Firman P03611 Gas Portable Generator 4550W Recoil Start 120V

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents
  • P03611 Electrical Schematic - (English) Download
P03611 photo

P03611 User Manual English

This is the main product document for model P03611.

The file format is pdf, 35 pages, you can download this manual here .

background
OPERATOR'S
MANUAL
GASOLINE
PORTABLE
GENERATOR
MODEL
NUMBER
PD3611
Rev
Le
vel :00
Record
product
information
to
reference
when
ordering
parts
or
obtaining
warranty
coverage.
DO NOT RE1URN
TOSTOREI
Ji
I
CALL
US FIRST -
'I
1
1-844-347-62&1
"1.J
FOR QUESTIONS
OR
SERVICE INFORMATION
SERIAL NUMBER:
PURCHASE DATE:
P/N
:
336745460
Rev
:
06
background
Table
of
Contents
Introduction
...
....
. . . . . . . . . .
..
. . . . . . .
..
1
Trouble
Shooting
.
.. ..
, .
..
,
......
, .
. . 23
Safety
Precautions .
....
..
.
..
.. ..
.
..
.
. . . 2
Parts/
List/
Wiring
diagram
. .
....
.
24
. .
24
. 25
Unpacking
the
Generator.
Parts Included
..
Removal
Of
Shipping Supports .
Controls
and Features.
. .6
.
....
6
. . 7
. . 8
Generator
Parts Diagram .
Engine Parts Diagram
..
.
Parts
List.
. . . . . . . . . . . . . . . . . . . . 26
Wiring diagram
.......
. .
..
..
. , .. . . .
...
28
Generator. .
..
8
Service
Information
. . . .
..
. . . .
..
. . .
..
. . 29
Control Panel.
......
..
. .
..
. . . . , .
..
. . 9
Warranty
. .
Specifications . .
.....
. . . .
Add Engine
Oil.
.
..
10
. .
..
11
.
..
11
Low Oil
Shutdown.
Add Fuel . .
.......
. .
..
..
.
12
Operation
at
High Altitude
Grounding
..
.
.....
.
....
13
. .13
Operation.
.
..
. .
.......
. _ .
..
14
Generator
Location
..
. . . . .
..
. .
...
. . . . 14
Surge Protection . . . .14
Starting the Generator. . . .
15
Connecting Electrical
Loads.
. .
16
Stopping the
Engine.
.
16
Low Oil Shutdown
Do Not Overload Generator
..
.
17
. .
17
Maintenance
And Storage
..
. .
......
. ..
..
18
Maintenance Schedule . . .
.....
. .
...
18
Engine Maintenance . . . .
....
. .
...
..
19
Change Engine Oil . 19
Air
Filter
Maintenance..
. . .
..
19
Spark Plug Maintenance
..
.....
. . .
..
20
Clearing
Fuel
Strainer.
..
20
Inspect Muffler and Spark
Arrester
, . . 20
Generator
Maintenance .
Service and Storage .
English
. . .
..
21
.
..
22
. . 29
Cus
tomer
Service: 1-844-FIRMAN1
background
INTRODUCTION
Thank
you
for
purchasing a FIRMAN generator.
This
manual
contains safety information
to
make you aware
of
the
hazards and
risks
associated
with
generator products and h
ow
to
avoid. them. This generatpr is designed and intended
only
for
supplying electrical power
for
operating compatible electrical lighting, appliances, tools and
motor
loads, and
is
not
intended
for
any
other
purpose.
It
is
important
that
yoLI
read and
understand these instructions
thoroughly
before attempting
to
start
or
operate this equipment.
Save these
original
instructions
for
future
reference.
This manual covers operation and maintenance
of
the
FIRMAN generators. All information in this
publication is based on
the
latest production information available at
the
time
of
approval
for
printing.
The manufacturer reserves the
right
to
change, alter
or
other
wise improve the generator and
thi
s
dotu
mentation
at
any
time
without
prior
change.
1mpor1an1
sa1e1v1n1ormatmn
The manufacturer can
not
possibly anticipate every possible circumstance
that
might
involve a
hazard. The
wa
rnings in this manual and
the
tags and decals affixed
to
the
unit
are therefore
not
all-inclusive.
If
you
use a procedure,
work
method
or
operating technique that the manufacturer
does
not
specifically recommend you must satisfy yourself
that
it
is
safe
for
you and others. You
must
also make sure
that
the
procedure
work
method
or
operating
te
chnique
that
you
choose
does
not
render
the
generator unsafe.
Indicates a hazard
which,
if
not
avoided,
wi
ll result in death
or
serious injury.
Toxic Fumes
Fire Hazard
Hot
Surface.
Indicates a hazard
which,
if
not
avoided,
could result in death
or
serious injury.
Do
Not
Touch
the
Surface.
A
Kkkback
English
Pa
ge
01
Indicates a hazard
wh
ich,
if
not
avoided,
could result
in
minor
or
moderate injury.
Risk
of
Ele
ctric Shock
Explosion Hazard
Rotating Parts Entanglement
Hazard
Operator's Manual
Customer Servic
e:
1-844-FIRMAN 1
background
SAFOY
PRECAUTIONS
A
DANGER
Using
g
■n■
ralDr
Indoors CAN KILL
YOU
IN
MINIJTES
.
o-r
tor
exhaust
cont.Ins
cerbon monoxide.
1h11
Is
poison
you
cennot-or
m
U.
@
1€@
Li
~
NEVER
u■e
in
i•
home Only
UN
OIJTSIDE
and
or
praae,
EVEN
IF
daors
and
windowa
are
op
n.
far
away
from
windo,r,a,
doors,
and
venta.
Avoid
other
gan
r
tor
huarda.
READ MANUAL
BEFORE
USE.
A
DANGER
POISONOUS GAS HAZARD.
Engine exhaust contains carbon
monoxide, a poisonous
gas
that
could kill you in minutes.
You
CANNOT smell it,
see
it,
or
taste
it
.
Even
if
you
do
not
smell exhaust
fumes. you could still be exposed
to
carbon monoxide
gas.
Operate this product ONLY outside far away
from windows, doors and vents
to
reduce
the
risk
of
carbon
monoxide
gas
from
accumulating and potentially being drawn
towards occupied spaces.
Install battery-operated carbon monoxide
alarms
or
plug-in carbon monoxide alarms
with battery back-up according
to
the
manufacturer's instructions. Smoke alarms
cannot detect carbon monoxide gas.
DO NOT run this product inside homes,
garages, basements, crawlspaces,
sheds
,
or
other partially-enclosed
spaces
even
if
using
fans
or
opening doors and windows
for
ventilation. Carbon monoxide
can
quickly
build up
in
these
spaces
and
can
linger
for
hours,
even
after this product
has
shut
off
.
ALWAYS place this product downwind and
point
t he
engine
exhaust
away
from
occupied spaces.
If
you start
to
feel sick,
dizzy,
or
weak while using this product, shut
it
off
and
get
to
fresh air
RIGHT
AWAY.
See
a
doctor. You may have carbon monoxide
poisoning.
If
you
start
to
feel sick,
dizzy
or
weak
while using
the
portable generator, you
ma
y have
carbon
monoxide
poisoning.
Get
out
side
to
fresh air immediately and
call 911
for
emergency medical attention.
Very high levels
of
CO
can
rapidly cause
victims
to
lose consciousness before they
can
rescue themselves.
DO
NOT
attempt
to
shut
off
the
generator before moving
to
fresh air. Entering an enclosed space where
a generator is
or
has
been running
ma
y
put
you
at
greater risk
of
CO
poisoning.
E
ng
li
sh
Pa
ge
02
Cust
omer
Service 1-844-f 1RMAN1
background
CORRECT USAGE
Example location
to
reduce risk
of
carbon monoxide poisoning
O
NL
Y u
se
outs ide al'ld dowr1
wi
r1d
,
far
away
frorn
w il'ldows,
doors
al'ld
\"rnts
.
Dir
ect e
xh
aust aw
ay
tr
o
rn
occ
upied spaces.
INCORRECT
USAGE
Do
not
operate in
any
of
the
following
locations:
N
ea
r a
r1y
door, wi
r1d
ow or vel'lt
Garage
Base
rn
em
Crawl Space
Li
v
ir1
g
Ar
ea
Att
ic
ErmyWay
Pore
!'\
Mudroom
English
Page03
@)
mp
...
...........
._
CuS;tomer
Service:
1-844
-FIRMAN1
background
A
WARNING
Starter
cord
kickback
(rapid
retraction) will pull hand and arm
toward engine faster than you can
let
go
which could cause broken
bones,
fractures,
bruises,
or
sprains resulting in serious injury.
When starting engine, pull cord slowly until
resistance
is
felt and then pull rapidly
to
avoid kickback.
NEVER
start
or
stop
engine
with
electrical
devices
plugged
in
and
turned
on
.
&
WARNING
fuel
and
its
v
apors
are
extremely
flammable
and
explosive
w
hich
could
cause
burns
,
fire
,
or
explo
s
ion
resulting
in
death
or
serious
injur
y.
WHEN ADDING OR DRAINING
FUEL
Turn
generator
engine
OFF
and
let
it
cool
at
least 2
minutes
before
remo
v
ing
fuel
cap
.
Loosen cap slow
ly
to
relieve pressure in
tank
.
Fill
or
drain
fuel
tank
outdoors
.
DO
NOT
overfill
tank.
Allo
w space
for
fuel
expansion
.
If
fuel
spill
s, w
ait
until
it
ev
aporates
before
starting
engine.
Keep fuel away
from
sparks,
open
flames
,
pilot
lights,
heat,
and
other
ignition
sources.
Check
fuel
lines, tank, cap,
and
fittings
frequently
for
cracks
or
leaks. Replace
if
necessary.
DO
NOT
light
a
cigarette
or
smoke.
WHEN STARTING EQUIPMENT
Ensure
spark
plug
,
muffler
,
fuel
c
ap
, and
air
cleaner
are in place.
DO
NOT
crank
engine
with
spark
plug
remo
ved.
WHEN OPERATING EQUIPMENT
DO
NOT
operate this product inside any
building, carport, porch, mobile equipment,
marine applications,
or
enclosure.
DO
NOT
tip
engine
or
equipment
at
angle
w
hich
causes
fuel
to
spill.
DO
NOTstop
engine
by
moving
choke
c
ontrol
to
"Start"
position.
WHEN TRANSPORTING, MOVING
OR REPAIRING EQUIPMENT
Tr
ansport/move/repairwith
fuel
tank
EMPTY
or
with
fuel
shutoff
valve
OFF
.
DO
NOT
tip
engine
or
equipment
at
angle
w hich causes
fuel
to
s
pill.
Disc
onnect
spark
pl
ug wire.
WHEN
STORING
FUEL
OR
EQUIPMENT
WITH
FUELIN
TANK
Store away from furnaces, stoves, water
heaters, clothes dryers,
or
other
appliances
that
have
pilot
light
or
other
ignition
source
because they could
ignite
fuel vapors.
