TRUE RESIDENTIAL
®
TEC_TM_155 | REV. D | EN09/23/2022Page 24 of 66
P#829867
Rear wall of cut out
DO NOT INSTALL
OUTLET IN THIS AREA!
Countertop
PRIOR TO INSTALLATION
ELECTRICAL OUTLET LOCATION
To minimize the depth of the cutout opening, the
electrical outlet must be positioned as shown below.
Outlet must be flush with wall.
15” (381 mm)
opening
DRAIN CONNECTION
The True Ice
®
machine has a built-in drain pump.
WARNING! PROPER INSTALLATION
REQUIRES CONNECTION TO THE
WATER SUPPLY AND A DRAIN. THESE
CONNECTIONS ARE THE RESPONSIBILITIES
OF THE INSTALLER. TRUE WILL NOT WARRANT
LEAKS OR DAMAGE CAUSED BY IMPROPER
INSTALLATION. IMPROPER CONNECTIONS CAN
RESULT IN PERSONAL INJURY, PROPERTY
DAMAGE AND IMPROPER OPERATION. THE ICE
MACHINE MUST BE INSTALLED ACCORDING
TO ALL APPLICABLE NATIONAL, STATE AND
LOCAL CODES AND REGULATIONS.
DO NOT reduce drain connections any smaller than
1/4” I.D.
96” (2,438.4 mm) 3/8" O.D. x 1/4" I.D. clear PVC
drain hose, 90° 1/2” male NPT x 1/4" O.D. barbed
drain fitting, and hose clamp provided by True.
Check valve required. Check valve and adapter
provided by True. See "Check Valve Installation"
(page 25).
Using hose larger than 1/2” O.D. may require a
larger pump.
Be sure to use the correct I.D. hose for your vertical
rise to ensure the proper flowrate and prevent drain
time alarms. For more information, see “Drain Time
Alarm” (page 40).
If the installation requires a
vertical rise greater
than 84” (2,133.6 mm) include an external drain
pump to cover the additional required pumping
height. Connect the drain tube outlet from the ice
maker to the external drain pump inlet. Do not
remove the internal drain pump provided with the
ice maker. Altering the internal components in any
way will void the warranty.
DO NOT USE HOSE SMALLER THAN 1/4” I.D.
The floor drain must be large enough to
accommodate additional drainage.
The drain pump discharge line must terminate at an
open site drain.
Be sure to thoroughly inspect all connections after
installation to ensure there are no leaks. Use of
thread sealant required.