Diode Test
Turn off circuit power before testing. For best results, diodes
should be measured out of circuit.
Also refer to
CHEK.
Good Diode
Forward Bias
Single
Beep
Reverse Bias
Good Diode Good Diode
fda03.eps
Bad Diode
Shorted
and
Open
Bad Diode Bad Diode