&
WARNING
This generator does not meet
U.
S.
Coast
Guard Regulation 33CFR-183 and should not
be used on marine applications.
Failure
to
use
the
appropriate U.S. Coast Guard
approved generator could result in death
or
serious injury.
&
WARNING
Generator
voltage
could
cause
electrical
shock
or
burn
res
ulting
in
death
or
serious
injury.
English
Page
04
Customer Service: 1-844-FIRMAN1
background
DO
NOT
touch
bare
w ires
or
receptacles.
DO
NOT
use
generator
with
electrical
cords
which
are
worn,
frayed,
bare
or
otherw
i
se
damaged.
DO
NOT
operate
generator
in
the
rain
or
wet
weather.
DO
NOT
handle
generator
or
electrical
cords
while
standing
in
wat
er,
while
barefoot,
or
whil
e
hands
or
feet
are
wet.
DO
NOT
allow
unqua
lified
persons
or
chi
ldren
to
operate
or
service
generator.
Lh
WARNING
Exhaust
heat/gases
could
ignite
combustibles,
structures
or
damage
fuel
tank
causing
a fire,
resu
lting
in
death
or
serio
us
injury.
Contact
with
muffler
area
cou
ld cause
burns
resulting
in
seriou.s
injury
.
e DO
NOTt
ouch
hot
parts
and
AVOID
hot
exhaust
gases.
Allowequipmenttocool
before
touching.
It
is
a
violat
ion
of
Ca
lifornia
Public Resource
Code, Section 4442,
to
use
or
operate
the
eng
ine
on
any
forest-covered,
bru
sh-covered,
or
grass-covered l
and
unless
the
exhaust
system is
equipped
with
a spa
rk
arrester,
as
defined
in
S
ection
444
2,
maintained
in
effective
work(
ng
order.
Other
st
ate
s
or
federal
jurisdictions
may
have
similar
laws.
Contact
the
original
equipment
manufacturer,
retailer,
or
dealer
to
obtain
a spa
rk
arrester
designed
for
the
exhaust system installed
on
th
is
engine.
Replacement parts
must
be
the
same
and
installed in
the
same
position
as
the
original
parts.
A
WARNING
Unintentional
sparking
co u Id cause
fire
or
electric shock resulting
1n
death
or
serious
injury.
WHEN
ADJUSTING OR
MAKING
REPAIRS
TO
YOUR
GENERATOR
Disconnect
the
spark
plug
wire
from
the
spark
plug
and
place
th
e
wire
where
it
cannot
contact
spark
plug.
WHEN
TESTING FOR ENGINE SPARK
Use
approved
s
park
plug
tester.
DO
NOT
check
for
spark
wit
h
spark
plug
removed
.
A
WARNING
Starter
and
other rotating
parts
could
entangle
hands,
hair,
clothing
,
or
accessories
resulting
in
serious
injury
,
NEVER
operate
gene
rat
or
without
protective
housing
or
covers.
DO
NOT
wear
l
oose
clothi
ng
,
je
wefry
or
anything
that
could
be
caught
in
the
starter
or
other
rotating
parts.
Tie
up
long
hair
and
remove
jewelry.
A
CAUTION
Excessively high operating speeds could result
in
minor
injury
. Excessively low operating speeds
imp
ose a heavy load.
DO
NOT tamper with governor spring, links
or
other parts to increase engine speed.
Generator
supplies
correct
rated
frequency
and
voltage
when
running
at
governed
speed
.
DO
NOT
modify
generator
in
any
way
.
NOTE:
Exceeding generators
wattage/amperage
capacity
could
damage
generator
and/or
electrical devices
connected
to
it.
DO
NOT
exceed t
he
generator's
wattage
amperage
capacity.
Start
generator
and
let
engine
stab
ilize
before
connecting
electrical
loads.
Co
nn
ect
electrical
l
oads
in
OFF
position,
then
turn
ON
for
operation.
T
urn
electrical
loads
OFF
and
disconnect
from
generator
before
stopping
genera
t
or
.
English
Page
05
Customer Service: 1-844-FIRMAN1
background
NOTI:
I f Id d
1.
Engine
Oil(Bottle)
.....
.
..
....
...
.
.....
..
1
mproper
treatment
o
generator
cou
amage
it
and
shorten
its
life.
2
-
Oil
Funnel···
•• - - -- --
.1
Use
generator
only
for
intended
uses.
Jfyou
have
questions
about
inte
nded
use,
ask
dealer
or
contact
local
service
center.
Operate
generator
only
on
level
surfaces.
DO
NOT
expose
generator
to
excessive
moi.sture,
dust,
dirt
,
or
corrosive
vapors.
DO
NOT
insert
any
objects
through
cooling
slots.
If
connected
devices
overheat,
turn
them
off
and
disconnect
them
from
generator
.
Shutoff
generator
if:
-Electrical
output
is
lost.
-Equipment
sparks, smokes,
or
emits
flames
.
-Un
it
vi
brat
es
excessively
.
A
WARNING
Medical
and
Life
Support
Uses.
In
case
of
emergency,
call
911
immediately.
NEVER use
this
product
to
power
life
support
devices
or
life
support
appliances.
NEVER use
this
product
to
power
medical
devices
or
medical
appliances.
Inform
your
electricity
provider
immediately
if
you
or
anyone
in
your
household
depends
on
electrical
equipment
to
live.
Inform
your
electrical
provider
immediately
tf
a loss
of
power
wou
ld cause
you
or
anyone
in
your
household
to
experience
a
medical
emergency
.
UNPACKING
THE
GENERATOR
Open
carton
and
Remove
packaging
materials
.
Remove
generator,
accessorles
boxes,
and
literature
from
carton.
If
any
items
are
missing
or
damaged, contact our product
service
department at l-844-347-6261.
Pans
lncludud
Your
gasoline
powered
generator
ships
with
the
following
parts:
3.
Wrench
for
Spark
plug
.........
...
. .
..
...
. 1
4.
Double
Open
wrench
(10mm
&
12mm)
..
, . 2
5.
Manual.
.................................
1
6.
Quick
Reference
Guide
.
...
.
..
. .
...
.
..
...
. 1
2
3
t
Manual
/I
5
Quick
Reference
Guide
6
English
Pa
ge 06
Customer Service: 1-844-FIRMAN1
background
REMOVAL
OF
SHIPPING
SUPPORTS
Before
you
can
run
your
new
generator,
follow
these
sim
ple
instructions:
The following Items must
be
removed before
running your new generator.
In
order
to
protect
your
generator these items have been added
to
ensure safe delivery
of
your new generator,
A
CAUTION
Failure
to
remove
these
items
can
result
in
damage
to
your
generator,
possible
Personal
injury
and
void
your
warranty
.
Refer
to
the
following
instructions
and pictures
to
remove the attached
engine
support
brackets
(red)
under
the
engine.
1.
Before
filling the
engine
oil, tip the generator
back
onto
its
recoil
frame
end
as
indicated
in
this
picture.
Place
the generator
on
the flattened
cardboard
box
or
other protective
surface.
2.
Remove
the indicated
bolts
and
nuts
from
the
red
engine support
brackets.
You
may
use
the
appropriate
wrenches
provided.
3.
You
rnay
discard
these
brackets,
as
they
are
no longer
required for normal operation
of
yourgenerator.
Your
generator
is
now
ready
for
use. Refer
to
your
owner's
manual
for
proper
oil
fill
and
startu
p
instructions.
Supp
lied wrenches
Engine
Support
Brackets
(red
color)
Remove
these
4
nuts
&
bolts
as
indicated.
English
Page
07
Customer
Service
: 1-844-FIRMAN1
background
CONTROLS
AND
FEATURES
Genera1or
1-
FuelGauge
2-
5.0
Gallon(19L) Capacity Fuel
Tank
3-FuelCap
4-
· Choke Lever
5-
Fuel Valve
6-
Air
Filter
7-
· 208cc
FIRMAN
OHV
Engine
8-
Recoil
Starter
9-
Bottle
Opener
10
-
Oil
Filler
Cap
11
-
Outlet
Cover
12
-
Control
Panel
13
-
Data
Decal
*We
are
alwa
ys
working
to
impro
ve
our
products.
Therefore,
the
enc
l
osed
product
may
differ
slightly
from
the
image
on
this
page
.
English
Page 08
Cust
omer
Se rvlce: 1-844-F IRMAN 1
background
Con1ro1
Panel
0
NOTE:
@
Total
power
drawn
from
all
receptacles
must
not
exceed
the
name
plate
rating
.
0 Engine
Switch-
Flip
the
switch
to
the
''
ON
"(
I)
position and
pull
the
recoil starter
to
start
the
generator. Turn
to
the
"OFF"(O) position
to
turn
off
the
generator
.
8
4-1
Data-Minder(Multi-Meter)
- Push
the
SELECT
button
to
show
the
Voltage, Hertz and
running hours.
If
the
l
ow
oil
indicator
is
lit,
check
the
oil level.
A
B
C D E
A -
Digital
display
D - H
our
indicator
B
-AC
voltage
indicator
E -
Low
oil
indicator
C -
Frequency
indicator
F - Select
button
@)
120V,
30A
RV (NEMA TT-30R)
Maximum
full
load
30
Amp
current
may
be
drawn
from
this
120
Volt
receptacle.
8
Ground
Terminal-
Consult
an
electrician
for
local
gro
undin
g
regulations.
0
120V,
20A
Duplex
- (NEMA 5-20R) 20
Amp
of
current
may
be
drawn
from
this
120
Volt
receptacle.
0 Circuit Breakers - The receptacles are
protected by
an
AC
circuit protector.
If
the
generator
is
overloaded
or
an
external short
circuit occurs the circuit protector will
trip
.
If
this occurs, disconnect all electrical loads
and
try
to
determine
the
cause
of
the
problem
before
attempting
to
use
the
generator again.
If
overloading
causes
the
circuit protector
to
trip, reduce
the
load.
Note: Continuous tripping
of
the circuit
protector may
cause
damage
to
generator
or
equipment.
The
circuit protector may be
reset
by
pushing
the
button
of the
protector
.
fl
120V,
30A
Twist
Lock (NEMA L5-30R)
Maximum
full
load 30
Amp
current
may
be
drawn
from
this 120
Volt
receptacle.
@
Outlet
Cover
-
Prote
ct
the
receptacles
from
dust
and
debris
.
English
Page 09
C
ustomer
Service
1-844-fIRMAN1
background
SPECIFICATIONS
Model
P03611
Starting Watts
4550
Running Watts
3650
Rated
AC
Voltage 120V
Rated
Feq
uency 60Hz
Phase
Single
Voltage Regulator
AVR
Power Factor
1
Total Harmonic Distortion(THD)
25%
Alternator Type
Brushed
Engine
FIRMAN
Engine Type
Single Cylinder; 4-Stroke OHV Air Cooled
Displacement
208cc
Low Oil Shutdown
Yes
Ignition System
Breakless Ignition Type, Flywheel Magneto
Starting System Recoil
Fuel
Unleaded Automotive Gasoline
Capacity
Fuel
Tank
5.0
Gallon(19L)
Lubricating Oil Capacity
20.3 oz(0.6L)
Carburetor Type
Float
Air Cleaner Polyurethane Type
P.T.O.
