Regulatory Informaon
FCC Informaon
Please take aenon that changes or modicaon not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable
protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the
instrucons, may cause harmful interference to radio communicaons. However, there is
no guarantee that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television
recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the
separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit
dierent from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC
Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired
operaon.
DS-K1T809 Series Access Control Terminal User Manual
i

EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
under the EMC Direcve 2014/30/EU, the RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed
of as unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated
collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for specic baery informaon. The baery is marked with this
symbol, which may include
leering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the
baery to your supplier or to a designated
collecon point. For more informaon see:www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operaon is subject to
the following two condions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence.
L'exploitaon est autorisée aux deux condions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2.
l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est
suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a
type and maximum (or lesser) gain approved for the
transmier by Industry Canada. To reduce
potenal radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut fonconner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intenon des
autres
ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
DS-K1T809 Series Access Control Terminal User Manual
ii

rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et
votre corps.
DS-K1T809 Series Access Control Terminal User Manual
iii

Safety Instrucon
These instrucons are intended to ensure that user can use the product correctly to avoid danger
or property loss.
The
precauon measure is divided into Dangers and Cauons:
Dangers: Neglecng any of the warnings may cause serious injury or death.
Cauons: Neglecng any of the cauons may cause injury or equipment damage.
Dangers: Follow these safeguards to prevent
serious injury or death.
Cauons: Follow these precauons to prevent
potenal injury or material damage.
Dangers
●
All the electronic operaon should be strictly compliance with the electrical safety regulaons,
re prevenon regulaons and other related regulaons in your local region.
●
Please use the power adapter, which is provided by normal company. The power consumpon
cannot be less than the required value.
●
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or
re hazard.
●
Please make sure that the power has been disconnected before you wire, install or dismantle the
device.
●
When the product is installed on wall or ceiling, the device shall be
rmly xed.
●
If smoke, odors or noise rise from the device, turn
o the power at once and unplug the power
cable, and then please contact the service center.
●
Do not ingest baery, Chemical Burn Hazard.
This product contains a
coin/buon cell baery. If the coin/buon cell baery is swallowed, it
can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used
baeries away from children. If the baery compartment does not close
securely, stop using the product and keep it away from children. If you think baeries might have
been swallowed or placed inside any part of the body, seek immediate medical
aenon.
●
If the product does not work properly, please contact your dealer or the nearest service center.
Never
aempt to disassemble the device yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
Cauons
●
This equipment is not suitable for use in locaons where children are likely to be present.
●
Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnesm radiaon. Avoid the equipment installaon on vibraons surface or places
subject to shock (ignorance can cause equipment damage).
DS-K1T809 Series Access Control Terminal User Manual
iv

●
Do not place the device in extremely hot (refer to the specicaon of the device for the detailed
operang temperature), cold, dusty or damp locaons, and do not expose it to high
electromagnec radiaon.
●
The device cover for indoor use shall be kept from rain and moisture.
●
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or
radiator is forbidden (ignorance can cause
re danger).
●
Do not aim the device at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a
malfuncon however), and aecng the endurance of sensor at the
same
me.
●
Please use the provided glove when open up the device cover, avoid direct contact with the
device cover, because the acidic sweat of the ngers may erode the surface coang of the device
cover.
●
Please use a
so and dry cloth when clean inside and outside surfaces of the device cover, do
not use alkaline detergents.
●
Please keep all wrappers aer unpack them for future use. In case of any failure occurred, you
need to return the device to the factory with the original wrapper.
Transportaon without the
original wrapper may result in damage on the device and lead to addional costs.
●
Improper use or replacement of the
baery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used baeries according to the instrucons provided by
the
baery manufacturer.
●
You can view the device License via the website: hp://opensource.hikvision.com/Home/List?
id=46
.
DS-K1T809 Series Access Control Terminal User Manual
v

Available Models
The access control terminal contains the following models:
Product Name Model
Access Control Terminal DS-K1T809MWX
DS-K1T809EWX
DS-K1T809 Series Access Control Terminal User Manual
vi

