V E N TA O RIGIN A L HUMIDIFIER
LW15 / LW2 5 / LW4 5
USER MANUAL
READ AND SAVE THESE
IMPORTANT INSTRUCTIONS
QUESTIONS?
SUPPORT HOTLINE
888-333-8218

VENTA HUMIDIFIER
USER MANUAL
ORIGINAL HUMIDIFIER MODELS LW15, LW25, LW45
CONTENTS
Important safeguards ----------------------------------------------------------------------------------3
Easy Setup Guide ----------------------------------------------------------------------------------------4
Parts List ------------------------------------------------------------------------------------------------9
Maintenance and Cleaning ------------------------------------------------------------------------10
Additional Products -----------------------------------------------------------------------------------11
Additional Information -------------------------------------------------------------------------------13
Troubleshooting ----------------------------------------------------------------------------------------14
FAQ ----------------------------------------------------------------------------------------------------------15
Servicing Your Humidifier --------------------------------------------------------------------------- 17
Warranty --------------------------------------------------------------------------------------------------------20
2
US

IMPORTANT SAFEGUARDS
WARNING
It is important that you read, fully understand, and observe the following safety pre-
cautions and warning. Read these instructions periodically. Careless or improper use
of your Venta Humidifier may cause serious or even fatal injury. Keep this User
Manual with your humidifier. Be sure anyone using your humidifier understands the
information contained in this manual.
• Children should not operate the humidifier.
• Always switch the motor off and unplug the power supply from the AC outlet before
filling it with water, adding Venta Water Treatment Additive, Venta Cleaner, Venta
Aromatherapy, or before moving/handling the unit.
• Plug into 110-120 V AC outlet only. Do not use your humidifier if the power supply or
plug is damaged. Do not replace a damaged power supply or plug. Only Venta may
replace the power supply or plug.
• The humidifier can only be operated with the Model No. BI13-240050-CdU power
supply (included).
• Do not attempt any repair work. Maintenance or servicing of the Venta Humidifier,
other than described in this user manual, should only be done by Venta. Any modifi-
cation to your humidifier is extremely dangerous and voids your warranty.
• Do not insert any objects into the air intake of the unit. It may damage the fan blades
or cause injuries. After the motor is switched off, the fan continues to rotate for a
short period of time.
• Do not use or store where it can fall or be pulled into a bathtub, sink, water, or other
liquid. Do not reach for a unit that has fallen into water or other liquid. Do not im-
merse in water or other liquid, even when the unit is unplugged or off. Moisture can
cause an electric shock hazard when the unit is again plugged into the AC outlet.
Wipe moisture off the unit with a dry cloth. Do not handle the switching power sup-
ply or the unit with wet hands.
• Use only genuine Venta Aromatherapy. Using non-Venta Aromatherapy will void the
warranty.
Read and follow separate instructions and Warnings for Venta Water Treatment
Additive, Venta Cleaner, and Venta Aromatherapy.
Please contact Venta Air Technologies Inc. at 888-333-8218 or
https://www.venta-air.com/en_us/service/contact/ for additional information.
3
US

EASY SETUP GUIDE
WELCOME TO THE VENTA COMMUNITY!
Setting up your humidifier is much simpler than you would expect. Just follow
these 7 steps and your humidifier will be up-and-running in less than 10 minutes!
1. UNPACKING
First things first, remove bottle(s) of Water Treatment Additive
from the corner of your packaging (o
ne sample bottle for LW15/
LW25 models, two sample bottles for LW45 models)
. Keep these
handy as you’ll need them in a bit. Unpack your
humidifier
setting the Styrofoam aside. You may want to return the
Styrofoam to the box and keep the box for any future humidifier
storage needs.
2. OPENING THE HUMIDIFIER
Open the top of your humidifier by releasing the tabs on the control panel and opening
the four panels, starting with the non-vented panels.
1 1
2
2
4
US

Lift the motor out of the housing, remove
the power cable, and set it aside for a mo-
ment.
On
the
Inside of one of the panels is a sticker with
the serial number on it. Write this number
down as you’ll need it later!
3. EXAMINE
YOUR HUMIDIFIER
Check both the upper housing and the motor for any cracks or damages. If both are
fine, place the motor back inside its housing, making sure to plug it back in as you do
so. Close the upper housing, starting with the vented panels, and clip the tabs. Set the
upper housing upside down.
5US

