200593
Parameter&AFullPreviewofthe
Converter
InputVoltage
OutputVoltage
OutputCurrent
OutputPower
OutputRippleTypicalValue
VoltageResolution
CurrentResolution
VoltageAccuracy
CurrentAccuracy
Capacity
Energy
OperationTime
DROKDCAdjustableBuckConverter
Parameters
DC6.055V
DC0.050V
0.000A8.100A
0400W
Vpp150mv
0.01V
0.001A
±0.4%+1digit
±0.5%+3digits
0999999AH
0999999WH
01000Hours
IntheOFFstate,thesetvoltageand
currentaredisplayedclearlyand
intuitively.
IntheONstate,switchcurrentA,powerW,capacityAh,energy
Wh,operationtimeheasilybyrotatingthePotentiometerknob.
50002400
0652
CV
V
A
ON
50002400
1567
CV
V
W
ON
50002400
0004
CV
V
Ah
ON
50002400
0130
CV
V
Wh
ON
50002398
0005
CV
V
h
ON
CurrentPower Capacity
EnergyOperationTime
5000
1178
0653
CV
V
A
IN
ON
50002400
0000
CV
V
A
ON
50000000
0000
CV
V
A
OFF
InputVoltage(IN) TurnOn(ON) TurnOff(OFF)
50002400
0000
CV
V
A
ON
50001050
0558
CC
V
A
ON
ConstantVoltage(CV) ConstantCurrent(CC)
AlmostPerfectProtectionSystem:
HardwareProtection: Inputantireverseconnectprotectionand
outputshortcircuitprotection
SoftwareProtection:OverVoltageProtection(OVP),
OverCurrentProtection(OCP),
OverPowerProtection(OPP),
OverTemperatureProtection(OTP),
InputLowVoltageProtection(LVP)
Caution:Thisproductisdirectcurrent(DC)digitalcontrolvoltage
buckconverter,whichmeansoutputvoltagemustbelowerthan
inputvoltage(voltagedifference>0.05%+1V).Donotuse
alternationcurrent(AC)orinputvoltageoverpassestheinput
voltagerange.
PartsoftheConverter
Intelligentsilenttemperaturecontrolledfan:Whentemperatureis
over50℃orcurrentisover2A,thefanwillbeactivated
automatically.
5000
10
5000
8
OFF
SET
CV
V
A
5000
108
OFF
SET
A
15AIronSiliconAluminum
MagneticRingInductor
Pluggable
Terminal
Block
IntelligentSilent
TemperaturecontrolledFan
Thickened
HeatSink
OutputVoltagePositivePole
InputVoltagePositivePole
OutputVoltageNegativePole
InputVoltageNegativePole
5000
10
5000
8
OF F
SE T
CV
V
A
5000
OperationInstruction
500 0
10
500 0
8
OFF
SE T
CV
V
A
500 0
MainInterfaceofPowerSupply
PotentiometerKnob
ON/OFFButton

RecommendProduct
onAmazon:
12vto5vVoltConverter
VisitDROKStore
onAmazon
SettingVoltage:
Shortpressthepotentiometerknob,CVisflashing,voltageis
selectedandflashing.Shortpressthepotentiometerknobto
changetheselectedposition,rotatetheknobtochangevoltage,
rotateclockwisetoincrease,rotateanticlockwisetodecrease.
SettingCurrent:
Longpressthepotentiometerknobfor1second,whenCCis
flashing,currentisselectedandflashing.Shortpressthe
potentiometerknobtochangetheselectedposition,rotatethe
potentiometertochangecurrent,rotateclockwisetoincrease,
rotateanticlockwisetodecrease.
Afterfinishingsettingwithoutanyoperationfor3seconds,itwill
exitautomatically.
Theabovelineonthescreenshows
input/outputvoltage.“In”isinputvoltage.
IntheONsituation,longpressthe
ON/OFFbuttonfor2secondstoswitch
input/outputvoltage.
50001178
0653
CV
V
A
IN
ON
Inparametersettinginterface,userscansetdefaultvalueofCV
orCCbyshortlypressingthepotentiometerknob.
CV
V
OFF
SET
CC
V
OFF
SET
CV:Ifthedefaultsettingis
voltage,thenlongpressthe
knobfor1secondtoswitch
tocurrentsetting.
CC:Ifthedefaultsettingis
current,thenlongpressthe
knobfor1secondtoswitch
tovoltagesetting.
AftersettingCC,thedefaultparameteristoadjustthevalueof
constantcurrent.WhenrunningLED,itisveryconvenientto
achievefastdimmingthroughrotatingthepotentiometerknob.
IntheOFFstate,thevoltageandcurrent
isclearandintuitive.
