W2
A
D
D
C
B B1
E1 E1
E2 E2
3"
(76 mm)
3"
(76 mm)
84"
(2134 mm)
B B1
A
C
(102 mm)
E2 E2
13
3
2 /16
" - 4 /16"
(72 - 106 mm)
4"
W1
A
D
C
W2
A
D
C
B B1
F
B
E1E1 E1
E2 E2 E2
3"
(76 mm)
3"
(76 mm)
84"
(2134 mm)
A
B
C
B B1
A
C
E2 E2 E2
(102 mm)
13
2 /16
" - 4
(72 - 106 mm)
3
/16
"
4"
Side-by-Side Installation
Cut out dimensions for Side-by-Side installation with two appliances
The cut out width for the Side-by-Side combinations is defined by adding the single width of each of the
models in the combination.
Installation Options
64 65
Recommended Installations Considerations
Stand-alone
All Monolith appliances can be installed as a left-hinge or right-hinge stand-alone
unit. When dimensioning the cabinet, include the thickness of the door panel and
handle (see page 67, Door Clearance Requirements).
Ensure the Monolith appliance is installed so the door has clearance from any
adjacent wall or any kitchen element.
Side-by-Side
within one
cabinet
Monolith appliances can be installed Side-by-Side within one cabinet by installing a
Side-by-Side kit, which must be purchased separately. When dimensioning the
cabinet, include the thickness of the door panel and handle (see page 67, Door Clear-
ance Requirements).
During design and installation, please take into account the layout of left and right
hinged appliances without the risk of door opening collision.
Ensure that the Monolith appliances are installed in such a way that the doors do not
interfere with any adjacent wall or any kitchen element.
Side-by-Side
within
separate
cabinets
Monolith appliances can be installed Side-by-Side within separate cabinets. If the
panel between the cabinet is less than 4" (102 mm) a side wall heater is required.
The heater must be ordered separately.
When dimensioning the cabinet, include the thickness of the door panel and handle,
in order to prevent any door opening collision (see page 67, Door Clearance
Requirements).
A minimum partition of 6" (154 mm) width is required to ensure that handles do not
collide when doors are opened centered towards each other or facing each other.
Ensure that the Monolith appliances are installed so the doors have clearance from
any adjacent wall or kitchen element.
Triple
Side-by-Side
When combining more than two Monoliths together there are different installation options:
(A) A panel with a minimum thickness of 5/8" (16 mm) can be used between the third
appliance and the kitted together pair. Using a 5/8" (16 mm) panel, requires a side
wall heater between units. Note there will be door inteference with this set up.
(B) A minimum partition of 4" (102 mm) width is required to ensure that handles do not
collide when doors are opened in the same direction or 6" (154 mm) width is required
to ensure that handles do not collide when doors are opened centered towards each
other.
(C) It is possible to install three units using two Side-by-Side kits. This is not a recom-
mended configuration, as there will be door interference and potential door panel
damage (right side door cannot be open or closed while middle door is open).
Although the use of stainless steel panels offers a true Side-by-Side integrated look,
always consider door interference and potential door panels and/or handles damage.
It is recommended that a 90° door limiter be used on all center appliances to minimize
interference between doors and handles and potential damage.
A Cabinet depth frameless installation style = 25" (635 mm). Cabinet depth inset installation style = 25" (635 mm) + panel thickness.
B At this point the power cord exits from the appliance rear. 3/4" (19 mm) from the left and 5" (127 mm) from the floor.
Free length of the power cord is 98" (2.5 m).
B1
Please refer to the specific models to be installed in the combination for a precise location of this point for each model (see product pages).
C The appliance has a recess in this area for cable and waterline laying. 1" (25 mm) in depth and 5 1/2" (140 mm) in height over the whole
width of the appliance.
D This surface is visible when the appliance door is open. Designed finish is required.
E1, E2 Depending on the appliance, the anti-tipping bracket is positioned at the top (E1) or base (E2) of the appliance and must be secured to
the wall or to the floor, please refer to the installation manual for more information.
F A minimum partition of 5/8” (16 mm) width is required when the installation type with a separate recess for additional appliance is applied.
Note, there will be door interference with this set up. A minimum partition of 4” (102 mm) width is required to ensure that handles do not collide
when doors are opened in the same direction. A minimum partition of 6” (154 mm) width is required to ensure that handles do not collide when
doors are opened centered towards each other and 90° door limiter (included in scope of supply) is applied at the same time.
W1, W2 Width of one or two appliances.
Cut out dimensions for Side-by-Side installation with three or more appliances
The cut out width for the Side-by-Side combination of more than two units is defined adding the width of the
two units attached Side-by-Side plus a partition plus the width of the single unit.
Appliance
side view
C
Individual to the niche Continuous along the wall
Individual to the niche Continuous along the wall
W2
42" (1067 mm)
48" (1219 mm)
54" (1372 mm)
60" (1524 mm)
66" (1676 mm)
72" (1829 mm)
W2 W1
42" (1067 mm) 18" (457 mm)
48" (1219 mm) 24" (610 mm)
54" (1372 mm) 30" (762 mm)
60" (1524 mm) 36" (914 mm)
66" (1676 mm)
72" (1829 mm)
Loading ...
Loading ...