Harbor Breeze GTA52MWW3R Stokes II Easy2Hang 52-in Matte White Covered Outdoor Downrod or Flush Mount Propeller Ceiling Fan Without Light and Remote Control Included

Product's Documents

Below are documents related to this product, you can read online or download:
GTA52MWW3R photo

Installation Manual

This is the main product document for model GTA52MWW3R.

The file format is pdf, 18 pages, you can download this manual here .

background
Purchase Date
Español p. 19
ATTACH YOUR RECEIPT HERE
STOKES II CEILING FAN
1
Questions, problems, missing parts? Before returning,
contact us on:
800-527-1292, 8:30 a.m. - 5 p.m., CST, Monday - Friday.
ITEM #6245872, 6245873, 6280272
MODEL #GTA52BNK3R, GTA52GD3R, GTA52MWW3R
4009218
APPROVED FOR USE
IN DAMP LOCATIONS
background
2
Safety Information ...................................................................................................................................
.
. 2
Package Contents .................................................................................................................................... 5
Hardware Contents
.................................................................................................................................................
6
Preparation ............................................................................................................................................... 6
Initial Installation ....................................................................................................................................... 6
Downrod-Style Fan Mounting ................................................................................................................... 9
Closemount-Style Fan Mounting ............................................................................................................ 11
Wiring ..................................................................................................................................................... 12
Final Installation ..................................................................................................................................... 14
Operating Instructions ............................................................................................................................ 15
Care and Maintenance ......................................................................................................................
.
.... 16
Troubleshooting ...................................................................................................................................... 17
Limited Lifetime Warranty ....................................................................................................................... 18
Replacement Parts List .......................................................................................................................... 18
TABLE OF CONTENTS
CAUTION: Changes or modifications not approved by the party responsible for compliance could
void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, (2) this device must accept any interference
received, including interference that may cause undesired operation.
Distributed by: Litex Industries Inc., P.O. Box 535639, Grand Prairie, TX, 75050; 800-527-1292
SAFETY INFORMATION
background
3
READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, install or operate
the product. Review the accompanying assembly diagrams.
• Do not discard fan carton or packing material. Should this fan need to be returned to the factory for
repairs, it must be shipped in its original packaging to ensure proper protection against damage that
might exceed the initial cause for return.
• Make sure all electrical connections comply with local codes, ordinances, the National Electrical Code
and ANSI/NFPA 70-1999. Hire a qualified electrician or consult a do-it-yourself wiring handbook if you
are unfamiliar with installing electrical wiring.
• Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to the
floor and at least 30 in. from the end of the blades to any obstruction.
• After you install the fan, make sure all connections are secure to prevent the fan from falling.
• The net weight of this fan is: 14.77 lbs.
SAFETY INFORMATION
To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box
marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. OR LESS" and use mounting
screws provided with the outlet box. Most outlet boxes commonly used for the support of
lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.
To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp
edges.
To reduce the risk of fire, electrical shock or personal injury, lever wire connectors provided with this
fan are designed to accept only one 12-gauge house wire and one lead wires from the fan. If your
house wire is larger than 12-gauge or there is more than one house wire to connect to the
corresponding fan lead wires, consult an electrician for the proper size lever wire connectors to use.
