DS-PDEB1/2-EG2-WB/WE
Wireless Emergency Buon
1
Front Panel
Baery
Appearance
Indicator
Key
Rear Panel
TAMPER Buon
TAMPER Buon:
Tampering Alarm: Trigger alarm when the device is disassembled.
Formang: Format the emergency buon.
Indicator
Alarm: Flashing red indicates the alarm is triggered.
Signal Strength: In the signal strength checking mode,
Signal LED turns green for 3 s: Strong.
Signal LED turns orange for 3 s: Medium.
Signal LED turns red for 3 s: Weak.
Signal LED flashes red for 3 s: Disconnected.
3
Enrollment
1. Log in to the APP Store, download and install the App.
2. Power on the security control panel.
3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery, that can result in an
explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked
with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recy-
clethis.info
1
EN 50131-1:2006+A1: 2009+A2:2017
EN 50131-3:2009
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II
Cerfied by Teleficaon
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

4
Installaon
Install the panic button
Installaon with Sponge Tape
1. Paste the sponge tape on the rear panel.
2. Paste the rear panel on the required place.
Note: Non EN compliant aer Installaon wit Sponge Tape
Check signal strength
Enter the signal checking mode by operang on the control panel.
Solid green for 3 s: Strong signal.
Solid orange for 3 s: Medium signal.
Solid red for 3 s: Weak signal.
Red flashes for 3 s: Lost signal.
1
1
Sponge Tape
Enroll the Peripheral Locally
Enroll the Peripheral
2. Log in to the APP Store, download and install the App.
3. Power on the security control panel.
4. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
1. In the APP, tap the "Enrollment Mode" buon on the control panel page to make the control panel enter the enrollment status.
2. Trigger the peripheral, and it will be automacally enrolled to the control panel.
2
1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral.
2. Trigger the peripheral, and it will be automacally enrolled to the control panel.
Signal Strength Test
xxxx
or
or
or
2
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

1. Insert and rotate the screwdriver in the groove to disassemble the device.
2. Replace the baery.
5
Test
6
REPLACE BATTERY
Installaon with Screw
1. Insert and rotate the screwdriver in the groove to disassemble the device.
2. Secure the device to the wall with two screws through the holes in the rear panel.
3. Align the front panel and the rear panel and buckle them together.
2
Trigger the emergency buon, and the LED indicates the operaon result.
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
1
2
1.Buon
2.Alarm Received
or
1
2
3
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

7
Funcon
8
9
10
Operaon Cauon and Device Maintenance
- All the electronic operaon should be strictly compliance with the electrical safety regulaons, fire prevenon regulaons and other related
regulaons in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service
center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnesm radiaon. Avoid the equipment
installaon on vibraons surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specificaon of the device for the detailed operaon temperature), cold, dusty or
damp locaons, and do not expose it to high electromagnec radiaon.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or radiator is forbidden (ignorance can cause fire
danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfuncon however), and
affecng the endurance of sensor at the same me.
- Improper use or replacement of the baery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of
used baeries according to the instrucons provided by the baery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situaon.
Funcon Descripon
Panic Alarm Press the buon to trigger the alarm while in emergency condion. The LED keeps red for 2 s.
Medical Alarm
Set the panic buon as medical buon via the AX PRO client. Press the buon to trigger the
alarm while in emergency condion. The LED keeps red for 2 s.
Panic Alarm
Press the two buons synchronously to trigger the alarm while in emergency condion. The LED
keeps red for 2 s.
Medical Al
arm
Set the panic buon as medical buon via the AX PRO client. Press the two buons
synchronously to trigger the alarm while in emergency condion. The LED keeps red for 2 s.
4
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Set Up with App
Funcon
Zone Type
Enable Silent Zone
Slide to green to make the zone keep
silent while alarm is triggered.
Select the zone type of the detector.
Descripon
You can view the device status including temperature, signal intensity,baery level, connecon, 24-hour zone, and operaon mode on the device page.
Tap the buon to enter the sengs page.
Cross Zone
Link Camera
If the alarm triggered in both of the linked zones within
the set me, two alarm messages will be reported.
Polling Rate
Set the interval of heartbeat.
Signal Strength Test
Enter the test mode, and view the LED indicaon.
Link with a camera for intruder verificaon.
Formang
Remove the baery. Hold the tamper buon and meanwhile power the device on at the same me. The red LED flashes 3 mes when the
formang is completed.

Note: When the low voltage message appears there will be at least 30 days of use.
11
Specificaon
5
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Model DS-PDEB1/2-EG2-WB/WE
Feature
Buon 1/2
Tamper Protecon Front,Rear
Environment Temperature Indicator Support
Signal Strength Indicator Support
Interface LED Indicator Blue(Alarm)
Transmission
Transmission Technology Tri-X Wireless
Transmission Method Two-Way RF Wireless
Transmission Frequency 433MHz/868 MHz
Transmission Security AES-128 Encrypon
Transmission Range(Free Space) 800m(433MHz)/1.2 Km(868 MHz)
Frequency Hopping Support
Enrolling Method Power up,Remote ID,QR Code
Electrical Characteriscs
Power Supply Baery Powered
Baery Type CR2450 x 1 (included) 620mAh capacity
Consumpon
Quiescent Current: 25 uA
Max: 36.89 mA
Low voltage level 2.60 V
Typical Voltage 3V
Standard Baery Life 3 Years
General
Operaon Temperature -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F)
Operaon Humidity 10% to 90%
PS type Type C
Dimension(WxHxD) 63.8mm × 63.8mm × 17.9mm
Weight 45.5g
Classificaon Use inside the supervised premises
Mounng Method Wall
Applicaon Scenario
Indoor
Green Keymat For Medical Applicaon