Harbor Breeze 43013 Kennerly 44-in White LED Covered Outdoor Ceiling Fan With Light and Pull Chain Included

Product's Documents

Below are documents related to this product, you can read online or download:
43013 photo

Installation Manual

This is the main product document for model 43013.

The file format is pdf, 19 pages, you can download this manual here .

background
1
HARBOR BREEZE and logo design are trademarks or
registered trademarks of LF, LLC. All rights reserved.
ATTACH YOUR RECEIPT HERE
ITEM #5497051/5497052/5497053/5497054
MODEL #42965/43013/43014/43015
KENNERLY
CEILING FAN
DF25076
Español p. 20
LISTED FOR
DAMP
LOCATIONS
Purchase Date _________________________
Thank you for purchasing this HARBOR BREEZE product.
Questions, problems, or missing parts?
Before returning, contact us at:
888-251-1003, 8 a.m. - 8 p.m., EST, Monday - Sunday or at [email protected].
background
2
TABLE OF CONTENTS
Package Contents .................................................................3
Hardware Contents ................................................................4
Safety Information .................................................................5
Preparation ......................................................................6
Initial Installation ..................................................................7
Standard or Angle Mounting Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wiring .........................................................................11
Final Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Operating Instructions .............................................................15
Care and Maintenance ............................................................16
Troubleshooting ..................................................................16
Limited Lifetime Warranty ..........................................................18
Replacement Parts List ............................................................19
background
3
PACKAGE CONTENTS
PART DESCRIPTION QUANTITY
A Downrod 1
B Downrod Pin (preassembled to the Downrod [A]) 1
C Downrod Clip (preassembled to the Downrod [A]) 1
D Mounting Bracket (preassembled to Canopy [E]) 1
E Canopy 1
F Canopy Cover (preassembled to Canopy [E]) 1
G Yoke Cover 1
H Motor Assembly 1
I Set Screw (preassembled to the Motor Assembly [H]) 2
J Mounting Bracket Screw (preassembled to the Mounting Bracket [D]) 4
K Fitter Plate (preassembled to the Motor Assembly [H]) 1
L Fitter Plate Screw (preassembled to the Fitter Plate [K]) 3
M Light Pan 1
N Light Pan Screw (preassembled to the Light Pan [M]) 3
O Light Kit 1
P Bulb 2
Q Glass Bowl 1
R Blade 5
A
F
I
R
G
M
N
O QP
J
K
L
H
B
C
E
D
background
4
HARDWARE CONTENTS
Wire Connector
Qty. 3
+ 1 extra
Blade Screw
Qty. 15
+ 1 extra
Blade Washer
Qty. 15
+ 1 extra
Pull Chain Extension
Qty. 2
DD
(shown actual size)
AA BB CC
background
5
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the
product.
Before you begin installing the fan, disconnect the power by removing fuses or turning o󰀨 the circuit
breakers.
Make sure all electrical connections comply with local codes, ordinances, the National Electrical
Code and ANSI/NFPA 70-199. Hire a qualied electrician or consult a do-it-yourself wiring
handbook if you are unfamiliar with installing electrical wiring.
Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to
the oor and at least 30 in. from the end of the blades to any obstruction.
The net weight of this fan is: 16.49 lb (7.47 kg).
DANGER: When using an existing outlet box, make sure the outlet box is securely attached to
the building structure and can support the full weight of the fan. Failure to do this can result in serious
injury or death. The stability of the outlet box is essential in minimizing wobble and noise in the fan
after installation is complete.
WARNING: To avoid personal injury, the use of gloves may be necessary while handling fan
parts with sharp edges.
WARNING: Using a full-range dimmer switch to control fan speed will cause a loud humming
noise from the fan. To reduce the risk of re or electric shock, do NOT use this fan with any solid-state
speed control device.
WARNING: To reduce the risk of re, electric shock or personal injury, mount the fan to an outlet
box marked “ACCEPTABLE FOR FAN SUPPORT” and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for the support of lighting xtures are not acceptable