Shaft Rotation
Counter Clockwise
(Facing
P.T.O.)
Oil Tvoe
See
"Add Enoine Oil" Section
AC
Grounding System
Neutral
Floating
" This
generator
is
rated
in
accordance
with
CSA
(Canad ian
Standards
Association)
standard
C22.2
No
.
100-14.
AN
IMPORTANT
MESSAGE
ABOUT
TEMPERATURE:
Your Firman Po
wer
Equipment
product
is
designed and rated
for
continuous
operation
at
ambient
temperatures
up
to
104°F (40°C). The
generator
may be operated
at
temperatures
ranging
from
S°F(-15°C)
to
122°F(50°C)
for
short
periods.
If
the
generator
is
exposed
to
temperatures
outside
this
range
dur
ing storage,
the
generator
should be
brought
back
with
in
this
range before
operation.
When
operated
above 77°F(25°C)
there
may
be
a decrease in power. Maxim urn
wattage
and current
are
subject
to
and
limited
by
such factors
as
ambient
temperature, a ltitUde,
engine
conditions
etc.
E
ng
li
sh
Pagel
O
Customer Service: 1-844-FIRMAN1
background
Add
Engine
Oil
NOTICE
DO
NOT
attempt
to
crank
or
start
the
engine
before
it
has
been properly filled with
the
recommended type and amount
of
oil. Damage
to
the
generator
as
a result
of
failure
to
follow
these instructions will void your warranty.
NOTE:
The
recommended
oil
type
is
l0W-30 automotive
oil.
However
outdoor
temperatures
will
determine
the
space
proper
oil
viscosity
for
the
engine.
Use
the
chart
to
select
the
best
for
the outdoor
temperature
range
expected.
Degrees
Cels1us
0
{0uts1de)
-21.1 -17.8 -C.7
4.4
15.6 26.7
37.11
411.9
1
fii
IMIINIMf
I
1
M
MW
:
I
IEE
I
Ju
~
~
~D
rla
~
l~D
do
Degrees Fahrenhe1t
0
(0uts1de)
1.Place
generator
on
a flat, l
evel
sur
fa
ce.
2.Clean area
around
oil
fill
and
remove
yellow
oil
fill
cap
/dipst
ick
.
3.Wipe
dipstick
clean.
UPPER]
UNII'
(H)
-
-
I..O'll'ER
UMIT (L)
4.Using
oil
funnel,
slowly
pour
contents
of
provided
oil
bottle
into
oil
fill
opening
to
the
''H''
mark
on
dipstick.
Be
careful
do
not
overfi
ll.
Overfilling
w
ith
oil
could
cause
the
engine
to
not
start
or
hard
starting.
5.Replace
oil
fill
cap/dipst
ick
and
fully
tighten.
6Dil
le
ve
l
should
be checked
prior
to
each use
or
at
least
every
8
hours
of
operation.
Keep
oil
level
maintained.
The engine
is
equipped
with
a
low
oil
shut-off
and
will s
top
when
the
oil
level in
the
crankcase falls
below
the
threshold
le
ve
l.
NOll:
We consider
the
first 5 hours
of
run
time
to
be
the break-in
period
for
the unit. During the break
in period stay
at
or
below
50%
of
the
running
watt
rating and vary
the
load occasionally
to
allow
stator windings
to
heat and cool. Adjusting
the
load will also cause engine speed
to
va
ry
and help
seat piston rings.
low
oil
shuldown
The
unit
is
equipped with a low oil shutdown.If
the oil level becomes lower than required,the
sensor will activate a warning device
or
stop the
engine.
If
generator shuts
off
and the oil level
is
within
specifications, check
to
see
if
generator is sitting
at
an
angle
that
forces oil
to
shift.
Place
on
an
even surface
to
correct this.
If
engine fails
to
start, the oil level may
not
be sufficient
to
deactivate low oil level switch. Make sure the
sump is completely full
of
oil.
English
Page
11
Customer
Service: 1-844-FIRMAN1
background
Add
Fuel
Fuel
must
meet
these
requirements
:
Clean, fresh,
unleaded
gasoline
.
Use
regular
UNLEADED
gasolinewith
the
generator
engine
with
a
minimum
87
octane
/
87
AKI (91 RON).
For
high
altitude
use, see
"Operation
at
High
Altitude"
.
Do
not
use
gasoline
with
more
than
10%
ethanol
such
as
E85
or
ethanol.
lffl:
Avoid
generator
damage.
failure
to
follow
Operator
's
Manual
for
fuel
recommendations
voids
warranty
.
DO NOT use unapproved gasoline such
as
E85.
DO
NOT mix oil in gasoline.
DO NOT
modify
engine
to
run on alternate fuels.
A
WARNING
&
Fuel
and
its
vapors
are
extremely
flammable
and
explosive
which
could
cause
burns,
fire
or
explosion
resulting
in
death
,
serious
injury
.
WHEN
ADDING
FUEL
A
CAUTION
Slowly add unleaded gasoline
to
fuel
tank
.
Do
not
overfill
tank.
Do
not
fill above
the
red line
indicator
.
This will
allow
expansion in
hot
w
eather
and
prevent
overflow.
Fill
fuel
tank
outdoors.
IMPORTANT:
It
is
important
to
prevent
gum
A
DO
NOT
overfill
tank.
Allow
space
for
fuel
deposits
from
forming in fuel system parts such
~
expansion.
If
the
tank
is
overfil
le
d,
fuel
as
the
carburetor, fuel hose
or
tank
during storage.
can
overflow
onto
a
hot
engine
and
cause
fire
Alcohol-blended fuels (called gasohol, ethanol
or
explosion.
Wipe
up
any
spilled
fuel
or
methanol)
can
attract moisture, which leads
to
immediately.
separation and formation
of
acids during storage.
If
fuel spills,
wait
unti
I
it
evaporates
before
Acidic gas can damage
the
fuel system
of
an
engine
starting
engine.
while in storage. To avoid engine problems, the
Keep
fuel
away
from
sparks,
open
flames, fuel system should be emptied before storage
of
pilot
lights,
heat,
and
other
ignition
sources. 30 days
or
longer.
See
the
" Long Term Storage"
Check
fuel lines,
tank,
cap
and
fittings
section.
Never
use engine
or
carburetor cleaner
frequently
for
cracks
or
leaks. Replace
if
products
1n
the
fuel
tank
as
permanent damage
necessary.
A
DO
NOT
light
a
cigarette
or
smoke
when
~
filling
the
fuel
tank.
1.Clean
area
around
fuel
fill
cap,
remove
c
ap.
2.Slowly
add
unleaded
fuel
to
fuel
tank.
Be
careful
notto
fill
above
the
red fuel
level
indicator.
This
allows
adequate
space
for
fuel
expansion.
3.Install
fuel
cap
and
let
any
spilled
fuel
ev
aporate
before
starting
engine
or
wipe
up
any
spilled
gasoline.
may occur.
English
Page·12
Custom
er
Service: 1-844-FIRM
AN1
background
Operation
at
High
Altitude
At
altitudes
over
5,000
feet(l524
meters), a
minimum
85
octane
gasoline
is
acceptable.
Engine
power
and
generator
output
will
be
reduced
approximately
3.5%
for
every
1000
feet (305 m)
of
elevation
above
sea level.
High
altitude
may
cause hard
starting
, increased
fuel
consumption
and spark
plug
fouling
. To
operate
at
high
altitudes
FIRMAN can
provide
a
high
altitude
carburetor
main
jet.
The
alternative
main
jet
and
installation
instructions
can be
obtained
by
contacting
Customer
Support.
208cc
Altitude
335717002
3000-6000Feet
Altitude
main
jet
1
(914-1828
m)
Altitude
mainjet2
335717003
6000-B000Feet
(1828-2438m)
NOTICE
Operation
using
an
alternative
main
jet
at
elevations
lower
than
the
recommended
minimum
altitude
can
damage
the
engine.
For
operation
at
lower
elevations,
the
standard
main
jet
supplied
must
be used.
Operating
the
engine
with
the
wro
ng
main
jet
ma
y increase
exhaust
emissions,
fuel
consumption
and
reduce
performa
nee.
Grounding
The
generator
neutral
is
floating
,
wh
ich means
that
the
AC
stator
winding
is
isolated
from
the
grounding
fastener
and
the
AC r
eceptac
le
ground
pins. On a
floating
neutral
generator
the
AC receptacle
ground
pins are
not
functional.
Ele
ct
rical devices, such
as
a
ground
fault
circu
it
interrupter
(GFCI),
requiring
a
functioning
AC
receptacle
ground
pin
w
ill
not
operate
.
.&
WARNING
&
Generator
vo
ltage
could
cause
electrical
shock
or
bum
resulting
in
death
or
serious
inJury.
DO NOT
touch
bare w ires
or
receptacles.
e DO NOT use
generator
with
electrical cords
which are
worn
,frayed, bare
or
otherwise
damaged.
DO NOT
operate
generator
in
the
rain
or
wet
weather.
e DO NOT
handle
generator
or
electrical cords
w
hile
standing
in w
ater
,
wh
ile
barefoot
,
or
wh
ile hands
or
feet are wet.
DO NOT
allow
unqualified
persons
or
children
to
operate
or
s
er
vice
generator.
Eng
li
sh
Page·B
Customer
Service
: 1-844-FIRMAN1
background
OPERATION
Generator
localion
&
WARNING
Make sure
you
review each warning in order
to
prevent fire hazard.
Keep area clear
of
inflammables
or
other
hazardous materials.
Select a site
that
is
dry, well
vent
ilated and
protected from
the
weather.
Keep exhaust pipe clear
of
foreign objects.
Keep generator away from open flame.
Keep generator on a stable and level surfa
ce.
&
CAUTION
Tilting
can cause fuel
spillage
_
(I;
Do
not
block
generator air vents
with
paper
or
other
material.
A DANGER
U.ing
a
gan■
ra!Dr
Indoors CAN KILL
YOU
IN
MINUTES.
G-rator
eixhltuat contalna carbon monoxide.
Thi•
la
poleonyou
cannot-oramell,
©~
Li
~
NEVER
UH
Inside.
home Only
u•
OUTSIDE
and
or
prqe,
EVEN
IF
door
far---,
from
wlndowa,
and wlndowa
re
open.
doors. and vanta.
Avoid
oth
r
generator hazards.
READ MANUAL BEFORE
USE.
POISONOUS
GAS
HAZARD.
Engine exhaust contains carbon
monoxide, a poisonous
gas
that
could kill you in minutes,
You
CANNOT smell it,
see
it,
or
taste
it.
Even
if
you
do
not
smell exhaust
fumes, you could still be exposed
to
carbon monoxide
gas.