Contents
Chapter 1 Appearance ................................................................................................................ 1
Chapter 2 Installaon ................................................................................................................. 2
2.1 Installaon Environment ........................................................................................................ 2
2.2 Surface Mounng .................................................................................................................. 2
Chapter 3 Device Wiring ............................................................................................................. 6
3.1 External Device Wiring ........................................................................................................... 6
Chapter 4 Operate on the Device ................................................................................................ 7
4.1 Common Commands ............................................................................................................. 7
4.2 Basic Commands .................................................................................................................... 8
4.2.1
Acvaon ...................................................................................................................... 8
4.2.2 Enter and Exit Programming Mode ............................................................................... 9
4.3 Other Common Commands ................................................................................................. 10
4.3.1 Open Door .................................................................................................................. 10
4.3.2 Set
Funconal Card ..................................................................................................... 11
4.4 Advanced Commands .......................................................................................................... 12
4.4.1 Set Door Parameters ................................................................................................... 12
4.4.2 Set Voice Parameters .................................................................................................. 13
4.4.3 Set NFC ........................................................................................................................ 13
4.4.4 Set Card Reader Wiegand Mode ................................................................................. 13
4.4.5 Restore to Default
Sengs ......................................................................................... 13
4.4.6 Restart Device ............................................................................................................. 14
4.4.7 Restore to Factory
Sengs ......................................................................................... 14
Chapter 5 Congure the Device via the Mobile Web ................................................................. 15
5.1
Acvate via Mobile Web ...................................................................................................... 15
5.2 Login .................................................................................................................................... 15
5.3 Quick Operaon via Web Browser ....................................................................................... 16
DS-K1T809 Series Access Control Terminal User Manual
vii

5.3.1 Time Sengs ............................................................................................................... 16
5.4 Overview .............................................................................................................................. 16
5.5
Conguraon ....................................................................................................................... 17
5.5.1 View Device Informaon ............................................................................................. 17
5.5.2 Time Sengs ............................................................................................................... 17
5.5.3 Set DST ........................................................................................................................ 19
5.5.4 Change Administrator's Password on Mobile Web ..................................................... 19
5.5.5 Network Sengs ......................................................................................................... 20
5.5.6 User Management ...................................................................................................... 21
5.5.7 Search Event ................................................................................................................ 23
5.5.8 Access Control Sengs ............................................................................................... 23
5.5.9 Upgrade and Maintenance ......................................................................................... 27
5.5.10 View Online Document ............................................................................................. 28
Appendix A. Legal Informaon ................................................................................................. 29
Appendix B. Symbol Convenons ............................................................................................. 31
Appendix C. Dimension ............................................................................................................ 32
DS-K1T809 Series Access Control Terminal User Manual
viii

Chapter 1 Appearance
Refer to the following contents for detailed informaon of the access control terminal:
Figure 1-1 Access Control Terminal
Note
The pictures here are for reference only.
DS-K1T809 Series Access Control Terminal User Manual
1

Chapter 2 Installaon
2.1 Installaon Environment
●
The minimum bearing weight of the wall or other places should be 3 mes heavier than the
device weight.
●
• Please prepare the following tools and accessories: screwdriver (self purchased), screws,
cables, and adapters (self purchased).
2.2 Surface Mounng
Steps
1.
Aach the installaon scker to the wall about 1.45 m from the ground or the locaon where
the device needs to be installed, and punch the hole according to the hole
locaon (hole 1 and
hole 2) on the scker and wall.
Figure 2-1 Installaon Scker
2.
Insert the plasc sleeve of the provided expansion screw into the punched hole.
DS-K1T809 Series Access Control Terminal User Manual
2

Figure 2-2 Insert Plasc Sleeve
3.
Make sure the cables are threaded through the hole.
Figure 2-3 Thread Cables
4.
Secure the mounng plate on the gang box with two supplied screws (PA4X25-SUS).
DS-K1T809 Series Access Control Terminal User Manual
3

Figure 2-4 Secure Mounng Plate
5.
Complete the wiring. See the wiring diagram for details.
Figure 2-5 Complete Wiring
6.
Hang the device into the plate from top to boom. Secure the device on the mounng plate
with 1 supplied screw (SC-KM3X6-T10-SUS).
DS-K1T809 Series Access Control Terminal User Manual
4

