Thermographic Cube Camera User Manual
8
improve the temperature measuring accuracy.
Calibration Coefficient
Check to enable it and set the value of calibration coefficient to get the temperature of the
external window or optical material automatically. The setting range is 0 to 30.
Note
You can get the setting value from SDK software.
External Optics/Window Correction
Set the temperature of the external window or optical material (e.g.: germanium window) to
correct the measured temperature.
Version
View the version of current algorithm.
Calibration File Version
View the version of calibration file.
Alarm Interval
Set the time interval of alarms.
Display Rule Info. on Alarm Picture
Select the rule information to be added on the alarm capture.
Alarm Mode
Select the desired alarm mode. In temperature measurement alarm mode, the device
outputs alarm if the detected temperature is higher than the alarm threshold. In interval
temperature measurement alarm mode, the device outputs alarm if the detected
temperature is within the set temperature range.
4. Click Save.
3.3.2 Set Normal Mode
This function is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Configuration Temperature Measurement Basic Settings, and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration Temperature Measurement Advanced Settings, and select Normal.
4. Configure the parameters of normal mode.
1) Configure the parameters in Temperature Measurement Alarm Mode