Thermal & Optical Bi-spectrum Network Camera User Manual
14
Chapter 4 Fire and Smoke Detection
The device will trigger and upload alarm when detect the fire source or smoke.
Fire and smoke detection is applied to fire-prevention purposes in scenic region, forest, tunnel and
so on. You can configure the fire source detection parameters and smoke detection parameters.
When fire source or smoke is detected, the alarm actions will be triggered.
Note
Not all models support the smoke detection function, take the actual product for reference.
4.1 Recommended Scene
This part introduces the recommended scenes of fire source detection and helps you select the
appropriate scene.
Fire source detection can be applied to indoor and outdoor monitoring with a large detection
radius. To achieve the best monitoring effect, please set the installation place as requirements
below.
The installation place should be the highest position within the detection area. The lens should
not be covered during movement to detect the maximum area.
It is better to choose the installation place with convenient traffic, well-equipped power and
internet facilities. E.g. communication tower, watchtower, high-rise roof and so on.
4.2 Set Fire Detection Parameters
To avoid the potential fire damage, you should configure the fire detection function for certain
areas. The detail configuration steps show as below.
Before You Start
Go to Configuration System Maintenance VCA Resource Type, select Temperature
Measurement + Behavior Analysis or Temperature Measurement + Fire Detection.
Steps
1. Go to Configuration Local.
2. Check Locate Highest Temperature Point to display the position of highest temperature. Check
Frame Fire Point to frame the fire source on live view.
3. Go to Configuration Event Smart Event, select Dynamic Fire Source Detection.
4. Check Enable Dynamic Fire Source Detection.
5. Set the parameters of fire detection.
Fire Source Detection Mode
Smoking Mode