7
PLEASE NOTE. In the event that you
inadvertently have the valves of your grill
turned to the “ON” position, and then open
the valve on top of your tank, the excess flow
device will activate and shut off the flow of
gas. If this should occur, turn the valves to
the “OFF” position on your grill head then the
valve on the tank “OFF”. Wait five minutes
before attempting to light. Always turn on the valve at the
top of your tank and then the valves to your grill head to the
“ON” position. The safety system detailed above has been
incorporated into your PGS gas grill to provide you and your
family the maximum in safety when operating the grill.
PLEASE DO NOT CHANGE THE LP HOSE OR USE WITH A TANK
LARGER THAN 20 LBS. OR TO A TANK EQUIPPED WITH
ANYTHING OTHER THAN A QCCI FITTING. TURN VALVE
THAT IS LOCATED AT THE TOP OF TANK TO “OFF” WHEN
GRILL IS NOT IN USE.
PROPANE CYLINDER FILLING & HANDLING
TIPS
When the hose and regulator are disconnected from the tank, the
flow of gas is safely shut off. You must still shut off the main tank
valve located at the top of the tank when transporting your tank or
when the unit is not in use.
Do not modify hose or LP fittings. Contact local dealer or
distributor if tank, hose or fittings need replacement.
If it is evident there is excessive abrasion or wear, or
the hose is cut, it must be replaced prior to the grill
being operated. Please see your local PGS dealer or
call the factory for an exact replacement.
Store propane tank outdoors in a cool, well ventilated
area. Never store extra tanks in, on, or around your
grill.
Turn off tank when not in use.
Transport tanks upright ONLY.
Never allow a tank to be overfilled. 100% empty tanks
hold only 4.5 gallons of propane.
Inspect your grill cabinet often to ensure that
ventilation openings in sides and back of cart are free
from debris and have proper air circulation.
Never paint LP cylinder a dark color. This may cause
OVERHEATING. Do not apply heat directly to tank.
LP Gas is stored under high pressure and must be
handled with care. Do not handle a tank roughly.
Be sure your LP gas dealer checks the cylinder with a
soapy solution for leaks after filling.
Do not turn gas valve on unless connection between
regulator and tank is complete.
Storage of your gas grill indoors is permissible only if
the cylinder is disconnected, removed from grill and
cylinder stored outdoors in a well-ventilated area away
from children.
BEFORE ATTEMPTING TO LIGHT GRILL, BE CERTAIN THE
GAS VALVE KNOBS ARE IN THE OFF POSITION. TURN TANK
VALVE ON BY TURNING KNOB ON TOP OF TANK, COUNTER
CLOCKWISE. CHECK ALL CONNECTIONS WITH A
SOLUTION OF 50% LIQUID SOAP, 50% WATER.
SOLUTION CAN BE SPRAYED ON WITH A SPRAY BOTTLE OR
PAINTED ON ALL CONNECTIONS WITH A BRUSH. IF
BUBBLES APPEAR THERE IS A LEAK, TURN OFF GAS,
TIGHTEN FITTINGS AND REPEAT THIS CHECK.
NOTE. A PRESSURE REGULATOR AND HOSE ARE SUPPLIED
WITH GRILL MUST BE USED. REPLACEMENT PARTS MUST
BE OEM EXACT REPLACEMENT ONLY.
The cylinder must be provided with a shutoff valve terminating in an
LP-gas supply cylinder, valve outlet specified, as applicable, for
Connection No. 510 in the Standard for Compressed Gas Cylinder
Valve Outlet and Inlet Connections, ANSI/CGA-V-1, or Connection No.
600 in the Compressed Gas Association’s Limited Standard Cylinder
Valve Outlet Connection for Propane Small Valve Series or a
combination LP-gas cylinder valve and QCC1 assembly complying
with 1.5.5-c and a safety relief device making a direct connection with
the vapor space of the cylinder. The cylinder supply system must be
arranged for vapor withdrawal and must include a collar to protect
the cylinder valve.
PROPANE GAS CYLINDER
DISCONNECTED CYLINDER MUST NOT
BE STORED IN A BUILDING, GARAGE OR ANY
OTHER ENCLOSED AREA. BEFORE LIGHTING
GRILL, INSPECT THE HOSE TO ENSURE
THAT IT IS INTACT AND THERE ARE NO LEAKS.
All LP-gas cylinders used with this grill shall be approximately 12" in
diameter and about 18" in height. The maximum fuel capacity must
be 20 lbs. of propane (47.7 lbs. nominal water capacity or 4.5 gallons).
DO NOT connect your grill to a propane gas cylinder that exceeds this
capacity. USE ONLY CYLINDER DESCRIBED IN THIS SECTION.
All propane-gas cylinders used with the grill
must be constructed and marked in
accordance with the specifications for
propane-gas cylinders of the U.S.
Department of Transportation (DOT). In
Canada, gas cylinders must meet
CAN/CSA-B339-Cylinders, Spheres, and
Tubes for Transportation of Dangerous
Goods: and Commission. Cylinder used must
include a collar to protect the cylinder valve.
All refillable propane-gas cylinders used with the gas grill must be
inspected at every filling and must be re-qualified by licensed LP-gas
cylinder filler in accordance with DOT (US) or CTC (Canadian)
requirements for LP-cylinders.
LP-Gas Tank Specifications:
Weight (filled) 40 lbs. (18.14 kg)
Capacity 4.5 gallons
Diameter (outside) 12 1/8" (30.8 cm)
Height 18" (45.7 cm)
Connection TYPE I (QCC)
NATURAL GAS MODELS
Your PGS gas grill has been designed and produced for
outdoor use only! Every gas-burning appliance produces
carbon monoxide and should not be allowed to accumulate
in confined areas. DO NOT OPERATE YOUR PGS GAS GRILL
INSIDE A HOME, GARAGE, RECREATIONAL VEHICLE, BOAT,
TENT OR ANY OTHER ENCLOSED AREA.
NEVER ATTEMPT TO OPERATE YOUR NATURAL GAS GRILL
USING PROPANE, CHARCOAL OR ANY OTHER FUEL SOURCE.
The grill is designed to operate on Natural Gas at a pressure of 4.5"
water Column (W.C.) (1.75 kPa) unregulated. Check with your gas
utility for local gas pressure. Use of your gas grill at pressures other
than approximate 4.5" water column could affect the performance of
your grill and requires installation of a natural gas regulator set at
4.5W.C. When choosing a location for your grill, you must locate it
at least 30” away from any combustible material and out of traffic
paths. The grill and its individual shutoff valve must be
disconnected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig (3.5kPa).
The grill must be isolated from the gas by closing its valves during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.5kPa).