not remove the upper cover of the rooftop air conditioner. Use approved re
extinguishing agents to ght the re. Never use water for extinguishing.
NOTE
Consult your vehicle manufacturer to determine whether a technical inspection of the vehicle is required after
installing the rooftop air conditioner, as well as whether the vehicle’s documented height needs to be updated:
MRCOOL® TravelCool ™: Height increased by 10.62in (26.97cm).
background
mrcool.com 4
4
CAUTION
• This unit should only be used for its designated purpose.
• The rooftop air conditioner must not be used for agricultural and construction vehicles.
• Do not make any modications to the device.
• Do not use automatic car washes when a rooftop unit is installed on the vehicle.
• If a fault occurs in the refrigerant circuit of the rooftop unit, it must be inspected and properly repaired by
a professional. Refrigerant should not be released into the atmosphere.
NOTE
If the supply cord is damaged, it must be replaced by MRCOOL®, a service agent, or licensed contractor to
avoid hazard.
WARNING
1. Work Procedure
• Work shall be undertaken under a controlled procedure so as to minimize the risk of a ammable gas or
vapor being present while the work is being performed.
2. General Work Area
• All maintenance sta and others working in the local area shall be instructed on the nature of work being
carried out. Work in conned spaces shall be avoided. The area around the workspace shall be sectioned
o. Ensure that the conditions within the area have been made safe by control of ammable material.
3. Checking for the Presence of Refrigerant
• The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially ammable atmospheres. Ensure that the leak detection equipment being
used is suitable for use with ammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.
4. Presence of a Fire Extinguisher
• If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re
extinguishing equipment shall be available to hand. Have a dry powder or CO2 re extinguisher adjacent to
the charging area.
5. No Ignition Sources
• No person carrying out work in relation to a refrigeration system which involves exposing any pipe work
that contains or has contained ammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of re or explosion. All possible ignition sources, including cigarette smoking,
should be kept suciently far away from the site of installation, repairing, removing and disposal, during
which ammable refrigerant can possibly be released to the surrounding space. Prior to work taking place,
the area around the equipment is to be surveyed to make sure that there are no ammable hazards or
ignition risks. "No Smoking" signs should be displayed.
6. Ventilated Area
• Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or
conducting any hot work. A degree of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into
the atmosphere.
7. Checks to the Refrigeration Equipment
• Where electrical components are being changed, they shall be t for the purpose and to the correct
specication. At all times the manufacturer' s maintenance and service guidelines shall be followed. If
in doubt consult the manufacturer's technical department for assistance. The following checks shall be
applied to installations using ammable refrigerants:
• the charge size is in accordance with the room size within which the refrigerant containing parts are
installed;
• the ventilation machinery and outlets are operating adequately and are not obstructed;
• if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence
of refrigerant;
SAFETY
1
background
mrcool.com5
SAFETY
1
WARNING
• marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall
be corrected;
• refrigeration pipe or components are installed in a position where they are unlikely to be exposed to
any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitably protected
against being so corroded.
8. Checks to Electrical Devices
• Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately
but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be
reported to the owner of the equipment so all parties are advised. Initial safety checks shall include: that
capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking; that no live
electrical components and wiring are exposed while charging, recovering or purging the system; that there
is continuity of earth bonding.
9. Sealed Electrical Components Should be Replaced
10. Intrinsically Safe Components Must be Replaced
11. Cabling
• Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or
any other adverse environmental eects. The check shall also take into account the eects of aging or
continual vibration from sources such as compressors or fans.
12. Detection of Flammable Refrigerants
• Under no circumstances shall potential sources of ignition be used in the searching for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked ame) shall not be used.
13. Leak Detection Methods
• The following leak detection methods are deemed acceptable for systems containing ammable
refrigerants. Electronic leak detectors shall be used to detect ammable refrigerants, but the sensitivity
may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-
free area.) Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant
used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall
be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is
conrmed.
• Leak detection uids are suitable for use with most refrigerants but the use of detergents containing
chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work.
If a leak is suspected, all naked ames shall be removed/ extinguished. If a leakage of refrigerant is found
which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means
of shut o valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be
purged through the system both before and during the brazing process.