Operate this product ONLY outside far away
from windows, doors and vents
to
reduce
the
risk
of
carbon
monoxide
gas
from
accumulating and potentially being drawn
towards occupied spaces.
Install battery-operated carbon monoxide
alarms
or
plug-in carbon monoxide alarms
with
battery
back-up according
to
the
manufacturer's instructions. Smoke alarms
cannot detect carbon monoxide gas.
DO
NOT
run this product inside homes,
garages, basements, crawlspaces, sheds,
or
other partia Uy-enclosed
spaces
even
if
using
fans
or
opening doors and windows
for
ventilation. Carbon monoxide
can
quickly
build
up
in these
spaces
and
can
linger for
hours,
even
after this product
has
shut off.
ALWAYS place this product downwind and
point
the
engine
exhaust
away
from
occupied spaces.
[f
you start
to
feel sick,
dizzy,
or
weak while using this product, shut
it
off
and
get
to
fresh air
RIGHT
AWAY.
See
a
doctor
.
You
may have carbon monoxide
poisoning.
Surge
ProlBclion
NOTICE:
Voltage
fluctuation
may
impair
the
proper
functioning
of
sensitive
electronic
equipment
.
Electronic devices, including computers and
many programmable appliances
use
components
that are designed
to
operate within a narrow
voltage range
and
may
be
affected by momentary
voltage fluctuations. While there
is
no way
to
prevent voltage fluctuations, you
can
take steps
to
protect sensitive electronic equipment.
[nstall
UL1449, CSA-listed,
plug-in
surge
suppressors
on
the
outlets
feeding
your
sensitive equipment. Surge suppressors come
in
single-
or
multi-outlet
styles. They're
designed
to
protect
against
virtually
all
short-duration
voltage fluctuations.
En
glish
Page
14
C
ustomer
Service 1-844-FIRMAN1
background
Starling
thB
G1n1rator
1.
Before
starting
the
generator
,
check
for
loose
or
missing
parts
and
for
any
damage
which
may
have
occurred
during
shipment.
2.
Check
oil
level
and
fuel.
3.
Disconnect
all
electrical
loads
from
the
generator.
Never
start
or
stop
the
generator
with
electrical
devices
plugged
in
or
turned
Oil.
4.
Turn
the
fuel
valve
to
the
"ON" (
!)position
.
7. Pull
the
starter
cord
s
lo
w ly
Until
resistan
ce is
felt
and
then
pull
rapidly.
8.
Do
not
over-choke.
As
soon
as
engine
star
ts
and
warms
up
,
move
the
choke
lever
to
the
"
RUN
"
position.
-------
9.
Allow
generator
to
run
at
no
load
for
a
few
minutes
upon
each
initial
start-up
to
permit
engine
and
generator
to
stablize.
A
WARNING
&
Starter
cord
kickback(rapid
retraction)
will
pull
hand
and
arm
toward
engine
faster
than
you
can
let
go
which
could
cause
broken
bones,
fractures,
bruises,
or
sprains
resulting
in serious injury_
When
starting
engine,
pull
cord
sl
ow
ly
until
resistance
is
felt
and
then
pull
rapidly
to
avoi
d
5.
Flip
the
engine
switch
to
the
"
ON
"(
I)
position.
kickback.
6.
Move
the
choke
lever
to
the
"START"
position
.
Start
IRE:
Keep
choke
lever
in
"
START
"
position
for
only
1
pull
of
the
recoil
starter.
After
first
pull
,
move
choke
lever
to
the
"RUN"
position
for
up
to
the
next
3
pulls
of
the
recoil
starter.
Too
much
choke
leads
to
spark
plug
fouling/engine
flooding
due
to
the
lack
of
incoming
air
. This
will
cause
the
engine
not
to
start
.
1111:
If
engine starts
after
3 pulls
but
fails
to
run,
or
if
unit shuts down during operation,
make
sure
unit
is
on
a level surface and check for
proper
oil
level
in
crankcase.
This
unit
may
be
equipped
with
a
low
oil protection
device
.
If
so,
oil
must
be
at proper
level
for
engine
to
start.
En
glish
Page
15
Customer
Service 1-844-FIRMAN1
background
Connecling
Electrical
loads
This
unit
has
been
pretested
and
adjusted
to
handle
its
full
capacity.
Before
starting
the
generator,
disconnect
all
load.
Apply
load
only
after
generator
is
running.
Voltage
is
regulated
via
the
engine
speed
adjusted
at
the
fac
tory
for
correct
output.
Readjusting
will
void
warranty.
NOTICE
When applying a load,
do
not
exceed
the
maximum
wattage rating
of
the generator when using
one
or
more
receptacles. Also,
do
not
exceed
the
amperage
rating
of
any one receptacle.
Do
not
apply heavy electrical load during break-in
period (the first five hours
of
operations).
1.Let
engine
stabilize
and
warm
up
for
a few
minutes
after
starting.
2.Ensure
circuit
breaker
on
control
panel
is
in
on
position.
3. Plug
in
and
turn
on
the
desired
120
volt
Ac,
single
phase
,
60hz
electrical
loads.
It
is
better
to
attach
the
item
with
lar
gest
load
first.
Slopping
lhe
Engine
1. Turn
off
and remove entire electrical loads.
Never start
or
stop
the
generator with
electrical devices plugged in or turned on.
Let
the
generator
run
at
no-load
for
two
minutes
to
stabilize
internal
temperatures
of
the
engine
and
generator
.
2.
Press
the
engine switch
to
the
"O
FF
"(O) position.
Do
not
leave
the
generator
until
it has
completely
stopped.
3.
Turn
the
fuel
valve
to
the
"OFF"(O
)
position.
If
a cover
is
used,
do
not
install until unit
has
cooled.
A
WARNING
Fuel
and
its
vapors
are
extremely
flammable
and
explosive
which
could
cause burns,
fire
or
explosion
resulting
in
death
or
seriou
s
injury.
English
Pa
ge 16
C
ustomer
Service 1-844-f1RMAN1
background
DO
NOT
stop
engine
by
moving
choke
control
to
"ST ART"
position
.
Important:
Always
ensure
that
the
Fuel
Val
ve
and
the
Engine
Sw
it
ch are
in
the
"OFF" po
sition
when
the
engine
is
not
in
use
.
lffl:
If
the
engine
will
not
be
used
fora
period
of
two
Do
Nol
overload
Generator
Overloading
a
generator
in
excess
of
its
rated
wattage
capacity
can
result
in
damage
to
the
generator
and
to
c
onnected
ele
c
tri
c
al
.
devices
.
To
prolong
the
l_ife
of
you
r
generator
and
atta
c
he
d
de
vices,
follo
w the.se
steps
to
add
electrical
load:
weeks
or
lo
nger
,
please
see
the
Storage
section
1.
Start
the
generator
w
ith
no
electrical
load
for
proper
engine
and
fuel
storage.
atta
c
hed.
low
Iii
Shutdown
If
the
engine
oil
drops
below
a
preset
level
, an
oil
switch
will
stop
the
engine
. Check
oil
le
vel
with
dipstick.
If
oil
le
v
el
is
between
LOW
and
HIGH
mark
on
dipstick:
l.DO
NOT
try
to
restart
the
engine.
2.
Contact
an
Authorized
FIRMAN Service Dealer.
3.
DO
NOT
operate
engine
until
oil
level
is
corrected.
If
oil
le
vel
is
below
LOW
mark
on
dipstick
:
1.Add
oil
to
bring
level
to
HIGH
mark.
2.Restart
engine
and
if
the
engine
stops
ag
ain
a
low
o
il
co
nditi
on
may
still
exist.
DO
NOT
try
to
res
ta
rt
the
engine
.
3.Contact
an
Authorized
FIRMAN
Ser
v
ice
Dealer
.
4.
DO
NOT
operate
engine
until
oil
lev
el
is
co
rre
c
ted
.
2.
Allow
the
engine
to
run
for
s
everal
minutes
to
stab
i
lize.
3. Plug in
and
turn
on
the
firs
t i.tem.
It
is
best
t o
attach
the
item
with
the
largest
load
firs
t.
4.
Allow
the
engine
to
stabilize
.
5.
PI\Jg
in
and
turn
on
the
next
item.
6.
Allow
the
engine
to
stabilize.
7.
Repeat
steps
5-6
for
each
additional
item
.
English
Pa
ge
17
Customer Service: 1-844-FIRMAN1
background
MAINTENANCE
AND
STORAGE
MAINTENANCE
SCH
ED
UH
1,
Daiy(Befa-e
Initial
Every
Every
Every
ITEM
NOTES
100 hour.;
operation)
25 hours
50
hours
(or
annual}
250hour.;
Spark
Plug
Check
condition.
Adjust
gap
.J
and
clean
. Replace
if
necessary.
Check
oil
le
ve
l. ./
Engine
Oil
Replace. ./
./
Air
Filter
Clean,
replace
if
necessary.
./
Fuel
Filter
Clean
fuel
filter
and
fuel
tank
strainer.
Replace
if
necessary.
.J
Fuel
Line
Check fuel hose
for
cracks
or
other
damage. Replace
if
necessary.
,I
Check
for
leakage.
Retighten
or
./
Ex
haust
replace
gasket
if
necessary
,
Syst
em
Check
spark
ar
r
ester
screen.
./
Clean/Replace
if
necessary.
C
he
ck
adjust
v
alve
clearance
.*
./
Engine
Clean
combust
ion
chamber.*
.J
Fittings/
Check.
Replace
if
necessary.
Fasteners
•Tobe
performed
by
knowledgable
/
experienced
owner
or
by
auth
or
ized
service
ce
nter
.
Ganaral
Racommandalions
Regular
maintenance
will
imp
rove
the
performance
and
extend
tfie
life
of
the
generator
. See any
authorized
dealer
for
service.
The
generator
's
warrant
y
does
not
cov
er
items
that
have
been
subjected
to
operator
abuse
or
negligence
.
To
rec
ei
ve full val
ue
from
the
warranty
:
the
operator
must
maintain
the
generator
as
instructed
in
this
·
manual.
Some
adjustments
will
need
to
be
made
periodically
to
properly
maintain
yo
ur
generator
.
All
service
and
ad
justments
should
be
made
at
least
once
each season. Fo
llow
the
requirements
in
the
Maintenanc
Shedule
chart
above
.
Notice
Once
a
year
you
should
clean
or
replace
the
spark
plug
and
replace
the
air
filter
.
New
spark
plugs
and
clean
air
filter
assure
proper
fuel-air
mixture
and
help
your
engine
run
better
and
last
longer.
English
Page
18
Customer Service: 1-844-FIRMAN1
background
ENGINE
MAINTENANCE
To
prevent
accidental
starting,
remove
and
ground
spark
plug
wire
before
performing
an
y
service.
Change
Engine
Oil
Change
engine
oil
every
100
hours
.
(for
a
new
engine,
c
hange
oil
after
25 hours.)