LockingFunction:Longpressthe
potentiometerknobfor5secondsto
lockthesetvoltageandcurrentincase
ofwrongoperation!Afterbeinglocked,
pressthepotentiometerknobfor5
secondstounlock.
5000
10
5000
8
OFF
SET
CV
V
A
5000
50002400
0652
CV
V
A
ON
Longpressandrotatethepotentiometerknobfor3secondsto
enterthesettinginterface
5000
10
5000
8
OFF
SET
CV
V
A
5000LUP
CV
V
0480
IN
OFF
SET
OverVoltage
Protection(OVP):
DefaultSetting52.00V
5000
10
5000
8
OFF
SET
CV
V
A
5000OUP
CV
5200
OFF
SET
InputLowVoltage
Protection(LVP):
DefaultSetting4.8V
OverPower
Protection(OPP):
DefaultSetting410W
OverCurrent
Protection(OCP):
DefaultSetting8.20A
5000
10
5000
8
OFF
SET
CV
V
A
5000OCP
CV
820
OFF
SET
A
OPP
CV
41OO
OFF
W
SettingMaximum
Energy(OPH)
SettingMaximum
Capacity(OAH)
OAH
CV
0515
OFF
SET
Ah
OPH
CV
0689
OFF
SET
Wh
SettingON/OFFState
CC
OFF
SET
CV
SET
ON
ON:DefaultONAfterPowerOn OFF:DefaultOFFAfterPowerOFF
CC
OFF
SET
CV:DefaultSettingConstantVoltage CC:DefaultSettingConstantCurrent
UserscansetdefaultvalueofCVorCCbyshortlypressingthe
potentiometerknob.
CV
OFF
SET
Attention:Afterprotectionbeingactivated,outputofthepower
supplywillbecutoffandthecorrespondingprotectioncodewillbe
shownonthescreen.Protectioncodes:LVP/OVP/OCP/OPP/OAH/
OPH/OHP.
SettingInterfaceOperatingInstruction
Longpressthepotentiometerknobfor3secondstoenterthe
settinginterface.
Rotatethepotentiometertoadjusttheparameter,shortpressthe
potentiometerknobtoswitchtheparameteryouwouldliketo
adjust.
Ontheinterfaceofmaximumcapacity(OAH)ormaximumenergy
(OPH)ormaximumoperatingtime(OHP),shortpress“ON/OFF”
buttontoturnonoroffthecorrespondingfunction.Ifuserschoose
OFFtoturnoffonefunction,itwilldisplayas “”.
Ontheinterfaceofmaximumcapacity(OAH)ormaximumenergy
(OPH),longpress“ON/OFF”buttontoselectcapacityrange
(9.999Ah/99.99Ah/999.9Ah/9999Ah,9.999Wh/99.99Wh/
999.9Wh/9999Wh).
Afterfinishingparametersetting,longpressthepotentiometer
knobfor3secondstoexitsettinginterfaceandallsetting
parameterswillbeautomaticallysaved.
Functiondetails
Capacity/Energy/OperationTimeRecord
Recordwillbestartedautomaticallywhenthepowerison,and
thenumericalvalueofthelaststatewillbedisplayedwhenthe
powerisoff.Afterthepowerisonagain,therecordwillbe
automaticallyrestarted;Inthecorrespondinginterface,press
theON/OFFbuttonfor3secondstoautomaticallyclearthe
correspondingdata.
SettingMaximumCapacity/Energy/OperationTime
Settingmaximumcapacity(OAH)/energy(OPH):Whenthe
OAH/OPHfunctionisactivated,andtherecordedcapacity/
energyishigherthanthesettingmaximumcapacity/energy,the
powersupplywillautomaticallyturnofftheoutput,and“OAH”/
“OPH”willflashonthescreen.Afterthealarmislifted,the
capacity/energystatisticswillbeclearedautomatically.
Settingmaximumdischargetime(OHP):WhentheOHP
functionisactivated,andthepowerrunningtimeislongerthan
thesettingmaximumdischargetime,thepowerwillautomatically
turnofftheoutput,and“OHP”willflashonthescreen.Afterthe
alarmislifted,thetimestatisticswillbeclearedautomatically.
Thisfunctioncanachievequantitative/timingpowersupply.
Attention:WhenOAP/OPH/OHPfunctionsarenotactivated,
thepowersupplywillalsoautomaticallyrecordthecapacity/
energyandoperationtime.WhenOAP/OPH/OHPfunctionsare
activated,thepowersupplywillautomaticallyturnofftheoutput
if thesettingvalueisreached;AftertheOHPfunctionis
activated,therunningtimeofthepowersupplyisincountdown
mode.
Size
79mm/3.11in
43mm/1.69in
45mm/1.77in
25mm/0.98in
11mm/0.43in
39mm/1.54in
12mm/0.47in
71.3mm/2.81in
78mm/3.07in
Suggestedopeningsizeasbelow