Figure 2-6 Secure Device
DS-K1T809 Series Access Control Terminal User Manual
5

Chapter 3 Device Wiring
3.1 External Device Wiring
Wire the external device.
The wiring diagram is as follows.
Figure 3-1 External Device Wiring
Note
●
Use a DC 12 V power supply. Do not connect the device directly to the 220 V mains.
●
The suggested external power supply for door lock is 12 V, 1 A.
DS-K1T809 Series Access Control Terminal User Manual
6

Chapter 4 Operate on the Device
4.1 Common Commands
Table 4-1 Common Commands Descripon
Module Operaon Command Descripon
Acvate Device Acvate [*][0][#] [Programming
Password (6 to 8
Digits )] [Repeat
Programming
Password (6 to 8
Digits) ] [#]
The 6 to 8 digits
programming
password cannot all be
0.
Programming Mode Enter Programming
Mode
[Programming
Password (6 to 8
Digits )] [*][0][#]
/
Go back to
Programming Mode
[*] /
Exit Programming
Mode
[*] [#] The device will
automacally exit the
programming mode
aer 30s of no
operaon.
Change Programming
Password
[00] [New
Programming
Password (6 to 8
Digits )] [Repeat New
Programming
Password (6 to 8
Digits) ] [#]
/
Add Door Opening
Credenal
Set Door Opening
Password
[03] [Door Opening
Password (4 to 8
Digits )] [Repeat Door
Opening Password (4
to 8 Digits) ] [#]
/
Add User Card [01] [User Code (4
Digits )](Oponal)
[Swipe Card]...
If you choose to add a
user code, you can
DS-K1T809 Series Access Control Terminal User Manual
7

Module Operaon Command Descripon
save the added card to
the user code locaon.
Delete User Card [02] [Swipe Card]... /
Add User Cards in
Batch
[01] [User Code (4
Digits )](Oponal)
[Swipe Card 1][Swipe
Card 2][Swipe Card
3]...
/
Delete User Cards in
Batch (Method 1)
[02] [Swipe Card 1]
[Swipe Card 2][Swipe
Card 3]...
/
Delete User Cards in
Batch (Method 2)
[15] [Programming
Password (6 to 8
Digits )] [#]
/
Delete User Code [02] [User Code] [#] /
Delete User Codes in
Batch
[02] [User Code] [#]
[User Code] [#]...
/
4.2 Basic Commands
The device needs to be acvated before it can be used. Aer acvang, the device can be at two
modes: normal mode and programming mode. Aer entering programming mode, the device can
be operated by commands.
4.2.1
Acvaon
Command
Acvate: [*][0][#] [Programming Password (6 to 8 Digits )] [Repeat Programming Password (6 to 8
Digits) ] [#].
Note
The 6 to 8 digits programming password cannot all be 0.
DS-K1T809 Series Access Control Terminal User Manual
8

Prompts Descripon
Indicator Prompt Audio Descripon
Light is solid green. The buzzer rings for 3 s. Acvated , and in normal mode
(not programming mode).
Light ashes red slowly for 3
mes.
The buzzer rings for 5 mes
quickly.
Acvang failed.
Light ashes orange slowly. / Inacvated
4.2.2 Enter and Exit Programming Mode
There are two ways to enter the programming mode: enter the command , or directly swipe the
funconal card (including management card, adding card and deleng card).
Programming Mode Command
Enter Programming Mode: [Programming Password (6 to 8 Digits )] [*][0][#].
Exit Programming Mode: [*] [#].
Change Programming Password: [00] [New Programming Password (6 to 8 Digits )] [Repeat New
Programming Password (6 to 8 Digits) ] [#].
Table 4-2 Prompts
Descripon
Indicator Prompt Audio Descripon
Light is solid green for 2 s. The buzzer rings 2 mes quickly. Enter Programming Mode
Light is solid red for 2 s. The buzzer rings 3 mes slowly. Entering Programming Mode failed
/ The buzzer beeps 1 sound. Swipe Card and Press Buon Prompt
Audio
/ The buzzer rings 2 mes. Exit due to meout.
Note
●
Aer 5 consecuve programming password input errors, the device will enter a locked status.
Aer waing for 1800 s or aer the device losing power me cleared, you can enter the
programming password again to enter the programming mode. Enter the programming
password in the locked status, the indicator will be solid orange for 2 s, and the buzzer will ring 5
mes quickly, indicang that it cannot enter the programming mode.
●
In programming mode, "*" represents a fallback to programming mode without entering a
command, and "# "Indicates the end or compleon of a command.
●
In programming mode, you need to press "*" to exit the batch
addion and deleon mode.
DS-K1T809 Series Access Control Terminal User Manual
9

