Beverage-Air HRPS3HC-1S Horizon Series 78" Stainless Steel Reach-In Refrigerator

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction Other Documents
  • HRPS3HC-1S Specsheet - (English) Download
  • Back Spacer Instructions - (English) Download
  • Bev-2025-Product-Overview-20250428 Extra Product Overview - (English) Download
HRPS3HC-1S photo

809-144A MANUAL_INSTALLATION AND OPERATION BEV AIR HR

This is the main product document for model HRPS3HC-1S. Additionally, the document applies to other Beverage-Air models: 185HRPS3HCS

The file format is pdf, 28 pages, you can download this manual here .

background
INSTALLATION AND OPERATING INSTRUCTIONS
for all Hydrocarbon
HR Refrigerator Models
3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105
Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.com
809-144A Rev F. 04/28/2025
SEE BACK COVER FOR
WARRANTY REGISTRATION
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air2
WELCOME
Contents
Welcome ................................................................................................................................................................... 2
Safety ........................................................................................................................................................................ 3
Important Information .......................................................................................................................................... 5
Product Information .............................................................................................................................................. 6
Clearance and Placement ......................................................................................................................................7
Unpacking and Set Up ........................................................................................................................................... 8
Shelf Installation ..................................................................................................................................................... 9
Electrical ..................................................................................................................................................................10
Using The Unit - Danfoss Controller .................................................................................................................. 11
Sequence of Operations Refrigerator......................................................................................................12
Using The Unit - Eliwell Controller ....................................................................................................................16
Sequence of Operations Refrigerator......................................................................................................17
Cleaning and Maintenance ................................................................................................................................20
Condenser Cleaning ...............................................................................................................................................21
Methods For Cleaning Stainless Steel.............................................................................................................22
Help .......................................................................................................................................................................... 23
For The Service Tech - R290 .............................................................................................................................24
For The Service Tech - Wiring Diagram ........................................................................................................... 25
Limited Warranty .................................................................................................................................................26
Limited Warranty (continued) ........................................................................................................................... 27
Important Information
PLEASE READ THESE INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR USING, IF RECOMMENDED
PROCEDURES ARE NOT FOLLOWED, WARRANTY
CLAIMS MAY BE DENIED.
Your warranty registration information is located with
this manual. Please complete the card and submit it to
Beverage-Air within TEN days of installation. Failure
to properly register equipment may limit or void the
warranty.
Beverage-Air reserves the right to change
specications and product design without
notice. Such revisions do not entitle the buyer to
corresponding changes, improvements, additions, or
replacements for previously purchased equipment.
Thank you for purchasing a Beverage-Air cabinet. This
series has passed our strict quality control inspection and
meets the high standards set by Beverage-Air! You have
made a quality investment that with proper maintenance
will give you many years of reliable service!
Please read the following installation and maintenance
instructions before installing or using your unit.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 3
SAFETY
This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However,
safe operation and maintenance are your responsibilities.
Use: When using this unit, please:
Move it carefully. If on casters be sure the casters
do NOT run over the power cord.
Lock the casters when in use.
Seek help. This machine is heavy! Be sure to move
with enough help to avoid tipping or dropping the
cabinet.
Prevent children from playing in or on the cabinet.
Persons unable to use this product must be
prevented access.
Follow all instructions. There are many safety
labels and directions on the unit. Heed them.
Watch your ngers. There may be pinch points near
the door hinges.
Maintenance
Do NOT:
Clean a frozen evaporator with a sharp object
Clean a dirty condenser with a sharp object.
Store gasoline, kerosene or any other ammable
material near the cabinet.
Do ALWAYS
Use a Beverage-Air recommended technician certied
to repair R290 equipment.
Use ONLY Beverage-Air factory service parts. Use of
non OEM parts can be dangerous because of the design
changes needed to safely use R290.
Observe the Caution and Warning notices. They are indicators of
important safety information. Keep this manual for future reference.
Important Information to Add
Record the model number, serial number and the date of installation here for future reference. The model and serial
numbers are on the unit's serial number dataplate, which is located on the left inside wall.
Model Number
Serial Number
Date of Installation
Purchased From
CAUTION
WARNING
CAUTION
CAUTION
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air4
CAUTION: If it is necessary to move the Refrigerator after removal from the skid,
remove all doors and carefully push the unit at a point of no more than 36” from the
bottom to avoid damage.
CAUTION
SAFETY
Push ONLY below the 36 inch / .91 meter height
Height
will vary
by model
Do NOT push in this area.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 5
IMPORTANT INFORMATION
This unit is intended to be used in a commercial application. That includes bars and restaurants.
If installed in a residence some commercial service companies may not be able to service it on site.
The manufacturer has designed and produced this machine with the nest in materials. The manufacturer assumes no
liability for units that have been altered in any way. Alterations or part substitutions will void the warranty.
