PUR FM2500V PLUS Faucet Mount Water Filtration System, 3-in-1 Powerful, Natural Mineral

Product's Documents

Below are documents related to this product, you can read online or download:

Owner’s Manual

This is the main product document for model FM2500V.

The file format is pdf, 8 pages, you can download this manual here .

background
FILTER TECHNOLOGY
WITH
®
Faucet Filtration System
Owners Manual
Faucet Unit Model No. PFM100B, PFM150W, PFM200B, PFM222B, PFM270G, PFM280K,
PFM300V, PFM350V, PFM360F, PFM400H, PFM400HC, PFM410V and PFM450S.
Replacement Filter Model No. RF-3375, RF-9999 and PFF991C.
background
Your PUR System
What’s in the Box
Step 1: Filter Installation Instructions
Step 2: Aerator Removal
Thank you for choosing PUR! Cleaner drinking water is the
foundation of good health. Our patented and certified water filtration
systems with MAXION Technology will transform your tap water into
cleaner, fresh-tasting drinking water. To learn more about PUR,
please visit PUR.com.
Step 3: System Installation Instructions
Step 4: Turn on Filtered Water
External Threaded
Faucets
Internal Threaded
Faucets
1 PUR Device
1 Filter
Cartridge
1 2 3
Bag Containing 3 Back-up Adapters and Washers
Some faucets may not need an adapter.
If an adapter is needed, choose the one that fits your faucet.
Twist back cover off
Insert filter into the device
(Don’t worry, the filter will fit loosely)
Replace back cover
Remove your original aerator and its washer.
Use a rubber jar opener if aerator is difficult to remove.
First try attaching the device by itself.
You may not need an adapter.
If the device does not fit your faucet use
one of the supplied adapters.
External Threaded Faucets
If the device does not fit,
attach adapter 1.
Finger-tighten the
adapter and
washer to
your faucet.
Internal Threaded Faucets
Attach adapter 2. If
adapter 2 does not fit,
try adapter 3.
Finger-tighten the
adapter and washer
to your faucet.
If the enclosed adapters do not fit, please do not return to store.
Contact PUR for a free adapter that fits your faucet: PUR.com/support
1-800-PUR-LINE ConsumerRelations@HelenofTroy.com
IMPORTANT: Device needs to be level to fasten evenly.
Position the device so that the PUR
®
logo is facing you. Finger-tighten the threaded
mounting nut, turning counterclockwise, to attach the device to your faucet .
Turn down the lever for filtered water.
Before first use, run cold water for
5 minutes in filtered position.
STOP!
STOP!
background
Your PUR System
What’s in the Box
Step 1: Filter Installation Instructions
Step 2: Aerator Removal
Thank you for choosing PUR! Cleaner drinking water is the
foundation of good health. Our patented and certified water filtration
systems with MAXION Technology will transform your tap water into
cleaner, fresh-tasting drinking water. To learn more about PUR,
please visit PUR.com.
Step 3: System Installation Instructions
Step 4: Turn on Filtered Water
External Threaded
Faucets
Internal Threaded
Faucets
1 PUR Device
1 Filter
Cartridge
1 2 3
Bag Containing 3 Back-up Adapters and Washers
Some faucets may not need an adapter.
If an adapter is needed, choose the one that fits your faucet.
Twist back cover off
Insert filter into the device
(Don’t worry, the filter will fit loosely)
Replace back cover
Remove your original aerator and its washer.
Use a rubber jar opener if aerator is difficult to remove.
First try attaching the device by itself.
You may not need an adapter.
If the device does not fit your faucet use
one of the supplied adapters.
External Threaded Faucets
If the device does not fit,
attach adapter 1.
Finger-tighten the
adapter and
washer to
your faucet.
Internal Threaded Faucets
Attach adapter 2. If
adapter 2 does not fit,
try adapter 3.
Finger-tighten the
adapter and washer
to your faucet.
If the enclosed adapters do not fit, please do not return to store.
