This equipment can be broken down with vibration emissions.
For these reasons, Atrix expects end-users to dispose of the material in an environmentally
friendly way through separate collection and treatment.
This Electrical and Electronic Equipment denoted with the following 'crossed out wheeled bin'
symbol, indicates that the equipment should be disposed of, by the end-user, separate from
other types of waste.
End-users should contact their dealer/distributor for disposal, collection, and recycling options
in their country.
Vibration Test:
According to Clause FF of EN 60335-2-69:2012, vibration total value ah is less than 2.5m/s
2,
a
h
< 2.5m/s
2
Declared dual-number noise emission values:
Machine Type: Omega Supreme Plus, Model no. VACOMEGAUM2F, 50/60Hz, 230V, 450 Watts
DECLARED DUAL-NUMBER NOISE EMISSION VALUES: in accordance with ISO
4871
Operating mode 1
Operating mode 2
No load
Normal
Measured A-weighted emission sound pressure level,
LpA
(ref. 20 uPa) at operator's position, in
decibels
72.76
72.67
Uncertainty KpA, in
decibels
2
2
Note-The sum of a measured noise emission value and its associated uncertainty represents an
upper boundary of the range of values which is likely to occur in measurements.
This machine has a decibel rating of 72.76 at operator’s position. This machine has a decibel
rating of less than 70 decibels measured according to OSHA standards. Hearing protection is
not required but advised.
This machine has a motor designed and manufactured by Ametek. It has a maximum flow rate
of 86 Cubic Feet per Minute OR 146.11 Cubic Meters per Hour and maximum under pressure
of 1,645 Millimeters of Water Column OR 16,131.93 Hectopascal Pressure Units.