4. EXAMINE YOUR HUMIDIFIER (PART 2)
Remove the disc stack(s) from the lower housing and set them
aside. Remove the protective cardboard from the upper and
lower housings. Check the lower housing and the disc stack(s)
for any cracks or damages. If everything is fine, put the disc
stack(s) back in the lower housing.
Undo the tie holding the power cord and place the upper hous-
ing on the lower housing, guiding the power cord out through
the slot provided.
Please contact Venta Air Technologies Inc. at 888-333-8218 or
info-us@venta-air.com if there is any damage to your unit.
5. SET IT UP
Now it’s time to set up the humidifier. Find the place where you’d like your
humidifier to live, making sure to place it 18-20 inches from any walls or furniture for
best results!
Set the humidifier there, but don’t yet plug the unit in.
6 US

Remove the upper housing from the lower housing and set it aside for a
moment. Take the lower housing over to your sink/bathtub/water source and
fill it with regular tap water up to the water line. Remember the bottle(s) of
Water Treatment Additive? Go grab those and pour them into the water
in the lower housing. Once it’s filled, carry it back over to the upper housing.
Place the upper housing back onto
the lower housing.
6. TURN IT ON
Plug the humidifier in, press the power button, set the power setting to the
highest level, and enjoy the fresh air! At the highest power setting, the
humidifier will need to run continuously for about 7-10 days to properly
condition the room it is in. After that, you will notice the full impact of the
humidifier upon the air in your home!
7
US

4. ACTIVATE YOUR WARRANTY
Use the serial number to complete the online registration to activate your 2-year
warranty at https://www.venta-air.com/en_us/service/product-registration/.
Congratulations! Your
humidifier is now fully
functioning!
HELPFUL HINTS
• Dishwashers: The Venta Humidifier's lower housing, disc stack(s), and upper hous-
ing (first removing the motor assembly from the upper housing) can go into a
dishwasher on the cool or rinse cycle. It is recommended that it not be washed with
dishes. The motor assembly cannot be submerged in water or placed in the dish-
washer. DO NOT USE detergent, mild soap, bleach, or household cleaners.
• Cleaning of disc stack(s): If a dishwasher isn’t an option, cleaning the disc stack(s)
can be done by soaking disc stack(s) in hot water with Venta Cleaner or white
vinegar for approx. 30 minutes. This will help loosen any buildup of calcium or lime
that may have accrued. Always rinse with warm water after cleaning.
• Vinegar and Water Solution: Should be either a 50:50 or 3:1 ratio of white vinegar
and water used instead of Venta Cleaner.
• Do not use the appliance in an environment with temperatures consistently over 95
degrees Fahrenheit.
Please contact Venta Air Technologies Inc. at
888-333-8218 or info-us@venta-air.com
8
US

MAIN COMPONENTS
Disc Stack
Disc Stack Handle
Water Level Sensor Strip
Upper HousingLower Housing
Fan Blade
Gear Teeth
Gear Support
Arm
Rubber Coupling
Mounting Ring
Power Button
Continuous Lighting: On
No lighting: Off
Flashing: Fault
(See Eliminating Faults)
Power Level
Low Water
Indicator
Power Adjustment
Button
Gear Support
Arm
Gear
9
US

MAINTENANCE AND CLEANING
DAILY
fill with fresh tap water. Make sure you don’t dump the remaining water in the unit
when you fill it, as this water contains the Water Treatment Additive.
EVERY 10-14 DAYS
Rinse the lower housing and disc stack(s) with warm water. Wipe lower housing and
fan blade with a soft cloth. Recharge with the recommended dose of Venta Water
Treatment Additive and fresh tap water.
TWICE A YEAR
Use the Venta Cleaner periodically to thoroughly clean the Venta Humidifier. Or if you
prefer, Venta Air Technologies Inc. offers a professional cleaning through our
Ultrasonic Cleaning Program for an additional fee.
Call us toll-free at 888-333-8218 for details.
ANYTIME
Add 2-4 capfuls of our specially formulated Venta Aromatherapy.
TRANSPORTATION
Warning! Always switch off the motor and unplug the power supply from the
A/C outlet before moving the Venta Humidifier.
CLEANING THE METAL STRIPS
Scrub the thin metal contact strips that run down the inside of the lower housing unit
of any visible deposits or buildup. Use a kitchen scrubbing pad or old toothbrush dur-
ing the normal cleaning cycle to keep the unit running as designed.
10
US