14. Removal and Evacuation
• When breaking into the refrigerant circuit to make repairs or for any other purpose conventional
procedures shall be used. However, for ammable refrigerants it is important that best practice be
followed, since ammability is a consideration. The following procedure shall be adhered to:
• safely remove refrigerant following local and national regulations;
• evacuate;
• purge the circuit with inert gas (optional for A2L);
• evacuate (optional for A2L);
• continuously ush or purge with inert gas when using ame to open circuit; and;
• open the circuit.
• The refrigerant charge should be recovered into the correct recovery cylinders if venting is not allowed by
local and national codes. For appliances containing ammable refrigerants, the system shall be purged
with oxygen-free nitrogen to render the appliance safe for ammable refrigerants. This process might need
to be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.
background
mrcool.com 6
6
WARNING
• For appliances containing ammable refrigerants, refrigerant purging shall be achieved by breaking
the vacuum in the system with oxygen-free nitrogen and continuing to ll until the working pressure is
achieved, then venting to the atmosphere, and nally pulling down to a vacuum (optional for A2L). This
process shall be repeated until no refrigerant is within the system (optional for A2L).
• When the nal oxygen-free nitrogen charge is used, the system shall be vented down to atmospheric
pressure to enable work to take place.
• The outlet for the vacuum pump shall not be close to any potential ignition sources, and ventilation should
be available.
15. Charging Procedures
• In addition to conventional charging procedures, the following requirements should be followed:
• Ensure that contamination of dierent refrigerants does not occur when using charging equipment.
• Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
• Cylinders shall be kept upright.
• Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
• Label the system when charging is complete (if not already).
• Extreme care shall be taken not to overll the refrigeration system. Prior to recharging the system,
it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on
completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to
leaving the site.
16. Decommissioning
• Before carrying out this procedure, it is essential that the technician is completely familiar with the
equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required
prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is
commenced.
a. Become familiar with the equipment and its operation.
b. Isolate system electrically.
c. Before attempting the procedure ensure that: mechanical handling equipment is available, if required, for
handling refrigerant cylinders; all personal protective equipment is available and being used correctly; the
recovery process is supervised at all times by a competent person and recovery equipment and cylinders
conform to the appropriate standards.
d. Pump down the refrigerant system, if possible.
e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the
system.
f. Make sure that cylinder is situated on the scales before recovery takes place.
g. Start the recovery machine and operate in with manufacturer's instructions.
h. Do not overll cylinders. (No more than 80 % volume liquid charge).
i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
j. When the cylinders have been lled correctly and the process completed, make sure that the cylinders and
the equipment are removed from site promptly and all isolation valves on the equipment are closed o.
k. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned
and checked.
17. Labeling
• Equipment shall be labeled stating that it has been de- commissioned and emptied of refrigerant. The label
shall be dated and signed. For appliances containing FLAMMABLE REFRIGERANTS, ensure that there are
labels on the equipment stating the equipment contains FLAMMABLE REFRIGERANT.
18. Recovery
• When removing refrigerant from a system, either for servicing or decommissioning, it is recommended
good practice that all refrigerants are removed safely.
SAFETY
1
background
mrcool.com7
SAFETY
1
Symbols Displayed on Indoor & Outdoor Unit
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant
is leaked and exposed to an external ignition source, there is a risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with
reference to the installation manual.
CAUTION
CAUTION
This symbol shows that information is available such as the operating manual or
installation manual.
WARNING
• When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are
employed. Ensure that the correct number of cylinders for holding the total system charge are available.
All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e.
special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and
associated shut-o valves in good working order. Empty recovery cylinders are evacuated and, if possible,
cooled before recovery occurs.
• The recovery equipment shall be in good working order with a set of instructions concerning the
equipment that is at hand and shall be suitable for the recovery of the ammable refrigerant. If in doubt,
consult MRCOOL®. In addition, a set of calibrated weighing scales shall be available and in good working
order. Hoses should be nished with leak-free disconnect couplings and should be in good condition.
• The recovered refrigerant shall be processed according to local codes in the correct recovery cylinder, and
the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in
cylinders. If compressors or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that ammable refrigerant does not remain within the lubricant. The
compressor body shall not be heated by an open ame or other ignition sources to accelerate this process.
