Range Resolution Accuracy
200mV 100uV ±(0.5% of reading + 3 digits)
2V 1mV
20V 10mV
200V 100mV
600V 1V
±(0.8% of reading + 2 digits)
Overload Protection:
600V DC/peak AC
on all ranges
Range Resolution Accuracy (50Hz ~ 500Hz)
200V 100mV
600V 1V
±(2.0% of reading + 10 digits)
:
Overload Protection: 600V AC/DC on all ranges

Range Resolution Accuracy
200uA 0.1uA
2mA 1uA
20mA 10uA
200mA 100uA ±(2.0% of reading + 2digits)
10A 10mA ±(2.0% of reading + 10 digits)
±(1.8% of reading + 2 digits)
Overload Protection: 500V DC/rms AC on all ranges.
Range Resolution Accuracy
±(1% of reading + 10 digits)
±(1% of reading + 4 digits)
Overload Protection: 500V DC/rms AC on all ranges.
0
o
F
~750
o
F
750
o
F
~1380
o
F
32
o
~1300
o
F
1
o
F
±1% ± 4d ±1.5% ± 15d
Range
Resolution
Accuracy

0-1000
Range
Tested range
Tested current
Tested voltage
Ib = 1uA Vcd = 3V
Measure a diode’s forward voltage
Buzzer sounds if continuity