VENTA WATER TREATMENT
ADDITIVE
APPLICATIONS
Venta Water Treatment Additive (WTA) is designed to maintain hygienic conditions
in the lower housing and to keep the evaporation process functioning at the highest
level. The use of WTA is recommended for the best performance and efficiency of
your Venta Humidifier. Proper usage will prevent the formation of hard calcium depos-
its. Simply rinse and wipe out any sediment when changing the water. WTA serves
three (3) purposes:
• It improves the performance of the humidifier by creating sheeting action on the
disc(s) with the effect of increasing the amount of surface area it covers.
• It helps remove calcium and lime buildup.
• It kills bacteria and mold.
DIRECTIONS
Fill lower housing with water daily. Approximately every 10-14 days (depending on
individual air and water quality) add a dose of WTA. The lower housing should be peri-
odically rinsed and cleaned approximately every 10-14 days. One dose of WTA is 3.5 fl.
oz. which is equal to one black marking on the left side of the label.
CAUTION! KEEP OUT OF REACH OF CHILDREN
EMERGENCY FIRST AID TREATMENT: Contains Quaternary Ammonium
Chlorides. Eye and skin irritant. In the event of contact with eyes flush thoroughly
with water. In the event of skin contact, rinse with water. Harmful if swallowed. Do not
induce vomiting. Seek medical attention. Venta WTA is recommended for use with the
Venta Humidifier only. Shelf life when stored in a cool location away from sunlight: 30
months. After opening, use within 12 months. WTA is not suitable for ultrasonic, heat
vaporizing, or atomizing-type vaporizer humidifiers. Not suitable for models with
Hygiene Disc.
CONTAINS: Water, wetting agents, softening agents, and preservatives.
WARNING!
Venta WTA is not intended to be used with detergents, cleaning agents, or other
chemicals. This will deactivate the additive. In cases when all water has evaporated,
Venta WTA remains in the lower housing – it does not evaporate (like salt in sea wa-
ter). Simply add more tap water and the WTA will activate. Venta Air Technologies Inc.
is not responsible for damages caused by noncompliance with above directions and
warnings.
To purchase products directly from Venta please shop online at
https://www.venta-air.com/en_us/products/ or call toll-free 888-333-8218.
You can also contact us by email: info-us@venta-air.com
11
US

VENTA CLEANER
USE EVERY SIX MONTHS OR MORE FREQUENTLY IF NEEDED.
1. For thorough cleaning, fill the lower housing with water before adding the entire
contents of the bottle. Run the appliance on the lowest setting for approximately
two hours.
2. Empty lower housing and rinse disc stack(s) and lower housing with warm water.
3. Fill lower housing with water and add one dose of WTA.
CAUTION! KEEP OUT OF REACH OF CHILDREN
EMERGENCY FIRST AID TREATMENT: In the event of contact with eyes flush thor-
oughly with water. In the event of skin contact, rinse with water. Contains: Water and
citric acid.
WARNING!
Venta Cleaner is recommended for use with the Venta Humidifier and Venta
Airwashers only. Shelf life when stored in a cool location away from sunlight: 30
months. After opening, use within 12 months. Venta Cleaner is not suitable for
ultrasonic, heat vaporizing, or atomizing-type vaporizer humidifiers.Venta Cleaner is
not intended to be used with detergents, cleaning agents, or other chemicals. Venta
Air Technologies, Inc. is not responsible for damages caused by noncompliance with
above directions and warnings.
VENTA AROMATHERAPY
Distinctive aromatherapy blends are specially formulated for your Venta
Humidifier and are water-soluble. Not suitable for models with Hygiene Disc.
DIRECTIONS
Add 2-4 capfuls of aromatherapy oil directly to the water in the lower housing.
Effectiveness: Depending on room size, about 2-4 hours.
CAUTION! KEEP OUT OF REACH OF CHILDREN
Combustible: Keep away from flame and heat.
Eye and skin irritant: Avoid contact with eyes, skin, and clothing. Prolonged contact
with skin may cause an allergic reaction.
Do not ingest.
First aid treatment: If in eyes, immediately flush eyes with water and seek
medical attention. If on skin, wash with soap and water. If swallowed,
Do not induce vomiting. Rinse mouth with water and call a physician or poison control
center immediately.
Contains: Fragrance oils. Wash hands after handling.
12
US