Contact PUR for a free adapter that fits your faucet: PUR.com/support
1-800-PUR-LINE ConsumerRelations@HelenofTroy.com
IMPORTANT: Device needs to be level to fasten evenly.
Position the device so that the PUR
®
logo is facing you. Finger-tighten the threaded
mounting nut, turning counterclockwise, to attach the device to your faucet .
Turn down the lever for filtered water.
Before first use, run cold water for
5 minutes in filtered position.
STOP!
STOP!
background
Troubleshooting
CleanSensor
Monitor
Before first use, run cold water for 5 minutes in filtered position.
During filter flush, it is normal to see cloudy water and hear the sound of
water pushing air out of the filter cartridge. Flushing removes any loose
materials, which is normal.
Prior to each use, run cold water for 5 seconds in filtered position to activate filter.
Never run hot water through the filter.
Do not use the water above 100˚F/38˚C as this may alter the filter.
Use cold water only.
For best performance change your filter every three months or 100 gallons filtered,
whichever comes first.
To change the filter or if you need sink space, remove the device from your
faucet by unscrewing the threaded mounting nut. After each new filter
cartridge is installed, run cold water for 5 minutes to flush it.
Clean the exterior of the faucet mount housing with a damp sponge or soft cloth.
A mild dishwashing liquid may also be used. Using anything else
to clean your faucet mount could result in damage to the unit.
For more information, please visit PUR.com/support
Two Year Warranty
Kaz (Warrantor), warrants your PUR Faucet Mount Water Filter Unit (PFM100B, PFM150W, PFM200B,
PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H, PFM400HC, PFM410V and
PFM450S) for two (2) years from the date of purchase (except for the filter cartridge which is
warranted for 30 days) against all defects in materials and workmanship, when used in compliance
with the owner’s manual.
If the product proves to be defective within two years from the date of purchase, call 1-800-787-5463
The warrantor assumes no responsibility for incidental or consequential damages; for damages arising
out of misuse of the product or use of any unauthorized attachment; or for damages resulting from the
use of the product with a defective water faucet. Some states do not allow the exclusion or limitation of
incidental or consequential damages; so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other legal rights which vary from state
to state. System complies with applicable state and local regulations.
Should service be required or you have any questions regarding how to use your PUR product, please contact
PUR Consumer Relations: PUR.com/support 1-800-PUR-LINE ConsumerRelations@HelenofTroy.com
Filter is working
Change filter soon End of filter life
When filtered water is activated, the CleanSensor
Monitor indicates filter status
and guarantees you will always have safer and healthier filtered drinking water.
Green light will flash 6 times as you begin to use the filter. Replacement of filter
cartridge resets the light.
The CleanSensor
Monitor changes color depending on how long the filter has
been in use or how much water has been filtered. Filter will reach end of life at
100+ gallons filtered or 90+ days used.
The CleanSensor
Monitor contains a non-replaceable battery.
The battery will eventually
stop working but the filter
is still functional.
Use and Care
Technical Specifications:
FILTER CAPACITY: 100 gallons (378 liters)/up to 3 months
RATED SERVICE FLOW: 0.52 gallons/minute (2.0 liters/minute) at 60 psig
MAXIMUM TEMPERATURE: 100°F (38°C)
MINIMUM TEMPERATURE: 34°F (1°C)
MAXIMUM WORKING PRESSURE: 100 psig (690 kPa)
MINIMUM WORKING PRESSURE: 20 psig (138 kPa)
System and installation shall comply with applicable state and local regulations.
For system to perform as shown in the Performance Data Sheet, it is necessary to replace the
filter when it exceeds filter capacity (100 gallons).
Testing was performed under standard laboratory conditions, actual performance may vary.
The contaminants or other substances removed or reduced by this water filter are not neces-
sarily in all users’ water. Do not use with water that is microbiologically unsafe, or of unknown
quality, without adequate disinfection before or after the system. Systems that are certified for
cyst reduction may be used on disinfected water that may contain filterable cysts. Individuals
requiring water of certain microbiological purity should consult their physician.
Replacement filters may be purchased at most retail outlets or at PUR.com.
