Hikvision DS-K1T809MWX Value Card Terminal

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Installation Instruction
  • Hikvision DS-K1T809MWX Quick Start Guide - (English) Download
Specification
  • Hikvision DS-K1T809MWX Value Card Terminal Datasheet 0.38MB - (English) Download
DS-K1T809MWX photo

Hikvision DS-K1T809MWX User Manual

This is the main product document for model DS-K1T809MWX.

The file format is pdf, 42 pages, you can download this manual here .

background
DS-K1T809 Series Access Control Terminal
User Manual
background
Regulatory Informaon
FCC Informaon
Please take aenon that changes or modicaon not expressly approved by the party responsible
for compliance could void the users authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable
protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the
instrucons, may cause harmful interference to radio communicaons. However, there is
no guarantee that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television
recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the
separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit
dierent from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC
Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired
operaon.
DS-K1T809 Series Access Control Terminal User Manual
i
background
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
under the EMC Direcve 2014/30/EU, the RoHS Direcve 2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed
of as unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated
collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for specic baery informaon. The baery is marked with this
symbol, which may include
leering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the
baery to your supplier or to a designated
collecon point. For more informaon see:www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operaon is subject to
the following two condions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence.
L'exploitaon est autorisée aux deux condions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2.
l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est
suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a
type and maximum (or lesser) gain approved for the
transmier by Industry Canada. To reduce
potenal radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut fonconner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intenon des
autres
ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
DS-K1T809 Series Access Control Terminal User Manual
ii
background
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et
votre corps.
DS-K1T809 Series Access Control Terminal User Manual
iii
background
Safety Instrucon
These instrucons are intended to ensure that user can use the product correctly to avoid danger
or property loss.
The
precauon measure is divided into Dangers and Cauons:
Dangers: Neglecng any of the warnings may cause serious injury or death.
Cauons: Neglecng any of the cauons may cause injury or equipment damage.
Dangers: Follow these safeguards to prevent
serious injury or death.
Cauons: Follow these precauons to prevent
potenal injury or material damage.
Dangers
All the electronic operaon should be strictly compliance with the electrical safety regulaons,
re prevenon regulaons and other related regulaons in your local region.
Please use the power adapter, which is provided by normal company. The power consumpon
cannot be less than the required value.
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or
re hazard.
Please make sure that the power has been disconnected before you wire, install or dismantle the
device.
When the product is installed on wall or ceiling, the device shall be
rmly xed.
If smoke, odors or noise rise from the device, turn
o the power at once and unplug the power
cable, and then please contact the service center.
Do not ingest baery, Chemical Burn Hazard.
This product contains a
coin/buon cell baery. If the coin/buon cell baery is swallowed, it
can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used
baeries away from children. If the baery compartment does not close
securely, stop using the product and keep it away from children. If you think baeries might have
been swallowed or placed inside any part of the body, seek immediate medical
aenon.
If the product does not work properly, please contact your dealer or the nearest service center.
Never
aempt to disassemble the device yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
Cauons
This equipment is not suitable for use in locaons where children are likely to be present.
Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnesm radiaon. Avoid the equipment installaon on vibraons surface or places
subject to shock (ignorance can cause equipment damage).
DS-K1T809 Series Access Control Terminal User Manual
iv
background
Do not place the device in extremely hot (refer to the specicaon of the device for the detailed
operang temperature), cold, dusty or damp locaons, and do not expose it to high
electromagnec radiaon.
The device cover for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or
radiator is forbidden (ignorance can cause
re danger).
Do not aim the device at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a
malfuncon however), and aecng the endurance of sensor at the
same
me.
Please use the provided glove when open up the device cover, avoid direct contact with the
device cover, because the acidic sweat of the ngers may erode the surface coang of the device
cover.
Please use a
so and dry cloth when clean inside and outside surfaces of the device cover, do
not use alkaline detergents.
Please keep all wrappers aer unpack them for future use. In case of any failure occurred, you
need to return the device to the factory with the original wrapper.
Transportaon without the
original wrapper may result in damage on the device and lead to addional costs.
Improper use or replacement of the
baery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used baeries according to the instrucons provided by
the
baery manufacturer.
You can view the device License via the website: hp://opensource.hikvision.com/Home/List?
id=46
.