WARNING
DANGER
When using an existing outlet box, make sure the outlet box is securely attached to the building
structure and can support the full weight of the fan. Failure to do this can result in serious injury or
death. The stability of the outlet box is essential in minimizing wobble and noise in the fan after
installation is complete.
To reduce the risk of serious bodily injury, DO NOT use power tools to assemble any part of the fan,
including the blades.
Before proceeding, be sure to shut off electricity at main switch or circuit breaker in order to avoid
electrical shock.
background
4
The DC Motor will not operate until blades are installed.
SAFETY INFORMATION
CAUTION
Be sure outlet box is properly grounded and that a ground wire (GREEN or BARE) is present.
Once installation is complete, carefully check all screws, bolts and nuts on fan motor assembly to
ensure that they are secured.
When mounting fan to a ceiling outlet box, use a METAL octagonal outlet box; do NOT use a plastic
outlet box. Secure the outlet box directly to the building structure. The outlet box and its support must
be able to support the moving weight of the fan (at least 35 lbs.).
To reduce the risk of fire or electrical shock, do not use the fan with any solid state speed control
device or control fan speed with a full range dimmer switch.
To reduce the risk of fire, electrical shock or personal injury, do not bend the blades when installing or
balancing them or when cleaning the fan. Do not insert objects between the rotating fan blades.
To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER
than those provided with this fan will void the warranty.
WARNING
background
5
K
PACKAGE CONTENTS
A
D
B
F
C
J
I
E
N
M
H
G
A Downrod 1
B Canopy 1
C Mounting Bracket 1
(preassembled)
D Motor Housing 1
E Yoke Cover 1
F Motor 1
G Canopy Mounting Screw/ Lock 4
Washers (preassembled)
DESCRIPTIONPART
QUANTITY
IMPORTANT REMINDER: You must use the
parts provided with this fan for proper installation
and safety.
DESCRIPTIONPART
QUANTITY
H Pin (preassembled) 1
I Clip (preassembled) 1
J Blade 3
K Blade Plate 3
L Remote Control Receiver 1
M Remote Pack 1
N Additional Wiring 1
L
background
6
Blade Screw/
Lock Washer
Qty. 6
+ 1 extra
BB
Lever Wire
Connector
Qty. 3
Before beginning assembly of product, make sure all parts are present. Place motor on carpet or on
foam to avoid damage to nish. Compare parts with package contents list and hardware contents list. If
any part is missing or damaged, do not attempt to assemble the product.
Estimated Assembly Time: 120 minutes
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,
Stepladder and Wire Strippers
Helpful Tools (not included): AC Tester Light, Tape Measure, Do-It-Yourself Wiring Handbook and Wire
Cutters
PREPARATION
Turn off circuit breakers or fuse and wall switch
to the fan supply line leads.
DANGER: Failure to disconnect power
supply prior to installation may result in serious
injury or death.
1.
INITIAL INSTALLATION
ON
OFF
ON
OFF
1
background
7
3.
Determine mounting method to use.
A. Downrod mount (standard or angled ceiling).
B. Closemount (standard ceiling only).
IMPORTANT: If using the angle mount, check to
make sure the ceiling angle is not steeper than 19°.
*Helpful Hint: Downrod-style mounting is best
suited for ceilings 8 ft. or higher. For taller ceilings
you may want to use a longer downrod (not
included). Angle-style mounting is best suited for
angled or vaulted ceilings. A longer downrod is
sometimes necessary to ensure proper blade
clearance. Closemount mounting is more suitable
for ceilings lower than 8 ft. high.
2.
2
If applicable, remove existing fan, including the
mounting bracket, from outlet box and
disconnect all electrical wiring.
WARNING: To reduce the risk of personal
injury, use ONLY parts provided with your new
fan. The use of parts OTHER than those
provided with this fan will void the warranty.
Set aside screws, spring washers and flat
washers provided with the outlet box for fan
installation.
INITIAL INSTALLATION
A
B
3
19° max.
Check to make sure blades (J) will be at least
30 in. from any obstruction and at least 7 ft.
above the floor.
4.
7 ft.
min.
30 in.
min.
J
4
background
8
INITIAL INSTALLATION
5a
5a.
Loosen canopy mounting screws/lock washers (G)
in slotted holes of canopy (B) and remove the
other two canopy mounting screws/lock washers
(G) -- save for later use.
Remove mounting bracket (C) from canopy (B).
C
B
G
G
5b.
5b
Open End
C
C
Secure mounting bracket (C) to outlet box (not
included) using screws, spring washers and flat
washers provided with the outlet box. [These
may have been previously removed in Step 2,
page 7.]
*NOTE: It is very important you use the proper
hardware when installing the mounting bracket
(C) as this will support the fan.
IMPORTANT: If using the angle mount, make
sure open end of mounting bracket (C) is
installed facing the higher point of the ceiling,
and ensure the ceiling angle is not steeper than
19°.
ANGLE
MOUNT
STANDARD
MOUNT
6
K
F
AA
AA
J
6.