Installation issues
You may not need an adapter. After original aerator and washer
are removed, try attaching the device to your faucet. If adapter
is needed, check to make sure the old aerator washer was
removed and only the new adapter washer is being used.
Make sure device is level to the faucet in order for the
threaded mounting nut to attach to the faucet threading.
Turn counterclockwise to tighten.
Water leaks around the faucet
adapter or threaded mounting nut
• Check to see that the washer and screen are placed
in the threaded mounting nut.
If using an adapter, make sure the adapter is
hand-tightened securely to the faucet.
Slow water flow, after 3 months of
use, in the filtered position
When filter is near end of life, water will run slower in the
filtered position. Replace your filter to ensure contaminant
removal is at the certified levels.
Water leaks out around the faucet
mount back cover
Try tightening faucet mount back cover all the way until tight.
If that doesn’t solve the problem, remove the filter cartridge
and reinstall the filter cartridge again. Tighten the faucet
mount back cover before use.
Difficulty in removing the old filter
cartridge to replace the filter
Remove the device from the faucet by turning the
threaded mounting nut clockwise.
• Remove the faucet mount back cover.
• Slowly turn or twist the filter cartridge. This will help loosen
the filter.
PFM100B, PFM150W, PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H,
PFM410V and PFM450S Systems Tested and Certified by NSF International against NSF/ANSI Standards 42, 53
and 401 for the reduction of the claims specified on the Performance Data Sheet.
PFM100B, PFM150W, PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H,
PFM400HC, PFM410V and PFM450S Systems Tested and Certified by WQA against NSF/ANSI Standards 42,
53 and 401 for the reduction of the claims specified on the Performance Data Sheet.
background
Troubleshooting
CleanSensor
Monitor
Before first use, run cold water for 5 minutes in filtered position.
During filter flush, it is normal to see cloudy water and hear the sound of
water pushing air out of the filter cartridge. Flushing removes any loose
materials, which is normal.
Prior to each use, run cold water for 5 seconds in filtered position to activate filter.
Never run hot water through the filter.
Do not use the water above 100˚F/38˚C as this may alter the filter.
Use cold water only.
For best performance change your filter every three months or 100 gallons filtered,
whichever comes first.
To change the filter or if you need sink space, remove the device from your
faucet by unscrewing the threaded mounting nut. After each new filter
cartridge is installed, run cold water for 5 minutes to flush it.
Clean the exterior of the faucet mount housing with a damp sponge or soft cloth.
A mild dishwashing liquid may also be used. Using anything else
to clean your faucet mount could result in damage to the unit.
For more information, please visit PUR.com/support
Two Year Warranty
Kaz (Warrantor), warrants your PUR Faucet Mount Water Filter Unit (PFM100B, PFM150W, PFM200B,
PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H, PFM400HC, PFM410V and
PFM450S) for two (2) years from the date of purchase (except for the filter cartridge which is
warranted for 30 days) against all defects in materials and workmanship, when used in compliance
with the owner’s manual.
If the product proves to be defective within two years from the date of purchase, call 1-800-787-5463
The warrantor assumes no responsibility for incidental or consequential damages; for damages arising
out of misuse of the product or use of any unauthorized attachment; or for damages resulting from the
use of the product with a defective water faucet. Some states do not allow the exclusion or limitation of
incidental or consequential damages; so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other legal rights which vary from state
to state. System complies with applicable state and local regulations.
Should service be required or you have any questions regarding how to use your PUR product, please contact
PUR Consumer Relations: PUR.com/support 1-800-PUR-LINE ConsumerRelations@HelenofTroy.com
Filter is working
Change filter soon End of filter life
When filtered water is activated, the CleanSensor
Monitor indicates filter status
and guarantees you will always have safer and healthier filtered drinking water.
Green light will flash 6 times as you begin to use the filter. Replacement of filter
cartridge resets the light.
The CleanSensor
Monitor changes color depending on how long the filter has
been in use or how much water has been filtered. Filter will reach end of life at
100+ gallons filtered or 90+ days used.
The CleanSensor
Monitor contains a non-replaceable battery.