for fan support and may need to be replaced. Consult a qualied electrician if in doubt. Secure the
outlet box directly to the building structure. The outlet box and its support must be able to support the
moving weight of the fan (at least 35 lbs.).
WARNING: To reduce the risk of re, electric shock or personal injury, wire connectors provided
with this fan are designed to accept only one 12-gauge house wire and two lead wires from the fan. If
your house wire is larger than 12-gauge and/or there is more than one house wire to connect to the
two fan lead wires, consult an electrician for the proper size wire connectors to use.
WARNING: To reduce the risk of re, electric shock or personal injury, do not bend the blade
arms when installing them, balancing the blades or cleaning the fan. Do not insert objects between
the rotating fan blades.
WARNING: To reduce the risk of personal injury, use only parts provided with this fan. The use
of parts OTHER than those provided with this fan will void the warranty.
background
6
SAFETY INFORMATION
CAUTION: Read all instructions and safety information before installing your new fan. Review the
accompanying assembly diagrams.
CAUTION: Be sure the outlet box is properly grounded or that a ground (green or bare) wire is present.
CAUTION: Carefully check all screws, bolts and nuts on the fan motor assembly to ensure they are
secured.
CAUTION: This device complies with part 15 of FCC Rules. Operation is subject to the following
two conditions: 1) This device may cause harmful interference, and 2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment o󰀨 and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver
--Connect the equipment into an outlet on a circuit di󰀨erent from that to which the receiver is
connected.
--Consult the dealer or an experienced radio/TV technician for help.
Please note changes or modications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
HKC-US
3350 Players Club Parkway, Suite 225
Memphis, TN 38125
1-888-251-1003
PREPARATION
Before beginning the assembly of this product, ensure that all parts are present. Compare all parts
with the package contents list and hardware contents list. If any part is missing or damaged, do not
attempt to assemble the product.
Estimated Assembly Time: 120 minutes
Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety
Glasses, Step Ladder, Wire Cutters and Wire Strippers
Helpful Tools (not included): AC Tester Light, Tape Measure and Wiring Handbook
background
7
INITIAL INSTALLATION
1. Turn o󰀨 the circuit breakers and the wall switch to the
fan supply line leads.
DANGER: Failure to disconnect the power supply
prior to installation may result in serious injury or death.
2. Determine the mounting method to use.
Standard Mounting is best suited for ceilings 8 ft. or
higher. For taller ceilings you may want to use a longer
downrod (not included).
Angle Mounting is best suited for angled or vaulted
ceilings. A longer downrod is sometimes necessary to
ensure proper blade clearance.
Important: If using the angle mount, check to ensure
the ceiling angle is not steeper than 16°.
Flushmount is not available for this item.
Closemount is not available for this item.
Standard Mounting
Flushmount Closemount
Angle Mounting
3. Ensure the blades (R) will be at least 30 in. from any
obstructions. Also check the downrod (A) length to
ensure the blades (R) will be at least 7 ft. above the oor.
7 feet
minimum
30 in.
minimum
1
3
R
A
2
background
8
INITIAL INSTALLATION
4. Loosen all four preassembled mounting bracket
screws (J), then completely remove the two
mounting bracket screws (J) from the round holes
of canopy (E). Set aside for later use.
Detach mounting bracket (D) from canopy (E).
5. Attach mounting bracket (D) to outlet box (not
included) using screws and washers provided with
the outlet box.
CAUTION: It is very important to use the proper
hardware when installing the mounting bracket (D) as
this will support the fan.
4
D
Standard
Mounting
Angle
Mounting
5
D
D
E
D
J
D
background
9
STANDARD OR ANGLE MOUNTING INSTRUCTIONS
1. Remove the downrod clip (C) and downrod pin (B)
from the downrod (A). Then partially loosen the
set screws (I) in the yoke at the top of the motor
assembly (H).
2. Insert the downrod (A) through the canopy (E) and
yoke cover (G). Feed the wires from the motor
assembly (H) through the downrod (A).
3. Slide the downrod (A) into the yoke, align the holes,
then re-install the downrod pin (B) and downrod clip