• When oil is drained from a system, it shall be carried out safely.
19. Transportation, Marking, and Storage for Units that Use Flammable Refrigerants
• Transportation of equipment containing ammable refrigerants
• Compliance with the transportation regulations
• Marking equipment using signs
• Compliance with local regulations
• Disposal of equipment that uses ammable refrigerants
• Compliance with national regulations
• Storage of equipment and appliances
• The storage of the unit should be in accordance with the applicable regulations or instructions,
whichever is more stringent
• Storage of packaged equipment
• The unit should be packaged in such a way that if packaging is damaged, it will still protect the unit and
keep it from leaking refrigerant
• The maximum number of equipment pieces allowed to be stored together will be determined by local
regulations
background
mrcool.com 8
8
UNIT OVERVIEW
2
2.1 Operating Parameters
Voltage AC120V 60HZ
Cooling Capacity 10000-15000 BTU/h
Cooling Power Consumption 1000-1650W
Heating Capacity 12000-16000 BTU/h
Heating Power
Consumption
1000-1400W
Air Volume (High Speed)
(cfm)
323.72 cfm
Maximum Design Pressure
(PSIG)
550
Minimum Design Pressure
(PSIG)
290
Refrigerant Usage R-32 (oz) 25.39 oz
Adapt to Ceiling Opening
Size (in)
14.17*14.17
background
mrcool.com9
UNIT OVERVIEW
2
Serial Number (Figure) Quantity Description
1 1 Air Conditioning Unit
2 1 ADB Panel
3 1 ADB Central Panel
4 5 Air Duct
5 1 Remote Controller (with battery)
6 4 Long Fixing Bolt
7 1 User Manual
2.2 Parts Diagram
Connecting the Rooftop Air Conditioner: Ductless ADB
background
mrcool.com 10
10
Connecting the Rooftop Air Conditioner: Ducted ADB
Serial Number (Figure) Quantity Description
1 1 Air Conditioning Unit
2 1 Control Mounting Plate
3 1 ADB Control Panel Component
4 1 Wind-Isolating Adjustable Bae
5 2 Mounting Buckle
6 1 Unlined Aluminum Foil
7 1 Remote Controller (with battery)
8 4 Long Fixing Bolt
9 1 User Manual
10 12 Round Head Self-Tapping Screw
Installation Accessories:
Optional installation accessories must be purchased separately (not included in the standard supply scope).
Ducted Section:
For thickened roofs, this duct accessory must be selected as an additional option.
UNIT OVERVIEW
2
background
mrcool.com11
INSTALLATION
3
3.1 Product Application
This MRCOOL® TravelCool ™ Unit is designed for installation on the roof of caravans or motor homes to
regulate interior temperature and humidity. It is suitable for installation on vehicles with a roof thickness of
5in (12.7cm). The unit must be mounted within a maximum inclination of ±10° from the horizontal plate and
is not approved for use in residential houses or apartments. This roof-mounted air conditioner is not suitable
for installation in construction machinery, agricultural equipment, or similar applications. Performance may be
impaired if the unit is subjected to significant vibration or shock.
3.2 Installation Location
Before installing the rooftop air conditioning unit, verify that its placement will not cause damage to any vehicle
components (e.g., lights, storage compartments, doors).
Prior to installation, consult the vehicle manufacturer to confirm whether the vehicle structure is designed to
support the static weight and load of the unit during travel. Under no circumstances should MRCOOL® be held
liable for any related issues. The vehicle manufacturer may have designated pre-approved mounting points for
the rooftop unit to ensure the installation opening can be made without the risk of compromising the vehicle
structure or cutting through any cables. Select a flat and sufficiently level area for installation at the center of the
roof between the two longitudinal sections. The inclination of the mounting surface must not exceed 10°.
Ensure no flammable objects are stored or installed near the air outlet. The unit must be kept at least 19.68in
(49.98cm) away from combustible materials. Make sure that neither the air outlet nor the air inlet is obstructed.
For safety reasons, during the installation of the rooftop air conditioner (e.g., when drilling or fastening), pay
attention to the position of existing wiring harnesses, cables, and other components within the installation area,
especially those that are not visible.