Hardware Used
Blade Screw/Lock Washer x 6
AA
DANGER: To reduce the risk of serious bodily
injury, DO NOT use power tools to assemble the
blades (J). If overtightened, blades (J) may crack
and break.
Place blade (J) onto border of motor (F) aligning
holes. Place one blade plate (K) on top of blade
(J) aligning holes. Insert one blade screw/lock
washer (AA) into each of the holes, turning until
the blade screws/lock washers (AA) are secure.
Tighten both blade screws/lock washers (AA) with
a Phillips screwdriver (not included).
Repeat for the other blades (J) and blade plates
(K).
DANGER: To reduce the risk of personal
injury, make sure all blades (J) and blade
plates (K) are completely secure before
proceeding.
background
9
INITIAL INSTALLATION
7.
7
F
Thread wires from motor (F) through opening in
top of motor housing (D). Use gap in hole at top of
motor housing (D) to get motor housing (D) past
set screw in yoke.
Align 3 holes on topside of motor housing (D) with
3 preassembled rubber soft nails in yoke, and
press down firmly on the motor housing (D) to
attach motor housing to motor (F).
IMPORTANT: Do NOT remove preassembled
rubber soft nails. The heads of the preassembled
rubber soft nails must protrude through the holes
in motor housing (D) for a secure fit.
Set Screw
Yoke
Rubber
soft nails
A
2.
2
E
B
DOWNROD-STYLE FAN MOUNTING
Insert downrod (A) through canopy (B) and yoke
cover (E). Thread wires from motor (F) up
through downrod (A).
Remove pin (H) and clip (I) from downrod (A).
Partially loosen preassembled set screws and
nut in yoke at top of motor (F).
1a.
1b.
1b
Yoke
Set Screw
& Nut
Sideview
1a
I
H
A
F
D
Gap
background
10
3.
3
A
I
H
Set Screw
and Nut
E
Slip downrod (A) into yoke, align holes and
re-install pin (H) and clip (I). Tighten set screws
and then tighten nut. Slide yoke cover (E) down
until it rests on top of motor housing (D).
D
5.
Install hanging ball of downrod (A) into opening of
mounting bracket (C). Align one of the slots in
hanging ball with the tab in mounting bracket (C).
DANGER: Failure to align slot in hanging ball
with the tab in mounting bracket (C) may result in
serious injury or death.
Continue to WIRING on page 12.
C
Tab
5
A
Slot
N
F
Depending on the length of downrod you use,
you may need to use the additional wiring (N).
Connect male plug from motor (F) to the end of
additional wiring (N) with female plug. Make sure
plugs connect tightly.
NOTE: If you do not use additional wiring (N),
Step 4 is not necessary and you may proceed
to Step 5 instead.
4.
4
DOWNROD-STYLE FAN MOUNTING
background
11
CLOSEMOUNT-STYLE FAN MOUNTING
1.
Pull wires up through hole in the middle of the
canopy (B) and attach canopy (B) to motor (F)
using the three previously removed screws/lock
washers.
3.
3
2. Remove 3 preassembled screws/lock washers
from yoke on top of motor (F).
2
Screw/Lock Washer
Remove preassembled canopy cover from
bottom of canopy (B). [NOTE: It may be
necessary to use the handle end of a
screwdriver (not included) to remove the canopy
cover by tapping on the canopy cover from the
inside of the canopy (B).]
NOTE: The downrod (A), yoke cover (E) and
canopy cover are not used in this type of
installation.
Canopy
Cover
B
1
B
F
B
F
background
12
CLOSEMOUNT-STYLE FAN MOUNTING
Temporarily hang fan on the tab on the mounting
bracket (C) using one of the non-slotted holes in
the canopy (B).
Continue to WIRING below.
4.
B
4
C
Tab
WARNING: To reduce the risk of fire, electrical shock or personal injury, lever wire connectors
provided with this fan are designed to accept only one 12-gauge house wire and one lead wires from the
fan. If your house wire is larger than 12-gauge or there is more than one house wire to connect to the
corresponding fan lead wires, consult an electrician for the proper size lever wire connectors to use.
CAUTION: Be sure outlet box is properly grounded and that a ground (GREEN or BARE) wire is
present.
WARNING: If house wires are different colors than referred to in the following steps, stop
immediately. A professional electrician is recommended to determine wiring.
WARNING: Using a full range dimmer switch (not included) to control fan speed will cause a loud
humming noise from fan. To reduce the risk of fire or electrical shock, do NOT use a full range dimmer
switch to control fan speed.
WIRING
background
2
L
WHITE SUPPLY WIRE
BLACK SUPPLY WIRE
BLACK
AC IN L
WHITE AC IN N
WHITE
GROUND (GREEN OR BARE)
GROUND
(GREEN OR BARE)
GREEN
BLACK
FROM
RECEIVER
FROM
FAN
FROM
RECEIVER
FROM
CEILING
C
BB
A
13
WIRING
2.
Insert each GROUND (GREEN) wire from fan
(on downrod (A), remote control receiver (L)
and mounting bracket (C)) and the
BARE/GREEN wire from ceiling into openings
in lever wire connector (BB) with four levers.
Insert BLACK wire from remote control receiver
(L) and BLACK wire from ceiling into openings
in lever wire connector (BB).
Insert WHITE wire from remote control receiver
(L) and WHITE wire from ceiling into openings
in lever wire connector (BB).
Connect plug from remote control receiver (L)