(C). Secure with set screws (I) and slide the yoke
cover (G) down until it rests on top of the motor
assembly (H).
B
A
I
C
G
Yoke
2
3
A
G
E
Yoke
C
A
B
I
H
H
1
background
10
STANDARD OR ANGLE MOUNTING INSTRUCTIONS
4. Depending on the length of downrod you use, you
may need to cut the lead wires back to simplify the
wiring. If you decide to cut back the lead wires, it is
suggested you do so in the following manner: Take
the lead wires and make sure you have pulled them
all the way through the top of the downrod. Measure
8 inches of lead wire, then cut the excess wire o󰀨 with
wire cutters (not included).
5. If you decided to cut back the lead wire in Step 4, strip
1/2 in. of insulation from the end of the white wire.
Twist the stripped ends of each strand of wire within
the insulation with pliers (not included). Repeat the
step for the black and blue wires.
Note: If you did not cut back the lead wires in Step 4,
Step 5 is not necessary and you may proceed to Step
6 instead.
6. Install the ball end of the downrod (A) into the opening
of the mounting bracket (D). Align a slot in the ball
with the tab in the mounting bracket (D).
Important: The downrod (A) should not rotate in the
mounting bracket (D) if installed properly.
DANGER: Failure to align a slot in the ball with
the tab may cause the fan to wobble or fall, which
could result in serious injury or death.
5
A
D
Tab
Slot
6
4
8 in.
background
11
WIRING
WARNING: To reduce the risk of re, electrical shock or personal injury, wire connectors
provided with this fan are designed to accept only one 12-gauge house wire and two lead wires from
the fan. If your house wire is larger than 12-gauge and there is more than one house wire to connect
to the two fan lead wires, consult an electrician for the proper size wire connectors to use.
CAUTION: Be sure the outlet box is properly grounded or that a ground (green or bare) wire is present.
1. Connect household supply and fan wires according to
the diagram and these steps:
• Connect the Green wire from downrod (A) and
mounting bracket (D) to the Bare/Green supply wire.
• Connect the White wire from the fan to the White
supply wire.
• Connect the Blue and Black wires from the fan to the
Black supply wire.
• Secure all wiring connections together with wire
connectors (AA).
Note: If there is a second hot/power wire coming from
the outlet box, connect it to the Blue (light power) fan
wire for separate light and fan control.
Note: The Black wire is hot power for the fan. The
White wire is common for the fan and light kit. The
Green wire is the ground wire. If household supply
wires are di󰀨erent colors than referred to above, it is
recommended a professional electrician determines the
proper wiring.
Hardware Used
AA
Wire Connector x 3
2. Wrap electrical tape (not included) around each
individual wire connector (AA) down to the wire.
3. Turn the spliced/taped wires upward and gently push the
wires and wire connectors (AA) into the outlet box.
WARNING: Ensure no bare wire or wire strands
are visible after making connections. Place the Green
and White wire connections on the opposite side of the
outlet box from the Black wire connections.
1
3
AA
D
2
Black (hot)
White (neutral)
Bare/Green
(ground)
Black
Blue
White
Green
background
12
FINAL INSTALLATION
1. Align the canopy (E) over the loose mounting bracket
screws (J) preassembled on mounting bracket
(D). Place the keyholes of the canopy (E) onto the
mounting bracket screws (J) and rotate the canopy
(E) clockwise.
2. Secure the canopy (E) with the mounting bracket
screws (J) previously removed (Step 4, page 8).
Tighten all mounting bracket screws (J) securely.
3. Insert blade (R) through slot in the side of the motor
assembly (H). Align the holes of one blade (R) with
three blade screw holes in underside of the motor
assembly (H). Secure with three blade screws (BB)
and blade washers (CC). Repeat this step for the
remaining blades (R).
Hardware Used
BB
Blade Screw x 15
Blade Washer x 15
1
2
E
E
CC
BB
R
H
J
D
3
J
CC
background
13
FINAL INSTALLATION
4. Remove one and loosen the other two tter plate
screws (L) but do not remove from tter plate (K).
Feed the 9-pin connector through the center hole in
light pan (M). Align the two key slots in the light pan
(M) with the loosened tter plate screws (L). Place the
light pan (M) over the two screws and turn the light
pan (M) clockwise. Then tighten the two tter plate
screws (L). Re-install the previously removed tter
plate screw (L) and tighten rmly.