DS-K1T809 Series Access Control Terminal User Manual
v
background
Available Models
The access control terminal contains the following models:
Product Name Model
Access Control Terminal DS-K1T809MWX
DS-K1T809EWX
DS-K1T809 Series Access Control Terminal User Manual
vi
background
Contents
Chapter 1 Appearance ................................................................................................................ 1
Chapter 2 Installaon ................................................................................................................. 2
2.1 Installaon Environment ........................................................................................................ 2
2.2 Surface Mounng .................................................................................................................. 2
Chapter 3 Device Wiring ............................................................................................................. 6
3.1 External Device Wiring ........................................................................................................... 6
Chapter 4 Operate on the Device ................................................................................................ 7
4.1 Common Commands ............................................................................................................. 7
4.2 Basic Commands .................................................................................................................... 8
4.2.1
Acvaon ...................................................................................................................... 8
4.2.2 Enter and Exit Programming Mode ............................................................................... 9
4.3 Other Common Commands ................................................................................................. 10
4.3.1 Open Door .................................................................................................................. 10
4.3.2 Set
Funconal Card ..................................................................................................... 11
4.4 Advanced Commands .......................................................................................................... 12
4.4.1 Set Door Parameters ................................................................................................... 12
4.4.2 Set Voice Parameters .................................................................................................. 13
4.4.3 Set NFC ........................................................................................................................ 13
4.4.4 Set Card Reader Wiegand Mode ................................................................................. 13
4.4.5 Restore to Default
Sengs ......................................................................................... 13
4.4.6 Restart Device ............................................................................................................. 14
4.4.7 Restore to Factory
Sengs ......................................................................................... 14
Chapter 5 Congure the Device via the Mobile Web ................................................................. 15
5.1
Acvate via Mobile Web ...................................................................................................... 15
5.2 Login .................................................................................................................................... 15
5.3 Quick Operaon via Web Browser ....................................................................................... 16
DS-K1T809 Series Access Control Terminal User Manual
vii
background
5.3.1 Time Sengs ............................................................................................................... 16
5.4 Overview .............................................................................................................................. 16
5.5
Conguraon ....................................................................................................................... 17
5.5.1 View Device Informaon ............................................................................................. 17
5.5.2 Time Sengs ............................................................................................................... 17
5.5.3 Set DST ........................................................................................................................ 19
5.5.4 Change Administrator's Password on Mobile Web ..................................................... 19
5.5.5 Network Sengs ......................................................................................................... 20
5.5.6 User Management ...................................................................................................... 21
5.5.7 Search Event ................................................................................................................ 23
5.5.8 Access Control Sengs ............................................................................................... 23
5.5.9 Upgrade and Maintenance ......................................................................................... 27
5.5.10 View Online Document ............................................................................................. 28
Appendix A. Legal Informaon ................................................................................................. 29
Appendix B. Symbol Convenons ............................................................................................. 31
Appendix C. Dimension ............................................................................................................ 32
DS-K1T809 Series Access Control Terminal User Manual
viii
background
Chapter 1 Appearance
Refer to the following contents for detailed informaon of the access control terminal:
Figure 1-1 Access Control Terminal
Note
The pictures here are for reference only.
DS-K1T809 Series Access Control Terminal User Manual
1
background
Chapter 2 Installaon
2.1 Installaon Environment
The minimum bearing weight of the wall or other places should be 3 mes heavier than the
device weight.
• Please prepare the following tools and accessories: screwdriver (self purchased), screws,
cables, and adapters (self purchased).
2.2 Surface Mounng
Steps
1.
Aach the installaon scker to the wall about 1.45 m from the ground or the locaon where
the device needs to be installed, and punch the hole according to the hole
locaon (hole 1 and
hole 2) on the scker and wall.
Figure 2-1 Installaon Scker
2.
Insert the plasc sleeve of the provided expansion screw into the punched hole.
DS-K1T809 Series Access Control Terminal User Manual
2
background
Figure 2-2 Insert Plasc Sleeve
3.
Make sure the cables are threaded through the hole.
Figure 2-3 Thread Cables
4.
Secure the mounng plate on the gang box with two supplied screws (PA4X25-SUS).
DS-K1T809 Series Access Control Terminal User Manual
3
background
Figure 2-4 Secure Mounng Plate
5.
