Vibration Sensor/Gateway
Sensor Installation
Step 9: Confirm the Sensor and Gateway connection
The Bluetooth range between the Gateway and Sensors is 65 m (213 ft) line-of-
sight. However, this range is affected by metal and concrete around the
Sensors and Gateway. Fluke recommends these steps to make sure there is
good connectivity between Sensors and the Gateway.
1. Temporarily place the Sensors on the asset test points. (Do not install
them yet.)
2. In the app, make sure you see the alert: Sensor is now connected.
3. Monitor the the app for several minutes. Look for the alert: Sensor has lost
connection.
ο If you do not receive the alert the position is good.
ο If you receive the alert, reposition the Gateway closer to the Sensor.
Monitor the app again.
4. When the Sensor remains connected for at least 5 minutes without loosing
the connection, use epoxy to install the Sensor.
≤65 m (213 ft)
line-of-sight