ADDITIONAL INFORMATION
AUTOMATIC SHUT-OFF
The appliance has an automatic shut-off feature that is indicated by the low water
Indicator illuminating
in the form of a red triangle.
Technical data
LW15 LW25 LW45
Colors black, white
For rooms up to 300 sq.ft. 430 sq.ft. 600 sq.ft.
Water hygiene
Water Treatment Additive
Power levels 2 3 3
Noise level (level 1-3) 22/32 dBA 24 / 34 / 44 dBA 24 / 35 / 45 dBA
Power consumption
(level 1-3) 3 / 4 Watt 3 / 5 / 8 Watt 3 / 5 / 8 Watt
Mains voltage 100-240 V
50-60 Hz
100-240 V
50-60 Hz
100-240 V
50-60 Hz
Water capacity (max.) 1.1 gallons 1.5 gallons 2.2 gallons
Dimensions 10.2×11×12.2 in 11.8×11.8×13 in 17.7×11.8×13 in
Weight 6.6 lb. 8.4 lb. 12.8 lb.
Warranty 2 years 2 years 2 years
Extremely low power consumption. Listed square feet are based on 8-foot ceilings.
The appliance will shut off
automatically if: What to do:
There is not enough water in the lower
housing.
Switch-off appliance, disconnect power
supply, top off with water, and start opera-
tion again with Power Button.
The upper housing has been opened. Close top cover again by pressing on the
external ends of the latches. Switch the ap-
pliance on and off with Power Button.
The upper housing is not installed
or is not properly fitted to the lower
housing.
Place top cover onto lower container.
Switch the appliance on and off with
Power Button.
13
US

TROUBLESHOOTING
Problem Possible causes What to do
Appliance does not
function
1. Power supply not
connected.
2. Cable connector not
plugged in and latched
into drive unit.
1. Connect switching power
supply to main socket,
switch on appliance.
2. Plug main cable connec-
tor into drive unit until it
latches.
Motor does not start and
the red triangle lights up
when lower unit is full of
water
The thin metal contact
strips that run down the
inside of the lower hous-
ing unit have a buildup of
mineral deposits.
1. Clean metal strips.
2. Wipe dry (see also “Main-
tenance and Cleaning”).
Clicking noise 1. Mineral deposit con-
tamination.
2. Rubber coupling is not
inserted all the way
into the gear.
1. Clean black gear prongs
with toothbrush.
2. Remove gear and reinsert
securely.
3. Call Customer Service:
888-333-8218
Wetness around the
appliance
Water has overflowed in
between the double mold-
ings of the lower housing.
Turn the empty lower hous-
ing upside down to dry.
Allow 24 hours to dry.
Disc stack(s) not turning The rubber coupling is
not securely inserted into
the gear.
Check that the rubber cou-
pling is properly inserted
into the bottom of the gear.
14
US

FREQUENTLY ASKED QUESTIONS
HOW DOES THE VENTA HUMIDIFIER HUMIDIFY?
The Venta Humidifier operates by the process of cold evaporation, so you will not see
any residue, vapors, or mists. The disc stack(s) rotates in the water creating a surface
area of over 45 sq. ft. (LW45). When dry air meets the surface area of the disc stack(s),
the water evaporates and is sent out into the room. By using the cold evaporation
process, any excess humidity can be virtually ruled out.
WHAT LEVEL OF HUMIDITY CAN BE EXPECTED AND HOW OFTEN SHOULD
THE LOWER HOUSING BE FILLED?
Under ideal conditions, a humidity level of 40-60 % can be expected. Some factors
affecting humidity level are heating/cooling, home insulation, layout of the home, air
circulation, and the amount of water in the appliance. For severely dry areas or during
the first days of use, you may notice the water evaporates more quickly, and/or a
lower humidity level will be reached. The water level of the lower housing should be
checked and topped off daily.
WHEN IS THE BEST TIME TO RUN THE VENTA HUMIDIFIER?
Always! The Venta Humidifier is designed to be a year-round, 24/7 product. Because
we wanted it to run year-round, we made the power consumption as minimal as
possible. For the best results, your humidifier should never be turned off or stored for
long periods of time.
WHERE IS THE BEST PLACE FOR THE VENTA HUMIDIFIER?
If possible, the Venta Humidifier should be placed in the center of the room, or along a
wall away from windows and a heat source. When using your Venta Humidifier for
multiple rooms (larger model Venta Humidifiers) it should be placed centrally between
rooms. Allow 18-20 inches above and on either side of the Venta Humidifier to allow
air circulation.
WILL OPENING OUTSIDE DOORS AND WINDOWS AFFECT THE
EFFICIENCY OF THE VENTA HUMIDIFIER?
The appliance works best in closed rooms to maintain a consistent level of humidity.
Just as windows and doors are closed when air conditioning is running, doors between
rooms may be left open to allow for air circulation.
15
US

