0297
WARNING
Blood pressure that is too low represents just as great a
health risk as blood pressure that is too high! Fits of dizziness
may lead to dangerous situations arising (e.g. on stairs or in
trafc)!
Inuencing and evaluating readings
• Measure your blood pressure several times, then record and compare the
results. Do not draw any conclusions from a single reading.
• Your blood pressure readings should always be evaluated by a doctor who is
also familiar with your personal medical history. When using the unit regularly
and recording the values for your doctor, you should visit the doctor from time
to time to keep him updated.
• When taking readings, remember that the daily values are inuenced by
several factors. Smoking, consumption of alcohol, drugs and physical exertion
inuence the measured values in various ways.
• Measure your blood pressure before meals.
• Before taking readings, allow yourself at least ve minutes rest.
• If the systolic and diastolic readings seem unusual (too high or too low) on
several occasions, despite correct use of the unit, please inform your doctor.
This also applies to the rare occasions when an irregular or very weak pulse
prevents you from taking readings.
Getting started
Inserting / removing batteries
Insertion: Open the battery compartment on the
underside of the unit by
exerting gentle pressure in the direction indicated by the
arrow, and insert the four batteries included with the unit
(alkaline batteries, AA type, LR 6). Remember to insert
the batteries as indicated in the diagram in the battery
compartment. Replace the lid, pressing it until it snaps
into place.
Removal: When the battery symbol appears in
the display, please replace the batteries with new
ones. Should the used batteries be jammed in the
compartment, use a pointed instrument, such as a
ballpoint pen, to carefully prise them out. The display
showing the year will ash after inserting the batteries
for the rst time. Set the date and time as described in
„Set Date and Time“.
Please note that the date and time will have to be reset
each time new batteries are inserted. Previously stored
results will be lost.
Using a mains adaptor
Alternatively, you can use the unit with a special mains adaptor (medisana Art.–
No. 51036) This connects to the socket
6
provided at the back of the unit. In this
case the batteries remain in the unit. Inserting the connector into the back of the
blood pressure monitor switches the batteries off mechanically. It is necessary,
therefore, to plug the mains adaptor into the mains socket rst of all and then
to connect it to the blood pressure monitor. If the blood pressure monitor is no
longer being used, rst remove the connector from the blood pressure monitor
and then pull the mains adaptor out of the mains socket. Doing this means that
the date and time will not have to be reset each time.
Set Date and Time
To set date and time press and hold the TIMER button
5
for several seconds.
The symbol for the memory selected starts ashing. Now press the TIMER button
5
again briey. The year is now shown in the display and starts ashing. Press
the MEMORY button
4
to change the year. Press the TIMER button
5
to go to
month, day and time. Press the MEMORY button
4
to change the values.
Setting up the user memory
The MTP gives you the opportunity to assign readings to one of two user
memories, each of which provides 99 memory slots. Press and hold the TIMER
button
5
for several seconds. The symbol for memory (USER) 1 in the
display
3
starts ashing. You can switch between USER 1 and USER 2 by
pressing the MEMORY button
4
.
Fitting the cuff
First attach the free end of the cuff’s air tube to the designated connector
3
on
the unit. Open up the cuff to a ring and slip it over the bare left upper arm just
above the elbow region. If wearing tight clothing, ensure that the circulation in the
arm is not impaired when rolling up the sleeve. Please ensure that the cuff buckle
is never positioned directly over the artery, as this can result in an incorrect blood
pressure reading. The tube should run along the center of the inner arm towards
the palm of the hand. Ensure that the cuff itself is not twisted in any way.
Fasten the pressure cuff in such a way that it ts tightly but does not constrict the
arm. Do this by passing the end through the buckle, pulling it tight and attaching
it to the Velcro fastener.
Correct position for taking readings
• Take readings while in a seated position.
• Relax your arm and rest it lightly on a surface such as a table. Relax during the
measuring process: do not move or talk, as this can affect the results.
GB
Instruction manual
Upper arm blood pressure measuring device MTP
Explanation of symbols
This instruction manual belongs to this device. It contains important information
about starting up and operation. Read the instruction manual thoroughly.
