Page 8 AXIS T81B22 DC 30W Midspan
Mounting instructions
The AXIS T81B22 may be wall or bench mounted using the rear side
holes. It can also be mounted on a DIN rail.
Note the following before mounting the AXIS T81B22:
• Do not cover the midspan or block the airflow to the product with any
foreign object. Keep the midspan away from excessive heat and
humidity, and free from vibration and dust.
• Ensure that the cable length from the Ethernet network source to
your Axis video product does not exceed 100 meters (330 feet). See
page 9 for information on cable lengths. The midspan is not a repeater
and does not amplify the Ethernet data signal.
• Use a splitter if required, but ensure that the splitter is connected
close to your Axis video product and not to the Midspan.
• There is no "on-off" switch; simply plug the AXIS T81B22 into a DC
power outlet.
To mount:
1. Install two screws vertically at a distance of 65 mm
(2.5”) on the wall or shelf.
2. Align the AXIS T81B22 mounting slots to capture the
surface screws
A 6 to 7 mm (0.23" to 0.27")
B max 2.5 mm
C 2 mm to 3 mm (0.059" to 0.098")
D 3.0 mm (0.12")
A
B
D
c