If
you
are
using
your
generator
under
extremely
dirty
or
dusty
conditions,
or
in
extremely
hot
weather,
change
the
oil
more
often.
.&.
CAUTION
Avoid
prolonged
or
repeated
skin
contact
wi
th
used
motor
o
ii.
Used
motor
oil
has
been
shown
to
cause skin
cancer
in
certain
laboratory
animals.
Thoroughly
wash
exposed
areas w
ith
soap
and
water
.
(a)
Drain
oil
by
removing
the
drain
plug
and
the
oil
filler
cap
while
the
engine
is
warm.
NOTE:
Please
use
an
appro
v
ed
container
to
catch
and
recyc le
the
used
oi
I.
(b)
Reinstall
the
drain
plug
and
fill
the
engine
with
oil
until
it
reaches
the
HIGH(H)
le
ve
l
on
the
oil
filler
c
ap.
Use
fresh and high
quality
lubricating oil
to
the
sp
ecified
quantity
.
If contaminated
or
deteriorated oil is used
or
the
quantity
of
the
engine
oil
is
not
sufficient,
engine damage will result and its life will be
greatly shortened.
Air
Filler
Maintenance
Maintaining
an
air
filter
in
proper
condition
is
very
important
.
Dirt
induced
through
improperl
y
installed,
improperly
serviced,
or
inadequate
elements
damages and wears
out
engines.
Always
keep
the
element
clean .
(a)
Take
out
the
ai r cleaner, clean
it
well
in
kerosene
and
dry
i
t.
AIR
CLEANER
COVER
CUP
CUP
AIR
FILTER
ELEMENT
8J
(b)
After
w
etting
the
element
with
clean
engine
oil
squeeze
ittight
by
hand.
(c)
Lastly
,
putt
he
element
in
the
case
and
i
ns
tall
it
securely.
English
Page
19
Customer Service: 1-844-FIRMAN1
background
Spark
Plug
Main
t
enance
Changing
the
spark
plug
w
ill
help
your
engine
to
start
easier
and
run
better.
(a)
Remove
the
spark
plug cap.
(b) Remove
spark
pl
ug
using
provided
w
ri:n
ch.
A-
Spark p l
ug
B-
Spark
plug
cap
(c
)
In
s
pe
ct
spark
plug
for
damage
and cl
ean
w
ith
a
wire
brush
before
reins
ta
lli
ng
(d)
Adju
s
tthe
el
ectrode
gap
to
0. 7
to
0.8
mm
(0.028"
to
0.031 ").
(e) Seat
spark
pl
ug
in pos i
tion
and
thread
by
harJd
to
prevent
cro
ss
threading.
(f
) Ti
ghten
plug
wi
t h
prov
i
ded
wren
ch
and
put
the
cap back
on
spark
plug
.
SIDE
ELECTRODE
S
PARK
PL
UG
:
TORCH
F6RTC
NGK
BPR6
ES
SEALING
WASHER
CHAMPION
RN9
YC equivalent.
Maintenance
Valve
Clearance
- Int
ake:
0.1 -
0.15
mm
(0.004
-
0.006
in.}
- Ex
haus
t : 0.1 - 0.
15
mm
(0.004
-
0.006
in
.}
To be
performed
by
kno
w l
edgabl
e/
ex
perlen
ced
ow
ner
or
by-authorized
s
er
vice
center
.
Cleaning
Fuel
St
r
aine
r
Dirt and water in the fuel are remov
ed
by t he f
ue
l
strainer.
(
a)
Remove
the
strainer cup and
thro
w away water
and dirt.
(bl Cl
ean
the screens and strainer c
up
w
ith
gasoline.
(
c)
Tightly fasten t
he
cup
to
main
body
,
making sure to avoid fuel
lea
k.
~ -
BODY
Cl>0--
--
SG
REE
N
~
0-
ri
ng
~
---
CUP
In
s
pect
Muffler
an
d
Spark
Arrester
Inspe
ct t he
muffler
for
cracks,
corro
si
on
, o r
other
damage.
Remove
the
spar
k
arre
s
te
r, if
equipped
,
and
i
nspect
for
damage
or
ca
rb
on
bl
ockage.
If
r
eplacement
p
arts
are
required
,
make
sure
to
u
se
only
origina
l
equipme
nt
rep la
cement
part
s.
A
WARNING
Exha u
st
heat/ gases
could
ign
ite
combus
tibles,
structures
or
damage
fue
l
tank
causing a
fi
re,
resulting
in
death
or
ser
i
ous
injur
y . C
onta
ct
w
ith
muffler
area co
uld
ca
use b urns resul
ti
ng
in serious
injur
y.
English
Pa
ge 20 Customer Servi
ce:
1-844-FIRMAN1
background
DO NOT touch
hot
parts and AVOID
hot
exhaust
Failure
to
clean
the
spark
arrester
wi
II
result
in
gases.
degraded
engine
performan
ce.
Allow
equipment
to
cool before touching.
Keep
at
least 5
feet
(1.5
m)
of
clearance on all
sides
of
generator including overhead.
Replacement
parts
must
be
the
same
and
installed
in
the
same
position
as
the
original
parts.
Clean
or
replace
spark
arrester
as
follows:
Depending
on
the
type
fuel used
,the
type
and
amount
of
lubricant
used,
and
/
or
your
operating
conditions,
the
exhaust
part
and
muffler
may
become
blocked
with
carbon
deposits.
If
you
notice
power
loss,
you
may
need
to
remove
these
deposits
to
restore
performance
.
1.
Allow
the
engine
to
cool
completely
before
servicing
the
spark
arrester.
2.
Remove
the
screws
securing
the
spark
arrester
in place
and
the
remove
it
from
muffler.
I~
f Spark
arrester
Screw
screen
3.
Carefully
remove
the
carbon
deposits
from
the
spark
arrester
screen
with
a
wire
brush.
4. Replace
the
spark
arrester
if
it
is
damaged
.
5.
Position
the
spark
arrester
in
the
muffler
and
a.ttach
with
the
screws.
GENERATOR
MAINTENANCE
Make
certain
that
the
generator
is
kept
clean
and
stored
properly
.
Only
operate
the
Unit
on
a
flat,
level
surface
in a clean,
dry
operating
environment.
DO
NOT
expose
the
unit
to
extreme
conditions,
excessive
dust,
dirt,
moisture
or
corrosive
vapors
.
NOTICE
DO NOT use a garden hose
to
clean
the
generator.
Water can
enterthe
generatorthrough
the
cooling
slots and damage
the
generator windings.
Use a
damp
cloth
to
clean
exterior
surfaces
of
the
generator.
Use a
soft
bristle
brush
to
remove
dirt
and
oil.
Use an
air
compressor
(25
PSI)
to
clear
dirt
and
debris
from
the
generator
_
Inspect
all
air
v
ents
and
cooling
slots
to
ensure
that
they
are clean
and
unobstructed.
SERVICE
AND
STORAGE
lnfrBQUBDI
SBrViCB
If
the
unit
is used
infre
quently
,
difficult
s
tarting
may
result.To
eliminate
hard
starting,
follow
these
instr
u
ctions:
1. Run
the
ge
nerator
at
least 30
minutes
every
month
.
2. Run
the
generator
,
then
close
the
fuel
shut-off
valve
and
allow
the
unit
to
run
until
the
engine
stops.
3.
Move
the
engine
switch
to
the
"OFF"
position.
English
Page
21
Cus
tomer
Se rvlce: 1-844-F IRMAN 1
background
Long
Term
Storage
It
is
important
to
prevent
gum
deposits from forming
in essential fuel zystem parts such
as
the carburetor,
fuel
hoses
or
tank during storage.
Also,
experience
indicates that alcohol-blended
fuels
(ca
lled gasohol,
ethanol
or
methanol)
can
attract moisture, which
leads
to
separation and formation
of
acids
during storage.
Acidic
gas
can
damage the fuel system
of
an
engine
while
in
storage.
When
the
generator
set
is
not
being operated,
or
is being stored
for
more than one month,
follow
these instructions
to
avoid engine problems:
1-ADD
a
properly
formulated
commercially
FUEL
STABILIZER to
the
tank
if
it
is
not
already added.
2-Operate
the
engine
for
5-10 minutes
to
circulate
treated fuel
into
fuel lines and carburetor before
shutdown.
3-After
engine
cools
down
,
remove
all
gasoline
from
the
fuel
tank.
Use a
commercially
available,
non-conductive
vacuum
siphon.
A
WARNING
Drain
fuel
into
approved
container
outdoors,
away
from
open
flame.
Be sure
engine
is
cool.
Do
not
smoke.
4-FUEL STARVATION: Start and run the generator
until
it
stops from lack
of
fuel. This will dry
out
all
remaining fuel
in
tank, fuel lines and carburetor.
5-A
llo
w
the
unit
to
coo
l
entirely
before
cleaning
and
sto
rage.
6-Change
oil
with
recommended
grade
oil.
7-Remove spark plug and
pour
about one teaspoon
of
engine
oi
l through
the
spark plug hole,
then
pull
the
recoil starter several times
to
distribute
the
oil
for
lubricating the cylinder. Reattach the spark plug.
Pull recoil slowly until resistance
is
felt. This will
close
the
valves
so
moisture cannot enter engine
cylinder. Gently release recoil starter.
8-Keep
the
engine
switch and fuel
valve
on
"OFF"
position.
9-Cover
the
unit
and
store
in a clean,
dry
place
out
of
direct
sun light. NEVER USE WATER
TO
CLEAN GENERATOR.
NOTE:
We
recommend
always using a fuel stabilizer.
A
FUEL
STABLIZER
will
minimize
the
formula-
tion
of
fuel
gum
deposits
during
storage,
the
fuel
stabilizer
can be added
to
the
gasoline
in
the
fuel tank,
or
into
the
gasoline
in a
storage
container.
If
it
is
not
practical
to
empty
the fuel tank and
the
unit
is
to
be stored
for
some time,
use
a
commercially available
FUEL
STABILIZER added
to
the gasoline
to
increase
the
life
of
the
gasoline.
Run
the
unit
for
5-10 minute
s,
tum
off the fuel
va
lve and allow
to
run until engine stops from
lack
of
fuel
(FUEL
STARVATION).
Any
damages
or
hazards caused
by
using
improper
fuel,
improperly
stored
fuel,
and/
or
improperly
formulated
stabilizers,
are
not
cov
ered
by
manufacturer's
warranty.
Do
not
store
gasoline
from
one
season
to
another
season.
English
Pag
e 22
Customer Service: 1 ·844- FIRMAN 1
background
TROUBLE
SHOOTING
Problem
Cause
Correction
1. Circuit breaker
is
open.
1.
Reset
circ
uit
breaker.
2.
Fau
lt in generator.
2.
Contact author
iz
ed service facil
ity
.
Engine
is
running,
but
no
3. P
oor
connection
or
defective cord
3.
Check and repair.
AC
output
is
available.
set.
4. Connected device is bad. 4. Connect another device that is in
good condition.