Limitations
The machine is designed for use indoors in a controlled
environment. It must be kept dry, not overheated or
subjected to excessive cold. May only be connected to
a dedicated electrical circuit. Extension cords are not
permitted.
Minimum Maximum
Voltage 103.5 126.5
Room Air Temp 60º F 100º F
Air Flow, All Models regardles of section, door count or door material.
Agency Approvals
These marks appear on the dataplate or serial tag, located
in the inside of the left wall. The dataplate also contains
the model and serial numbers as well as electrical
requirements.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air6
Base Model is HR
(Alternate Finishes -
HRP, HRS, or HRPS)
Cabinet Dimensions
w x d x h (Inches)
Half or Full
Door
Glass or
Solid Door
Full Load
Amps
Power Cord
Plug (NEMA)
Refrigerant Type /
Charge (g) / Charge oz.
HR1HC-1G 26 x 33 5/8 x 85 Full Glass
2.7
5-15P
R-290 / 110 / 3.9
HR1HC-1-HG 26 x 33 5/8 x 85 Half Glass
HR1HC-1HS 26 x 33 5/8 x 85 Half Solid
HR1HC-1S 26 x 33 3/4 x 85 Full Solid
HR1WHC-1G 35 x 33 3/4 x 85 Full Glass Wide
HR1WHC-1S 35 x 33 3/4 x 85 Full Solid Wide
HR2HC-1G 52 x 33 5/8 x 85 Full Glass
6.0
R-290 / 150 / 5.3
HR2HC-1HG 52 x 33 5/8 x 85 Half Glass
HR2HC-1HS 52 x 33 5/8 x 85 Half Solid
HR2HC-1S 52 x 33 7/8 x 85 Full Solid
HR3HC-1G 78 x 33 5/8 x 85 Full Glass
HR3HC-1HG 78 x 33 5/8 x 85 Half Glass
HR3HC-1HS 78 x 33 5/8 x 85 Half Solid
HR3HC-1S 78 x 33 7/8 x 85 Full Solid
Height includes casters.
PRODUCT INFORMATION
HF models have standard nishes - S/S front, continuous coil coated sides, aluminum interior.
HFP nish option - S/S front and sides, aluminum interior.
HFS nish option - S/S front, continuous coil coated sides, S/S interior.
HFPS nish option - complete S/S exterior and interior.
All models will maintain product temperature between 35.5 and 40.5 degrees F. at the factory setting of 38.
0
F.
All models are 115 volts, 60 Hz AC.
ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS, REFRIGERANT AND REFRIGERANT CHARGE FOR THE
MOST UP TO DATE AND ACCURATE VALUES.
There are no access valves on the refrigeration system.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 7
CLEARANCE AND PLACEMENT
Placement
Consider the following when selecting a location for your Refrigerator:
Clearance:
12 in. at the top
3.0 in. at the rear,
0.0 in. at the left side
0.0 in. at the right side
Floor Load: The oor on which the Refrigerator is located must be even and level, free from vibrations, and strong enough
to support the combined weights of the unit and maximum product load.
Ventilation: Grille area at front must be free and clear of any object or wall.
Power Outlet: Dedicated power outlet is located within the length of the unit's power cord.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air8
UNPACKING AND SET UP
CAUTION
Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is
suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
Do NOT contact the manufacturer.
Uncrating
Tools Needed: ¾” box wrench, adjustable wrench, level,
at head screw driver, and box cutter.
1. Cut the stretch wrap along a corner post and remove
the cardboard top capping and the corner posts.
2. Discard stretch wrap and any cardboard that will not
be recycled.
Note: additional clear plastic protective wrap is
applied directly to any product with a glass door.
3. Move unit as close to nal position as possible before
removing the skid.
Note: The skid must be removed before the casters or
legs can be attached.
Do NOT tip unit on its front or sides. If tipped onto the
back, unit must not be started for 3 hours.
Skid Removal and Caster Attachment
Tip the unit forward and remove the skid.
Risk of personal injury.
Unit must be securely supported
while attaching casters or legs.
WARNING
1. Remove the shipping bolts using the ¾” box wrench
while cabinet is held in one direction. Repeat the process
while the cabinet is held in the opposite direction.
2. None of the threads on the leg or caster stem should
be visible once screwed in.
3. Tilt the cabinet in one direction approximately 8” and
block it securely with pieces of 2x4 lumber or other
suitable material.
4. Thread the stem casters or legs into the ½ -13 holes in
the bottom of the cabinet. Tighten by hand as much
as possible. Some models may already have levelers
installed. If so, then the levelers will need to rst be
removed and discarded.
5. Once the caster or leg cannot be turned any further,
use a 3/4 inch wrench to tighten the nut in between
the mounting plate and the wheel of the caster until
snug.
6. Repeat this procedure with unit secured in the
opposite direction so as to access the remaining legs/
casters/levelers.
7. If plate casters or legs are installed instead of stem
casters or legs, then repeat step 3 above and secure
the plate with either #14 AB screws, or ¼-20 screws,
depending upon which are required.