The battery will eventually
stop working but the filter
is still functional.
Use and Care
Technical Specifications:
FILTER CAPACITY: 100 gallons (378 liters)/up to 3 months
RATED SERVICE FLOW: 0.52 gallons/minute (2.0 liters/minute) at 60 psig
MAXIMUM TEMPERATURE: 100°F (38°C)
MINIMUM TEMPERATURE: 34°F (1°C)
MAXIMUM WORKING PRESSURE: 100 psig (690 kPa)
MINIMUM WORKING PRESSURE: 20 psig (138 kPa)
System and installation shall comply with applicable state and local regulations.
For system to perform as shown in the Performance Data Sheet, it is necessary to replace the
filter when it exceeds filter capacity (100 gallons).
Testing was performed under standard laboratory conditions, actual performance may vary.
The contaminants or other substances removed or reduced by this water filter are not neces-
sarily in all users’ water. Do not use with water that is microbiologically unsafe, or of unknown
quality, without adequate disinfection before or after the system. Systems that are certified for
cyst reduction may be used on disinfected water that may contain filterable cysts. Individuals
requiring water of certain microbiological purity should consult their physician.
Replacement filters may be purchased at most retail outlets or at PUR.com.
Installation issues
• You may not need an adapter. After original aerator and washer
are removed, try attaching the device to your faucet. If adapter
is needed, check to make sure the old aerator washer was
removed and only the new adapter washer is being used.
Make sure device is level to the faucet in order for the
threaded mounting nut to attach to the faucet threading.
Turn counterclockwise to tighten.
Water leaks around the faucet
adapter or threaded mounting nut
• Check to see that the washer and screen are placed
in the threaded mounting nut.
If using an adapter, make sure the adapter is
hand-tightened securely to the faucet.
Slow water flow, after 3 months of
use, in the filtered position
When filter is near end of life, water will run slower in the
filtered position. Replace your filter to ensure contaminant
removal is at the certified levels.
Water leaks out around the faucet
mount back cover
Try tightening faucet mount back cover all the way until tight.
If that doesn’t solve the problem, remove the filter cartridge
and reinstall the filter cartridge again. Tighten the faucet
mount back cover before use.
Difficulty in removing the old filter
cartridge to replace the filter
Remove the device from the faucet by turning the
threaded mounting nut clockwise.
• Remove the faucet mount back cover.
• Slowly turn or twist the filter cartridge. This will help loosen
the filter.
PFM100B, PFM150W, PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H,
PFM410V and PFM450S Systems Tested and Certified by NSF International against NSF/ANSI Standards 42, 53
and 401 for the reduction of the claims specified on the Performance Data Sheet.
PFM100B, PFM150W, PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H,
PFM400HC, PFM410V and PFM450S Systems Tested and Certified by WQA against NSF/ANSI Standards 42,
53 and 401 for the reduction of the claims specified on the Performance Data Sheet.
background
Performance Data Sheet
For Faucet Mount Unit Model No. PFM100B, PFM150W, Replacement Filter Model No. RF-3375 or RF-9999. For Faucet
Mount Unit Model No. PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H, PFM410V,
PFM450S, Replacement Filter Model No. RF-9999. For Faucet Mount Unit Model No. PFM400HC, Replacement Filter Model
No. PFF991C. These systems have been tested according to NSF/ANSI 42, 53 and 401 for reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentra-
tion less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53 and 401.