Complete the wiring. See the wiring diagram for details.
Figure 2-5 Complete Wiring
6.
Hang the device into the plate from top to boom. Secure the device on the mounng plate
with 1 supplied screw (SC-KM3X6-T10-SUS).
DS-K1T809 Series Access Control Terminal User Manual
4
background
Figure 2-6 Secure Device
DS-K1T809 Series Access Control Terminal User Manual
5
background
Chapter 3 Device Wiring
3.1 External Device Wiring
Wire the external device.
The wiring diagram is as follows.
Figure 3-1 External Device Wiring
Note
Use a DC 12 V power supply. Do not connect the device directly to the 220 V mains.
The suggested external power supply for door lock is 12 V, 1 A.
DS-K1T809 Series Access Control Terminal User Manual
6
background
Chapter 4 Operate on the Device
4.1 Common Commands
Table 4-1 Common Commands Descripon
Module Operaon Command Descripon
Acvate Device Acvate [*][0][#] [Programming
Password (6 to 8
Digits )] [Repeat
Programming
Password (6 to 8
Digits) ] [#]
The 6 to 8 digits
programming
password cannot all be
0.
Programming Mode Enter Programming
Mode
[Programming
Password (6 to 8
Digits )] [*][0][#]
/
Go back to
Programming Mode
[*] /
Exit Programming
Mode
[*] [#] The device will
automacally exit the
programming mode
aer 30s of no
operaon.
Change Programming
Password
[00] [New
Programming
Password (6 to 8
Digits )] [Repeat New
Programming
Password (6 to 8
Digits) ] [#]
/
Add Door Opening
Credenal
Set Door Opening
Password
[03] [Door Opening
Password (4 to 8
Digits )] [Repeat Door
Opening Password (4
to 8 Digits) ] [#]
/
Add User Card [01] [User Code (4
Digits )](Oponal)
[Swipe Card]...
If you choose to add a
user code, you can
DS-K1T809 Series Access Control Terminal User Manual
7
background
Module Operaon Command Descripon
save the added card to
the user code locaon.
Delete User Card [02] [Swipe Card]... /
Add User Cards in
Batch
[01] [User Code (4
Digits )](Oponal)
[Swipe Card 1][Swipe
Card 2][Swipe Card
3]...
/
Delete User Cards in
Batch (Method 1)
[02] [Swipe Card 1]
[Swipe Card 2][Swipe
Card 3]...
/
Delete User Cards in
Batch (Method 2)
[15] [Programming
Password (6 to 8
Digits )] [#]
/
Delete User Code [02] [User Code] [#] /
Delete User Codes in
Batch
[02] [User Code] [#]
[User Code] [#]...
/
4.2 Basic Commands
The device needs to be acvated before it can be used. Aer acvang, the device can be at two
modes: normal mode and programming mode. Aer entering programming mode, the device can
be operated by commands.
4.2.1
Acvaon
Command
Acvate: [*][0][#] [Programming Password (6 to 8 Digits )] [Repeat Programming Password (6 to 8
Digits) ] [#].
Note
The 6 to 8 digits programming password cannot all be 0.
DS-K1T809 Series Access Control Terminal User Manual
8
background
Prompts Descripon
Indicator Prompt Audio Descripon
Light is solid green. The buzzer rings for 3 s. Acvated , and in normal mode
(not programming mode).
Light ashes red slowly for 3
mes.
The buzzer rings for 5 mes
quickly.
Acvang failed.
Light ashes orange slowly. / Inacvated
4.2.2 Enter and Exit Programming Mode
There are two ways to enter the programming mode: enter the command , or directly swipe the
funconal card (including management card, adding card and deleng card).
Programming Mode Command
Enter Programming Mode: [Programming Password (6 to 8 Digits )] [*][0][#].
Exit Programming Mode: [*] [#].
Change Programming Password: [00] [New Programming Password (6 to 8 Digits )] [Repeat New
Programming Password (6 to 8 Digits) ] [#].
Table 4-2 Prompts
Descripon
Indicator Prompt Audio Descripon
Light is solid green for 2 s. The buzzer rings 2 mes quickly. Enter Programming Mode
Light is solid red for 2 s. The buzzer rings 3 mes slowly. Entering Programming Mode failed
/ The buzzer beeps 1 sound. Swipe Card and Press Buon Prompt
Audio
/ The buzzer rings 2 mes. Exit due to meout.