Swipe Funconal Card
Aer swiping the funconal card in the card swiping area, you can directly enter the programming
mode. See Set Funconal Card for adding details.
4.3 Other Common Commands
4.3.1 Open Door
There are two ways to open door: enter the password, or swipe user card.
Prompts
Descripon
Indicator Prompt Audio Descripon
Light is solid green for 2 s. The buzzer rings 2 mes quickly. Authencated
Light is solid red for 2 s. The buzzer rings 3 mes slowly. Authencaon failed.
/ The buzzer beeps 1 sound. Swipe Card and Press Buon Prompt
Audio
/ The buzzer rings 2 mes. Exit due to meout.
Set Door Opening Password
You can set the door opening password and open door by entering the door opening password.
Command
Command of Seng Door Opening Password: [03] [Door Opening Password (4 to 8 Digits )]
[Repeat Door Opening Password (4 to 8 Digits) ] [#].
Note
The 4 to 8 door opening password cannot all be 0. If all of them are 0, the door opening password
funcon will be disabled.
Add/Delete User Card
Command
Add User Card: [01] [User Code (4 Digits)] (Oponal)[Swipe Card ]...
DS-K1T809 Series Access Control Terminal User Manual
10

Add User Card in Batch:[01] [User Code (4 Digits )](Oponal) [Swipe Card 1][Swipe Card 2][Swipe
Card 3]...
Note
●
If you enter a user code before adding a card, the locaon of the added user card is under this
code ID, and if you do not enter the user code, the added card has no xed posion.
●
The user code format is 4 digits and the range is from1 to 1000. If the entered code content and
format is incorrect, the
addion fails, and the current adding command ends.
Delete User Code: [02] [User Code] [#].
Delete User Code in Batch: [02] [User Code] [#][User Code] [#]...
Delete User Card: [02] [Swipe Card].
Delete User Card in Batch (Method 1): [02] [Swipe Card 1] [Swipe Card 2][Swipe Card 3]...
Delete User Card in Batch (Method 2): [15] [Programming Password (6 to 8 Digits )] [#].
4.3.2 Set
Funconal Card
Funconal cards include management card, adding card and deleng card.
Note
Funconal cards cannot be used to open door, but are only equivalent to a certain command.
Management Card
Swipe the management card in the standby status: it means that the device directly enters the
programming mode, and there is no need to enter the command to enter the programming mode.
Command of Adding Management Card: [04] [Swipe Card].
Command of
Deleng Management Card: [05][#].
Command of Adding Management Card, Adding Card and Deleng Card at Once: [10] [Swipe
Management Card][Swipe Adding Card] [Swipe
Deleng Card].
Note
Aer swiping the management card to enter the programming mode, if the device is not operated
for 30 s, it will exit programming mode. Swipe twice in 3 seconds to switch door contact sengs.
When switching the door contact, the buzzer ringing 8 mes slowly means that the mode is
switched to remain closed, and the buzzer ringing 8
mes quickly means that the mode is switched
to remain open.
Adding Card
Swipe the adding card in the standby status: it means that the device directly enters the
programming mode, and enters the [01] command (adding command).
For example, if you need to add a user card, you can swipe the adding card and then swipe a user
card when the device is in standby status.
DS-K1T809 Series Access Control Terminal User Manual
11