Substance
PUR Reduction data
NSF/ANSI Standard Requirements
Overall % Reduction Influent challenge
concentration (mg/L)
% Reduction Requirement /
Maximum permissible product
water concentration (mg/L)
Standard 42 - Aesthetic Effects
Chlorine Taste and Odor 96% 2.0 mg/L ± 10% 50%
Nominal Particulate Class I
particles 0.5 to <1 μm
98.8% at least 10,000 particles/mL 85%
Standard 53 - Health Effects
Asbestos > 99% 107 to 108 fibers/L; fibers
greater than 10 μm in length
99%
Cyst > 99.99% minimum 50,000/L 99.95%
2 ,4-D 93.8% 0.210 ± 10% 0.07
2,4, 5-TP (Silvex) 99.7% 0.15 ± 10% 0.05
Atrazine > 94.2% 0.009 ± 10% 0.003
Benzene > 96.5% 0.015 ± 10% 0.005
Carbofuran > 97% 0.08 ± 10% 0.04
Carbon Tetrachloride > 96.8% 0.015 ± 10% 0.005
Chlordane > 99.5% 0.04 ± 10% 0.002
Endrin > 96.8% 0.006 ± 10% 0.002
Ethylbenzene 99.9% 2.1 ± 10% 0.7
Heptachlor Epoxide > 99.6% 0.004 ± 10% 0.0002
Lead (pH6.5) > 99.7% 0.15 ± 10% 0.010
Lead (pH8.5) 99.9% 0.15 ± 10% 0.010
Lindane > 99% 0.002 ± 10% 0.0002
Mercury (pH6.5) > 96.7% 0.006 ± 10% 0.002
Mercury (pH8.5) 96.4% 0.006 ± 10% 0.002
Methoxychlor 99.8% 0.12 ± 10% 0.04
Monochlorobenzene > 99.9% 2.0 ± 10% 0.1
o-Dichlorobenzene > 99.9% 1.8 ± 10% 0.6
Simazine > 98.5% 0.012 ± 10% 0.004
Styrene > 99.9% 2.0 ± 10% 0.1
Tetrachloroethylene > 96.7% 0.015 ± 10% 0.005
Toluene > 99.9% 3.0 ± 10% 1
Toxaphene > 92.9% 0.015 ± 10% 0.003
Trichloroethylene > 99.8% 0.300 ± 10% 0.005
TTHM 99.7% 0.45 ± 20% 0.080
VOC (chloroform surrogate) 99.3% 0.300 0.015
Substance
Chemical
Reduction %
Influent challenge
concentration (mg/L)
Maximum permissible product
water concentration (mg/L)
Alachlor >99% 0.050 0.001
Atrazine >99.8% 0.100 0.003
Benzene >99% 0.081 0.001
Carbofuran >99% 0.190 0.001
Carbon tetrachloride 98% 0.078 0.0018
Chlorobenzene 99.9% 0.077 0.001
Chloropicrin 99% 0.015 0.0002
2,4-D 98% 0.110 0.0017
Dibromochloropropane (DBCP)
>99% 0.052 0.00002
o-Dichlorobenzene >99% 0.080 0.001
p-Dichlorobenzene >98% 0.040 0.001
1,2-Dichloroethane 95% 0.088 0.0048
1,1-Dichloroethylene >99% 0.083 0.001
cis-1,2-Dichloroethylene >99% 0.170 0.0005
trans-1,2-Dichloroethylene >99% 0.086 0.001
1,2-Dichloropropane >99% 0.080 0.001
cis-1,3-Dichloropropylene >99% 0.079 0.001
Dinoseb 99% 0.170 0.0002
Endrin 99% 0.053 0.00059
Ethylbenzene >99% 0.088 0.001
Ethylene dibromide (EDB) >99% 0.044 0.00002
Haloacetonitriles (HAN):
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
98%
98%
98%
98%
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
Haloketones (HK):
1,1-Dichloro-2-propanone
1,1,1-Trichloro-2-propanone
99%
96%
0.0072
0.0082
0.0001
0.0003
Heptachlor 96% 0.025 0.00001
Heptachlor epoxide 98% 0.0107 0.0002
Hexachlorobutadiene >98% 0.044 0.001
Hexachlorocyclopentadiene >99% 0.060 0.000002
Lindane >99% 0.055 0.00001
Methoxychlor >99% 0.050 0.0001
Pentachlorophenol >99% 0.096 0.001
Simazine >97% 0.120 0.004
Styrene >99% 0.150 0.0005
1,1,2,2-Tetrachloroethane >99% 0.081 0.001
Tetrachloroethylene >99% 0.081 0.001
Toluene >99% 0.078 0.001
2,4,5-TP (silvex) 99% 0.270 0.0016
Tribromoacetic acid >98% 0.042 0.001
1,2,4-trichlorobenzene >99% 0.160 0.0005
VOC (reduction claims for organic chemicals included by chloroform surrogate testing)
background
Performance Data Sheet
For Faucet Mount Unit Model No. PFM100B, PFM150W, Replacement Filter Model No. RF-3375 or RF-9999. For Faucet
Mount Unit Model No. PFM200B, PFM222B, PFM270G, PFM280K, PFM300V, PFM350V, PFM360F, PFM400H, PFM410V,
PFM450S, Replacement Filter Model No. RF-9999. For Faucet Mount Unit Model No. PFM400HC, Replacement Filter Model
No. PFF991C. These systems have been tested according to NSF/ANSI 42, 53 and 401 for reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentra-
tion less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53 and 401.