to plug from motor (F).
NOTE: BLACK wire is hot power for fan.
WHITE wire is common for fan and light kit.
GREEN or BARE wire is ground.
1.
IMPORTANT: Each wire connection is made by
firmly raising the levers on each lever wire
connector (BB), as shown. Then, ONE wire is
inserted into each opening.
WARNING: In order for wire connections to
be secure, all levers on the lever wire
connectors (BB) must be completely returned
to their original position as shown on Step 2.
1
BB
3.
Wrap electrical tape (not included) around each
individual lever wire connector (BB) down to the
wire.
WARNING: Make sure no bare wire or
wire strands are visible after making
connections. Place GREEN and WHITE
connections on opposite side of the outlet box
from the BLACK and BLUE (if applicable)
connections.
WARNING: GENTLY pull on wires in each
lever wire connector (BB) to confirm the lock is
engaged and that wires are secure.
Lever Wire Connector x 3
Hardware Used
BB
BB
3
BB
BB
background
14
4
Gently slide remote control receiver (L) flat-side
up into mounting bracket (C). Turn spliced/taped
wires upward and gently push wires and lever
wire connectors (BB) into outlet box. Let antenna
from remote control receiver (L) hang to the side.
NOTE: The remote control included with this fan
meets the following requirements:
a. Not for use with solid state fans.
b. Electrical rating: 120V / 60 Hz;
motor amps:1.25 MAX.
Should you choose to use a different remote
control with this fan, it must also meet these same
requirements.
4.
Antenna
A
L
C
WIRING
FINAL INSTALLATION
1.
Lift canopy (B) to mounting bracket (C), aligning
slotted holes in canopy (B) with loosened canopy
mounting screws/lock washers (G) in mounting
bracket (C). Twist canopy (B) clockwise to lock.
Re-insert the two canopy mounting screws/lock
washers (G) that were previously removed (Step
5a, page 8) and tighten all canopy mounting
screws/lock washers (G) securely.
1
Downrod
Option
Closemount
Option
B
G
F
G
F
B
background
OPERATING INSTRUCTIONS
CAUTION: The remote control transmitter can be programmed to multiple receivers or fans. If this is
not desired, turn wall switch off to any other programmable receiver or fan.
FCC Compliance Notice for Remote Control.
CAUTION: Changes or modifications not approved by the party responsible for compliance could
void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Litex Industries Inc., P.O. Box 535639, Grand Prairie, TX, 75050; 800-527-1292
Locate remote control transmitter in remote pack (M).
Remove battery cover. Install two AAA batteries from
remote pack (M). Observe diagram inside battery
compartment to install batteries correctly.
WARNING: Batteries are to be inserted with
correct polarity.
WARNING: Choking/Ingestion Hazard - Small
parts. Keep batteries away from children.
NOTE: DO NOT mix old and new batteries; DO NOT
mix alkaline, standard (carbon - zinc) or rechargeable
(nickel - cadmium) batteries or equivalent.
NOTE: Batteries are NOT rechargeable. Remove
batteries with low or no charge and dispose of
properly.
1.
1
Battery
Cover
Remote Control
Transmitter (back side)
Batteries
AAA
-
+
-
+
AAA
M
CAUTION: “DO NOT DISPOSE OF BATTERIES IN FIRE, BATTERIES MAY EXPLODE OR LEAK.”
- When disposing of household alkaline batteries, it is best to check with your local and state recycling
or household hazardous waste coordinators concerning the specifics of the program in your area. You
may also locate a recycling center by calling 1-800-8-BATTERY or 1-877-2-RECYCLE or visit
www.epa.gov/epawaste/index.htm or www.earth911.org for more information.
15
background
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
At least twice each year, lower canopy (B) to check downrod (A) assembly, canopy mounting
screws/lock washers (G) and then tighten all screws on the fan. Clean motor housing (D) with only a soft
brush or lint-free cloth to avoid scratching the finish. Clean blades (J) with a lint-free cloth.
IMPORTANT: Shut off main power supply before beginning any maintenance. Do not use water or a
damp cloth to clean the ceiling fan.
2.
Restore electrical power. Replace battery cover.
IMPORTANT: To prevent damage to remote
control transmitter, remove the battery if not used
for long periods. Store the remote control
transmitter away from excess heat or humidity.
NOTE: If fan and/or remote control fail(s) to
operate or you have purchased a new remote
control transmitter, make sure to turn the power off
first. Restore electrical power. Within 30 seconds
of powering fan, press and hold ON/OFF button
( ) on remote control transmitter for 5 seconds
until fan beeps once in order to synchronize
remote with fan motor. Use the remote control
transmitter to test the fan functions to confirm the
learning process is complete.
Remote Control Transmitter
(back side)
2
3.
Operation buttons on the front panel of the remote
control transmitter:
- Reverse function: fan must be set on low
before reversing blade direction
- Fan speeds: 1 (lowest) to 6 (highest) and