Command of Adding Adding Card: [06] [Swipe Card].
Command of Deleng Adding Card: [07][#].
Note
Aer swiping the adding card to enter the programming mode, if the device is not operated for 30
s, it will exit programming mode.
Delete Card
Swipe the deleng card in the standby status: it means that the device directly enters the
programming mode, and enters the [02] command (deleng command).
For example, if you need to delete a user card, you can swipe the
deleng card and then swipe a
user card when the device is in standby status.
Command of Adding Deleng Card: [08] [Swipe Card].
Command of
Deleng Deleng Card: [09][#].
Note
Aer swiping the deleng card to enter the programming mode, if the device is not operated for
30 s, it will exit programming mode.
4.4 Advanced Commands
4.4.1 Set Door Parameters
The door opening me, door opening meout, door contact type and exit buon type can be set
by command.
Command: [11] [Data Bit 1] [Data Bit 2] [Data Bit 3] [Data Bit 4] [#].
Data Bit 1: Indicates the door opening
me, which is a three digits number from 000 to 255. The
unit is second. If the door opening
me is 3 s, the data bit 1 is set to 003. The default door opening
me is 5 s.
Data Bit 2: Indicates the door opening
meout, which is a two digits number. The unit is second. If
the door is opened beyond this seng me, the device will alarm and ring for 10 s. If you enter
"50", the alarm me for door opening meout will be 50 s. The default door opening meout is 30
s.
Data Bit 3: Indicates the type of door contact, which is a one digit number. "0" means remaining
closed, and "1" means remaining open. It is remaining closed by default.
Data Bit 4: Indicates the type of exit
buon, which is a one digit number. "0" means remaining
closed, and "1" means remaining open. It is remaining closed by default.
DS-K1T809 Series Access Control Terminal User Manual
12

4.4.2 Set Voice Parameters
You can set whether to enable the buon sound and authencaon prompt audio through the
command.
Command: [12] [Data Bit 1] [Data Bit 2] [#].
Data Bit 1: Indicates whether to enable the
buon sound, which is a one digit number. "0" means
the
buon sound is disabled, and "1" means the buon sound is enabled. It is enabled by default.
Indicates whether to enable the
authencaon prompt audio, which is a one digit number. "0"
means the
authencaon prompt audio is disabled, and "1" means the authencaon prompt
audio is enabled. It is enabled by default.
Note
The disabling only takes eect in the normal mode, not in the programming mode.
4.4.3 Set NFC
You can set whether to enable NFC funcon through the command.
Command: [13] [Data Bit 1] [#].
Data Bit 1: “0" means disabling NFC
funcon, and "1" means enabling NFC funcon. It is enabled
by default.
Note
Only some models support this funcon, please refer to the actual product.
4.4.4 Set Card Reader Wiegand Mode
The Wiegand mode of card reader can be set by command.
Command: [14] [Data Bit 1] [#].
Data Bit 1: "0" means Wiegand 26 mode, and "1" means Wiegand 34 mode. The default mode is
Wiegand 34.
4.4.5 Restore to Default
Sengs
You can perform commands or press buon to restore to default sengs.
Command 1: [16] [Programming Password (6 to 8 Digits )]] [#] (Only Restore Data Except User
Cards Data).
Command 2: Press and hold the "*"
buon for 5 seconds within 30 seconds of powering on.
DS-K1T809 Series Access Control Terminal User Manual
13

4.4.6 Restart Device
You can restart the device by command.
Command: [17] [Programming Password (6 to 8 Digits )] [#].
4.4.7 Restore to Factory Sengs
You can restore the device to factory sengs by command.
Command: [18] [Programming Password (6 to 8 Digits )]] [#] (Restore All User and Default Data).
DS-K1T809 Series Access Control Terminal User Manual
14

Chapter 5 Congure the Device via the Mobile Web
The device supports acvaon and operaon through device-side commands. It also supports
acvaon and operaon on the mobile phone by connecng to the device hotspot. (If it is
acvated through the mobile phone, it cannot be operated through the device. If it is acvated
through the device, you can operate on the mobile phone. )
5.1 Acvate via Mobile Web
You can acvate the device via mobile web.
Steps
1.
Aer the device is powered on, the hotspot is enabled by default. Search for and connect to the
device hotspot on your phone.
Note
●
Device hotspot name is AP_ Serial No., and inial password of device hotspot is Serial No.
Aer restarng or switching from non-AP mode to AP mode aer acvaon (press and hold
the number buon 5 to switch AP mode), the hotspot password will be changed to the
acvaon password.
●
You can log in to the mobile web client only when the device is in AP mode.
2.
Open the browser address bar of the mobile phone and enter 192.168.8.1 to enter the
acvaon interface.
3.
Set the
acvaon password and conrm it.
Note
●
The password must be 8 to 16 characters long.
●
The password must be composed of two or more combinaons of numbers, lowercase leers,
uppercase leers, and special characters.
●
The password cannot contain the user name, 123, admin, 4 or more
consecuve digits in
increments or decrement, or the same symbol.
4.
Tap Acvate Device.
5.2 Login
You can log in via mobile browser.
Note
●
Parts of the device models support this funcon.
●
Make sure the device is acvated.
DS-K1T809 Series Access Control Terminal User Manual
15