8. If levelers are employed, then repeat step 3 above and
thread the leveler in place. Then repeat step 6.
Leveling:
Cabinets must be leveled when installed. Level should be
measured on the headrail.
Failure to level your cabinet may result in door not
sealing, closing correctly, or condensed water draining not
draining properly.
For cabinets with legs, rotate the foot of the leg with an
adjustable wrench to achieve desired height for leveling.
For cabinets with casters, leveling can be achieved by
placing large washers in between the ½’ stud and the
holes located on the bottom of the case.
Do NOT loosen casters to level
the cabinet. Casters MUST be
tightly secured to cabinet for full
strength.
Install or attach any accessories that will be used
Remove any plastic covering the stainless steel.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 9
1. Determine the proper location for the shelf clips.
The reference numbers on the pilaster can serve as a
guide to ensure all clips are properly located.
2. Insert the top tab of the shelf clip into the desired
hole of the pilaster. The retaining tab MUST be facing
up as shown.
3. Rotate the clip downwards and insert the bottom tab
into the matching hole in the pilaster. The clip may
need to be squeezed slightly during installation.
4. Install all remaining clips.
5. Install shelves onto clips with the product retention
bar facing up. Be careful not to dislodge clips during
installation.
6. Place shelves so that the retaining tab on the clip
captures the shelf as shown.
7. Conrm that the shelf is resting on ALL 4 clips and
that the clips are securely attached to the pilasters.
8. Improper shelf clip installation could cause the shelf
and / or the product on it to fall, resulting in damage
to the unit and possible bodily injury.
9. Do NOT overload the shelves. The unit is designed to
use all shelves that are supplied in an equally spaced
manner. Contact Beverage-Air customer service if
fewer shelves or a dierent conguration to ensure
shelf overloading will not occur.
SHELF INSTALLATION
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air10
ELECTRICAL
This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on
the machine to conrm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
Power Cord
This 115 volt model is equipped with a cord and 5-15P plug.
If the power cord becomes damaged, it must be replaced
with the identical cord.
GFCI
Units that utilize variable speed compressor technology
can experience nuisance tripping on Class A GFCI outlets
which have a trip limit of 4 to 6 mA. To avoid this
issue in a location that requires GFCI circuit protection,
Beverage-Air recommends using either an Eaton, SGF20,
or HUBBELL Model Number GFRST83W 20A Heavy Duty
Hospital Grade Self-Test GFCI Receptacle.
Follow All National and Local Codes
This unit must be grounded. Do not use extension cords
and do not disable or by-pass ground prong on electrical
plug.
Initial Start Up
Plug the power cord into the proper power supply.
The cabinet will soon begin to blow warm air out of the
top area, and cool air will ow from the inside blower.
The cabinet temperature has been set at the factory and
should not need adjustment, however if it was changed,
the standard setting is 38º F.
Cautions
Care must be taken whenever moving or servicing the
unit. The refrigerant is contained in a sealed system, but if
released it may be ammable.
After the cabinet has been installed, leveled, and cleaned
as described above, refer to the following checklist:
Check for proper electrical hook-up.
Cabinet MUST NOT SHARE A RECEPTACLE with
another piece of equipment
Check that all clearances are in line with the
aforementioned guidelines.
Check that cabinet is level.
* NOTE: Once the unit has been started and reaches proper
storage temperatures, it may be loaded with product.
Door Reversal Instructions
1. Remove hinge cover.
2. Remove door from the unit including the hinge
mounting brackets
3. Remove white hole covers from the side of the door
opening you would like the hinges to be located (do
not throw away).
4. On the bottom of the door the same hole plugs are
present and need to be removed.
5. Take the hole plugs and insert them into the screw
holes where the hinges were originally located on the
unit.
6. Install the hinge bracket upright on the unit. The
thick portion of the hinge bracket should be on the
bottom as you mount them.
7. The door portion of the hinges need to be removed
and rotated 180 degree and remounted.
8. Install the hole plugs that were removed from the
bottom of the door into the holes where the handle
was rst mounted.
9. Slide door back into position and gently lower into the
white pivot cam.
10. Replace hinge cover.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 11
38.0
o
F
USING THE UNIT - DANFOSS CONTROLLER
Operation is simple, just keep it connected to the correct
power supply and the refrigerator will maintain the
internal temperature it has been set to. Keep the doors
and / or drawers closed as much as possible to avoid
unnecessary run time.
The controller displays the current internal temperature.
Adjusting the set temperature lower will NOT cause the
system to lower the temperature faster. When on, the
refrigeration system is always operating at maximum.
The temperature was set at the factory at 38
º
F, but
you can adjust it to your own selected temperature. 30
seconds after adjustment, the display automatically
reverts to showing the current temperature.
The Refrigerator will automatically defrost as needed,
there is no set time for defrost. Push and immediately
release the "melting" or defrost button for a manual
defrost.