2.3 Product Map
Forming Shell
Condenser Shell
Compressor
Condenser
Condenser Motor
Condenser Wheel
Control Box
Basement
Evaporator Shell
Evaporator
Evaporator Wheel
Evaporator Motor
Ambient Temperature Range for Unit Operation
Cooling Operation
Outdoor Temperature: 63°F-109°F (17°C-43°C)
Indoor Temperature: 63°F-90°F (17°C-32°C)
Heating Operation
Outdoor Temperature: 41°F-75°F (5°C-24°C)
Indoor Temperature: 41°F-81°F (5°C-27°C)
background
mrcool.com 12
12
INSTALLATION
3
3.3 Electrical Specications
• The equipment shall be installed in accordance with local and national wiring regulations.
• Only qualified personnel may connect the rooftop air conditioning unit to the power supply.
• Verify that the voltage rating on the nameplate matches the power supply specifications.
• Do not route loose or coiled cables adjacent to conductive materials (e.g., metal).
• A circuit breaker must be incorporated into the fixed wiring. This breaker must provide all-pole
disconnection, with contact separation of at least 0.11in (0.27cm).
• The power supply must operate at the rated voltage and be dedicated to the air conditioner circuit. The
circuit supplying the air conditioner should be equipped with a leakage current-protection device and an air
circuit breaker of adequate capacity. The air circuit breaker should provide both magnetic (short-circuit) and
thermal (overload) protection. The recommended rating for the air circuit breaker is 16A.
• The fuse type and rating should correspond to the markings printed on the relevant controller or fuse
holder.
• The external static pressure of the unit at the test point is 0 MPa.
• This rooftop air conditioner is supplied with a Y-type power connection. If the power cord is damaged,
it must be replaced by MRCOOL®, an authorized service agent, or similarly qualified personnel to avoid
hazards. The air conditioner is a Class I appliance. Reliable grounding must be implemented. Ensure the
grounding conductor of the air conditioner is securely connected to the vehicle's grounding system.
3.4 Installation Methods
Create a New Opening
• When creating a new opening, it must be reinforced with suitable support frames.
Refer to the diagram and drill the corner holes (A).
Carefully cut the opening on the roof using a keyhole saw or similar tool (B).
Ensure that no electrical wiring is damaged during the process.
9.46in
(240.28mm)
background
mrcool.com13
INSTALLATION
3
Use an Existing Opening
• In this case, you can utilize a roof hatch or the space left after removing a preexisting air conditioner.
3. Use a scraper or similar tool to remove the sealant around the opening.
4. Seal screw holes and grooves with exible non-hardening butyl sealant compound.
ELECTRICAL WARNING
Ensure the power supply is disconnected before performing any operations.
The rooftop air conditioner must be connected to a circuit capable of supplying sucient current. Refer to the
product's technical specications for details.
Select the cable cross-section according to the cable length:
• Length < 24.6ft: 1.5mm
• Length ≥ 24.6ft: 2.5mm
1. Remove all screws and fasteners securing the existing roof hatch or air conditioning unit.
2. Remove the roof hatch or air conditioning unit.
background
mrcool.com 14
14
5. Provide a dedicated cable entry opening on one side of the structure, and route the power supply cable
through it into the vehicle interior.
3.5 Installation Application
CAUTION
Check the structural strength of the roof. The roof must be capable of bearing the weight of the rooftop air
conditioning unit. Even over an extended period of time, the roof must not sag or bow under the weight of the
device.
1. Lift the rooftop air conditioning unit onto the roof.
2. Place the unit on the roof panel and align it with the mounting base's grooves.
3. Observe the operation orientation.
Rooftop Air Conditioner-- Ductless ADB:
INSTALLATION
3
background
mrcool.com15
INSTALLATION
3
4. Connect the rooftop air conditioner to the power supply by attaching the cable to the cable connector.
5. Gently pull out the lter screen to create a passage for the communication cable.
6. Route the communication cable through the passage and insert the wire into the opening.
Stack the duct sections and position them according to roof thickness: The duct height should correspond to the
roof height, refer to the following table as a guide.