IS IT NECESSARY TO USE THE VENTA WATER TREATMENT ADDITIVE?
The Water Treatment Additive helps prevent mineral deposits from becoming difficult
to remove so that any sediment can be rinsed out. In addition, the WTA helps improve
the efficiency of the Venta Humidifier by allowing the water to sheet on the disc
stack(s) instead of “beading” up, allowing maximum use of every square inch of the
disc stack(s). The WTA also helps prevent odors and improves the performance of the
Venta Humidifier. Not suitable for models with Hygiene Disc.
WHAT HAPPENS IF THE WATER EVAPORATES AND THE APPLIANCE CON-
TINUES TO RUN?
First and foremost, the Venta Humidifier is only humidifying when water is in the
appliance. However, the WTA holds dirt and dust particles down on the bottom of the
lower housing. The LW15/25/45 will shut off automatically as soon as there is
insufficient water in the lower housing.
SHOULD MORE WATER TREATMENT ADDITIVE BE ADDED WHEN THE AP-
PLIANCE HAS RUN DRY?
No, because the ingredients of the WTA do not evaporate. Simply add fresh water to
reactivate the WTA. One dose will help keep the Venta Humidifier from scaling up with
mineral deposits for 10-14 days.
WHAT HAPPENS WHEN THE VENTA HUMIDIFIER HAS NOT BEEN RUN FOR
AN EXTENDED PERIOD OF TIME?
Simply give the appliance a general cleaning with the Venta Cleaner before using it
again. Tip: Use of the Venta Cleaner is recommended before storing the appliance for
an extended period of time to remove any mineral deposits that can harden over time.
Or take advantage of Venta Air Technologies’ Ultrasonic Cleaning service. Call us toll-
free at 888-333-8218 for details.
MY VENTA HUMIDIFIER APPEARS TO NOT BE HUMIDIFYING MY ROOM AS
DESIRED
Our goal is to achieve 100% customer satisfaction. Initial product performance is
largely based on room size and the overall humidity level of the contents of the room.
Dry furnishings (textiles, leather, wood, books, etc.) will require a longer period to
absorb moisture until their humidity level is increased to a satisfactory level.
Therefore, we highly recommend that you consider this when evaluat-ing the
performance of your product. Dry rooms can take up to ten days of continu-ous
humidification to achieve an optimal humidity level. It’s important that you are adding
water to your unit regularly. In the event that you are dissatisfied with the performance
of your product, please call us for additional tips on how to maximize the performance
of your humidifier.
Did we not answer your question? Contact us at
[email protected] or call toll-free 888-333-8218.
16
US

SERVICING YOUR HUMIDIFIER
CLEANING THE GEAR
DO NOT submerge the gear in water. To clean any buildup of calcium or lime from
the gear “teeth,” brush with a soft-bristled brush. The gear teeth should be pointed
toward the floor while brushing, otherwise deposits will fall into the gear and cause it
to malfunction.
REMOVAL OF THE GEAR AND COUPLING
1. Switch the unit off.
2. Unplug the power cord from the
outlet.
3. Remove the motor from the upper
housing.
4. Remove the coupling from the gear
by pushing the coupling down to-
ward the fan and away from the
gear
5. Pivot turn the gear 90 degrees so that
it is laying on its side.
6. Gently pull one of the two motor as-
sembly arms approximately 1/8 of an
inch away from the gear and remove
the gear from the motor assembly.
7. Remove the locking ring from the
center shaft of the fan by prying it up
using a small screwdriver.
Fig 4. ... Push the coupling down ...
Fig 5. ... turn the gear 90 degrees ... Fig 6. ... gently pull one of the motor assembly arm 1/8
inch ...
17
US