Note: Holding the defrost button in too long will shut the
controller o.
The internal fan will be on when the compressor is on and
when the doors are closed.
The compressor and condenser fan motor will only be on
when the controller senses an increase in internal cabinet
temperature passed the set point.
If equipped with glass doors, holding the SC button in will
turn the cabinet light on or o.
Select
Defrost
Increase
Decrease
In most cases the only thing displayed will be the cabinet temperature. When something other than normal operation has
occurred, a message will be shown.
Message Displayed Why What to do
dEF
Unit is defrosting Nothing. Normal operation.
Hi
Cabinet temperature too warm Conrm doors or drawers are closed.
dOr
Door is open Close door, if message does not
change, call for service.
LEA
Compressor run time too long Check doors closed. If yes, call for
service.
E01, E02, E03, E04
Sensor unplugged or has failed Call for service.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air12
SEQUENCE OF OPERATIONS REFRIGERATOR
The refrigerator operates based on the air temperature measured by the probe located at the return air.
ON OFF
COMPONENT OPERATION CONTROLLER ACTION OPERATION CONTROLLER ACTION
COMPRESSOR
Compressor turns
on when the air
temperature at the
probe is above the
sum of the set point
+2
The Compressor
Contact is energized
Compressor turns
o when the air
temperature at probe is
equal to or less than the
set point -2
The Compressor
Contact is de-
energized
(ERC 112 – Terminal #1)
(ERC 112 – Terminal
#1)
CONDENSER FAN
The Condenser Fan
turns on when
the Compressor is
running
The Condenser Fan
is wired directly to
the Compressor, not
through the controller
The Condenser Fan
turns o when the
Compressor is not
running
The Condenser Fan
is wired directly to
the Compressor, not
through the controller
EVAPORATOR
FAN
The Evaporator Fan
runs continuously in
refrigerators. When
the unit is plugged
in, the Evaporator
Fan will run.
The Evaporator Fan is
connected directly to
incoming power, not
through the controller.
The Evaporator Fan runs
continuously. When the
unit is plugged in, The
Evaporator Fan will run.
The Evaporator Fan is
connected directly to
incoming power, not
through the controller.
LIGHT
The light will turn on
when the is
pressed (or when the
door is opened with
solid doors)
The Light Contact is
energized
The light will turn o
when the is
pressed (or when the
door is closed with solid
doors)
The Light Contact is
de-energized
(ERC 112 – Terminal
#4)
(ERC 112 – Terminal
#4)
Condition
Compressor
Condenser Fan
Evaporator
Fan
Lights
Cabinet Temp > Set point + 2 ON ON ON ON or OFF
Cabinet Temperature <= Set point - 2 OFF OFF ON ON or OFF
Defrost OFF OFF ON ON or OFF
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 13
User Manual for UCR Refrigerators Beverage-Air
Rev. 09/21 Beverage-Air 11
DANFOSS CONTROLLER
Electronic Controller
Control Panel Display
Note: Defrost is manual, LED indicator is inoperative.
Defrost LED Alarm LED
On xed: Defrost active On xed: ALARM Present
O: Defrost is o Flashing: ALARM Silenced
O: No Alarm
Fan LED Compressor LED
On xed:
Fan active
On xed: Compressor active
O:
Fan O
Flashing: Delay, protection or activation blocked
O: No Alarm
Keyboard Functions
UP
Quick press and release
Increases Set Point
Long press and release
Increases display brightness
DOWN
Quick press and release
Decreases Set Point
Long press and release
Decreases display brightness
DEFROST (ESC)
Quick press and release
Activates manual defrost
Long press and release
Controller enter stand-by mode
SET (ENTER)
Quick press and release
Toggles lights on/o
Long press and release
Toggles display °F/°C
NOTE: When switched on, the instrument panel performs a lamp test for a few seconds.
UP
DOWN
DEFROST (ESC)
SELECT (OK)
Note: When the controller is in a Standby Mode, a blue dot
will be displayed as shown here. To switch out of Standby
Mode, push and hold the Defrost button until the display
reads ON.
.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air14
0123ÿ567869ÿ3ÿÿ9ÿ59ÿ923ÿ223623
ÿ !"!#$%!&'(#)*
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 15
0123ÿ567869ÿ3ÿÿ223623
ÿ !"#$% &'
()*+,ÿ./ÿ01023ÿ4561789:;ÿ<9348ÿ024ÿ9;ÿ=2:>2488ÿ?@A@ÿ/:1C42ÿ:/ÿ<D4ÿ=02034<42ÿ<0E14FGÿ<D4ÿ01023ÿ98ÿ;:<ÿ89>;014CH
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air16
0123ÿ567869ÿ3ÿÿ9ÿ59ÿ923ÿ223623
ÿ !"!#$%!&'(#)*
+,-./ÿ123ÿ+.-1ÿ4ÿ35-6355ÿ78.1985539
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 17
Refrigerator with Eliwell Controlle
r
Beverage-Ai
r
SEQUENCE OF OPERATIONS REFRIGERATOR
The refrigerator operates based on the air temperature measured by the probe located at the return air.
