6. Using diagonal wire cutting pliers, gently snip out the
rectangular damper vent covers at the perforations.
B
A
A. Diagonal wire cutting pliers
B. Rectangular damper vent cover
7. Hold the blower motor wire, put the wire through the blower
motor bridge.
A
B
A. Blower motor bridge
B. Blower motor wire
8. Lower blower motor back into the microwave oven. Exhaust
ports face the back of the microwave oven.
A
A. Exhaust Port
9. Reconnect the blower motor wire into the connector.
A
B
A. Blower motor wire
B. Connector
10. Reattach the 2 blower screws into the recessed holes in the
back of the microwave.
A
B
B
A. Screws
B. Holes
11. Check to make sure the 2 screws are secured properly in the
blower motor screw holes, so that the motor cannot move.
A
B
B
A. Screws
B. Blower motor screw holes
12. Return the damper plate to its original horizontal position.
A
A. Damper plate
Loading ...