Remote Display True-rms Clamp Meter
Specifications
37
Frequency via Flexible Current Probe
Range .....................................................5.0 to 500.0 Hz
Resolution ...............................................0.1 Hz
Accuracy .................................................0.5 % ± 5 digits
Trigger Level ...........................................5 to 20 Hz, 25 A
20 to 100 Hz, 20 A
100 to 500 Hz, 25 A
Resistance
Range .....................................................600 Ω/6 kΩ/60 kΩ
Resolution ...............................................0.1 Ω/1 Ω/10 Ω
Accuracy .................................................1 % ± 5 digits
Mechanical Specifications
Size (L x W x H) .....................................277 mm *88 mm * 43 mm (55 mm for remote unit)
Weight.....................................................350 g
Jaw Opening ...........................................34 mm
Flexible Current Probe Diameter ............7.5 mm