Enter the device IP address in the address bar of the mobile browser and press Enter to enter the
login page.
Enter the device user name and the password. Tap Login.
5.3 Quick Operaon via Web Browser
5.3.1 Time Sengs
You can set the me zone, me synchronizaon mode, and the displayed me.
Device Time
Display the device me in real me.
Time Zone
Select the device located me zone from the drop-down list.
Time Synchronizaon Mode
NTP
You should set the NTP server's IP address, port No., and interval.
Manual
By default, the device
me should be synchronized manually. You can set the device me
manually or check Sync. with Phone Time to synchronize the device me with the phone's
me.
DST
You can enable DST, set and view the DST start
me, end me and bias me.
Click Next to save the sengs.
5.4 Overview
You can view the door status, network status and basic informaon, and set person management,
authencaon sengs, and door parameters via shortcut entry.
Funcon Descripons:
Door Status
/ / /
The door status is open/closed/remaining open/remaining closed. You can tap to select
open/closed/remaining open/remaining closed status according to your actual needs.
Shortcut Entry
You can set person management, authencaon sengs, and door parameters via shortcut
entry.
DS-K1T809 Series Access Control Terminal User Manual
16

Network Status
You can view the connected status of wireless network and Hik-Connect.
Basic Informaon
You can view the model, serial No. and rmware version.
5.5 Conguraon
5.5.1 View Device Informaon
View the device name, language, model, serial No., version, number of channels, IO input number,
number of alarm input and output, Mac address, factory
informaon and device capacity, etc.
Tap → System Sengs → Basic Informaon to enter the conguraon page.
You can view the device name, language, model, serial No., version, number of channels, IO input
number, number of alarm input and output, Mac address, factory
informaon and device capacity,
etc.
5.5.2 Time
Sengs
Set the me zone, me sync. mode, and displayed me.
Tap → System Sengs → Time Sengs to enter the sengs page.
DS-K1T809 Series Access Control Terminal User Manual
17

Figure 5-1 Time Sengs
Tap Save to save the sengs.
Time Zone
Select the me zone where the device is located from the drop-down list.
Time Sync. Mode
Manual
You can set the device me manually, or enable Sync. with Phone Time.
NTP
DS-K1T809 Series Access Control Terminal User Manual
18

Set the NTP server's IP address, port No., and interval.
5.5.3 Set DST
Steps
1.
Tap
→ System Sengs → Time Sengs , to enter the sengs page.
Figure 5-2 DST
2.
Tap Enable DST.
3.
Set the start
me, end me, and DST bias.
4.
Tap Save.
5.5.4 Change Administrator's Password on Mobile Web
You can change administrator's password.
Steps
1.
Tap → User Management → admin to enter the sengs page.
2.
Enter the old password and create a new password.
3.
Conrm the new password.
4.
Tap Save.
Note
The password strength of the device can be automacally checked. We highly recommend you
change the password of your own choosing (using 8 to 16 characters, including at least two kinds
of following characters: upper case leers, lower case leers, numbers, and special characters,
and do not contain following characters in the password: the user name, 123, admin (case
insensive), 4 or more connuously increasing or decreasing digits, or 4 or more consecuvely
repeated characters) in order to increase the security of your product. We recommend you
DS-K1T809 Series Access Control Terminal User Manual
19

change your password regularly, especially in the high security system, changing the password
monthly or weekly can beer protect your product.
5.5.5 Network Sengs
Set Device Hotspot
Set the device hotspot, and mobile phone can connect to the device to enter the mobile browser.
Steps
1.
Tap → Network Sengs → Device Hotspot .
2.
You can enable device hotspot and view the hotspot name.
Note
By default, the hotspot name is the AP_Device Serial No.
3.
Tap Save.
Plaorm
Access
Plaorm access provides you an opon to manage the devices via plaorm.
Steps
1.
Tap → Device Access → Hik-Connect to enter the sengs page.
Note
Hik-Connect is an applicaon for mobile devices. With the App, you can view live image of the
device, receive alarm nocaon and so on.
2.
Check Enable to enable the funcon.
3.
You can view Network Connecon Status and Account Linkage Status.
4.
Tap Save to enable the
sengs.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1.
Tap
→ Access Conguraon → Wiegand Sengs .
DS-K1T809 Series Access Control Terminal User Manual
20