Non-observance of these instructions can result in serious injury or damage
to the device.
WARNING
These warning notes must be observed to prevent any injury to the
user.
CAUTION
These notes must be observed to prevent any damage to the
device.
NOTE
These notes give you useful additional information on the installation or
operation.
Classication: Type BF applied part
LOT number
Manufacturer
Date of manufacture
Read the instruction manual carefully before using this device,
especially the safety instructions, and keep the instruction
manual for future use. Should you give this device to another
person, it is vital that you also pass on these instructions for
use.
• Irregularity of pulse or arrhythmia can lead to difculties in recording a correct
reading when measurements are taken using oscillometric blood pressure
devices.
• If you should suffer from conditions such as arterial occlusive disease, please
consult your doctor before using the unit.
• The unit may not be used to check the heart rate of patients with a pacemaker.
• Pregnant patients should take their own personal state of health into consideration
and take all necessary precautions before using the unit. If in doubt, consult your
doctor.
• Should you experience discomfort or other complaints during measurement,
for example pain in the upper arm, please take the following action: Press the
START button
2
to deate the cuff immediately. Loosen the cuff and remove it
from your arm. Please contact either your dealer or medisana directly.
• Patients with a weak pulse wave should raise their arm and open and close their
hand around 10 times before taking a reading. This exercise optimizes the pulse
wave and the measuring process.
• The unit is only to be used for the specic purpose described in this instruction
manual.
• Any misuse will void the warranty.
• On the rare occasion of a fault causing the cuff to remain fully inated during
measurement, open the cuff immediately.
• Do not use the unit near to equipment emitting a strong electric or magnetic eld,
such as radios. This may impair the correct functioning of the unit.
• This device is not designed to be used by persons (including children) with limited
physical, sensory or mental abilities, or by persons with insufcient experience
and/or knowledge, unless under observation by a person responsible for their
safety, or unless they have been instructed in the use of the device.
• Children must be supervised to ensure that they do not play with the device.
• If a fault occurs, do not try to repair the unit yourself. Attempts to do so will void
the warranty. Refer all servicing to authorized service personnel.
• Protect the unit from moisture. Should moisture enter the unit, remove the
batteries and stop using it immediately. In this case, please contact either your
dealer. You can nd details of how to contact us on the address page.
BATTERY SAFETY INFORMATION
• Do not disassemble batteries!
• Clean the battery and device contacts if necessary before putting in the batteries!
• Remove discharged batteries from the device immediately!
• Increased risk of leakage, avoid contact with skin, eyes and mucous membranes!
If battery acid comes in contact with any of this parts, rinse the affected area with
copious amounts of fresh water and seek medical attention immediately!
• If a battery has been swallowed seek medical attention immediately!
• Replace all of the batteries simultaneously!
• Only replace with batteries of the same type, never use different types of batteries
together or used batteries with new ones!
• Insert the batteries correctly, observing the polarity!
• Remove the batteries from the device if it is not going to be used for an extended
period!
• Keep batteries out of children‘s reach!
• Do not attempt to recharge these batteries! There is a danger of explosion!
• Do not short circuit! There is a danger of explosion!
• Do not throw into a re! There is a danger of explosion!
• Keep unused batteries in their packaging away from metal objects in order to
prevent short circuiting!
• Do not throw used batteries into the household refuse; put them in a
hazardous waste container or take them to a battery collection point, at
the shop where they were purchased!
How is blood pressure measured?
The MTP is a blood pressure unit which is used to measure blood pressure at
the upper arm. The measurement is carried out by a microprocessor, which, via a
pressure sensor, measures the vibrations resulting from the ination and deation
of the cuff over the artery.
Why should you take your blood pressure at home?
One strong argument in favour of taking blood pressure at home is the fact that
the readings are taken in familiar surroundings under relaxed conditions. The most
important reading is the socalled „baseline value“, the one taken before breakfast,
directly after getting up in the morning. As far as it is possible, you should always
try to take your blood pressure at the same time and under the same conditions
each day. This ensures comparable results and helps in detecting the rst signs of
high blood pressure. If high blood pressure remains undetected, it increases the
risk of further cardiovascular diseases.