Substance
PUR Reduction data
NSF/ANSI Standard Requirements
Overall % Reduction Influent challenge
concentration (mg/L)
% Reduction Requirement /
Maximum permissible product
water concentration (mg/L)
Standard 42 - Aesthetic Effects
Chlorine Taste and Odor 96% 2.0 mg/L ± 10% 50%
Nominal Particulate Class I
particles 0.5 to <1 μm
98.8% at least 10,000 particles/mL 85%
Standard 53 - Health Effects
Asbestos > 99% 107 to 108 fibers/L; fibers
greater than 10 μm in length
99%
Cyst > 99.99% minimum 50,000/L 99.95%
2 ,4-D 93.8% 0.210 ± 10% 0.07
2,4, 5-TP (Silvex) 99.7% 0.15 ± 10% 0.05
Atrazine > 94.2% 0.009 ± 10% 0.003
Benzene > 96.5% 0.015 ± 10% 0.005
Carbofuran > 97% 0.08 ± 10% 0.04
Carbon Tetrachloride > 96.8% 0.015 ± 10% 0.005
Chlordane > 99.5% 0.04 ± 10% 0.002
Endrin > 96.8% 0.006 ± 10% 0.002
Ethylbenzene 99.9% 2.1 ± 10% 0.7
Heptachlor Epoxide > 99.6% 0.004 ± 10% 0.0002
Lead (pH6.5) > 99.7% 0.15 ± 10% 0.010
Lead (pH8.5) 99.9% 0.15 ± 10% 0.010
Lindane > 99% 0.002 ± 10% 0.0002
Mercury (pH6.5) > 96.7% 0.006 ± 10% 0.002
Mercury (pH8.5) 96.4% 0.006 ± 10% 0.002
Methoxychlor 99.8% 0.12 ± 10% 0.04
Monochlorobenzene > 99.9% 2.0 ± 10% 0.1
o-Dichlorobenzene > 99.9% 1.8 ± 10% 0.6
Simazine > 98.5% 0.012 ± 10% 0.004
Styrene > 99.9% 2.0 ± 10% 0.1
Tetrachloroethylene > 96.7% 0.015 ± 10% 0.005
Toluene > 99.9% 3.0 ± 10% 1
Toxaphene > 92.9% 0.015 ± 10% 0.003
Trichloroethylene > 99.8% 0.300 ± 10% 0.005
TTHM 99.7% 0.45 ± 20% 0.080
VOC (chloroform surrogate) 99.3% 0.300 0.015
Substance
Chemical
Reduction %
Influent challenge
concentration (mg/L)
Maximum permissible product
water concentration (mg/L)
Alachlor >99% 0.050 0.001
Atrazine >99.8% 0.100 0.003
Benzene >99% 0.081 0.001
Carbofuran >99% 0.190 0.001
Carbon tetrachloride 98% 0.078 0.0018
Chlorobenzene 99.9% 0.077 0.001
Chloropicrin 99% 0.015 0.0002
2,4-D 98% 0.110 0.0017
Dibromochloropropane (DBCP)
>99% 0.052 0.00002
o-Dichlorobenzene >99% 0.080 0.001
p-Dichlorobenzene >98% 0.040 0.001
1,2-Dichloroethane 95% 0.088 0.0048
1,1-Dichloroethylene >99% 0.083 0.001
cis-1,2-Dichloroethylene >99% 0.170 0.0005
trans-1,2-Dichloroethylene >99% 0.086 0.001
1,2-Dichloropropane >99% 0.080 0.001
cis-1,3-Dichloropropylene >99% 0.079 0.001
Dinoseb 99% 0.170 0.0002
Endrin 99% 0.053 0.00059
Ethylbenzene >99% 0.088 0.001
Ethylene dibromide (EDB) >99% 0.044 0.00002
Haloacetonitriles (HAN):
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
98%
98%
98%
98%
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
Haloketones (HK):
1,1-Dichloro-2-propanone
1,1,1-Trichloro-2-propanone