1.
Short circuit
in
a connected load.
1. Disconnect shorted electrical load.
Engine runs good
at
2.
Eng
ine speed is
too
slow.
2.
Contact authorized service facility,
no-load
but
"bogs down"
3.
Generator
is
overloaded.
3.
See
Don't·Overload Generat
or
lwhen
loads are connected.
4. Shorted generator circuit.
4.
Con
ta
ct
authorized service facility.
5.
Clogged
or
dirty
fuel filter.
5. Clean
or
repl
ace
f
ue
l filte
r.
1.
Eng
ine switch set
to
OFF
(0)
1. S
et
engine switch
tp
ON (1)
position.
position.
2.
Fu
el
shutoff
le
ver
is
in
OF
F (
0)
2.
Move fuel shuto
ff
lever
to
ON
(I
)
positro
n.
position.
3.
Lo
w
oi
l level.
3.
Fi
ll
cr
an
kcase
to proper level or
place generat
or
on level surface.
4.
Dirty air
clea
ner,
4.
Clean
or
replace air cleaner.
Engine
will not start; starti
5.
Out of fuel.
5.
Fill
fuel tan
k.
and
runs rough
or
shuts
6.
Stale fuel.
6.
Drain llJel tank and carburetor; nII
down when running.
w
it
h fresh fuel.
7. Spark plug w
ir
e
not
connected
to
7. Connect
wir
e
to
spark plug.
spark plug.
8.
Bad
spark plug.
8.
Rep
l
ace
spark p
lu
g.
9.
Water in fuel.
9.
Drain gas
tank
and
ca
rburetor,
fi
ll
wi
th
fresh fuel.
10. Flooded.
10.
Wa
it
5 mi
nutes
and
re
-
crank
eng
i
ne.
11
. E
xc
es
sively rich fuel mixture.
11
. Contact
au
thor
ized service facility.
1
2.
Intake
va
lve stuck open
or
closed.
12. Contact authorized service
faci
lity.
13. Engine
has
lo
st
compression.
13. Contact
au
thorized service facility.
14. Clogged or dirty fuel filter.
14. Clean
or
replace fuel fil
ter
.
1.
Load
is
too
high.
1.
Don't Overload Generator
Engine lacks
power
.
2.
Dirty air filte
r.
2.
Rep
lace air filter.
3.
Clogged or
dirty
fuel filter.
3.
Clean
or
replace fuel filter.
4. Clogged spark a
rr
ester.
4.
Clean
or
replace spark arrester.
1. Carburetor
is
running t
oo
rich
or
too
lea
n.
1. Contact authorized service f
aci
li
ty.
Engine
"hunts" or falters.
2.
Clogged
or
dirty
fuel filter. 2. Clean
or
replace fuel filter.
Engine shuts down
when
1.
Out
of
fue
l.
1.
Fi
ll fuel tank.
2. Dirty a
ir
cleaner. 2.
Cle
an
or replace air cleaner.
runni
ng
.
3.
Low
oil
leve
l.
3.
Fill
crankcase to proper l
evel
or p
la
ce.
generator on l
evel
surface.
Englisn
Pag
e23
Cus
tom
er
Se
rvice: 1 ·844·FIRMAN1
background
PARTS
DIAGRAM
AND
PARTS
LIST
PD3&11
Paris
Diagram
'
50
'
~
52
53
54
~
Eng
li
sh
Pa
ge 24
C
ustomer
Service: 1-844-FIRMAN1
background
FIRMAN208
cc
Engine
Paris
o-
1agram
r---
/
I
I
I
I
I
/
I
I
L
I
76
I
I
I
___
_J
En
glish
I
13
Page
25
Customer Se rvlce: 1-844-FIRMAN1
background
P03&11
Paris
Lisi
NO
. Part Number Descriotion
Qty_
NO. Part Number
Description
Qty_
1
336713626
FIRMAN 208cc Enaine 1
52
336713551 Fuel Valve
1
2
336713501
Rubber Cao 2
1
53
336713552
Guard
Muff..
1
3
336713502
Rubber
Cao1
1
54
336713553
Frame
1
4
336713503
RotorAssv 1 55
336713558
Nut
MB
8
5
336713504
Stator Assv
1
56
336713562
Isolator A
2
6
336713505
Stator Cover
1
57
336713563
Isolator B
2
7
336713506
Generator End Cover
1
58
336713564
Grommet 1
8
336713507
Flanae Bolt M5x12
3
59
336713565
Screw
M5
><
14
2
9
336713508
Flanae Bolt M8x252
1
60
336713566
Control Box 1
10
336713509
Lock Washer
08
3
61
336713567
Nut
M3
2
11
336713510
Flat Washer
08
1
62
336713568
Nut
M4
8
12
336713511 Flanae Bolt M6x179
4
63
336713569
S
crew&w
aSs
her
As
sy
M4x
8
5
13
336713512
Lock Washer
06
4
64 336713570 Multi Meter 1
14
336713513
Flat Washer
06
4
65 336713571 Control Panel 1
15
336713514
Ground Wire
1
66
336713572
Enqine Switch
1
16
336713515
Flanae Bolt M6x12
11
67
336713573
Outlet Cover L5-30R 1
17
336713516
Star Washer
06
1
68
336713574
Outlet Cover TT-30 R 1
18
336713517
NutM6
1
69
336713575
Outlet Cover 5-20R
1
19
336713518
AVR
1
70
336713576 Fia. Bolt M5x16 1
20
336713519
Flanae Bolt M5x16
2
71
336713577
Nut M5
1
21
336713520
Bolt &washer Assemblies
2
72.
336713578
Nut
M5
1
22
336713627
Generator End Cover Cao
1
73
336713579
Fl at Washer (5\
2
23
336713522
Ground Wire
1
74
336713580
Star Washer (5)
1
24
336713523
Terminal Block
1
75
336713581
Grommet
1
25
336713524
Bolt &washer Assemblies
1
76
336713582
Sleeve
1
26
336713525
Carbon Brush Holder
1
77
336713583
Receptacle L5-30R
1
27
336713526
Carbon Brush Assembly
1
78
336713584
Receptacle TT-30R
1
28
33
6713527
Air Cleaner Bracket
1
79
336713585
Circuit Breaker Amo 20A 1
29
336713528
Flanae Bolt M6x8
1
80
336713586
Circuit Breaker Amo 30A 1
30
336713529
Muffler Fixed Plate A (small
1
81
336713587
Grommet 1
31
336713530
Muffler Fixed Plate B (bia\
1
82
336713588
Receptacle 5-20R Duolex
1
32
336713531
Flanae Bolt M8x20 3
83
336713589
Screw&washer A
ss
y M5x 38
1
33
336713532
Muffler Gasket
1
84
336413500
Control Panel Assv 1
34
336713533
Flat Washer
08
2
85
336413502
Rotor And Stator Set
1
35
3367135
34
Nut
MB
2
86
336413503
Spark Arrestor Kit 1
36
336713535
Muffler Assemblv
1
37
336713536
Arrester Soark 1
38
336713537
Holder,
Spark
Arrester
1
39
336713538
Screw&wa
s
her
Assv
MS
x
14
2
40
336713539
Formed Vaoor Hose 1
41
336713540
Clamo08x6
3
42
336713628
Fuel TankAssv. 1
43
336713542
Grommet Fuel Tank 4
44
336713543
Washer Tank Buffer 4
45
336713544
Flanae Bolt M6x20
4
46
336713545
Fuel Gauae
Assv
1
47
336713546
ScrewM5
x1o
2
48
33
6713547
Fuel Gauae Disolav 1
49
336713548
Fuel Filter. Wire Mesh 1
50
336713549
Fuel Cao 1
51
336713550
Hose, Fuel
1
E;nglish
P
ag
e 26
C
i,
stom
er
Se
rvi
ce
: 1-844-FIRMAN1
background
FIRMAN
208cc
Engine
Parts
list
NO
.
Part
Number
Desc
ri
ption
Qty.
NO.
Part Number
Description
Qty.
1
336723500
Cr
ankcase
S
ub
asse
mbly.
1 54 336723553
Carburetor
1
2 33672
35
01
Lo
cat
in
g Pi
ns
2 55
336
7
2355
4
Gasket.
,
Alr
Cleaner
1
3 336723502
Se
nsor, Eng i
ne
O
il
1
56
336723555 NUIM6 3
4 3367
235
03
Fi
g. Bolt M6x
12
8
57
336723556
SpalkPlug
1
5 336723504
Camshaft
As
sy.
1
58
336723
55
7
Elbow
,
Air
Cleaner
1
6
336723505
Be
ari
ng
2 59
336723558
Clapboard
1
7 336723506
Gea
r,
Crankshaft
1
60
336723559
Mounttng
Boll.
Alr
Cleane
r
4
8 336723507
Wood
ru
ff
Key
1 61
336723560
E
lement,
Alr
Cleaner
1
9
336723508
Cra
nk
sha
ft
1
62
336723
561
Cover,
/!Jr
Cleaner
1
10
336723509
Gea
r, Dri
ve
1
63
336723562
ConlRll
Assemblv
1
11
336723510
G
as
k
et
, C
ra
nkcase
1 64
336723563
Shaft,
Governor
Ann
1
12
3367235
11
O
il
Di
pst
i
ckA
s
sy
1
65
336723564
RockerShim
1
13
336723512
Cove
r,
Cr
an
kcase
1 66
336723565
Pin
,
Shaft
1
14
33672
35
13
S
ea
l, Oil
2
67
336723566
Ann,
Governor
1
15
33672
351
4
Fi
g. Bolt M8x
32
6
68
336723567
Boll,
Governor
Arm
1
16
336723
51
5
Rod,
Co
n
nect
ing
1
69
336723568
Spnng
,
Governor
Ann
1
17 33672
35
16
Clip, Piston Pin
2
70
336723569
Rad,
Governor
1
18
336723517
Pin, Pi
sto
n
1
71
336723570
Sprina,
Throme
Return
1
19
336723518
Pi
ston
1
72
336723
571
Retainer,
Diode
1
20
336
72
35
19
Ring
Se
t, Oil
1
73
336723572
Wind
Deflectors
1
21
336723520 Rino, T
he
Second
1 74 336723573
lanition
Coi
l
1
22
336723521
Ring
,
Th
e F
irs
t
1
75
336723574
Fla.
Boll
M6•25
2
23
336723522
Fi
g. B olt M6 x8
3 76
336723575
Protect
Circle
1
24 336723523
A
ir
G
ui
de Lower
1
77
336723616
Fan
Cover
Comp
1
25
336
72
3524
Gas
ket,
Cy
linder H
ead
Cover
1
78
336723577
Fia
.
Bolt
M6•20
1
26
33
6723525
Cover
Suba
ssembly,
CyU
n
der
H
ead
1
79
336723578
Air
Guide
,
Riahl
Side
1
27
336723526
Fig.