Figure 5-3 Wiegand Page
2.
Enable Wiegand to enable the Wiegand funcon.
3.
Set a transmission direcon.
Note
The device can connect an external access controller. And the two devices will transmit the card
No. via Wiegand 26 or 34.
4.
Tap More, and you can set Time Interval and Pulse Width.
5.
Tap Save to save the
sengs.
5.5.6 User Management
You can add, edit, delete, and search users via mobile Web browser.
Steps
1.
Tap → Person Management to enter the sengs page.
DS-K1T809 Series Access Control Terminal User Manual
21

Figure 5-4 User Management
2.
Add user.
1) Tap+.
2) Set the following parameters.
Employee No.
Enter the employee No. The Employee No. cannot be 0 or exceed 32 characters. It can be a
combinaon of uppercase leers, lowercase leers and numbers.
Name
Enter your name. The name supports numbers, English uppercase and lowercase leers
and Chinese characters. The name is recommended to be within 32 characters.
Long-Term Eecve User
DS-K1T809 Series Access Control Terminal User Manual
22

Set the user permission as long-term eecve, or set the start date and end date of user
permission.
User Type
Select your user role.
Card
Add card. Tap Card, then tap +. Enter the card No. or swipe the card to read card No., and
then select Card Type.
3) Tap Save.
3.
Oponal: Tap the user that needs to be edited in the user list to edit the informaon.
4.
Oponal: Tap the user that needs to be deleted in the user list, and tap to delete the user.
5.
Oponal: You can search the user by entering the employee ID in the search bar.
5.5.7 Search Event
Tap → Search to enter the page.
Enter the search
condions, including the event type, major type, sub type, employee No., card
No., start me, and end me, and tap Search.
Note
Support searching for names within 32 digits.
5.5.8 Access Control Sengs
Set Authencaon Parameters
Set Authencaon Parameters.
Steps
1.
Tap → Access Control → Authencaon Sengs .
DS-K1T809 Series Access Control Terminal User Manual
23

Figure 5-5 Set Authencaon Parameters
2.
Tap Save.
Terminal
Select the terminal.
Authencaon Type
Select an authencaon type according to your actual needs from the drop-down list.
Authencaon Interval
You can set the authencaon interval of the same person when authencang. The same
person can only authencate once in the congured interval. A second authencaon will be
failed.
Max. Authencaon Failed Aempts Alarm/Max. Authencaon Failed Aempts
Aer you enable Max. Authencaon Failed Aempts Alarm, you can set Max.
Authencaon Failed Aempts. The device will automacally generate and report alarm
events aer the authencaon failures exceed the congured aempts.
DS-K1T809 Series Access Control Terminal User Manual
24

Max. Interval When Entering Password
You can set the Max. meout period for password entry, aer which the password input will
be invalid.
Enable Card No. Reversing
If this funcon is enabled, the card reader will reverse the order of the card No. aer reading
them.
Set Door Parameters
Tap → Access Control → Door Parameters .
DS-K1T809 Series Access Control Terminal User Manual
25

Figure 5-6 Door Parameters Sengs
Tap Save to save the sengs aer the conguraon.
Door Name
You can create a name for the door.
Door Opening Duraon(s)
Set the door open duraon.
Exit Buon Type
DS-K1T809 Series Access Control Terminal User Manual
26