REPLACING THE GEAR AND COUPLING
A. Place the rubber coupling into the locking ring so the rubber feet from the coupling
hang below the ring. When placing the coupling and ring on the center shaft of the
fan, the rubber feet should line up with the notch marks on the fan. Snap the ring and
coupling into place.
B. With the gear laying on its side, place it between the motor housing arms that sus-
pend it above the fan.
C. While placing the palms of your hands against the motor assembly arms, apply
slight pressure, and pivot the gear to the upright position. Check that the locking knob
is properly seated in the support arm.
D. Insert the rubber coupling into the bottom of the gear and push it up into the gear
until it fits tight. On models with a small white pin, first insert the pin through the
rubber coupling and then push both up into the gear until it fits tight. Check that this
is properly seated by spinning the fan with your hand. The teeth in the gear should
slowly move in and out.
A.... Place the rubber coupling into the
locking ring ...
B.... place it between the motor housing arms...
Fig 7. Remove the locking ring ... prying it up using a small screwdriver ...
18
US

• This optional service removes the buildup of dirt, lime, and calcium that may have
accrued over time. We will replace the gear box and rubber coupling. The result is a
clean, sanitized Venta Humidifier that will continue to humidify and cleanse your air.
This is an optional service offered by Venta, as the cost of roundtrip shipping and
the cleaning of your Humidifier unit is already factored into the price.
• Using adequate packing material, pack the unit inside a suitable shipping box.
• We will email you a prepaid mailing label. You can then print out the label on your
home printer or we can mail you a prepaid label using UPS.
• Drop the package off at any licensed UPS facility or you can have your shipment
picked up from your home or office by scheduling your pickup online at ups.com or
by calling 1-800-PICK-UPS (1-800-742-5877).
Fig D. ... and push it up into the gear until it fits tight ... models with a small white pin, first insert the pin
through the rubber coupling and then push both up into the gear until it fits.
ADDITIONAL SERVICE OPTIONS
If you prefer Venta to handle your concern, warranty repair, or if you wish to utilize the
Ultrasonic Cleaning service for your Venta Humidifier for an additional fee, please call
our customer support department toll-free at 888-333-8218 to obtain a Return
Merchandise Authorization (RMA) number and to make payment.
Carefully package the product in its original packaging and attach the provided shipping
label. Venta Air Technologies, Inc. is not responsible for damages to products shipped
with inadequate packaging.
ULTRASONIC CLEANING
19
US

TWO-YEAR LIMITED
WARRANTY
CALL VENTA CUSTOMER SUPPORT TO TROUBLESHOOT ANY ISSUES,
BEFORE ATTEMPTING TO RETURN THE PRODUCT TO RETAILER.
If you have any questions regarding this warranty, please call 888-333-8218
or write to:
Venta Air Technologies Inc.
US Headquarters
1111 North Plaza Drive, Suite 715
Schaumburg, IL 60173
For product registration please submit online at
https://www.venta-air.com/en_us/service/product-registration/.
Venta warrants that for a 2 years from the date of purchase, this product will be free
from defects in material and workmanship. Venta, at its option, will repair or replace
this product or any mechanical parts of the product to be defective during the warranty
period. Replacement will be made with a new or re-manufactured product or
component. If the product is no longer available, replacement may be made with a
similar product of equal or greater value. This is your exclusive warranty. This warran-
ty is valid for the original retail purchaser from the date of the initial retail purchase
and is not transferable. Please submit online at https://www.venta-air.com/en_us/
service/product-registration/ to activate your warranty. Also keep the original
sales receipt, as proof of purchase is required to process warranty claims.
This warranty does not cover normal wear of parts or damage resulting from any of
the following: Negligent use or misuse of the product, use on improper voltage or
current, use contrary to the operating instructions, disassembly, repair, or alteration by
anyone other than Venta Air Technologies Inc. Further, the warranty does not cover
Acts of God, such as fire, flood, hurricanes, or tornadoes.
Venta shall not be liable for any incidental or consequential damages caused by the
breach of any express or implied warranty. Except to the extent prohibited by appli-
cable law, any implied warranty of merchantability, or fitness for a particular purpose is
limited in duration to the duration of the above warranty. Some states, provinces, or
jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limita-
tions or exclusions may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights that vary from state to state.
20
US

Art.-No. 78500-36, ©2020/11_V01
Customer Support:
Venta Air Technologies Inc., US
Headquarters
1111 North Plaza Drive
Suite 715
Toll Free: 1-888-333-8218
www.venta-air.com/en_us
e-mail: info-us@venta-air.com