B
oll
M6x15
7
80
336423505
Gaskei
Set
1
28
3367
235
27
Fl
ct
. Bolt M8x55
4
81
336723580 L
ock
nut 1
29
336723528
Nu
t,
Val
ve
Lock.
2
82
336723581
Pull
ev.s
ta
rt
er 1
30
336
72
3529
Nu
t Val
ve
Adjusting
2
83
336723582
Coo
lin
ct
Fan 1
31
336723530
Br
eat
her Tu
be
1
84
336723583 FIV
wl1
ee
l
Com
p
1
32
33
6723531
Roc
ker,
Va
l
ve
2
85
336723584
Gri
o,s
ta
rt
er
1
33
33
672
3532
Rot
at
or
, Val
ve
1
86
336723585
Ca
se
Como
. r
eco
il
Start
er
1
34
336723533
Re
ta
iner, I
nta
ke
Va
lve
1
87
336723586
Sp
ri
nQ
,
sta
rt
er
Return
1
35
336723534
Reta
in
er
, Ex
hau
st Val
ve
1
88
336723587
Co
rd
1
36
336723535
Spri
ng
, Val
ve
2
89
336723588 PUll
eV,
recoil
Starter
1
37
336723536
O
il
Sea
l, Valve 2
90
336723589
Sor
ina
.oa
tchet
2
38
336723537
Bo
lt,
Va
l
ve
Ad
ju
st
i
ng
2
91
336723590
Pa
tc
h
et
sta
rte
r
2
39
336723538
Pl
ate
Su
b
asse
mbl
y,
Lifter
Stopper
1
92
336723591
P
awl
G
ui
de
1
40
336723539
Exh
au
st
Va
l
ves
St
ud Bolt
2
93
336723592 Clio
So
ra ..
oaw
l Gui
de
1
41
336723540
Head
Su
b
assem
bl
y,
Cy
linder
1
94
336723593
S
cr
ew,pa
wl
G
ui
de
1
42
336
7
235
41
Val
ve,
In
ta
ke
1
95
3367235
94
Go
v ..
oea
r Sh
aft
1
43
33672
35
42
Va
l
ve,
Ex
hau
st
1
96
336723595
Inner
Was
l1er,
oea
r
1
44 336723543
Pu
sh Rod
2
97
336723596
Gear
Gove
r
no
r
1
45
336723544
Ta
pp
et, Val
ve
2
98
336723597
C
li
o, G
ovo
rner
Gear
1
46 336723545
Washer,
Dr
a
in
Bolt
2 99 336723598 B
us
hi
no
,
Govo
rner G
ea
r 1
47
33672
35
46
B
oll
, D
ra
in Plug
2
100
33
671
3532
Aus
o
uff
di
chtun
a
1
48
33672
35
47
Loc
al
in
g Pi
ns
2
101
336423500 Recoi I
Starte
r
Set
1
49 336723548
Gask
et
, Cy
li
nder
Head
1
102
33642
35
01
Gove
rn in a
Gear
Se
t
1
50
336723549
S
tud,
I
nta
ke
2
103
336423502
Air
Cleaner
Se
t
1
51
336
72
3550
Ga
sk
et,
Inl
et
1 1
04
336423503
Ca
rbur
etor
Se
t
1
52
33672
35
51
Plate,
Ca
rb
ur
etor
In
su
lat
or
1
105
336
4235
04
Pis
ton
Rin
as
Set
1
53
3367235
52
Gaske
t,
Carbur
eto
r
1
English
Pag
e27
Cus
tomer Service: 1 -
844
-F
IR
M
AN
1
background
E
ca
..
=
ca
·-
=
=
=
·-
..
·-
a
r-
··
-
-
i
FW
CIRCUIT
- · -
··
,
B~
R I .
(~
~
Rn
w
·7
I
I
5-20R
GROUND
!
» I GIY I i i
GNi
© RMINALI
I
I
I
I
I
1
IR
fw
IIDLTl
IIETJ!R
B
fG/Y
ENGINE
SWITCH
L
AL
TERNATOR BLOCK
· ·
· - · -
,-
- - -
--
- - - ·-
_
_j
~ <
?-----------<.
:fil
B
BLACK
Br
y
YELLOW
BNV
L
BLUE
WIG
Gr
GRAY
G/Y
R
RED
W/L
w
WHITE In
BROWN
I
BLACK WHITE I
WH
I
TE
GREEN I
GREEN YELLOW
WHITE BLUE
INDIGO
I
I
ENGINE
BLOCK-
,B
I
spft'
m IGNITION COIL
__
c?N_TR_oL
_
B_ox
_
BLOCK
I
------------.
".
<E-----;
y
~KING
PLUG
· -
- · · - - __ _
,,
__ _ ___ __ _
_ , _
OIL~VEL
SV{
__J
-z
<(
:,
~
LL
.,.
.,.
'\'
"
"
~
<1)
(J)
:0
E
~
::,
u
"'
N
"'
01
~
~
O>
C
LlJ
background
SERVICE
INFORMATION
CONTACT
THE
FIRMAN
PRODUCT
SERVICE
DEPARTMENT
AT
1-844-347-6261
or
at
www.firmanpowerequipment.com
to
obtain
warranty
service
information
or
to
order
replacement
parts
or
accessories.
HOW
TO
ORDER
REPlACEMENT
PARTS
Ev
en
quality built equipment
such
as
the
electric
generator
you
have
purchased
might
need
occasional
replacement
parts
to
maintain
it
in
good condition over the years.
To
order
replacement
parts
,
please
give the following
information:
WARRANTY
FIRMAN
Three
[3J
Year
limited
warrantv
Warranty
Qualifications
FIRMAN
GENERATOR
will
register
the
warranty
upon
receipt
of
your Warranty Registration
Card
and
a
copy
of
your
sales
receipt from one
of
FIRMAN
's
retail locations
as
proof
of
purchase
.
Please
subm
it
your warranty
reg
istration
and
your proof
of
purchase
within ten
(10)
days
of
the date
of
purchase.
Repair/Replacement Warranty
FIRMAN warrants
to
the
original
purchaser
that
the
mechanical and electrical
components
will
be free
of
defec
ts
in
material
and
workmanship
for
a
period
of
one
(1)
year
(parts and labor) and
three
(3) years (parts)
from
the
original
date
of
purchase 90 days [parts and
labor]
and
180
days
[parts]
for
commercial & industrial use.
T
ransportation
charges
on
product
subm
i
tted
fo
r
repair
or
replacement
under
this
warranty
are
the
sole
responsibility
of
the
purchaser.
This
warranty only applies to the original
purchaser
and
is
not transferable.
Do
Not
Return
the
Unit
to
the
Place
1. Model No. ,Rev. Level and Serial No. ar\d all
of
Purchase
specifications show!] on
the
Mo
del No_/$eri
al
Co
ntactthe
FIRM
AN
Se
rvice
Cen
t
er
and
FIRM
AN
No
. plate.
2.
Parts number or numbers
as
sho
wn
in t he
Pa
rts
Li
st se
cti
on
.
3.
A
br
ief descript io n of the
tro
uble
wit
h the
g
ener
ato
r.
( REGISTER
YOUR
PRODUCT)
Reg ister
your
Fin
11a
n
gener
a
to
r on line
at
www.firma
npowere
quipment.com
E
ng
li
sh
will t
rouble
sh
oot
any issue vi a phone
or
e-mail.
If
the
prob
lem is
not
co
rr
ected
by
th
is
met
hod,
FI
RMAN
wil
l,
at
its o
pti
on, au
tho
rize eva
luat
ion,
repair
or
replaceme
nt
of
the
defective part
or
compon
e
nt
at a
FIRM
AN
Se
rvi
ce
Ce
n
ter.
F
IR
MAN
will provide
yo
u with a ca
se
number
for
wa
rra
nty
service.
Ple
ase
keep it
fo
r
fu
t ure r
ef
eren
ce.
Rep
air
s
or
replacements wi
thou
t
prior
authoriz
-at
ion, or at an u naut
l)
orized repaj r fa
ci
li
ty
, wil I
not
be covered by t h is wa rranty.
Warranty Exclusions
This warranty does
not
cover the
following
repairs
and
equipment:
Normal
Wear
Yo
ur product needs
per
iodic parts and
servic
e
to pe
rf
or
m well. This warranty
do
es not cover
repair when n
or
mal use has
ex
ha
ust
ed the life
of
a p
art
or
the equi
pment
as a whole.
Customer Service: 1 ·844
·F
IRM
AN1
background
Installation, Use and Mainte.nance
This
warranty
will
not
apply
to
parts
and
/or
labor
if
your
produ
ct is
deemed
to
have been misused,
rie_gjected, irivolved in an acciderit, abused,
loaded
beyond
the
generator's
limits,
modified
,
installed
improperly
or
connected
incorrectly
to
any
electrical
component
No
rmal
maintenance
is
not
covered
by
this
wa
rr
anty.
Other Exclusions
This- w
arranty
excludes:
-
cosmetic
defects
such
as
paint
, decals,
et
c.
-wear
items
- accessory parts
- failures due
to
acts of God
and
other
force
maje
ure
events
beyond
the
manufacturer's
control
-
problems
caused
by
parts
that
are
not
original
FIRMAN
parts
-
units
used
for
prime
power
in place
of
exis
ting
utility
po
w
er
where
utility
is present or in place
of
utility
power
where
utilit
y
power
serv
ice does
not
normall
y exist.
Limits
of
Implied Warranty and
Consequential Damage
FIRMAN disclaims any obligation
to
cover any
loss
of
time, use
of
this product, freight,
or
any
incidental or consequential claim by anyone
from using this product. THIS WARRANTY IS
IN
LIEU
OF
ALL
OTHER WARRANTIES,
EXPRESS
OR
IMPLIED
,
INCLUDING
WARRANTIES
OF
MERCHANTABILITY
OR
FITNESS FOR A
PARTICULAR
PURPOSE.
A unit provided
as
an
exchange will
be
subject
to
the
warranty
of
the
original unit. The length
ofthe
warranty governing
the
exchanged unit
will remain calculated by reference
to
the
purchase date
of
the
original unit.
This.
warranty
gives you
certain
legal
rights
whi
ch
may
change
from
state
to
state
. Your
state
may also
have
other
rights you
may
be
entitled
to
that
are
not
listed
within
this
warranty
.
Contact
Information
You
may
co
nta
ct
Fl
RMAN
at
:
Address
Firman
Power
Equipment
Inc.
Attn
:
Customer
Service
8716
West
Ludlow
Dr.
Suite
#6
Pe
oria,
AZ
85381
www.firmanpowe
r
equip
ment.
com
We are FIRMAN
POWER
-And
we
are here
for
you
.
English
Page
30
Customer Service: 1-844-FIRMAN1
background
FIRMAN
POWER
EQUIPMENT
INC
.
Emission
Control
System
Warranty
CAUFORNIA
AND
FEDERAL EXHAUST
AND
EVAPORATIVE EMISSIONS CONTROL
WARRANTY
STATEMENT
YOUR
WARRANTY
RIGHTS
AND
OBLIGATIONS
The
California
Air
ResouI·ces Board, US Environmental
Protection
Agency
("US EPA") and
FIRMAN
POWER
EQUIPMENT
INC
.
