Masterforce HV-20SS-DC-MF 20" DC Shroud Floor Fan

Product's Documents

Below are documents related to this product, you can read online or download:
HV-20SS-DC-MF photo

User Manual

This is the main product document for model HV-20SS-DC-MF.

The file format is pdf, 4 pages, you can download this manual here .

background
1
20IN.INDUSTRIALSHROUD
DCFLOORFAN(2‐IN‐1)
MODELHV‐20SS‐DC-MF
OWNER’SMANU
AL
READANDSAVETHESEINSTRUCTIONS.
6211737
background
2
ASSEMBLYANDOPERATINGINSTRUCTIONS
CAUTION:
Readandfollowallinstructionsbeforeoperatingfan.
DONOTusefanifanypartisdamagedormissing.
WARNING:
Toreducetheriskoffireorelectricalshock,donotexposetowaterorrain.
Toreducetheriskoffireorelectricalshock,donotusethisfanwithanysolidstatespeedcontroldevice.|
Thisappliancehasa3‐prongplug.
Toreducetheriskofelectricalshock,thisplugis
intendedtofitinanoutletonlyoneway.
Ifthisdoesnotfittheoutlet,contactaqualified
electrician.Donotattempttobypassthisprocedure.
Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,itsserviceagentorsimilarlyqualified
personinordertoavoidahazard.
RULESFORSAFEOPERATION:
Neverinsertfingersoranyotherob
jects
throughthe
grilleguardwhenfanisinoperation.
Disconnectthefanwhenmovingfromonelocationtoanother.
Disconnect
thefanwhenremovinggrille guardsforcleaning.
Besurefanisonastable,fl
atsurf
ace
wheninoperation
.
DONOT
usefaninwindows.Rainandmoisturemaycreateelectricalhazard
.
CAUTION:Donotalterthefan’sassembly.
WARNING:BesureFRONTandREARGUARDscrewarecompletelyscrewed
downinlockingpositionbeforeoperation.
TUBEBASEASSEMBLYINSTRUCTIONS
1. Pressspringholder,slideoneendofVshapetubeto
theendoffantubewithsmallerhole.
2. SlideanotherendofVshapetubetotheendoffantube
withbiggerhole.
3. Aligntheseholes,andSecuringwiththespringholder.
NOTE:Thespringholdermustbefullytightenedbeforethefan
operating.
Figure. 1
SPRING
HOLDER
OPERATINGINSTRUCTIONS
TOADJUSTAIRFLOWUPWARDORDOWNWARD: Tiltfanheadtothedesiredangle.Thishigh
velocityfancanbeusedaloneorinconjunctionwithairconditioning.Rotatingthefanheadupward
servestopullairfromthefloorandcirculateitthroughouttheentireroom.
background
3
WARNING:
Mountfanonawoodenwallonly.
Toreducetheriskofelectricshockandpersonalinjury,
ensurethelocationforallmountingisabletosupportthisfan.
Totalweightoffanis14.5lbs(6.5kg).
Thisfanisrecommendedtobemountedbyaqualified
electrician.
CLEANINGINSTRUCTIONS
WARNING:
Unplugfromelectricalsupplysourcebeforecleaning.Afterservicing,anysafetydevice(includinggrillesand
blades)mustbereinstalledorremountedaspreviouslyinstalled:
Usesoftdampclothtoclean.Thenwipewithdrycloth.
Donotuseharmfulcleaners.
Donotbendtheblades.
Themotorbearingsarepermanentlysealedanddonotrequireadditionallubrication.
SPEEDCONTROL
RotateSwitchKnobfromLOWtoHI
GH speedsfo
rrespective
air
velocity.
Spe
edcontrolisvariablespeedregulation.
Itisnormalforthemotortofeelwarmtotouchaftercontinuousoperation.
TOINSTALLASWALLFAN
Securethehookthroughthetwoholesinthe
hookwithscrews(minimumsize:5/16‐18UNC)tothewall.
Securethefanonthehook.
WARNING:
Mountfanonawoodenwallonly.
Toreducetheriskofelectricshockandpersonalinjury,
ensurethelocationforallmountingisabletosupportthisfan.
Totalweightoffanis17.6lbs(8kg).
Thisfanisrecommendedtobemountedbyaqualifiedelectrician.
HowToAdjustTilt
1. Looseknobbyturningcounter‐clockwise.
2. Adjustfanheadtotileyouwant.
3. Tightenedtheknobbyturningclockwise.
KNOB
background
4
If you have any problems, operation questions or comments about this
product, contact us toll free at 1-888-372-8518 from 7:00 a.m. to 4:00 p.m. PST,
Monday to Friday or email us at [email protected]
WARNING:
Thisproductisnotintendedforusebypersons(includingchildren)withreducedphysical,sensoryormental
capabil
ities,orlackofexperienceandknowledge,unlesstheyhavebeengivensupervisionorinstruction
concerninguseoftheproductbyapersonresponsiblefortheirsafety.Childrenshouldbesupervisedto
ensurethattheydonotplaywiththeproduct.
Ifthesupplycordisdamaged,itmustbereplacedbythemanufacturer,itsserviceagentorsimilarly
qualifiedpersonsinordertoavoidahazard.
3Year LimitedWarranty
The manufacturer warrants this product to be free from manufacturing defects in material and workmanship
under normal use for a period of three (3) years after the date of purchase by the original purchaser. To
obtain warranty service, you must present a copy of the receipt as proof of purchase. This warranty does not
cover transit damages. This warranty does not apply to damages from accident, faulty installation, misuse,
abuse, alteration of any kind of fan or where the connected voltage is more than 5% above the nameplate
voltage. This warranty does not apply to the finish on any portion of the product. Servicing performed by
unauthorized persons shall render the warranty invalid.
For warranty service contact Customer Service at 1-888-372-8518, 7a.m.- 4p.m. PST, Monday-Friday.
Some states do not allow the limitation or exclusion of certain damages. Therefore, these limitations and
exclusions may not apply to you. This warranty gives the consumer specific legal rights. You may have other
rights that vary from state to state.
No.
Part Name No. Part Name
1
SPEED SWITCH KNOB
8
STAND
2
FRONT CONTROLLER BOX
9
WASHER
3
CONTROLLER PCBA
10
PLASTIC TIGHTENER
4 11
5 12
BLADE
6 13
FRONT GRILLE
7
REAR CONTROLLER BOX
POWER CORD
MOTOR
REAR GRILLE
METAL SHROUD
SCREW
14

Specifications