FLUKE 9100S-B-156 User Manual
User Manual FLUKE 9100S-B-156 Dry Block Calibrator with block B, 95 to 707°F
Documents for FLUKE 9100S-B-156
The following documents are available:
User Manual
User Manual for the Fluke 9100S-B-156 Dry Block Calibrator with block B, 95 to 707°F - (English)
Read Online
|
Download pdf
Photos
Photos:
View Photos
User Manual for the Fluke 9100S-B-156 Dry Block Calibrator with block B, 95 to 707°F
For 9100S-B-156.
Page 1/41
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
Page 41
Contents
Table of Contents
Search
Previous
Next
Troubleshooting
Bookmarks
9100S
Dry-W
ell Calibrator
Users Guide
91
00S___ugeng0000
1.888.610.7664
sales@GlobalT
estSupply
.com
Fluk
e
-
D
ir
ect
.com
Loading ...
Loading ...
Loading ...
1
2
3
4
5
6
>
Summary of Contents for FLUKE 9100S-B-156:
Table of Contents
3
1 Before You Start
8
1.1 Introduction
8
1.2 Symbols Used
8
1.3 Safety Information
10
1.3.1 Warnings
10
1.3.2 Cautions
11
1.4 Authorized Service Centers
12
2 Specifications and Environmental Conditions
13
2.1 Specifications
13
2.2 Environmental Conditions
13
3 Quick Start
14
3.1 Unpacking
14
3.2 Set-up
14
3.3 Power
14
3.4 Setting the Temperature
14
4 Parts and Controls
16
4.1 Rear Panel
16
4.2 Side View
17
4.3 Front Panel
18
4.4 Constant Temperature Block Assembly
18
5 General Operation
20
5.1 Setting the Temperature
20
5.2 Changing Display Units
20
6 Controller Operation
21
6.1 Well Temperature
21
6.2 Temperature Set-point
21
6.2.1 Programmable Set-points
21
6.2.2 Set-point Value
22
6.2.3 Temperature Scale Units
22
6.3 Scan
22
6.3.1 Scan Control
24
6.3.2 Scan Rate
24
6.4 Set-point Resistance
24
6.5 Secondary Menu
25
6.6 Heater Power
25
6.7 Proportional Band
25
6.8 Controller Configuration
26
6.9 Operating Parameters
27
6.10 High Limit
27
6.11 Serial Interface Parameters
27
6.11.1 Baud Rate
27
6.11.2 Sample Period
28
6.11.3 Duplex Mode
28
6.11.4 Linefeed
29
6.12 Calibration Parameters
29
6.12.1 Hard Cutout
30
6.12.2 R0
30
6.12.3 ALPHA
30
6.12.4 DELTA
31
7 Digital Communication Interface
32
7.1 RS-232 Connection
32
7.2 Interface Commands
33
8 Test Probe Calibration
35
8.1 Calibrating a Single Probe
35
8.2 Dry-well Characteristics
35
8.2.1 Stabilization and Accuracy
35
9 Calibration Procedure
36
9.1 Calibration Points
36
9.2 Calibration Procedure
36
9.2.1 Compute DELTA
37
9.2.2 Compute R0 and ALPHA
37
9.2.3 Accuracy and Repeatability
38
10 Maintenance
39
11 Troubleshooting
40
11.1 Troubleshooting Problems, Possible Causes, and Solutions
40
11.2 CE Comments
41
11.2.1 EMC Directive
41
11.2.2 Low Voltage Directive (Safety)
41
Tables
6
Table 1 International Electrical Symbols
8
Table 2 Controller communications commands
33
Figures
7
Figure 1 Back Panel
16
Figure 2 Side view of the 9100S showing the prop stand
17
Figure 3 Front panel
18
Figure 4 Fixed block options
19
Figure 5 Controller operation flow chart
23
Figure 6 Serial cable wiring
32
File type: PDF
File name: 94248718_9100s-b-156.pdf
File size: 780.97 KB
File Language: English
Pages: 41
Author: FLUKE
Published: 2024-02-10
Updated: 2024-02-10
Download File
Specifications
Brand:
FLUKE
Model: 9100S-B-156
View in the file:
Full Specifications
See other models:
9100S-D-156
1587/MDT FC-NIST
375 FC
1587 FC
1587KIT/62MAX+ FC
Photos
Download User Manual
Related Products
FLUKE 9140-A-156
FLUKE 9009-B-156
FLUKE 9150-A-156
FLUKE 9103-A-156
FLUKE 7102-156
FLUKE 9102S-156
FLUKE 9143-A-156
FLUKE 9100S-C-156
FLUKE 9100S-A-156
FLUKE 9009-Y-156
FLUKE 9011-A-156
FLUKE 7103-156
FLUKE 6102-156
FLUKE 721EX-1615
FLUKE 9144-DW-156
Table of Contents
×
Table of Contents
3
1 Before You Start
8
1.1 Introduction
8
1.2 Symbols Used
8
1.3 Safety Information
10
1.3.1 Warnings
10
1.3.2 Cautions
11
1.4 Authorized Service Centers
12
2 Specifications and Environmental Conditions
13
2.1 Specifications
13
2.2 Environmental Conditions
13
3 Quick Start
14
3.1 Unpacking
14
3.2 Set-up
14
3.3 Power
14
3.4 Setting the Temperature
14
4 Parts and Controls
16
4.1 Rear Panel
16
4.2 Side View
17
4.3 Front Panel
18
4.4 Constant Temperature Block Assembly
18
5 General Operation
20
5.1 Setting the Temperature
20
5.2 Changing Display Units
20
6 Controller Operation
21
6.1 Well Temperature
21
6.2 Temperature Set-point
21
6.2.1 Programmable Set-points
21
6.2.2 Set-point Value
22
6.2.3 Temperature Scale Units
22
6.3 Scan
22
6.3.1 Scan Control
24
6.3.2 Scan Rate
24
6.4 Set-point Resistance
24
6.5 Secondary Menu
25
6.6 Heater Power
25
6.7 Proportional Band
25
6.8 Controller Configuration
26
6.9 Operating Parameters
27
6.10 High Limit
27
6.11 Serial Interface Parameters
27
6.11.1 Baud Rate
27
6.11.2 Sample Period
28
6.11.3 Duplex Mode
28
6.11.4 Linefeed
29
6.12 Calibration Parameters
29
6.12.1 Hard Cutout
30
6.12.2 R0
30
6.12.3 ALPHA
30
6.12.4 DELTA
31
7 Digital Communication Interface
32
7.1 RS-232 Connection
32
7.2 Interface Commands
33
8 Test Probe Calibration
35
8.1 Calibrating a Single Probe
35
8.2 Dry-well Characteristics
35
8.2.1 Stabilization and Accuracy
35
9 Calibration Procedure
36
9.1 Calibration Points
36
9.2 Calibration Procedure
36
9.2.1 Compute DELTA
37
9.2.2 Compute R0 and ALPHA
37
9.2.3 Accuracy and Repeatability
38
10 Maintenance
39
11 Troubleshooting
40
11.1 Troubleshooting Problems, Possible Causes, and Solutions
40
11.2 CE Comments
41
11.2.1 EMC Directive
41
11.2.2 Low Voltage Directive (Safety)
41
Tables
6
Table 1 International Electrical Symbols
8
Table 2 Controller communications commands
33
Figures
7
Figure 1 Back Panel
16
Figure 2 Side view of the 9100S showing the prop stand
17
Figure 3 Front panel
18
Figure 4 Fixed block options
19
Figure 5 Controller operation flow chart
23
Figure 6 Serial cable wiring
32
Search:
×
Search