(FIRMAN)
are
pleased
to
explain
th
e
emissions
control
systems
wa
rranty
on
yo
ur
2020-20
_
21
or
later
Small
Off
- Road
Engine
("SORE") and
engine
powered equipment.
In
California,
ne1V
equi
pment
th
at
use
small
oft-road
engines
must
be
de
s
igned
,
built
and
eq
uipped
to m
eet
the
Slate's
stringent
anti-s
mog s
tandar
ds
.
FIRMAN
must
warrant
the
e
mission
s
control
systems on
your
SORE
and
engine
po
we
red
equipment
for
the
periods
of
time
listed
below
provided
there
has
been
no
abuse,
neglect
or
improper
maintenance
of
your
small
off-road
engine
or
equipment
leading
to
the
failure
of
th
e
emissions
control
system
.
Your
emissions
contro
l
sys
tem
ma
y
include
parts
such
as
the
carburetor
or
fuel-
in
jection
system,
the
ignition
sys
tem,
ca
tal
ytic
conver
t
er,
fuel
tanks,
fuel
lines
(for
liquid
fuel
and
fuel
vapors),
fuel
caps,
valves,
can
ist
ers,
filters,
cl
amps
and
other
associated
co
mp
one
nts
. A
lso
included
may
be
hoses,
be
lts
,
co
nnectors,
and
other
emission-re
l
ated
ass
e
mblies
Wh13re
a
warrantable
condition
ex
ists,
FIRMAN
wi
ll
r
epa
ir
yo
ur
SOR
E
and
engine
powered
equipment
at
·
no
cost
to
you
inclijdlng
diagnosis,
parts
and
latior
,
MANUFACTURER'S
WARRANTY
COVERAGE:
The exhaust and evapor
ative
en,·jssions co
11trol
system
on
yo
u
rsmall
off
-r
oad
engine
an
ertgine powered
equipment
is warranted
for
two
years.
]f
any
emissions-related
part
on
yo
ur
sma
ll
off-road
engine
and
engine
powered
equipment
is defective, the
part
w
ill
be
repaired
orrep
laceo
by
l'JRMAN.
OWN
ER'S
WARRANTY
RESPONSIBILmES:
As
the
SORE
and
engine
powered
equipment
owne
r, you
are
respo
nsible
for
the
perforrn ance
of
the
required
maintenance
listed
in
yo
ur
ow
ner
's
manual.
FJRMAN
recommends tl~at
yo
u ret ain
all
receipt
s cove
ring
rnaintena nee on
you
r
SOR
E a()d
engioe
pow~r
ed
equipment,
but
FIR.MAN
can
not
de
ny
warranty
covera
ge
solely
fort
he
la
ck
of
rece
ipt
s
odor
yoLirfai
lur
e
tQ
ensure
the
perform
ance
of
a II scheduled n,air,tenance.
As t he
SO
RE
and
engine
po
we
red
equipment
13W
ner
,
yo
u
sholdd
however
be
awar·e that FIRMAN may deny
you
warranty
coverage
if
your
small
o!f
-
road
engine
or
engine
powered
equipmen
t
or
a
part
has failed
due
to
abuse,
neglect,
or
improper
maintenance
or
urrapproved
modifi
ca
tion
s.
You are respons
ible
/or
presenting
your
small o
r/
-r
oad
engine
and
engine
powered
equipmen
t t o a FIRMAN
di
st
ribution
center
or
service cen t
er
as soon as the
problem
e)(istsp The wa
rranty
repairs shall be com
pl
eted
in
a reasona ble
amoun
t of
ti
me,
not
to
exceed 30 days.
lf
you
ha
ve
a(ly
questions
regarding
yo
ur
wa
rrant
y
righ
ts
and
responsibi
lit
ies,
you
should
contact
flRMAN
at
1-844- 347-6261
or
supp
ort@firman
powereq u
ip
ment
.c.o
m.
FIRMAN Emission Control Defects
Warranty
Provisions
The w
arra11ty
period begins
011
the date
th
e·engine/e9uiprnent is deliver
ed
to
an ultimate purchaser.
FJRMAN
warrants
to
the
Ult jn,ate
plirchesera
nd
eac.h
subsequent purchaser that t he engine
is
:
Designed,
buil
t,
and
equipped
so
as
to
co
nform
wit
h all
applicable
regulations
adopte
d by the
Air
Resources Board and
US
EPA;
and Free
from
defects
in
materials and w
orkmanship
t
hat
cause
the
failure
of
a wa rran
te
d p
art
to
be
identical
in all
material
respects
to
th e
part
as
described
ifl
the
e
ngine
manufacturers applica
ti
on
fo
r
certification.
The-warranty
on
e-mis-sions-related parts, is
as
follows
:
(1)
An
yw
arranted
part
that
is
not
sched
uled
for
replace
ment
as
req
uir
ed
ma intenance in
the
owner
's
manual
supplied,
is
wa
rr
a
nted
for
the
wa
rran
ty
peri
od stated above.
Jf
any such
part
fails
during
the
pe
ri
od
of
warrant
y coverage,
the
par
t w
ill
be
repaired
or
replaced by
Fl
RMAN
at
no
charge
to
the
owner.
Any
such
par
t
repair
ed
or
feplaced
under
the wa
rr
a
nt
y will be
warranted
for
tl1e
remaining
warranty
period
.
(2)
Any warranted
part
that
is
sc
hedul
ed
oniy
forregular
inspection
in
the owner's manual ·
suppli
ed, is wa
rrant
ed
for
the
warranty
period
stated above.
Any
s
uch
pad
repaired
orreplaced
under
warran
ty
w
ill
be
warranted
for
t he
remaining
warran
ty
perio
d.
(3) Any warran
te
d
part
that
is sched Uled
for
replac
eme
nt
as
required main
te
nance in
the
o
wne
r's manual s
uppli
ed
, is warrant ed
fo
r
the
period
of
time
prior
to
the
first
scheduled
replacement
poin
t
for
t
hat
part
1f
the p
art
fai
ls
prior
to
the
first scheduled
replacement
, t
he
par
t w
ill
be
repaired
Qr
replaced by FIRMAN
a\
no
cha
rge
to
the
owner.
Any
su
ch
part
repaire
d
or
replaced
under
w
arrant
y
wjll
be wa
rranted
for
the
remainder
of
the
peri
od
prio
r-to
the
first
scheduled
replacement
poin
t
fort
he
pa
rt
,
{4) Repair or
repl
aceme
nt
of
any
wa
rrant
ed
part
under
the
wa
rrant
y must
be
perform
ed at
no
charge
to
the
owner
at
a
warranty
station
.
(5)
Notwithstanding
t
he
pro
visions
of
Sllbsection (4) above, wa
rrant
y
se
r
vi
ces
orrepairs
must be
pro
vide.d by
FI
RMAN t h
at
are franchised
to
s
efvke
the
s
ubject
engines.
(6) The
owner
must
not
be
c
harged
fo
r
diag
n
ost
ic
labor
t
hat
leads
to
the
determina
t
ion
th
at a
wa
rranted
part
is·in
fact
d
efer::
tive
provid
e.a
that
such a1agnostic
wo
rk
is
performed
at a warran
ty
statio
n,
{7}
F1R
MA N is
liable
for
damages
to
ot her e
ngine
e:
omponen
ts
pro
x
imatel
y caused by a failure
under
warranty
of
any
wa
rrant
ed
part
.
English
Page
31
Customer
Service
: 1-844-FIRMAN1
background
(
8)
Th
rough
out
the
emissions
warranty
period
defined in Subsection (b)(
2)
, FIRMAN w
ill
maintain a st1pply
of
warranted
par
ts
sufficient
to
meet
the
e)(pected
demand
for
such
parts.
(9)
Any
replacement
pa
rt
may
be
used
in
t he
perform
a n
ee
of
any
Wa
rrarity
maintenan
ce
or
repairs a rid
must
be
provided
witho
ut
charge
to
the
owner.
Such
use
will
not
reduce
t
he
warranty
obligations
of
the
manufacturer.
(10)
Add-on
or
modified
parts
that
are
not
exempted
by
the
Air
Resources Board may
not
be·used. The use
of
any non-e1<empted
add
-o
n
or
modified
parts
by
the
ultimate
purchaser
will
be
grolmds
for
disallowing a
warranty
claim.
The
manufacturer
will
not
be
liable
to
warrant
failures
of
warranted
par
ts
caused by
the
use
of
an
on•e:xempted add~on
or
modified
part
.
PA
RT
S
COVERED
BY
WARRANTY
Li
sted
belo
w
are
the
parts (
if
equipped
) covered by t he Federal and California Emission Ca
nnot
System Warran
ty.
Lignition
system
including
:
- Spark plug
-
Jg
11ition
c.o
il
2. Fuel metering system:
- Fuel l ank
- Fuel cap
- Fuel
line
s
(for
liquid
fuel and
fuel
vapors) and
related
fittings
/clam
ps
- Fuel regula
to
r,
ca
rburetor
and
internal
paft
S.
3, Catalytic
muffler
assembly
including
:
- Exha,ist
manifold
- Cata l
yt
ic converter
- M
uffler
gasket
-pulse valve
Lim
itations
4.
Air
induction
system
including
:
-
Int
ake
pipe/manifold
-
Air
cleaner
5.
Crankcase
breather
assembly
including
:
- Breather
connection
tu be
6.
F11el
tank evaporative emission
control
system
including:
- Purge valves
-
Ca
rbon canister
-V
a
por
hoses and
fifting/damps
This Emission Control System Warranty shall
no
t cover any
of
t
he
following:
(a) Consequential damages such
as
loss
of
time,
inconvenience,
loss
o/ use
of
the
engine
or
equipment,
etc.
(b) Diagnosis and inspection fees t
hat
do
not
result in
eligible
warranty
service being
performed.
FIRMAN
POWER
EQUIPMENT
INC.
www.firmanpowerequipment.com
English
Page
32
Customer
Service: 1-844-FIRMAN1
background
FOLLOW
US
ON
SOCIAL
MEDIA
USE
#EVERVCENERATORTELLSASTORV™
FOR
YOUR
CHANCE
TO
WIN
FIRMAN
SWAC
FIRMAN
POWER
EQUIPMENT INC.
8718
WEST
LUDLOW
DR. SUITE
#8
PEORIA,
AZ
85381
1
·844-147-6261
WWW.FIRMANPOWEREQUIPMENT
.COM
D
Cl
All
rights
r
ese
rved
.
Any
reprinting
o r
unauthori
zed
use
without
the
w
ritt
en
p
erm
i
ssio
n
ise:xpressly
pr
o
hibit
ed.
P/
N:336745460
Rev
06

Specifications

Firman P03611 Questions and Answers

See other models: P03609 P03606 P03603 P03602 P03601