E. Water Supply and Drain Connections
See Fig. 1
Water supply inlet is 1/2" female pipe thread (FPT).
A water supply line shut-off valve and drain valve should be installed. A minimum of
1/4" OD copper tubing is recommended for the water supply line.
Water supply pressure should be a minimum of 10 PSIG (0.7 bar) and a maximum of
113 PSIG (7.5 bar). If the pressure exceeds 113 PSIG (7.5 bar), the use of a pressure
reducing valve is required.
Drain outlet is 3/4" FPT.
Drain line must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get good
flow. A vented tee connection is also required for proper flow.
Drain line should not be piped directly to the sewer system. An air gap of a minimum of
2 vertical inches (5 cm) should be between the end of the drain pipe and the floor drain.
This dispenser should be installed in accordance with applicable national, state and
local regulations.
A plumbing permit and services of a licensed plumber may be required in some areas.
Fig. 1
Dispenser
Shut-Off Valve
Drain Valve
Water Supply Inlet
1/2" FPT
Drain Outlet
3/4" FPT
Separate piping to
approved drain.
Two-inch
(5 cm) air gap
Floor
Drain