ON OFF
COMPONENT OPERATION
CONTROLLER
ACTION
OPERATION
CONTROLLER
ACTION
COMPRESSOR
Compressor turns on
when the air
temperature at the
probe is above the
sum of the set point
+ 4
The Compressor Contact
is energized
Compressor turns
off when the air
temperature at
probe is equal to
or less than the
set point
The Compressor Contact
is de-energized
(EW+978 - Terminal
#1)
(EW+978 - Terminal #1)
CONDENSER FAN
The Condenser
Fan turns on when
the Compressor is
running
The Condenser Fan is
wired directly to the
Compressor, not throu
g
h
the controller
The Condenser Fan
turns off when the
Compressor is not
running
The Condenser Fan is
wired directly to the
Compressor, not throu
g
h
the controller
EVAP FAN
The Evaporator
Fan turns on when
the unit is
powered on.
The Evaporator Fan is
wired to constant power
The Evaporator Fan
turns off when the
unit is unplugged
or put into standby.
The Evaporator Fan is
wired to constant power
Some models will be
wired to the fan relay
(EW+978 - Terminal
#3)
Some models will be
wired to the fan relay
(EW+978 - Terminal
#3)
LIGHT
The light will turn on
when the down
button is
pressed (or when the
door is opened with
solid doors)
The Light Contact is
energized
The light will turn
off when the down
button is
pressed (or when the
door is closed with
solid doors)
The Light Contact is de-
energized
(Ew+978 – Terminal #2) (Ew+978 – Terminal #2)
Condition
Compressor
Condenser
Fan
Evaporator
Fan
Lights
Cabinet Temp > Set point + 4 ON ON ON ON or OFF
Cabinet Temperature <= Set point - 4 OFF OFF ON ON or OFF
Defrost OFF OFF ON ON or OFF
Refrigerator with Eliwell Controlle
r
Beverage-Ai
r
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air18
0123ÿ567869ÿ3ÿÿ9ÿ59ÿ923ÿ223623
ÿ !"!#$%!&'(#)*
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 19
0123ÿ567869ÿ3ÿÿ9ÿ59ÿ923ÿ223623
ÿ!"!#$%!&'(#)*
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air20
CLEANING AND MAINTENANCE
Cleaning Schedule:
Cabinet
Daily wipe down
Weekly interior
Condenser coil
Quarterly cleaning
Gaskets
Daily inspection, check
that hinges are tight to
the cabinet.
Routine maintenance
Annually
Daily Exterior Cleaning
It is much easier to clean on a regular basis than to have to remove stains once they have built up.
1. Wash with a clean sponge and a mild detergent that
does not contain chlorine.
2. Rinse with clean water.
3. Dry with a soft cloth.
4. Polish with a soft cloth, wiping with the grain.
5. Wipe weekly with stainless steel cleaner.
Weekly Interior Cleaning
1. Remove all food, food related items and shelves. Store
the food at a safe temperature.
2. Disconnect power to the unit (unplug it or switch the
breaker o).
3. Remove all loose food particles from the inside walls,
oor, door liner and ceiling.
4. Scrub all interior surfaces and door gaskets with a
warm (100
o
F to 110
o
F) detergent solution and a soft
scrub brush.
5. Rinse with clean water and allow to air dry.
6. Return the shelves to the unit and secure them.
7. Restore power.
8. Return food to the unit when it has reached a
safe temperature.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 21
CONDENSER CLEANING
Keeping the condenser coil clean is critical to ecient
operation.
1. Unplug unit from power supply.
2.
Rotating fan blade can cause
personal injury.
Unplug unit from power supply
before beginning to clean
condenser
CAUTION
3. Remove two Phillips head screws from the top
corners of the front panel
4. Lift upwards on the front panel to remove
5. To reinstall the front panel line up the keeper screws
behind the panel and rmly pull downwards
6. Reinstall the screws on the top corners
7. Examine condenser surface, if dusty, brush and
vacuum the dust and lint from the surface of the
coil. Brush up and down to avoid damaging the ns.
Use care to not disturb the wires connected to the
controller.
Note: If the coil is greasy, the coil will need to be
cleaned with coil cleaner and that should be left to an
experienced technician.
8. Return grill to unit.
Note: Air lters are not recommended as they restrict
the ow of cooling air.
Remove Screws
Condenser Surface
Push Up and O
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air22
Cleaning Needed Cleaning Agent Method of Application Aect on Finish
Smears and ngerprints
Areal 20, Lac-O-Nu, Lumin Wash
O’Cedar Cream Polish, Stainless
Shine.
Rub with cloth as directed
on the package.
Satisfactory for use on all
nishes.
Provides barrier lm to
minimize prints.