Note
Aer 5 consecuve programming password input errors, the device will enter a locked status.
Aer waing for 1800 s or aer the device losing power me cleared, you can enter the
programming password again to enter the programming mode. Enter the programming
password in the locked status, the indicator will be solid orange for 2 s, and the buzzer will ring 5
mes quickly, indicang that it cannot enter the programming mode.
In programming mode, "*" represents a fallback to programming mode without entering a
command, and "# "Indicates the end or compleon of a command.
In programming mode, you need to press "*" to exit the batch
addion and deleon mode.
DS-K1T809 Series Access Control Terminal User Manual
9
background
Swipe Funconal Card
Aer swiping the funconal card in the card swiping area, you can directly enter the programming
mode. See Set Funconal Card for adding details.
4.3 Other Common Commands
4.3.1 Open Door
There are two ways to open door: enter the password, or swipe user card.
Prompts
Descripon
Indicator Prompt Audio Descripon
Light is solid green for 2 s. The buzzer rings 2 mes quickly. Authencated
Light is solid red for 2 s. The buzzer rings 3 mes slowly. Authencaon failed.
/ The buzzer beeps 1 sound. Swipe Card and Press Buon Prompt
Audio
/ The buzzer rings 2 mes. Exit due to meout.
Set Door Opening Password
You can set the door opening password and open door by entering the door opening password.
Command
Command of Seng Door Opening Password: [03] [Door Opening Password (4 to 8 Digits )]
[Repeat Door Opening Password (4 to 8 Digits) ] [#].
Note
The 4 to 8 door opening password cannot all be 0. If all of them are 0, the door opening password
funcon will be disabled.
Add/Delete User Card
Command
Add User Card: [01] [User Code (4 Digits)] (Oponal)[Swipe Card ]...
DS-K1T809 Series Access Control Terminal User Manual
10
background
Add User Card in Batch:[01] [User Code (4 Digits )](Oponal) [Swipe Card 1][Swipe Card 2][Swipe
Card 3]...
Note
If you enter a user code before adding a card, the locaon of the added user card is under this
code ID, and if you do not enter the user code, the added card has no xed posion.
The user code format is 4 digits and the range is from1 to 1000. If the entered code content and
format is incorrect, the
addion fails, and the current adding command ends.
Delete User Code: [02] [User Code] [#].
Delete User Code in Batch: [02] [User Code] [#][User Code] [#]...
Delete User Card: [02] [Swipe Card].
Delete User Card in Batch (Method 1): [02] [Swipe Card 1] [Swipe Card 2][Swipe Card 3]...
Delete User Card in Batch (Method 2): [15] [Programming Password (6 to 8 Digits )] [#].
4.3.2 Set
Funconal Card
Funconal cards include management card, adding card and deleng card.
Note
Funconal cards cannot be used to open door, but are only equivalent to a certain command.
Management Card
Swipe the management card in the standby status: it means that the device directly enters the
programming mode, and there is no need to enter the command to enter the programming mode.
Command of Adding Management Card: [04] [Swipe Card].
Command of
Deleng Management Card: [05][#].
Command of Adding Management Card, Adding Card and Deleng Card at Once: [10] [Swipe
Management Card][Swipe Adding Card] [Swipe
Deleng Card].
Note
Aer swiping the management card to enter the programming mode, if the device is not operated
for 30 s, it will exit programming mode. Swipe twice in 3 seconds to switch door contact sengs.
When switching the door contact, the buzzer ringing 8 mes slowly means that the mode is
switched to remain closed, and the buzzer ringing 8
mes quickly means that the mode is switched
to remain open.
Adding Card
Swipe the adding card in the standby status: it means that the device directly enters the
programming mode, and enters the [01] command (adding command).
For example, if you need to add a user card, you can swipe the adding card and then swipe a user
card when the device is in standby status.
DS-K1T809 Series Access Control Terminal User Manual
11
background
Command of Adding Adding Card: [06] [Swipe Card].
Command of Deleng Adding Card: [07][#].
Note
Aer swiping the adding card to enter the programming mode, if the device is not operated for 30
s, it will exit programming mode.
Delete Card
Swipe the deleng card in the standby status: it means that the device directly enters the
programming mode, and enters the [02] command (deleng command).