Blood pressure classication Taking blood pressure readings
a. Press the START button
2
.
• All the display symbols will appear for approx. two seconds.
• The cuff
1
will then inate. The increasing pressure is displayed numerically.
• Pressing the START button
2
during ination will stop the ination process. The
unit switches off and the cuff deates.
b. The measuring process begins automatically when ination is complete by
releasing the pressure built up in the cuff. The display shows the current
pressure in the cuff.
Initially, deation occurs at a constant speed. As soon as the pulse can be
determined, deation is synchronised with the beating of the heart until the
measurement ends. This procedure is accompanied by a beep and the heart
symbol ashes at the same time. The measurement is complete when the cuff
suddenly deates and readings are displayed next to SYS, DIA and PUL.
Storing results
This unit features 2 separate memories, each with a capacity of 99 memory slots.
Results are automatically stored in the memory selected by the user. When the
memory is full, the oldest reading is always the rst to be deleted.
Displaying stored results
Press the MEMORY button
4
to display the stored readings. First, an average
value of all the measurements in the selected memory is displayed. This average
is indicated by “ ”.
When the MEMORY button
4
is pressed again, the individual readings (switching
between systolic, diastolic, pulse and date/time) of the last measurement stored
are displayed. Press the MEMORY button
4
again to move backwards through
the stored readings.
If you do not press any buttons for approx. 1 minute, the device automatically
switches back to standby mode.
Deleting memory
The data can be deleted from the memory selected by pressing and holding the
MEMORY button
4
for about 7 seconds. After 7 seconds, the display
3
shows
“ ” ( CLEAR ) which indicates that all data have been deleted.
Switching off the unit
The unit switches off automatically after about 1 minute, if no button is pressed
during this period. It can also be switched off by pressing the START button
2
.
The time and the personal memory selected are constantly shown in the display
3
.
Troubleshooting
Err 1: Measurement of the systolic blood pressure was completed.
Either the connection with the hose has been interrupted or no pulse could be
determined. Check the connections between the cuff and the main unit.
Err 2: Non-physiological pressure has been detected.
Cause: the arm was moved during the measurement. Repeat the measurement,
keeping your arm still.
Err 3: If the cuff takes too long to inate, it is possible that the cuff is incorrectly
positioned or that the connection with the hose is not airtight. Check the
connections and repeat the measurement. If the same error occurs repeatedly
with further readings, please contact medisana.
Err 5: An average value could not be calculated due to unstable conditions while
the readings were being taken. Repeat the measuring process, keeping your arm
still and not speaking.
Err 6: There were too many errors during the measurement in MAM mode, making
it impossible to obtain a nal result. Read through the checklist for performing
reliable measurements and then repeat the measurement.
Warranty and repair terms
Please contact your supplier or the service centre in case of a claim under the
warranty. If you have to return the unit, please enclose a copy of your receipt and
state what the defect is.
The following warranty terms apply:
1. The warranty period for medisana products is 10 years from date of purchase.
In case of a warranty claim, the date of purchase has to be proven by means of
the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the
warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for
the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. nonobservance of
the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the
consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are excluded
even if the damage to the unit is accepted as a warranty claim.
medisana GmbH
Carl-Schurz-Str. 2, 41460 NEUSS, GERMANY
Device and controls
Items supplied and packaging
Please check rst of all that the device is complete and is not damaged in any way. In
case of doubt, do not use it and contact your dealer or your service centre.
The following parts are included:
• 1 medisana Blood pressure monitor MTP
• 1 Cuff with air hose • 4 Batteries (AA type, LR 6) 1.5V
• 1 Storage bag • 1 Instruction manual
The packaging can be reused or recycled. Please dispose properly of any
packaging material no longer required. If you notice any transport damage
during unpacking, please contact your dealer without delay.