Stubborn Spots and
Stains, Baked-On
Splatter, and Other
Light Discolorations
Allchem Concentrated Cleaner.
Apply with damp sponge or
cloth.
Rub with damp cloth.
Use in direction of polish lines
on No. 4 (polished) nish. May
scratch No.
2 (mill) and Nos. 7 and 8
(polished) nishes.
Samae, Twinkle or Cameo Copper
Cleaner
Rub with damp cloth.
Grade FFF Italian pumice, whiting,
or talc.
Rub with dry cloth.
Liquid NuSteel
Paste NuSteel or DuBois Temp.
Copper’s Stainless Steel Cleaner
Revere Stainless Cleaner
Household cleansers, such as
Old Dutch, Lighthouse, Sunbrite,
Wyandotte, Bab-O, Gold Dust,
Sapolio, Bon Ami, Ajax, or Comet
Grade F Italian Pumice, Steel
Bright, Lumin Cleaner, Zud,
Restore, Sta-Clean, or Highlite.
Penny-Brite or Copper-Brite.
Use small amount of cleaner.
Rub with dry cloth using a
small amount of cleaner.
Apply with damp sponge or
cloth.
Rub with a damp cloth. May
contain chlorine bleaches.
Rinse
thoroughly after use.
Rub with a damp cloth.
Rub with a dry cloth using a
small amount of cleaner.
Heat tint or
discoloration
Penny-Brite or Copper-Brite.
Past NuSteel, DuBois Temp,
or Tarnite. Revere Stainless Steel
Cleaner. Allen Polish, Steel Bright,
Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains Wyandotte,
Bab-O or Zud.
Rub with a dry cloth.
Rub with a dry cloth or stain-
less steel wool.
Apply with damp sponge or
cloth.
Rub with a damp cloth.
Burnt-On Foods and
Grease Fatty Acids,
Milkstone (where
swabbing or rubbing
is not practical)
Easy-O, De-Grease-It, 4 to 6%
hot solution of such agents as
trisodium phosphate or sodium
tripolyphosphate or 5 to 15% caustic
soda solution
Apply generous coating. Allow
to stand for 10-15 minutes.
Rinse.
Repeated application may be
necessary.
Excellent removal, satisfactory
for use on all nishes.
Tenacious Deposits,
Rusty Discolorations,
Industrial
Atmospheric Stains
Oakite No. 33, Dilac Texo 12, Texo NY,
Flash-Klenz, Caddy Cleaner,
Turco Scale 4368 or Permag 57.
Swab and soak with clean
cloth.
Let stand 15 minutes or more
according to directions on
package, then rinse and dry.
Satisfactory for use on all
nishes
Hard Water Spots
and Scale
Vinegar.
5% oxalic acid, 5% sulfamic acid, 5 to
10% phosphoric acid, or Dilac, Oakite
No. 33, Texo 12, Texo N.Y.
Swab or wipe with cloth. Rinse
with water and dry.
Swab or soak with cloth. Let
stand 10-15 minutes. Always
follow with neutralizer rinse,
and dry.
Satisfactory for all nishes.
Satisfactory for all nishes.
Eective on tenacious deposits
or where scale
has built up.
METHODS FOR CLEANING STAINLESS STEEL
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 23
HELP
Trouble Diagnosis for the User
Malfunction Possible Cause Likely Solution
No cooling - unit is silent
Unit not plugged in.
Fuse or circuit breaker tripped.
Power cord plug loose in outlet.
Connect to proper voltage circuit Replace
fuse or reset breaker.
Check outlet for loose connection, replace
as needed
Unit cools but seems to be on all the time Dirty condenser Clean condenser
Space temperature too high
Dirty condenser
Evaporator iced over Unit in high
temperature environment
Clean condenser Defrost evaporator
Reduce temperature of room
Space temperature too low Temperature control Adjust or replace control
Trouble Diagnosis for the Technician
No cooling - compressor does not hum Temp control stuck in open position Replace temp control.
No cooling - compressor hums but does not
start
Low voltage to unit.
Compressor starting system failure
Check voltage, correct as needed. Check
start relay and start capacitor. See next
step.
No cooling - compressor starts but shuts
o
Compressor start relay failure Compressor
start capacitor failure
Replace relay. Replace capacitor.
No cooling - compressor cycles on and o Overheating weak overload
Clean condenser, check fan motor and
blade. Check refrigerant charge. Replace
overload.
Unit cools, but is slow to pull cabinet
temperature down
Evaporator fan not turning
Check fan(s), on multiple fan units one fan
may be turning slowly and will need to be
replaced.
Unit cools but turns on and o frequently
No product in cabinet. Temperature control
defective Refrigeration issue
Fill cabinet Replace control
Have system checked
Makes excessive noise
Tubing rattle Loose parts
Bent or broken fan blade Noisy fan motor
Check tubing for routing Check for loose
components Replace fan blade
Replace fan motor
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air24
FOR THE SERVICE TECH - R290
Refrigeration service should only be attempted by a trained trade professional certied to work on R290 systems.