99%
96%
0.0072
0.0082
0.0001
0.0003
Heptachlor 96% 0.025 0.00001
Heptachlor epoxide 98% 0.0107 0.0002
Hexachlorobutadiene >98% 0.044 0.001
Hexachlorocyclopentadiene >99% 0.060 0.000002
Lindane >99% 0.055 0.00001
Methoxychlor >99% 0.050 0.0001
Pentachlorophenol >99% 0.096 0.001
Simazine >97% 0.120 0.004
Styrene >99% 0.150 0.0005
1,1,2,2-Tetrachloroethane >99% 0.081 0.001
Tetrachloroethylene >99% 0.081 0.001
Toluene >99% 0.078 0.001
2,4,5-TP (silvex) 99% 0.270 0.0016
Tribromoacetic acid >98% 0.042 0.001
1,2,4-trichlorobenzene >99% 0.160 0.0005
VOC (reduction claims for organic chemicals included by chloroform surrogate testing)
background
© 2019 All rights reserved. Distr. by Kaz USA, Inc.,
A Helen of Troy Company, 400 Donald Lynch Boulevard, Marlborough, MA 01752
PUR
®
and MAXION
®
are registered trademarks of Helen of Troy Limited.
Substance
Chemical
Reduction %
Influent challenge
concentration (mg/L)
Maximum permissible product
water concentration (mg/L)
1,1,1 -trichloroethane 95% 0.084 0.0046
1,1,2 - trichloroethane >99% 0.150 0.0005
Trichloroethylene >99% 0.180 0.0010
Trihalomethanes (includes):
Chloroform (surrogate chemical)
Bromoform
Bromodichloromethane
Chlorodibromomethane
95% 0.300 0.015
Xylenes (total) >99% 0.070 0.001
VOC (reduction claims for organic chemicals included by chloroform surrogate testing)
Substance
PUR Reduction data
NSF/ANSI Standard Requirements
Overall % Reduction Influent challenge
concentration (ng/L)
% Reduction Requirement /
Maximum permissible product
water concentration (ng/L)
Standard 401 - Emerging Compounds
Atenolol >95.8% 200 ± 20% 30
Bisphenol A 97.7% 2000 ± 20% 300
Carbamazepine >98.7% 1400 ± 20% 200
DEET 98.5% 1400 ± 20% 200
Estrone >96.5% 140 ± 20% 20
Linuron >96.6% 140 ± 20% 20
Meprobamate >94.8% 400 ± 20% 60
Metolachlor >98.6% 1400 ± 20% 200
Nonyl Phenol >96.3% 1400 ± 20% 200
TCEP 97.9% 5000 ± 20% 700
TCPP 97.1% 5000 ± 20% 700
Trimethoprim >96.3% 140 ± 20% 20
Purchases Made in Iowa
NSF Standard 401 has been deemed as “incidental contaminants/emerging compounds.” Incidental contaminants are those
compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
For purchases made in Iowa: This form must be signed and dated by the buyer and seller prior to consummation of this
sale. This form should be retained on file by the seller for a minimum of two years.
Name
Address
City
State Zip
Signature Date
Name
Address
City
State Zip
Signature Date
BUYER: SELLER:
28AUG19
P/N: A003997R0

Specifications

PUR FM2500V Questions and Answers