2.
Check Enable Alarm Input Handling.
3.
Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4.
Refer to Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
5.
Click Copy to... to copy the sengs to other alarm input channels.
6.
Click Save.
Set Video Quality Diagnosis
When the video quality of the device is abnormal and the alarm linkage is set, the alarm will be
triggered automacally.
Steps
1.
Go to Conguraon → Event → Basic Event → Video Quality Diagnosis .
2.
Select Diagnosis Type.
3.
Set the corresponding parameters.
Alarm Detecon Interval
The me interval to detect the excepon.
Sensivity
The higher the value is, the more easily the excepon will be detected, and the higher
possibility of misinformaon would be.
Alarm Delay Times
The device uploads the alarm when the alarm reaches the set number of mes.
4.
Check Enable, and the selected diagnosis type will be detected.
5.
Set arming schedule. See
Set Arming Schedule .
6.
Set linkage method. See Linkage Method Sengs .
7.
Click Save.
Note
The funcon is only supported by certain models. The actual display varies with models.
Set Vibraon Detecon
It is used to detect whether the device is vibrang. The device reports an alarm and triggers linkage
acons if the funcon is enabled.
Steps
1.
Go to Conguraon → Event → Basic Event → Vibraon Detecon .
2.
Check Enable.
3.
Drag the slider to set the detecon sensivity. You can also enter number to set the sensivity.
4.
Set the arming schedule. See
Set Arming Schedule .