For example, if you need to delete a user card, you can swipe the
deleng card and then swipe a
user card when the device is in standby status.
Command of Adding Deleng Card: [08] [Swipe Card].
Command of
Deleng Deleng Card: [09][#].
Note
Aer swiping the deleng card to enter the programming mode, if the device is not operated for
30 s, it will exit programming mode.
4.4 Advanced Commands
4.4.1 Set Door Parameters
The door opening me, door opening meout, door contact type and exit buon type can be set
by command.
Command: [11] [Data Bit 1] [Data Bit 2] [Data Bit 3] [Data Bit 4] [#].
Data Bit 1: Indicates the door opening
me, which is a three digits number from 000 to 255. The
unit is second. If the door opening
me is 3 s, the data bit 1 is set to 003. The default door opening
me is 5 s.
Data Bit 2: Indicates the door opening
meout, which is a two digits number. The unit is second. If
the door is opened beyond this seng me, the device will alarm and ring for 10 s. If you enter
"50", the alarm me for door opening meout will be 50 s. The default door opening meout is 30
s.
Data Bit 3: Indicates the type of door contact, which is a one digit number. "0" means remaining
closed, and "1" means remaining open. It is remaining closed by default.
Data Bit 4: Indicates the type of exit
buon, which is a one digit number. "0" means remaining
closed, and "1" means remaining open. It is remaining closed by default.
DS-K1T809 Series Access Control Terminal User Manual
12
background
4.4.2 Set Voice Parameters
You can set whether to enable the buon sound and authencaon prompt audio through the
command.
Command: [12] [Data Bit 1] [Data Bit 2] [#].
Data Bit 1: Indicates whether to enable the
buon sound, which is a one digit number. "0" means
the
buon sound is disabled, and "1" means the buon sound is enabled. It is enabled by default.
Indicates whether to enable the
authencaon prompt audio, which is a one digit number. "0"
means the
authencaon prompt audio is disabled, and "1" means the authencaon prompt
audio is enabled. It is enabled by default.
Note
The disabling only takes eect in the normal mode, not in the programming mode.
4.4.3 Set NFC
You can set whether to enable NFC funcon through the command.
Command: [13] [Data Bit 1] [#].
Data Bit 1: “0" means disabling NFC
funcon, and "1" means enabling NFC funcon. It is enabled
by default.
Note
Only some models support this funcon, please refer to the actual product.
4.4.4 Set Card Reader Wiegand Mode
The Wiegand mode of card reader can be set by command.
Command: [14] [Data Bit 1] [#].
Data Bit 1: "0" means Wiegand 26 mode, and "1" means Wiegand 34 mode. The default mode is
Wiegand 34.
4.4.5 Restore to Default
Sengs
You can perform commands or press buon to restore to default sengs.
Command 1: [16] [Programming Password (6 to 8 Digits )]] [#] (Only Restore Data Except User
Cards Data).
Command 2: Press and hold the "*"
buon for 5 seconds within 30 seconds of powering on.
DS-K1T809 Series Access Control Terminal User Manual
13
background
4.4.6 Restart Device
You can restart the device by command.
Command: [17] [Programming Password (6 to 8 Digits )] [#].
4.4.7 Restore to Factory Sengs
You can restore the device to factory sengs by command.
Command: [18] [Programming Password (6 to 8 Digits )]] [#] (Restore All User and Default Data).
DS-K1T809 Series Access Control Terminal User Manual
14
background
Chapter 5 Congure the Device via the Mobile Web
The device supports acvaon and operaon through device-side commands. It also supports
acvaon and operaon on the mobile phone by connecng to the device hotspot. (If it is
acvated through the mobile phone, it cannot be operated through the device. If it is acvated
through the device, you can operate on the mobile phone.
5.1 Acvate via Mobile Web
You can acvate the device via mobile web.
Steps
1.
Aer the device is powered on, the hotspot is enabled by default. Search for and connect to the
device hotspot on your phone.
Note
Device hotspot name is AP_ Serial No., and inial password of device hotspot is Serial No.
Aer restarng or switching from non-AP mode to AP mode aer acvaon (press and hold
the number buon 5 to switch AP mode), the hotspot password will be changed to the
acvaon password.
You can log in to the mobile web client only when the device is in AP mode.
2.