Roof Thickness in (cm) Recommended Duct Height in (cm)
0.98~1.1in (2.48~2.79cm) 0.03in (0.07cm)
1.1~ 1.49in (2.79~3.78cm) 0.07in (0.17cm)
1.49~1.8in (3.78~4.57cm) 0.11in (0.27cm)
1.8~2.28in (4.57~5.79cm) 0.15in (0.38cm)
2.28~2.67in (5.79~6.78cm) 0.19in (0.48m)
background
mrcool.com 16
16
INSTALLATION
3
Secure the ADB to the roof through the rooftop air conditioner using the four supplied bolts.
Using a torque wrench, tighten the screws to a torque range of 1.8 ft-lbs ± 0.22 ft-lbs. Take care not to over-
tighten.
1. Connect the 4-pin communication plug to the socket on the side of the display (2) in the ADB panel.
2. Ensure the cable is routed through the small opening away from the lter area.
3. Secure any excess cable to the bracket.
4. Press the lter screen fully into place.
5. Place the central panel cover over the ADB and connect the power supply to test the unit.
6. Connect the power supply and proceed with testing.
3.6 Communication Cable
background
mrcool.com17
INSTALLATION
3
3.7 Adjustment of Airow Deector
The air outlet direction can be adjusted by setting the airow deector.
Simply rotate the airow deector to the desired direction. The airow can be adjusted toward the ceiling or
downward toward the oor.
Connecting the Rooftop Air Conditioner-- Ducted ADB:
1. Wind-Isolating Adjustable Bae
2. Long Fixing Bolt*4
3. Control Mounting Plate
4. ADB Control Panel Component
background
mrcool.com 18
18
Installation of the Wind-Isolating Adjustable Baffle
A. Measure the thickness from the RV ceiling to the bottom of the air conditioner.
• If the distance is between 2.5-4.25in (6.35-10.795cm), a section of the air duct divider must be removed.
• If the distance is between 4.25-6 in (10.795-15.24cm), no removal is necessary.
B. Remove the backing paper from the double-sided adhesive tape on the panel mounting plate.
NOTE: Visual appearance is subject to variation.
① Represents the thickness from the RV ceiling to the bottom of the air conditioning unit.
INSTALLATION
3
background
mrcool.com19
POST-INSTALLATION
4
C. Install the air duct divider onto the ceiling template correctly according to the measured
ceiling-to-bottom thickness. Incorrect installation may cause frequent compressor cycling,
potentially leading to electrical circuit overload and degraded product performance.
The adhesive on the double-sided tape is extremely strong. Ensure the divider is properly positioned before
pressing it rmly into place.
① Represents the thickness from the RV ceiling to the bottom of the air conditioning unit.
Secure the panel mounting plate to the air conditioning unit using 4 mounting bolts. Using a torque wrench,
tighten the screws to a range of 1.8 ft-lbs ±0.22 ft-lbs, taking care not to over-tighten.
①Connect to the control panel.
2 Connect to the vehicle's power supply.
4.1 Electrical Connection
background
mrcool.com 20
20
POST-INSTALLATION
4
Install the ADB panel. Position the ADB over the top template, align its intake vent with the air return port of the
main unit and secure the screws in sequence.
①Air Intake Vent
2 Screws (x4)
①Air Outlet Control Slider
The airow can be adjusted by turning the air outlet control slider.
background
mrcool.com21
POST-INSTALLATION
4
4.2 Control Panel
The control panel is located at the air outlet of the roof-mounted air conditioner, as indicated in Figure 4-1.
Controls, buttons, and display icons are shown in Figure 4-2.
Figure 4-1
Figure 4-2
Button Descriptions:
Power On/O Button: Press this button to start the rooftop air conditioner or switch to standby mode.
Increase/Decrease the currently displayed value.
Select Air Conditioner Operating Mode.
Fan Speed Button.
Display Icon Legend:
The set temperature can be adjusted. The air conditioner will operate in Heating or Cooling mode to reach the
desired temperature with the fan speed set to Auto.
The set temperature and fan speed can be adjusted. The air conditioner will operate in Cooling mode.
The air conditioner operates in Dehumidication mode, which removes moisture from the air. In this mode,
the evaporator fan runs at a low speed.