to turn fan ON
- OFF power button for fan.
- Timer mode: fan may be set to run for
– 1 hour / 4 hours / 8 hours
- Breeze mode: fan automatically cycles
between all 6 different speeds
3
1
2
4
5
Remote Control Transmitter
3
1
3
2
4
5
16
background
WARNING: Before beginning work, shut off the power supply to avoid electrical shock.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fan does not move. 1. Power is off or fuse is blown.
2. Faulty wire connection.
3. Learning code process between
fan and remote control transmitter
may not have been successful
and learning code was not
activated.
4. Blades are not installed.
1. Turn power on or check fuse.
2. Turn power off. Loosen canopy and
check all connections.
3. Turn off power and repeat
instructions in Step 2 on page 16.
4. Install all blades (see page 8).
Noisy operation.
1. Blades are loose.
2. Cracked blade.
3. Fan is new.
4. Motor housing is loose.
1. Tighten all blade screws.
2. Replace blade.
3. Allow fan a “break in” period of a few
days, especially when running the
fan at Medium and High speeds.
4. Securely attach motor housing (see
Page 9).
Excessive wobbling.
1. Blades are loose.
2. Unbalanced blades.
3. Fan not securely mounted.
4. Fan too close to vaulted ceiling.
5. Set screw(s) on motor yoke is (are)
not tightened properly.
6. Set screw on hanging ball is not
tightened properly.
1. Tighten all blade screws.
2. Switch one blade with a blade from
the opposite side.
3. Turn power off. Carefully loosen
canopy and verify that mounting
bracket is secure.
4. Use a longer downrod or move fan to
another location.
5. Tighten yoke set screw(s) securely.
6. Carefully loosen and lower canopy
and verify that set screw on hanging
ball is tightened securely.
NOTE: A small amount of "wobble" is normal and should not be considered a defect.
Remote control fails
to operate.
1. Remote control transmitter not
synced with fan.
2. Battery not installed correctly.
3. Battery no longer working.
1. Refer to instructions in Step 2 on
page 16.
2. Check that battery has been installed
with correct polarity.
3. Replace battery according to
instructions on page 15.
17
background
LIMITED LIFETIME WARRANTY
Set forth below, the manufacturer warrants the fan motor for this ceiling fan to be free from defects in
workmanship and material for the life of the product. Also, subject to the limitations below, the
manufacturer warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in
whole or in part with glass) to be free from defects in workmanship and material for a period of one year
after the date of purchase by the original purchaser at retail.
All claims must be made by the original purchaser, whether such purchaser purchased the product
through a store or contractor. Ceiling fan part defects must be reported within the first year from the date
of purchase. Parts made in whole or in part with glass and the finishes of metal and other surfaces are
not warranted.
Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any
part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by this
warranty. The manufacturer assumes no responsibility whatsoever for fan installation. Any service
performed by a non-licensed electrician will render the warranty invalid.
The manufacturer’s sole responsibility shall be to repair or replace the motor, parts, or product within the
terms stated above. The manufacturer shall not be liable for any loss or damage of any kind, including
any incidental or consequential damages resulting directly or indirectly, from any breach of warranty,
express or implied, or any other failure of this product. Some states do not allow the exclusion or
limitation of incidental or consequential damages so this limitation may not apply to you.
If the original purchaser ceases to own the fan, this warranty is voided.
Should the purchaser encounter a problem with your fan related to defects in workmanship or materials
within the warranty period associated with the defective part, the manufacturer agrees to replace the
defective part without charge, or at its option, to replace the ceiling fan with a comparable or superior
model.
The manufacturer’s warranties are limited to the written warranties set out in this ceiling fan limited
lifetime warranty. All other express and implied warranties, including, without limitation, the implied
warranty of fitness for a particular purpose and the implied warranty of merchantability are disclaimed.
Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.
J
A
B
C
REPLACEMENT PARTS LIST
18
For replacement parts, call our customer service department at 888-251-1003, 8 a.m. - 8 p.m., EST,
Monday - Sunday. You could also contact us at [email protected].
DRLI2402
Printed in China
A Downrod
B Canopy
C Mounting Bracket
J Blade
6245872-A
6245872-C
6245872-F
6245872-J
#
6245872
PART
#
#
6245873
PART
#
6245873-A
6245873-C
6245873-F
6245873-J
PART DESCRIPTION

Specifications

Harbor Breeze GTA52MWW3R Questions and Answers

Questions and Answers

Related Products