THEREFORE WE RECOMMEND:
Take a blood pressure reading daily and on a regular basis,
even if you are experiencing no apparent complaints.
WARNING
• Do not take any therapeutic measures based on your own mea-
surements! Never change the quantity of medication prescribed
by your doctor!
• Please ensure that the polythene packing is kept away from the
reach of children! Risk of suffocation!
Note
When the device is used, the errors Err 1, 2, 3, 5, 6 can occur in the
integrated circuit. The error display is always accompanied by 3
short beeps.
Care and maintenance
• Remove the batteries before cleaning the unit.
• Never use strong detergents or hard brushes.
• Clean the unit with a soft cloth, moistened with mild soapy water. Do not let water
enter the unit. After cleaning, only use the unit when completely dry.
• Remove the batteries from the unit if you do not wish to use it for an extended
period of time, otherwise there is a risk of battery leakage.
• Do not expose the unit to direct sunlight, and protect it from dust and moisture.
• Only inate the cuff when it is in position around the upper arm.
• Servicing and calibration: The unit has been calibrated by the manufacturer for a
period of two years’ use. In the case of commercial use, the unit must be serviced
and recalibrated at least once every two years. This calibration will be charged
for and can be carried out by an appropriate authority or an authorised service
centre - in accordance with the regulations for users of medical equipment.
Disposal
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be disposed
of in an environmentally acceptable manner.
Please remove the battery before disposing of the device/unit. Do not
dispose of old batteries with your household waste, but at a battery
collection station at a recycling site or in a shop. Consult your municipal authority
or your dealer for information about disposal.
Directives / Norms
This blood pressure monitor meets the requirements of the EU standard for non-
invasive blood pressure monitors. It is certied in accordance with EC Guidelines
and carries the CE symbol (conformity symbol) “CE 0297”. The blood pressure
monitor corresponds to European standards EN 60601-1, EN 60601-1-2, EN
80601-2-30, EN 1060-1/3, EN ISO 14971 and EN 15223-1. The specications of
EU Guideline “93/42/EEC of the Council Directive dated 14 June 1993 concerning
medical devices” are met.
Clinical trial results: Clinical trial for this unit was carried out in England according
to the BHS protocol and according to the AAMI – Standard (US).
Intended use: This unit is suitable for non-invasive blood pressure measurement in
adults (i.e., suitable for external use).
Technical specications
Name and model: medisana Upper arm blood pressure monitor
MTP
Display system: Digital display
Memory slots: 2 x 99
Measuring technique: Oscillometric
Power supply: 6 V , 4 x 1.5 V Mignon AA LR 6, Alkaline
Blood pressure measuring range: 30 – 280 mmHg
Pulse measuring range: 40 – 200 beats / min.
Maximum error tolerance for static pressure: ± 3 mmHg
Maximum error tolerance for pulse rate:
± 5 % of the value
Pressure generation: Automatic, using micro pump
Deation: Automatic
Automatic switch-off: After approx. 1 minute
Operating conditions: + 10 °C to + 40 °C, 15 - 85 % humidity
Storage conditions: - 5 °C to + 50 °C
Dimensions: Approx. 120 x 163 x 66 mm
Cuff size: 22 - 32 cm Adult cuff for average upper arm
circumference
Weight: approx. 480 g incl. batteries
Article number: 48681
EAN number: 40 15588 48681 4
Accessories: Mains adapter, Art.-No. 51036
In accordance with our policy of continual product
improvement, we reserve the right to make technical and
optical changes without notice.
systolic
mmHg
≥ 180
160 - 179
140 - 159
130 - 139
120 - 129
< 120
≥ 110
100 - 109
90 - 99
85 - 89
80 - 84
< 80
serious hypertension
medium hypertension
mild hypertension
high-normal blood pressure
normal blood pressure
optimal blood pressure
diastolic
mmHg
48681_MTP_manual_GB_202204_L1
GB Safety Information
5
4
6 7
2
3
1
1 Upper arm cuff with hose 2 START button
3 Display 4 MEMORY button
5 TIMER button 6 Socket for mains adaptor
7 Connector for the hose