9
INFRA-RED and WHITE-LIGHT
RM/RL 300/150 and Hybrid Models
(Final speciļ¬cation model dependant - model shown: RM/RL 300 Premium)
Note - Hybrid control boards will be labelled IR/WL
Hybrid PSU Models
Factory Setting:
IR controlled by photocell
WL controlled by telemetry night time only
Attach 1 wire of volt free input into photocell following output on top control board and other
wire of volt free input into telemetry input on bottom board.
Other set up options available...contact Raytec.
Photocell
Up to x3
LED Output
(Polarity Sensitive)
(Model Dependant)
Power Adjust
Photocell
following contact
- volt free, non
polarity sensitive
(Premium PSU only)
Photocell
Sensitivity
Mains Input
(100V to 230V AC)
Auto-Sensing
12V DC Power
Output (Premium
PSU only)
Telemetry Input
requires zero volt,
latched input