Here will take the Digifort as an example to introduce the HTTP Notification function.
The following are the detail steps of setting for HTTP Notification in Digifort VMS and our cameras.
Step1: Enable Alarm, set Motion Region and detection Schedule;
Step2: Check the HTTP Notification as Alarm Action, and fill the fields. Then save the alarm setting;
HTTP User Name: admin (the user name of your camera)
HTTP Password: ms1234 (the password of your camera)
HTTP Notification URL:
http://IP:8601/Interface/Cameras/MotionDetection/Notify?Camera=CameraName
IP refers to the PC's IP where the Digifort installed.
8601 is the port for Motion signal in Digifort.
CameraName is the camera name you set in Digifort VMS, like the picture shown below.
Example:
http://192.168.8.75:8601/Interface/Cameras/MotionDetection/Notify?Camera=annie,
this URL format is exactly supported by Digifort VMS, so we can set as above to our cameras and
get it work well.
Step3: choose use motion detection by external notification;
Step4: If successful, you can see the device icon turns yellow in the Surveillance when the camera
is under Motion Detection Alarm;