Qasair Rangehoods Installation Instructions4
CONDARI PTY LTD makes over 120 different models of QASAIR Rangehoods plus
many special rangehoods designed by architects and interior designers.
It is important to follow the installation instructions.
There are many different cooking appliances on the Australian market today.
Examples: Electric Ego, ceramic hotplates, teppanyaki plates and Induction hotplates. There are gas hotplates
drawn out from the catchment area of the rangehood.
minimum should be 750mm.
.
way, as this may result in reduced performance.
IMPORTANT INFORMATION

Qasair Rangehoods Installation Instructions
5
by warranty.
gas or other fuels.
6. WARNING:
from burning gas or fuel;
b) For cleaning purposes please refer to
d) Some parts of the rangehood may become hot when cooking;
e) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
or instruction concerning use of the appliance by a person responsible for their safety.
9. NOTE
for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted
and not near the outer edges where leakage may occur.
only through single sheet material.
name.

Qasair Rangehoods Installation Instructions28
INSTALLATION INSTRUCTIONS
• WES
• EAS
3.
4.
5.
6. Fit off ductwork as required.
7.
Model: WES Model: EAS
EASTMORE
RANGEHOOD SPRING BRACKETS
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
1
1
2
2
3
3
4
4
5
5
6
6
A A
B B
C C
D D
Cupboard
Front of Rangehood
A
B
C
B
C
D
D
A

Qasair Rangehoods Installation Instructions
29
Eastmore
Technical Specification Sheet
EAS
Undercupboard
Motor Qty
LED Light
Nightlight
Model
Body Width
Motor Box /
Flue Width
Light Qty
Light Centres
Filter Qty
Cool
YES
1
565mm
600mm
EAS 60L-1
2
Page 1 of 2
All-thread
Fixing Centres
Condari Pty Ltd.
PowderKote
Available
2
380mm
EAS 80L-2
2
300mm
780mm
Minimum Height
(H =)
Model
Maximum Height
(H =)
Corner Type
Square
N/AN/A
Version: B 02/12/2014
Square
Electrical Connection
N/A
N/A
272mm
YES
EAS 60L-1 EAS 80L-2
Cool
YES
800mm
2
2
10 Amp Lead
YES
379mm
10 Amp Lead
N/A
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
N/A
Power entry location
is the same for all
EAS models.
Motor Access
Panel
Motor Access
Panel
EASTMORE - EAS

Qasair Rangehoods Installation Instructions30
Eastmore
Technical Specification Sheet
EAS
Undercupboard
Body Width
LED Light
Motor Qty
Model
Light Qty
Light Centres
Filter Qty
YES
2
430mm
Cool
EAS 90L-2
900mm
2
Nightlight
2
PowderKote
Available
Maximum Height
(H =)
Version: B 02/12/2014F
N/A
Square
Condari Pty Ltd.
All-thread
Fixing Centres
Corner Type
480mm
2
YES
Cool
2
Motor Box /
Flue Width
10 Amp Lead
EAS 90L-2
429mm
N/A N/A
Page 2 of 2
2
880mm
Square
N/A
N/A
YES
479mm
N/A
Electrical Connection
Model EAS 100L-2
YES
10 Amp Lead
1000mm
980mm
EAS 100L-2
Minimum Height
(H =)
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
Power entry location
is the same for all
EAS models.
Motor Access
Panel
Motor Access
Panel
EASTMORE - EAS

Qasair Rangehoods Installation Instructions
31
Westmore
Technical Specification Sheet
WES
Undercupboard
Motor Qty
LED Light
Nightlight
Model
Body Width
Motor Box /
Flue Width
Light Qty
Light Centres
Filter Qty
Cool
YES
1
565mm
600mm
WES 60L-1
2
Page 1 of 2
All-thread
Fixing Centres
Condari Pty Ltd.
PowderKote
Available
2
380mm
WES 80L-2
2
300mm
780mm
Minimum Height
(H =)
Model
Maximum Height
(H =)
Corner Type
Square
N/AN/A
Version: B 03/12/2014F
Square
Electrical Connection
N/A
N/A
272mm
YES
WES 60L-1 WES 80L-2
Cool
YES
800mm
2
2
10 Amp Lead
YES
379mm
10 Amp Lead
N/A
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
N/A
Power entry location
is the same for all
WES models.
Motor Access
Panel
Motor Access
Panel
WESTMORE - WES

Qasair Rangehoods Installation Instructions32
Westmore
Technical Specification Sheet
WES
Undercupboard
Body Width
LED Light
Motor Qty
Model
Light Qty
Light Centres
Filter Qty
YES
2
430mm
Cool
WES 90L-2
900mm
2
Nightlight
2
PowderKote
Available
Maximum Height
(H =)
Version: B 03/12/2014F
N/A
Square
Condari Pty Ltd.
All-thread
Fixing Centres
Corner Type
480mm
2
YES
Cool
2
Motor Box /
Flue Width
10 Amp Lead
WES 90L-2
429mm
N/A N/A
Page 2 of 2
2
880mm
Square
N/A
N/A
YES
479mm
N/A
Electrical Connection
Model WES 100L-2
YES
10 Amp Lead
1000mm
980mm
WES 100L-2
Minimum Height
(H =)
Filter Size
Conversion
Top/Back Back/Top
N/A
N/A
Power entry location
is the same for all
WES models.
Motor Access
Panel
Motor Access
Panel
WESTMORE - WES

Qasair Rangehoods Installation Instructions
101
FILTER CLEANING
RANGEHOOD CLEANING
For the best results, please clean filters regularly. Condari recommends cleaning filters
You can do this by hand washing in warm soapy water, or by placing filters in the top rack
dishwasher may cause discolouration of the filters.
Ensure the filters are completely dry before placing them back. Do not operate the
rangehood without the filters installed.
Condari does not recommend the use of any citrus or industrial products, particularly
•
•
Stainless Steel cleaner may be used.

Qasair Rangehoods Installation Instructions102
CONDARI PTY LTD APPLIANCE GUARANTEE
The benefits conferred by this warranty are in addition to all other rights and remedies in
respect of the product which the consumer has under the Competition and Consumer Act
that the appliance will be free from defects in materials and workmanship for a period of 36
months from the date of purchase of the appliance to the consumer.
of the appliance to the customer.
This warranty is conditional upon the appliance being used only for personal, domestic and
household purposes and installed and operated in accordance with QASAIR Instructions and
does not apply to articles which by their nature are consumable.
If a defect is caused by neglect, misuse, or failure to follow operating instructions where
special precautions are detailed
call.
For example:
With the filters the user is specifically requested:
• To clean filter regularly by handwashing or placing in a dishwasher at least once a month.
• To turn rangehood off after each use.
Where a claim is made under warranty,
of parts from the unit or to their replacement. Amongst other things, such responsibility shall
extend to damaged walls, tiles, fixtures and fittings whether or not the unit has been built

Qasair Rangehoods Installation Instructions
103
EXCLUSIONS
outdoor use only and also a mega joule rating per burner or a total mega joule rating.
special hoods are required for the appliances.
situated in domestic kitchens.

Qasair Rangehoods Installation Instructions104
Date purchased
Purchased from
Model
original purchase document. This form must be produced if and when
a claim is made under this warranty.
QASAIR Rangehoods are made in Ringwood, Australia.
Email: [email protected]
STANDARD
WARRANTY