Here are some critical service items.
This list does not qualify anyone to service the unit. It is a
reminder and checklist for the service tech. Keep these in
mind for R290 service:
Wire nuts are NOT to be used when changing an
electrical part.
The switches in this product are sealed, only exact
replacements may be used.
The process tubes are to be used for service access.
Cut out (with tubing cutter) refrigeration components
that are to be replaced. Do NOT un-braze.
Because R290 can be vented into the air during
service, the venting MUST be in an area free from
ame or spark. It must be near an opend window or
door.
A sign noting service of a system containing propane
must be attached to the unit during refrigeration
service.
A combustible gas leak detector must be used to
inform anyone in the area when propane is present in
the air.
Other Information:
Evacuation: It is critical that a refrigeration system be
leak free and internally dry. A thorough evacuation with
a good vacuum pump with a micron gauge attached is the
only way to ensure that the system is dry and ready for a
charge of refrigerant.
Charging: The system is critically charged and the proper
type and amount MUST be weighed in.
Overcharge symptoms: Unit will cool properly but
the suction line temperature will be unusually cold.
Compressor run time will be longer than normal.
Undercharge symptoms: Long run time, poor cooling and
a hot compressor dome are the main symptoms of an
undercharge.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 25
FOR THE SERVICE TECH - WIRING DIAGRAM
WHITE
2
1
BLACK
BLACK
WHITE
EVAP FAN
POWER
SUPPLY
LAMP
*SEE CONTROLLER DETAIL
2
3
*SEE CONTROLLER DETAIL
WHITE
BLACK
*SEE CONFIGURATION CHART
COMPRESSOR DETAIL
L.E.D. LAMP
DIGITAL INPUT
SIGNAL
START RELAY
10
COMP
CONDENSER FAN
C
R
S
2
4
OL
1
R.C.
S.C.
2
*SEE CONTROLLER DETAIL
4
*SOLID DOOR MODELS ONLY
115VAC 60 HZ
115V REFRIGERATOR ONE SYSTEM
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25Beverage-Air26
LIMITED WARRANTY
WARRANTY (Warranty valid in USA and Canada)
SEVEN (7) YEAR PARTS, LABOR AND COMPRESSOR
WARRANTY:
Beverage-Air Corporation warrants to the original
purchaser of Beverage-Air branded equipment,
including all parts thereof, that such equipment is
free from defects in material and workmanship, under
normal use, with proper maintenance, and service as
indicated by Beverage-Air installation and operation
instructions, for a period of SEVEN (7) years from
the date of installation, or eighty-eight (88) months
from the date of shipment from the manufacturer,
whichever is earlier (units shipped from July 1, 2024
are eligible for 7-year warranty). In addition, Beverage-
Air warrants the hermetically/semi-hermetically
sealed compressor (part only) for SEVEN (7) years; not
to exceed eighty-eight (88) months from the date of
shipment from Beverage-Air, provided upon receipt of
the compressor, manufacturer examination shows the
sealed compressor to be defective. This warranty does
not cover freight for the replacement compressor or
freight for the return of the failed compressor.
* Units shipped after 07/01/2024. Previous warranty
applies to units shipped prior.
EXCEPTIONS:
CT96 and CF3 models carry a ONE (1) year parts
and labor warranty, limited to fteen (15) months
from date of shipment from Beverage-Air. These are
excluded from additional compressor warranty.
SR/SF (Slate) models carry a TWO (2) year parts and
labor warranty, limited to twenty-seven (27) months
from date of shipment from Beverage-Air.
BZ, VM, CDR, DPCR, MT and Blast Chillers carry a
THREE (3) year parts and labor warranty; additional
TWO (2) years compressor part only.
Units installed in Residential applications will be
not covered under this warranty. Units are intended
for Commercial use only.
Also, this compressor-part only warranty does NOT
apply to any electrical controls, condenser, evaporator,
fan motors, overload switch, starting relay, capacitors,
temperature control, lter/drier, accumulator,
refrigeration tubing, wiring harness, labor charges, or
supplies which are covered by the warranty above.
Note: 3rd party extended warranties are not covered by
this warranty statement.
Normal wear parts, as deemed by Beverage-Air, such
as but not exclusive to, light bulbs/lamps and gaskets
are not covered by this warranty. For the purpose of
this warranty, the original purchaser shall be deemed
to mean the individual or company for who the product
was originally installed.
Units that utilize variable speed compressor technology
can experience nuisance tripping on Class A GFCI
outlets which have a trip limit of 4 mA to 6 mA. To
avoid this issue in a location that requires GFCI circuit
protection, Beverage-Air & Victory recommends using a
HUBBELL Model Number GFRST83W 20A Heavy Duty
Hospital Grade Self-Test GFCI Receptacle. Nuisance
tripping not covered under warranty.