5. Remove one of the three light pan screws (N) and
loosen the other two screws from the underside of
light pan (M). Connect the 9-pin connector fan to the
9-pin connector from the light pan (M). Connect the
single-pin connector from the light pan (M) to the
single-pin connector from the light kit (O) -- blue to
blue and white to white. Align the two key slots in the
light kit (O) with the two previously loosened light pan
screws (N). Place the light kit (O) over the two screws
and turn the light kit (O) clockwise. Re-install the
previously removed light pan screw (N), and tighten
all three screws securely.
6. Install the bulbs (P) into the sockets of the light kit (O).
Important: Make sure you allow the bulbs (P) and
light kit (O) to cool before you replace the bulbs (P).
4
O
O
P
N
M
L
M
K
5
6
Single-pin
Connector
9-pin
Connector
9-pin
Connector
Keyhole
Slot
Keyhole
Slot
background
14
FINAL INSTALLATION
7. Attach the glass bowl (Q) to the light kit (O) by twisting
the glass bowl (Q) tightly in a clockwise direction until
it is secure. CAUTION: Avoid cross-threading the
glass during installation. Improper installation could
cause the glass bowl (Q) to be di󰀩cult to remove or
fall, which could cause serious injury.
8. Attach the pull chain extensions (DD) or custom pull
chain extensions (not included) to the fan and light
pull chains (if applicable).
Note: When facing the reverse switch, the light pull
chain is on the left and the fan pull chain is on the
right.
Hardware Used
DD
Pull Chain
Extension
x 2
9. Turn on the circuit breakers and the wall switch to the
fan supply line leads.
Assembly is complete.
8
9
7
O
Q
DD
Reverse Switch
background
15
OPERATING INSTRUCTIONS
1. The pull chain has four positions to control the fan
speed. One pull is high, two is medium, three is low,
and four turns the fan o󰀨. The light pull chain turns the
light on and o󰀨.
2. Using a ceiling fan will allow you to raise your
thermostat setting in summer and lower your
thermostat setting in winter without feeling a
di󰀨erence in your comfort.
In warmer weather, push the reverse switch left
to display a sun icon, which will result in downward
airow creating a wind chill e󰀨ect (Fig. 2a).
In cooler weather, push the reverse switch right to
display a snowake icon, which will result in upward
airow that can help move hot air o󰀨 the ceiling area
(Fig. 2b).
Important: The reverse switch must be set either
completely left or right in order for the fan to function
correctly. If the reverse switch is set in the middle
position, the fan will not operate (Fig. 2c).
Fig. 2a Fig. 2b
Fig. 2c
Reverse
Switch
1
2
Light Pull Chain Fan Pull Chain
background
16
CARE AND MAINTENANCE
At least twice each year, lower the canopy to check the downrod assembly, and then tighten all
screws on the fan. Clean the motor housing with only a soft brush or lint-free cloth to avoid scratching
the nish. Clean the blades with a lint-free cloth.
Bulb Replacement: Use 60-watt max. E26-base LED, CFL or incandescent bulbs. Halogen bulbs are
not recommended for this item.
Important: Shut o󰀨 the main power supply before you begin any maintenance tasks. Do not use
water or a damp cloth to clean the ceiling fan.
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan does not
move.
1. The power is o󰀨, or the fuse is
blown.
2. There is a faulty wire connection.
3. The plugs are not connected
properly.
4. The reverse switch is not
completely engaged.
1. Turn the power on or check the
fuse.
2. Turn the power o󰀨. Loosen the
canopy and check all connections.
3. Check that the connectors from
the light kit tter and fan are
connected properly.
4. Push the reverse switch
completely to the left or right.
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The wall control is not compatible
with the fan.
4. The outlet box is not secure.
5. The mounting bracket is not
secure.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer
switch to control the fan speed.
4. Ensure the outlet box is secured
to the building structure.
5. Ensure the mounting bracket is
secured to the outlet box and that
the screws are tight.
background
17
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
There is excessive
wobbling.
1. The blades and/or blade arms
are loose.
2. The blades are unbalanced.
3. The fan mounting is not
secure.
4. The fan is too close to the
vaulted ceiling.
5. The set screw on the motor
housing yoke is loose.
1. Check and tighten all screws that hold
