Care & use/installation
|
11
Low or inSuFFiCienT heAT
ensure that you’ve preheated the desired burner(s) for at
least 10—15 minutes
proper leveling during installation is critical. a grill that is
out of level will cause erratic burner combustion and inef-
ficient, uneven heating. a carpenter’s spirit level should be
used to level the grill both-front-to-back, and side-to-side.
if the low heat problem persists:
•Check the gas supply line sizing requirements.
•Check the gas supply line for kinks or damage.
•Check the thermostatic control for proper operation.
replaCe any damaged supply lines.
•Check the regulator
make sure that the regulator & hose assembly is the one
designed for and supplied with your lynx grill and that it
is correctly set up for the type of fuel you are using. (see
indeX: “regulator Conversion” for further details.)
the hose and regulator provided by lynx must be used if
your grill is set-up for an lp gas Cylinder.
Check that there is no physical pressure being applied to
the regulator attached to the back of the grill. the regulator
contains a flexible diaphragm and should not be allowed to
touch the grill body or its surroundings.
•Check for obstructions
ensure that the burners and drip tray are clean and free
from obstructions.
LP (Propane) units:
•is the cylinder almost empty?
almost-empty cylinders may not have sufficient pressure
to run the burners at high heat.
•have the line pressure checked by a qualified technician
(see indeX: “gas requirements” for further details.)
•flow limiting device
improper lighting procedures may have activated the lp
cylinder’s flow control device, reducing the heat output.
To reset the flow control:
•shut off all burner controls and close the lp cylinder
valve.
•Wait 30 seconds and, very slowly, reopen the cylinder
valve.
•Wait a few seconds and relite a burner.
Bulk LP cylinder users:
Bulk lp cylinder lines must be properly regulated.
ensure that you are using a 4/11 appliance regulator sup-
plied by lynx and converted to lp gas. also ensure that you
do not have more than one regulator in line.
Natural Gas units:
•supply line
ensure that the supply line is at least 3/4” inside diameter
or 1” outside diameter.
•Check line pressure
natural gas inlet pressure should be at least 7” W.C. and
manifold pressure not less than 4” W.C. under full load
(with all burners on.)
•Check burners for blockages.
•Check flame characteristics. (see indeX: “flame, Correct
size”).
•Clean or adjust air shutter (see indeX: “air shutter
adjustment.”).
LiGhTS won’T LiGhT
for the Blue led lights only
•Check power - ensure that the grill is connected to a live
aC power source.
•Contact lynx Customer Care at 888-289-5969.
POTENTIAL PROBLEMS ...continued