20200326PEv1
Inverter Parallel Kit Operation
Works with 30A and 50A parallel kits
WARNING
Operating a generator can be dangerous if used improperly. Always refer to owners manual for safe and
proper operation of the generator.
This parallel kit is intended to be used only with Westinghouse inverter
generators. Please read safety information below before proceeding.
Installation and Operation:
1. Make sure both engine switches are in the o position, and conrm the ECO mode button on
both generators are turned o.
2. Connect the black and red parallel cable leads to the black parallel ports on each
corresponding inverters control panel. DO NOT connect two red leads or two black leads
into the same inverter.
3. Attach the ground terminal (green wire) from each end of the parallel cable to the
corresponding ground terminal on each generator.
4. Start each generator and conrm that the green output indicator is illuminated on both.
5. If using ECO throttle, turn both ECO switches on after the generators are started.
6. To shut down, turn o both generators and then remove the parallel cords.
NOTICE
If high electrical loads are connected, turn the ECO button to the OFF position
to reduce voltage changes. With the generators running, make sure both green
output indicator lights are ON. If not ON, turn the generators o, restart the
generators, and make sure both green output lights are ON.