Open the browser address bar of the mobile phone and enter 192.168.8.1 to enter the
acvaon interface.
3.
Set the
acvaon password and conrm it.
Note
The password must be 8 to 16 characters long.
The password must be composed of two or more combinaons of numbers, lowercase leers,
uppercase leers, and special characters.
The password cannot contain the user name, 123, admin, 4 or more
consecuve digits in
increments or decrement, or the same symbol.
4.
Tap Acvate Device.
5.2 Login
You can log in via mobile browser.
Note
Parts of the device models support this funcon.
Make sure the device is acvated.
DS-K1T809 Series Access Control Terminal User Manual
15
background
Enter the device IP address in the address bar of the mobile browser and press Enter to enter the
login page.
Enter the device user name and the password. Tap Login.
5.3 Quick Operaon via Web Browser
5.3.1 Time Sengs
You can set the me zone, me synchronizaon mode, and the displayed me.
Device Time
Display the device me in real me.
Time Zone
Select the device located me zone from the drop-down list.
Time Synchronizaon Mode
NTP
You should set the NTP server's IP address, port No., and interval.
Manual
By default, the device
me should be synchronized manually. You can set the device me
manually or check Sync. with Phone Time to synchronize the device me with the phone's
me.
DST
You can enable DST, set and view the DST start
me, end me and bias me.
Click Next to save the sengs.
5.4 Overview
You can view the door status, network status and basic informaon, and set person management,
authencaon sengs, and door parameters via shortcut entry.
Funcon Descripons:
Door Status
/ / /
The door status is open/closed/remaining open/remaining closed. You can tap to select
open/closed/remaining open/remaining closed status according to your actual needs.
Shortcut Entry
You can set person management, authencaon sengs, and door parameters via shortcut
entry.
DS-K1T809 Series Access Control Terminal User Manual
16
background
Network Status
You can view the connected status of wireless network and Hik-Connect.
Basic Informaon
You can view the model, serial No. and rmware version.
5.5 Conguraon
5.5.1 View Device Informaon
View the device name, language, model, serial No., version, number of channels, IO input number,
number of alarm input and output, Mac address, factory
informaon and device capacity, etc.
Tap → System Sengs → Basic Informaon to enter the conguraon page.
You can view the device name, language, model, serial No., version, number of channels, IO input
number, number of alarm input and output, Mac address, factory
informaon and device capacity,
etc.
5.5.2 Time
Sengs
Set the me zone, me sync. mode, and displayed me.
Tap → System Sengs → Time Sengs to enter the sengs page.
DS-K1T809 Series Access Control Terminal User Manual
17
background
Figure 5-1 Time Sengs
Tap Save to save the sengs.
Time Zone
Select the me zone where the device is located from the drop-down list.
Time Sync. Mode
Manual
You can set the device me manually, or enable Sync. with Phone Time.
NTP
DS-K1T809 Series Access Control Terminal User Manual
18
background
Set the NTP server's IP address, port No., and interval.
5.5.3 Set DST
Steps
1.
Tap
→ System Sengs → Time Sengs , to enter the sengs page.
Figure 5-2 DST
2.
Tap Enable DST.
3.
Set the start
me, end me, and DST bias.
4.
Tap Save.
5.5.4 Change Administrator's Password on Mobile Web
You can change administrator's password.
Steps
1.
Tap → User Management → admin to enter the sengs page.
2.
Enter the old password and create a new password.
3.
Conrm the new password.
4.
Tap Save.
Note
The password strength of the device can be automacally checked. We highly recommend you
change the password of your own choosing (using 8 to 16 characters, including at least two kinds
of following characters: upper case leers, lower case leers, numbers, and special characters,
and do not contain following characters in the password: the user name, 123, admin (case
insensive), 4 or more connuously increasing or decreasing digits, or 4 or more consecuvely
repeated characters) in order to increase the security of your product. We recommend you
DS-K1T809 Series Access Control Terminal User Manual
19
background
change your password regularly, especially in the high security system, changing the password
monthly or weekly can beer protect your product.
5.5.5 Network Sengs
Set Device Hotspot
Set the device hotspot, and mobile phone can connect to the device to enter the mobile browser.
Steps
1.
Tap → Network Sengs → Device Hotspot .
2.
You can enable device hotspot and view the hotspot name.
