Smeg PGF31G2 Gas Hob 30 cm

User manual EN - Page 14

For PGF31G2.

PDF File Manual, 18 pages, Read Online | Download pdf file

PGF31G2 photo
Loading ...
Loading ...
Loading ...
INSTALLATION - 3591477A686/B
e
It is possible to identify the available gas types based on the country the appliance is to be installed
in. Refer to the heading number to identify the correct values in the “Burner and nozzle characteristics
tables".
Burner and nozzle characteristics tables
4 Natural Gas G2.350
G2.350
13 mbar
5 LPG G30/31
G30/31
28-30/37 mbar
••••••
G30/31
30/30 mbar
••
6 LPG G30/31
G30/31
37 mbar
7 Town Gas G110
G110
8 mbar
••
1 Natural Gas G20 - 20 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.9 4.1 2.50 1.05
Nozzle diameter (1/100 mm) 70 150 108 72
Pre-chamber (printed on nozzle) (H1) (H3) (Y) (X)
Reduced flow rate (W) 400 1200 800 400
2 Natural Gas G20 - 25 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.9 4.1 2.50 1.10
Nozzle diameter (1/100 mm) 65 145 108 75
Pre-chamber (printed on nozzle) (H1) (H3) (Y) (H1)
Reduced flow rate (W) 400 1200 800 400
3 Natural Gas G25.1 - 25 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.9 3.9 2.50 1.05
Nozzle diameter (1/100 mm) 72 148 115 77
Pre-chamber (printed on nozzle) (H1) (F3) (F3) (F1)
Reduced flow rate (W) 400 1200 800 400
4 Natural Gas G2.350 - 13 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.9 3.8 2.40 1.00
Nozzle diameter (1/100 mm) 91 200 148 94
Pre-chamber (printed on nozzle) (Y) (H1) (F3) (Y)
Reduced flow rate (W) 400 1200 800 400
5 LPG G30/31 - 30/37 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.9 4.1 2.50 1.05
Nozzle diameter (1/100 mm) 44 100 79 50
Pre-chamber (printed on nozzle) - - (Z) -
Reduced flow rate (W) 400 1400 800 400
Rated flow rate G30 (g/h) 65 298 182 76
Rated flow rate G31 (g/h) 64 293 179 75
6 LPG G30/31 - 37 mbar UR2 int. UR2 ext. R AUX
Rated heating capacity (kW) 0.8 4.0 2.50 1.05
Nozzle diameter (1/100 mm) 42 96 75 50
Pre-chamber (printed on nozzle) - (S4) (Z) -
Reduced flow rate (W) 450 1500 800 450
Rated flow rate G30 (g/h) 58 291 182 76
Rated flow rate G31 (g/h) 57 286 179 75
Gas types IT
GB
IE
FR
BE
ES PT RU
SE
DK
FI
NO
PL HU