Decorative hood maintenance
To clean the hood surface, use a mild detergent and a soft cloth to avoid scratching it.
The device can be used again after everything has dried properly.
If you use the decorative extractor hood in recirculation mode, you must regularly replace the activated carbon filter
(see section "Replacing the activated carbon filter").
Cleaning the aluminum grease filter
CAUTION: Risk of fire!
Grease residues on the aluminum filter can ignite if exposed to high temperatures. It is therefore important that the
grease filter is cleaned regularly.
We recommend that you clean the grease filter monthly:
Remove the aluminum grease filter by sliding the latch back into the slot, gently push the filter and pull it forward.
Wash the grease filter in a solution of hot water and neutral detergent. Immerse the filter in the solution.
Then clean with a soft brush, rinse well with warm water and let dry.
The grease filter is also dishwasher safe (up to 60 °C). Slight discoloration may occur in the dishwasher. This does
not affect the function of the grease filter.
Activated carbon filter replacement
> The activated charcoal filter absorbs odors and should be replaced at least every six months, depending on use.
> Order the charcoal filter from your dealer or accessory store. To order, use the reference number indicated in
"Technical data".
See section "Installation of activated carbon filter for recirculation mode".
Remove the old charcoal filter by turning it counterclockwise.
Lamp replacement
CAREFUL:
Before replacing the lamp, allow it to cool down. There is a risk of burns! The LED lamp must be replaced by a
qualified person.
Light Specifications: LED, 2 x 1.5W
Remove the aluminum grease filter.
Open the black protective case of the plug connection with a suitable tool.
Pull the bulb slightly and disconnect it from the connector.
Connect the new lamp to the connector and close the protective case.
Reinsert the lamp unit back into the connector until it clicks into place.
Replace the aluminum grease filter.
39