Note
By default, the hotspot name is the AP_Device Serial No.
3.
Tap Save.
Plaorm
Access
Plaorm access provides you an opon to manage the devices via plaorm.
Steps
1.
Tap → Device Access → Hik-Connect to enter the sengs page.
Note
Hik-Connect is an applicaon for mobile devices. With the App, you can view live image of the
device, receive alarm nocaon and so on.
2.
Check Enable to enable the funcon.
3.
You can view Network Connecon Status and Account Linkage Status.
4.
Tap Save to enable the
sengs.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1.
Tap
→ Access Conguraon → Wiegand Sengs .
DS-K1T809 Series Access Control Terminal User Manual
20
background
Figure 5-3 Wiegand Page
2.
Enable Wiegand to enable the Wiegand funcon.
3.
Set a transmission direcon.
Note
The device can connect an external access controller. And the two devices will transmit the card
No. via Wiegand 26 or 34.
4.
Tap More, and you can set Time Interval and Pulse Width.
5.
Tap Save to save the
sengs.
5.5.6 User Management
You can add, edit, delete, and search users via mobile Web browser.
Steps
1.
Tap → Person Management to enter the sengs page.
DS-K1T809 Series Access Control Terminal User Manual
21
background
Figure 5-4 User Management
2.
Add user.
1) Tap+.
2) Set the following parameters.
Employee No.
Enter the employee No. The Employee No. cannot be 0 or exceed 32 characters. It can be a
combinaon of uppercase leers, lowercase leers and numbers.
Name
Enter your name. The name supports numbers, English uppercase and lowercase leers
and Chinese characters. The name is recommended to be within 32 characters.
Long-Term Eecve User
DS-K1T809 Series Access Control Terminal User Manual
22
background
Set the user permission as long-term eecve, or set the start date and end date of user
permission.
User Type
Select your user role.
Card
Add card. Tap Card, then tap +. Enter the card No. or swipe the card to read card No., and
then select Card Type.
3) Tap Save.
3.
Oponal: Tap the user that needs to be edited in the user list to edit the informaon.
4.
Oponal: Tap the user that needs to be deleted in the user list, and tap to delete the user.
5.
Oponal: You can search the user by entering the employee ID in the search bar.
5.5.7 Search Event
Tap → Search to enter the page.
Enter the search
condions, including the event type, major type, sub type, employee No., card
No., start me, and end me, and tap Search.
Note
Support searching for names within 32 digits.
5.5.8 Access Control Sengs
Set Authencaon Parameters
Set Authencaon Parameters.
Steps
1.
Tap → Access Control Authencaon Sengs .
DS-K1T809 Series Access Control Terminal User Manual
23
background
Figure 5-5 Set Authencaon Parameters
2.
Tap Save.
Terminal
Select the terminal.
Authencaon Type
Select an authencaon type according to your actual needs from the drop-down list.
Authencaon Interval
You can set the authencaon interval of the same person when authencang. The same
person can only authencate once in the congured interval. A second authencaon will be
failed.
Max. Authencaon Failed Aempts Alarm/Max. Authencaon Failed Aempts
Aer you enable Max. Authencaon Failed Aempts Alarm, you can set Max.
Authencaon Failed Aempts. The device will automacally generate and report alarm
events aer the authencaon failures exceed the congured aempts.
DS-K1T809 Series Access Control Terminal User Manual
24
background
Max. Interval When Entering Password
You can set the Max. meout period for password entry, aer which the password input will
be invalid.
Enable Card No. Reversing
If this funcon is enabled, the card reader will reverse the order of the card No. aer reading
them.
Set Door Parameters
Tap → Access Control → Door Parameters .
DS-K1T809 Series Access Control Terminal User Manual
25
background
Figure 5-6 Door Parameters Sengs
Tap Save to save the sengs aer the conguraon.
Door Name
You can create a name for the door.
Door Opening Duraon(s)
Set the door open duraon.
Exit Buon Type
DS-K1T809 Series Access Control Terminal User Manual
26
background
You can set the exit buon as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Closed.
Door Opening Timeout Alarm Threshold
An alarm will be triggered if the door has not been closed within the congured me duraon.
Door Magnec Sensor Type
You can set the Door Magnec Sensor Type as Remain Open or Remain Closed according to
your actual needs. By default, it is Remain Closed.
