Thermal Network Camera User Manual
9
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.
Note
Go toImage VCA Rules Display to adjust the fonts size and the temperature colour of normal,
alarm and pre-alarm.
3.3.3 Object Missing
This object is not available in the repository.
3.3.4 Set Thermography Rule
Steps
1. Customize the rule name.
2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface
where the position to be measured.
Point
Please refer to Point Thermographyfor detailed configuration.
Line
Please refer to Line Thermographyfor detailed configuration.
Area
Please refer to Area Thermographyfor detailed configuration.
3. Click and set the Alarm Rule.
Alarm Temperature and Pre-Alarm Temperature
Set the alarm temperature and pre-alarm temperature. E.g., select Alarm Rule as Above
(Average Temperature), set the Pre-Alarm Temperature to 50 °C, and set the Alarm
Temperature to 55 °C. The device pre-alarms when its average temperature is higher than
50 °C and alarms when its average temperature is higher than 55 °C.
Tolerance Temperature
Set the tolerance temperature to prevent the constant temperature change to affect the
alarm. E.g., set tolerance temperature as 3°C, set alarm temperature as 55°C, and set pre-
alarm temperature as 50°C. The device sends pre-alarm when its temperature reaches 50°C
and it alarms when its temperature reaches 55°C and only when the device temperature is
lower than 52°C will the alarm be canceled.