the fan blades to the blade arms and
the blade arms to the motor.
2. Switch one blade with a blade from the
opposite side. Or balance the fan using
a blade balancing kit (sold separately).
3. Turn o󰀨 the power. Loosen the canopy
and verify that the mounting bracket
is secure to the electrical outlet box.
The bracket must be ush without
movement against the outlet box.
4. Use a longer downrod (sold separately)
or move the fan to another location.
5. Lift up the yoke cover and tighten the
set screw to the yoke until secure.
The fan operates
correctly, but the
lights are not
working.
1. The light kit wire plugs are not
connected properly.
2. There is a faulty wire
connection.
1. Ensure that the single-pin connectors
from the light kit are connected
properly.
2. Turn the power o󰀨 and check all
connections at the ceiling outlet box.
background
18
LIMITED LIFETIME WARRANTY
Set forth below, the manufacturer warrants the fan motor for this ceiling fan to be free from defects
in workmanship and material for the life of the product. Also, subject to the limitations below, the
manufacturer warrants all ceiling fan parts (“ceiling fan parts” excludes the motor and parts made in
whole or in part with glass) to be free from defects in workmanship and material for a period of one
year after the date of purchase by the original purchaser at retail.
All claims must be made by the original purchaser from an authorized dealer, whether such purchaser
purchased the product through a store or contractor. Ceiling fan part defects must be reported within
the rst year from the date of purchase. Parts made in whole or in part with glass and the nishes of
metal and other surfaces are not warranted.
Purchasers are responsible for all costs of removing and reinstalling the product. Any damage to any
part caused by ordinary wear and tear, accident, misuse, or improper installation, is not covered by
this warranty. The manufacturer assumes no responsibility whatsoever for fan installation. Any service
performed by a non-licensed electrician will render the warranty invalid.
The manufacturer’s sole responsibility shall be to repair or replace the motor, parts, or product within
the terms stated above. The manufacturer shall not be liable for any loss or damage of any kind,
including any incidental or consequential damages resulting directly or indirectly, from any breach
of warranty, express or implied, or any other failure of this product. Some states do not allow the
exclusion or limitation of incidental or consequential damages so this limitation may not apply to you.
If the original purchaser ceases to own the fan, this warranty is voided.
Should the purchaser encounter a problem with your fan related to defects in workmanship or
materials within the warranty period associated with the defective part, the manufacturer agrees to
replace the defective part without charge, or at its option, to replace the ceiling fan with a comparable
or superior model.
The manufacturer’s warranties are limited to the written warranties set out in this ceiling fan limited
lifetime warranty. All other express and implied warranties, including, without limitation, the implied
warranty of tness for a particular purpose and the implied warranty of merchantability is disclaimed.
Some states do not allow the disclaimer of implied warranties, so this disclaimer may not apply to you.
background
19
Printed in China
REPLACEMENT PARTS LIST
For replacement parts, call the customer service department at 888-251-1003, 8 a.m. - 8 p.m., EST,
Monday - Sunday. You could also contact us at [email protected].
PART DESCRIPTION #5497051 #5497052 #5497053 #5497054 COVERED
UNDER
WARRANTY
A Downrod 4A000020580 4A000020230 4A000025920 4A000025930 YES - 1 year
D Mounting Bracket 4L000014050 4L000011690 4L000014050 4L000014050
YES - 1 year
E Canopy 4L000015740 4L000017330 4L000017340 4L000017350 YES - 1 year
F Canopy Cover 4L000002190 4L000014240 4L000016140 4L000017360 YES - 1 year
G Yoke Cover 4A000009350 4A000008660 4A000021400 4A000025910 YES - 1 year
O Light Kit 4L000017370 4L000017370 4L000017370 4L000017370 YES - 1 year
Q Glass Bowl 4L167710001 4L167710001 4L167710001 4L167710001 NO
R Blade (x5) 4L086440001 4L086440002 4L086440001 4L086440003 YES - 1 year
HW Hardware Kit 4L000017260 4L000017270 4L000017280 4L000017290 NO
9923-PB • 061625
A D
E
F G
R
O
HW
Q

Specifications

Harbor Breeze 43013 Questions and Answers

Questions and Answers

Related Products