AXIST8331PIRMotionDetectorSeries
ReferenceMaterial
Therightimageshowsaconnectionwithtamperandalarmseparated.Thisconnectionrequiresacamerawithatleasttwo
congurableI/Oports.
AXIS T8331-E
Forpositionoftheterminals,seeHardwareOverviewonpage8
AXIST8331PIRMotionDetectorSeriesSchematics
BelowisaschematicshowingtheconnectionwithacameraandthePIRsensor.Thisisthedefaultconnectionwithtamperand
alarmtogether(Pin3).Pin1GND,Pin2Power,Pin4notused.
1
2
3
4
PIRCamera
1. GND
2. Power
3. I/O con gured as input
4. Not use d
Sup ply of PIR
PIR Alarm N.C.
Tampering Switch N.C.
BelowisaschematicshowingtheconnectionwithacameraandthePIRsensor.Inthisconnectiontamperandalarmareseparated.
Pin3alarm,Pin4tamper.Pin1GND,Pin2Power.