INSTALLATION
1
2
3
4. Check for gas system leaks with a
manometer. If a manometer is not
available, test all connections by
brushing on a soapy water solution.
Connecting the Water
(steam models only)
IMPORTANT
The supply line must be equipped with an
approved manual shutoff valve. This valve
should be located in the same room as the
laundry center and should be in a location
that allows ease of opening and closing. DO
NOT block access to the gas shutoff valve.
IMPORTANT
Installation to the gas service must follow
local codes and ordinances and the latest
edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54 or in Canada, CSA B149.1.
WARNING
Periodically inspect all water inlet hoses
for water leaks, wear, cuts, corrosion and
bulges. Replace all hoses, if any sign of
the above is visible. All hoses should be
replaced every 5 years to reduce the risk
of hose failures.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open flame.
1. Remove COLD inlet hose from COLD
water supply and inspect for rubber
washer. Replace washer if it is torn or
worn out.
2. Turn on COLD
supply and run
water to clear any
contaminants in the
line.
1
2
1. To dryer connection
2. From Gas supply
3. Shutoff Valve in open position.
1. Rubber washer
must be present
and undamaged
2. Cold inlet hose to
washer
1
3. Inspect hose couplings for proper
placement of rubber washers. Use hoses
from ASSEMBLY HOSE KIT# 5304495002
(not included).
1. Rubber washer must be present and
undamaged.
3. Open the shutoff valve in the gas
supply line to allow gas to flow through
the pipe. Wait a few minutes for gas to
move through the gas line.