Honeywell HC35W45R3 5MP IR Fixed Mini-Dome Camera

Honeywell 35 Series User Guide - Page 57

For HC35W45R3.

PDF File Manual, 81 pages, Read Online | Download pdf file

HC35W45R3 photo
Loading ...
Loading ...
Loading ...
46
Honeywell 35 Series IP Cameras User Guide
Open: Camera alarm relay is Normal Closed (Grounded). It will turn to Open state
when an alarm event is generated to trigger it.
Note:
The signal status will take effect after one alarm out is triggered.
Manual control: If alarm out signal is coming, click Close to disable alarm out or click
Open to keep alarm out status.
If alarm out signal is not coming, it is opposite with above.
Timing alarm output: Enable Timing alarm output and set time for alarm out. The
device will continue trigger alarm out during the selecting time slot.
Note:
For 5M/8M models
(HC35WX5RX/HC35WX8RX), an alarm input and an alarm output
can be configured.
For PTZ models HC35WZ5R30/HC35WZ2R25, alarm input1/input2 and alarm
output1/ output2 can be configured.
For PTZ model HC35WZ5R30W, alarm input1~7, and alarm output1/ output2 can be
configured.
Configuring SD Card Alarm
Go to Setup > Alarm & Event > SD Card Alarm.
SD card alarm: Check the checkbox to enable SD card alarm.
Alarm threshold(used space): The camera will alarm when used space achieves the
alarm threshold.
Alarm interval: Set the interval.
Output channel: Check the checkbox to set the Output channel