Turn the Air Circulation mode On/O to move air without heating or cooling.
The set temperature and fan speed can be adjusted. The air conditioner will operate in Heating mode.
Turn Negative Ion Mode On/O.
Turn Sleep Mode On/O.
4.3 Remote Controller
Specications
Model MRDRC
Rated Voltage 3.0V (dry batteries R03/LR03x2)
Signal Receiving Range 26.24 ft (8m)
Environment 23°F~140°F (-5°C~60°C)
NOTE
• Buttons designs on your unit may dier slightly from the example shown.
• If the indoor unit does not have a particular function, press that function's button on the remote controller
will have no eect.
• If there is a dierence in the description of a unit's function between the "Remote Controller Manual" and
"Installation & Owner's manual", the information found in the "Installation & Owner's Manual" should take
precedent.
background
Contents
mrcool.com 22
POST-INSTALLATION
4
Quick-Start Guide
1. ON/OFF Button: Used to turn the air conditioner On/O.
Factory Default Settings: Cooling, Auto Fan, and display of the current room temperature (in Fahrenheit).
If it is not the unit's initial startup, the unit will remember the mode settings prior to power failure.
2. Mode Button: Switches the operating mode of the air conditioner.
Cycles through the modes in the following order: "Auto>Cool>Dry>Fan>Heat".
• Cooling Mode: By default, the set temperature (in Fahrenheit) is displayed and the fan speed is set to
Auto. If it is not the unit's initial startup, the unit will remember the temperature and the fan speed settings
prior to power failure.
• Dry Mode: By default, the temperature is not displayed and the fan speed is set to low. If it is not the unit's
initial startup, the unit will remember the Low Fan Speed setting prior to power failure.
• Fan Mode: By default, the fan speed is set to high. If it is not the unit's initial startup, the unit will
remember the fan speed setting prior to power failure.
• Heat Mode: By default, the set temperature (in Fahrenheit) is displayed and the fan speed is set to Auto.
If it is not the unit's initial startup, the unit will remember the temperature and fan speed settings prior to
power failure.
• Auto Mode: By default, the set temperature (in Fahrenheit) is displayed and the fan speed is set to Auto. If it
is not the unit's initial startup, the unit will remember the temperature and fan speed settings prior to power
failure.
3. Cool Button: Press this button to activate Cooling mode. The Cooling icon will remain on .
4. Turbo Button: Press this button to activate Turbo function. The Turbo icon will remain on .
• The Turbo function can be activated in Cooling and Heating modes. After exiting the Turbo function, the unit
defaults back to the mode settings prior to entering Turbo.
• When the Turbo function is activated, the fan speed is set to high and the corresponding characters are
displayed on the LCD screen.
• While the Turbo function is active, the Timer and Temperature buttons remain functional. Pressing the Mode
button, Fan Speed button, Sleep button, or ECO button will turn o the Turbo function.
Display Function:
background
mrcool.com23
POST-INSTALLATION
4
5. Auto Button: Can be used in all modes except Dry mode. Press this button to activate Auto Fan speed.
The fan speed bars will be displayed dynamically while the display screen continues to show the originally-
set temperature.
6. Increase Button: While in Auto, Cool, Fan, and Heat mode, each press increases the set temperature by 1°
increments, ranging from 61-90°F (16-32°C).
7. Decrease Button: While in Auto, Cool, Fan, and Heat mode, each press decreases the set temperature by 1°
increments, ranging from 90-61°F (32-16°C).
8. Fan Speed Button: Adjusts the fan speed of the air conditioner. Operation method: Low Fan/Sleep/ECO
(two bars) Medium Fan (four bars), High Fan (six bars).
Note: In Auto Fan mode, this icon is displayed dynamically.
9. Sleep Button: Press this button to activate the Sleep function. Pressing the button cycles through
"Sleep>Cancel Sleep>Sleep". The Sleep icon will be displayed .
• While the Sleep function is active, pressing the Turbo or ECO button will leave the Sleep function.
10. Fan Button: Press this button to activate Fan mode. The Fan icon will remain on .
11. Eco Button: Press this button to activate the ECO function. Pressing this button cycles through "ECO>Cancel
ECO>ECO".