Our obligation under this warranty shall be limited to
repairing or replacing, including labor, any part of such
product, which proves thus defective. Beverage-Air
reserves the right to examine any product claimed to
be defective and request photos of the unit prior to
dispatching service. Moisture or water damage is not
covered under warranty. If service is deemed non-
warranty, Beverage-Air reserves the right to bill the end
user for service.
The labor warranty shall be for self-contained units
only and for standard straight time, which is dened
as normal service rate time, for service performed
during normal working hours. All warranty labor will
be covered at standard time. Any service requested
outside of a servicer's normal working hours including
weekends and any additional overtime will be at
the responsibility of the equipment purchaser. Any
part or accessory determined to be defective in the
product should be returned to the company within
thirty (30) days under the terms of this warranty
and must be accompanied by a record of the cabinet
model, serial number, and identied with a return
material authorization number (RMA#) issued by the
manufacturer.
Special installation/applications, including remote
locations, are limited in coverage by this warranty.
Any installation that requires extra work, and/or
travel, to gain access to the unit for service is the sole
responsibility of the equipment purchaser.
Improper operation resulting from factors, including
but not limited to, improper or negligent cleaning
and maintenance, improper installation, low voltage
conditions, inadequate wiring, outdoor use (unless
otherwise specied) and accidental damage are
not manufacturing defects and are strictly the
responsibility of the purchaser.
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25 Beverage-Air 27
LIMITED WARRANTY (CONT'D)
With the exception of Blast Chillers, the product
is designed for maintaining temperature and not
bringing food to a desired temperature and therefore
cannot be held responsible for this function under
warranty. Units must be in a conditioned environment
or warranty will be void. Non-standard use of unit can
also be subject to reduced or voided warranty.
Condensing coils must be cleaned at regular intervals
as a part of preventative maintenance for optimal
performance. Failure to do so is subject to a voided
warranty. Although cleaning requirements vary
in accordance with operation of various products,
Beverage-Air recommends a minimum monthly
cleaning.
NO CLAIMS CAN BE MADE AGAINST THIS WARRANTY
FOR SPOILAGE OF FOOD, PRODUCTS, LOSS OF SALES
OR CONSEQUENTIAL DAMAGES.
THE FOREGOING WARRANTIES ARE EXPRESSLY
GIVEN IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS, IMPLIED, OR STATUTORY, INCLUDING
THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE,
WHICH ARE HERBY DISCLAIMED, ALL OTHER
OBLIGATIONS OR LIABILITIES ON OUR PART, AND
WE NEITHER ASSUME, NOR AUTHORIZE ANY OTHER
PERSON TO ASSUME FOR US, ANY OBLIGATION OR
LIABILITY IN CONNECTION WITH THE SALE OF SAID
REFRIGERATION UNITS OR ANY PARTS THERE OF.
This warranty shall not be assignable and shall be
honored only in so far as the original purchaser. This
warranty does not apply outside the limits of the
United States of America and Canada, nor does it apply
to any part that has been subject to misuse, neglect,
alteration, accident, or to any damage caused by
transportation, ood, re, acts of terrorism, or acts of
God.
LIMITATION OF LIABILITY:
Beverage-Air Corporation or their aliates shall
not be liable for any indirect, incidental, special or
consequential damages, or losses of a commercial
nature arising out of malfunction equipment or its
parts components thereof, as a result of defects in
material or workmanship.
THE ORIGINAL OWNER'S SOLE AND EXCLUSIVE
REMEDY AND BEVERAGE-AIR'S SOLE AND EXCLUSIVE
LIABILITY SHALL BE LIMITED TO THE REPAIR
OR REPLACEMENT OF PARTS OR COMPONENTS
CONTAINED IN THE EQUIPMENT IDENTIFIED
ABOVE WHICH UNDER NORMAL USE AND SERVICE
MALFUNCTION AS A RESULT OF DEFECTS IN
MATERIAL OR WORKMANSHIP, SUBJECT TO THE
APPLICABLE PROVISIONS AND LIMITATIONS STATED
ABOVE.
Note: Additional Terms and Conditions of sale may
apply. Notice: Specications are subject to change
without notice. Contact Beverage-Air for specic model
agency approval. All prices are ex-works Brookville,
PA. July 1, 2024
background
User Manual for HR Refrigerators Beverage-Air
Rev. 04/25
Warranty Registration
Register your product online at beverage-air.com/parts-service or ll out and mail the form below.
Cabinet Model Number: _____________________________________________ Date Of Installation: _________________
Cabinet Serial Number: _____________________________________________
Location Of Product
Business Name: ____________________________________________________
Business Street: ____________________________________________________
Business City: ____________________________________ State: _________ Postal Code:___________
Mail to: Beverage-Air, 3779 Champion Blvd, Winston-Salem, NC 27105

Specifications

Beverage-Air HRPS3HC-1S Questions and Answers