You can set the exit buon as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Closed.
Door Opening Timeout Alarm Threshold
An alarm will be triggered if the door has not been closed within the congured me duraon.
Door Magnec Sensor Type
You can set the Door Magnec Sensor Type as Remain Open or Remain Closed according to
your actual needs. By default, it is Remain Closed.
Door Opening
Duraon in Special Scene(s)
The door contact can be enabled with appropriate delay aer person with extended access
needs swiping her/his card.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Note
The duress code and the super code should be dierent. And the digit ranges from 4 to 8.
Set Card Security
Tap → Card Sengs to enter the sengs page.
Set the parameters and tap Save.
Enable EM Card
Enable EM card and
authencang by presenng EM card is available.
5.5.9 Upgrade and Maintenance
You can restart device, restore device parameters, and upgrade device.
Restart Device
Tap → Restart .
Tap Restart to restart the device.
Upgrade
Tap → Upgrade .
Tap Upgrade to upgrade the device.
DS-K1T809 Series Access Control Terminal User Manual
27

Note
Do not power o during the upgrading.
Restore Parameters
Tap → Default .
Restore to Default
Sengs
The device will restore to the default sengs, except for the device network parameters and
the user informaon.
Restore to Factory Sengs
All parameters will be restored to the factory sengs. You should acvate the device before
usage.
5.5.10 View Online Document
Tap → View Online Document . Tap View Online Document, you can scan the QR code with
your mobile phone for details.
DS-K1T809 Series Access Control Terminal User Manual
28

Appendix A. Legal Informaon
About this Document
●
This Document includes instrucons for using and managing the Product. Pictures, charts,
images and all other
informaon hereinaer are for descripon and explanaon only.
●
The
informaon contained in the Document is subject to change, without noce, due to
rmware updates or other reasons. Please nd the latest version of the Document at the
Hikvision website ( hps://www.hikvision.com ). Unless otherwise agreed, Hangzhou Hikvision
Digital Technology Co., Ltd. or its aliates (hereinaer referred to as "Hikvision") makes no
warranes, express or implied.
●
Please use the Document with the guidance and assistance of professionals trained in
supporng the Product.
About this Product
●
This product can only enjoy the aer-sales service support in the country or region where the
purchase is made.
●
If the product you choose is a video product, please scan the following QR code to obtain the
"Iniaves on the Use of Video Products", and read it carefully.
Acknowledgment of Intellectual Property Rights
●
Hikvision owns the copyrights and/or patents related to the technology embodied in the
Products described in this Document, which may include licenses obtained from third pares.
●
Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part
of this Document may be excerpted, copied, translated, or modied in whole or in part by any
means without
wrien permission.
●
and other Hikvision's trademarks and logos are the properes of Hikvision in
various
jurisdicons.
●
Other trademarks and logos menoned are the properes of their respecve owners.
LEGAL DISCLAIMER
●
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS
IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR
DS-K1T809 Series Access Control Terminal User Manual
29

IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK.
IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL,
INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR
LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR
LOSS.
●
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK,
VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE
TIMELY TECHNICAL SUPPORT IF REQUIRED.
●
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY
RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT
RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF
HUMAN RIGHTS ABUSES.
●
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS DOCUMENT AND THE APPLICABLE LAW, THE
LATTER PREVAILS.
Data
Protecon
●
To protect data, the development of Hikvision Products incorporates privacy by design
principles. For example, for Products with facial
recognion features, biometrics data is stored in
your Products with encrypon method; for ngerprint Products, only ngerprint template will be
saved, which is impossible to reconstruct a
ngerprint image.
●
As a data controller/processor, you may process personal data, including collecon, storage, use,
processing, disclosure,
deleon, etc. You are advised to pay aenon to and comply with
applicable laws and regulaons related to the protecon of personal data, including without
limitaon, conducng security controls to safeguard personal data, such as, implemenng
reasonable administrave and physical security controls, conduct periodic reviews and the
assessments of the
eecveness of your security controls.
© Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
DS-K1T809 Series Access Control Terminal User Manual
30

Appendix B. Symbol Convenons
The symbols that may be found in this document are dened as follows.
Symbol Descripon
Danger
Indicates a hazardous situaon which, if not avoided, will or could
result in death or serious injury.
Cauon
Indicates a potenally hazardous situaon which, if not avoided, could
result in equipment damage, data loss, performance degradaon, or
unexpected results.
Note
Provides addional informaon to emphasize or supplement
important points of the main text.
DS-K1T809 Series Access Control Terminal User Manual
31

Appendix C. Dimension
Figure C-1 Dimension
Note
The pictures here are for reference only.
DS-K1T809 Series Access Control Terminal User Manual
32

UD39498B