12. Timer Button:
• When the unit is on, press the Timer button once to begin setting the shutoff timer. If no operation is
performed for 3 seconds, the setting is confirmed. To cancel the timer or reset it, press and hold the Timer
button for 3 seconds.
• When no timer is set, press the Timer button once. The remote control screen will display "1". The timer can
then be set using the Increase/Decrease buttons. Each press changes the time by one-minute increments.
While setting the timer, you can quickly cancel it by pressing and holding the Timer button for 3 seconds.
After 3 seconds of blinking, the setting is confirmed and the set temperature will be displayed again, and
the indicator light will turn on.
• When a timer is already set, press the Timer button once to display the remaining time until shuto. This
is shown for 3 seconds, then the display returns to showing the set temperature. Press and hold the Timer
button for 3 seconds to cancel the timer; the indicator light will turn o.
• Each time the Timer function is used, pressing the Timer button again to enter the Timer setting screen will
recall the previously-set timer.
14. Temperature Unit Conversion Button: The factory default setting is Fahrenheit. Press this button to
switch the displayed temperature value between Fahrenheit and Celsius. The corresponding character icon
will light up.
4.4 App Operation
1. Scan the QR code below with your smart device to download the MRCOOL® Connect app.
background
Contents
mrcool.com 24
4.5 Maintenance
Insert a at-head screwdriver or small knife into the handle and gently pull out the lter screen.
1. Remove the lter screen manually.
2. Clean the lter screen with water and allow it to dry.
3. Return the dried lter screen back into its position.
POST-INSTALLATION
4
2. Press and hold "MODE" on the display panel for 5 seconds until the Wi-Fi icon ashes.
3. Open the app and follow instructions to connect and congure Wi-Fi network compatibility.
4. The app interface appears as shown below once the Wi-Fi connection is successful.
Cleaning the Air Conditioner's Filter:
background
mrcool.com25
POST-INSTALLATION
4
4.6 Wiring Diagram
background
Contents
mrcool.com 26
5 - Troubleshooting
Fault Condition
Digital Display
Code
Fault or Protection Handling
Fault in Indoor Pipe Temperature Sensor E1/E2/E5
Indoor unit running, outdoor unit stopped; normal
operation restored after reset/recovery
Outdoor Coil Temperature Sensor Failure E6
Indoor unit running, outdoor unit stopped; normal
operation restored after reset/recovery
Exhaust Temperature Sensor Failure E7
Indoor unit running, outdoor unit stopped; normal
operation restored after reset/recovery
Indoor Fan Motor Failure E8
The entire unit stopped; it resumed normal
operation after troubleshooting
Outdoor Fan Motor Failure E9
Outdoor unit stopped and resumed normal
operation after troubleshooting
Exhaust Temperature Protection F0
Outdoor unit stopped and resumed normal
operation after troubleshooting
AC Overcurrent Protection F2 Unit shutdown; reboot unit
Compressor Phase Overcurrent Protection F3 Unit shutdown; reboot unit
DC Bus Overvoltage Protection F4 Unit shutdown; reboot unit
DC Bus Undervoltage Protection F5 Unit shutdown; reboot unit
AC Undervoltage Protection F6 Unit shutdown; reboot unit
Main Board, Driver Board Communication
Fault
F7
Indoor unit running, outdoor unit stopped; normal
operation restored after reset/recovery
Main Board, Display Board
Communication Fault
F8 Unit shutdown; reboot unit
IPM Over-Temperature Protection H1
Outdoor unit stopped and resumed normal
operation after troubleshooting
Compressor Starting Fault, Phase Loss or
Incorrect Phasing
H2 Unit shutdown; reboot unit
IPM Module Failure H3
Outdoor unit stopped and resumed normal
operation after troubleshooting
Compressor Out-of-Step or Stalling Failure H4
Outdoor unit stopped and resumed normal
operation after troubleshooting
Outdoor Low Temperature Safeguard for
Heating
C2
Unit halted, restarts after the temperature
normalizes
TROUBLESHOOTING
5
background
TravelCool™
The design and specications of this product and/or manual are subject to change without prior notice.
Consult with the sales agency or manufacturer for details.