Door Opening
Duraon in Special Scene(s)
The door contact can be enabled with appropriate delay aer person with extended access
needs swiping her/his card.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Note
The duress code and the super code should be dierent. And the digit ranges from 4 to 8.
Set Card Security
Tap → Card Sengs to enter the sengs page.
Set the parameters and tap Save.
Enable EM Card
Enable EM card and
authencang by presenng EM card is available.
5.5.9 Upgrade and Maintenance
You can restart device, restore device parameters, and upgrade device.
Restart Device
Tap → Restart .
Tap Restart to restart the device.
Upgrade
Tap → Upgrade .
Tap Upgrade to upgrade the device.
DS-K1T809 Series Access Control Terminal User Manual
27
background
Note
Do not power o during the upgrading.
Restore Parameters
Tap → Default .
Restore to Default
Sengs
The device will restore to the default sengs, except for the device network parameters and
the user informaon.
Restore to Factory Sengs
All parameters will be restored to the factory sengs. You should acvate the device before
usage.
5.5.10 View Online Document
Tap → View Online Document . Tap View Online Document, you can scan the QR code with
your mobile phone for details.
DS-K1T809 Series Access Control Terminal User Manual
28
background
Appendix A. Legal Informaon
About this Document
This Document includes instrucons for using and managing the Product. Pictures, charts,
images and all other
informaon hereinaer are for descripon and explanaon only.
The
informaon contained in the Document is subject to change, without noce, due to
rmware updates or other reasons. Please nd the latest version of the Document at the
Hikvision website ( hps://www.hikvision.com ). Unless otherwise agreed, Hangzhou Hikvision
Digital Technology Co., Ltd. or its aliates (hereinaer referred to as "Hikvision") makes no
warranes, express or implied.
Please use the Document with the guidance and assistance of professionals trained in
supporng the Product.
About this Product
This product can only enjoy the aer-sales service support in the country or region where the
purchase is made.
If the product you choose is a video product, please scan the following QR code to obtain the
"Iniaves on the Use of Video Products", and read it carefully.
Acknowledgment of Intellectual Property Rights
Hikvision owns the copyrights and/or patents related to the technology embodied in the
Products described in this Document, which may include licenses obtained from third pares.
Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part
of this Document may be excerpted, copied, translated, or modied in whole or in part by any
means without
wrien permission.
and other Hikvision's trademarks and logos are the properes of Hikvision in
various
jurisdicons.
Other trademarks and logos menoned are the properes of their respecve owners.
LEGAL DISCLAIMER
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS
IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR
DS-K1T809 Series Access Control Terminal User Manual
29
background
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK.
IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL,
INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR
LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR
LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK,
VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE
TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY
RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT
RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF
HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS DOCUMENT AND THE APPLICABLE LAW, THE
LATTER PREVAILS.
Data
Protecon
To protect data, the development of Hikvision Products incorporates privacy by design
principles. For example, for Products with facial
recognion features, biometrics data is stored in
your Products with encrypon method; for ngerprint Products, only ngerprint template will be
saved, which is impossible to reconstruct a
ngerprint image.
As a data controller/processor, you may process personal data, including collecon, storage, use,
processing, disclosure,
deleon, etc. You are advised to pay aenon to and comply with
applicable laws and regulaons related to the protecon of personal data, including without
limitaon, conducng security controls to safeguard personal data, such as, implemenng
reasonable administrave and physical security controls, conduct periodic reviews and the
assessments of the
eecveness of your security controls.
© Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
DS-K1T809 Series Access Control Terminal User Manual
30
background
Appendix B. Symbol Convenons
The symbols that may be found in this document are dened as follows.
Symbol Descripon
Danger
Indicates a hazardous situaon which, if not avoided, will or could
result in death or serious injury.
Cauon
Indicates a potenally hazardous situaon which, if not avoided, could
result in equipment damage, data loss, performance degradaon, or
unexpected results.
Note
Provides addional informaon to emphasize or supplement
important points of the main text.
DS-K1T809 Series Access Control Terminal User Manual
31
background
Appendix C. Dimension
Figure C-1 Dimension
Note
The pictures here are for reference only.
DS-K1T809 Series Access Control Terminal User Manual
32
background
UD39498B

Specifications

Hikvision DS-K1T809MWX Questions and Answers